3 August 24, 1995 Mr. George A. Hunger, Jr.

Director-Licensing, MC 62A-1 PECO Energy Company Nuclear Group Headquarters Correspondence Control Desk P.O. Box No. 195 Wayne, PA 19087-0195

SUBJECT:

RELIEF REQUEST RR-14 (REVISION 4), PEACH BOTTOM ATOMIC POWER STATION, UNITS 2 AND 3, (TAC NOS. M91866 AND M91867)

Dear Mr. Hunger:

The NRC staff has reviewed relief request RR-14 (Revision 4) as discussed in your letters dated February 27, 1995 and July 21, 1995, for the Peach Bottom Atomic Power Station, Units 2 and 3, Inservice Inspection (ISI) Program.

RR-14 requests the use of Code Case N-498-1 and Code Case N-416-1. The relief requests are for the second 10-year interval Inservice Inspection.

Use of ASME Code Case N-498-1 as an alternative for Peact. Bottom Atomic Power Station, Units 2 and 3, is authorized pursuant to 10 CFR 50.55a(a)(3)(ii) as compliance with the specift.d requirements of Section XI would result in hardship or unusual difficulty without a compensating increase in the level of quality 'and safety.

Use of Code Cast. N-416-1 is also authorized pursuant to 10 CFR 50.55a(a)

(3)(11) provided that the proposed surface examinations are performed en the root (pass) layer of butt and socket welds on the pressure retaining boundary of Class 3 components when the surface examination method is used in accordance with ASME Section III.

Use of above Code Cases is authorized through the duration of the currently approved ISI program for Peach Bottom. The staff's evaluation and conclusions are contained in the enclosed Safety Evaluation.

Sincerely, original signed by John F. Stolz, Director Project Directorate I-2 Division of Reactor Projects - I/II Office of Nuclear Reactor Regulation Docket Nos. 50-277/278

Enclosure:

Safety Evaluation cc w/ encl: See next page

  • Previous Concurrence n

t 0FFICE PD142dA' PDI-2/PM

  • PdI/2 ECGB
  • PDit2/D NAME MbihNN JZimmerman N GBagchi JStoh E N/95 8/08/95 6 /9Y/95 8/08/95 8/15/95

$/d/95 DATE

/

0FFICIAL RECORD COPY k DOCUMENT NAME: G: \\SPEA\\ PEACH \\PB91866'.RP, *y

?

NRC R CENTER COPT 9508300045 950 ADOCK 0500 7

{DR

y-y*"%.

....po

. A UNITED STATES E

L NUCLEAR' REGULATORY COMMISSION WASHINGTON. D C. 2056dKW1

(.....,/

August 24,-1995 Mr. George A.. Hunger, Jr.

Director-Licensing, MC 62A-1 PECO Energy Company Nuclear Group Headquarters Correspondence Control Desk P.O. Box No. 195 Wayne, PA 19087-0195

SUBJECT:

RELIEF REQUEST RR-14 (REVISION 4), PEACH BOTTOM ATOMIC POWER STATION, UNITS 2 AND 3.,

(TT.C NOS. M91866 AND M91867)

Dear Mr. Hunger:

The NRC staff has reviewed relief request RR-14 (Revision 4) as discussed in your letters dated February 27, 1995 and July 21, 1995, for the Peach Bottom Atomic Power Station, Units 2 and 3, Inservice Inspection (ISI) Program.

RR-14 requests the use of Code Case N-498-1 and Code Case N-416-1.

The relief requests are for the second 10-year interval Inservice Inspection.

Use of ASME Code Case N-498-1 as an alternative for Peach Bottom Atomic Power Station, Units 2 and 3, is authorized pursuant to 10 CFR 50.55a(a)(3)(ii) as compliance with the specified requirements of Section XI would result in hardship or unusual difficulty without a compensating increase in the level of quality and safety.

Use of Code Case N-416-1 is also authort_ad pursuant _ to 10 CFR 50.55a(a)

(3)(11) provided that the proposed surface examinations are performed on the root (pass) layer of butt and socket welds on the pressure retaining boundary of Class 3 components when the surface examination method is used in accordance with ASME Section III.

Use of above Code Cases is authorized through the daration of the currently approved ISI program for Peach Bottom. The staff's evaluation and conclusions are contained in the enclosed Safety Evaluation.

Sincerely, r/

~

J hn F. Stolz, Dir tor roject Directorate I-2 Division of Reactor Projects - I/II Office of Nuclear Reactor Regulation Docket Nos. 50-277/278

Enclosure:

Safety Evaluation cc w/ enc 1:

See next page

3; m

",' ~

iMr.- Ge:rge? A. Hunger, Jr.

Peach Bottos Atcaic Powar Station, m

-PECO Energy Company.

Units 2 and 3 cc:

l J

4

-3 J.'W. Durham,-Sr.,, Esquire Mr. Rich R. Janati, Chief Sr.-V.P.-& General Counsel Division of Nuclear. Safety:

PECO Energy Company; Pennsylvania Department of

2301 Market Street, S26-1 Environmental Resources Philadelphia,- Pennsylvania-19101

-P. O. Box 8469' i

Harrisburg, Pennsylvania. 17105-8469 PECO Energy Company ATTN: Mr. G.-R. Rainey,-Vice President Board-of Supervisors Peach Bottom Atomic Power Station Peach Bottom. Township.

Route 1, Box 208 P.. D. #1 Delta, Pennsylvania 17314 Delta, Pennsylvanic 17314 PECO Energy Company Public Service Commission of Maryland ATTN: Regulatory Engineer,' A4-5S Engineering Division Peach Bottom Atomic Power Station Chief Engineer Route 1, Box 208 6 St. Paul Centre i

Delta, Pennsylvania 17314 Baltimore, MD 21202-6806

. Resident Inspector Mr. Richard McLean U.S. Nuclear Regulatory Commission Power Plant and Environmental-Peach Bottom Atomic Power Station

- Review Division

+

P.O. Box 399 Department of Natural Resources '

Delta, Pennsylvania 17314 B-3, Tawes State Office Building-Annapolis, Maryland 21401 Regional Administrator, Region I-U.S. Nuclear Regulatory Commission Dr. Judith Johnsrud-475 Allendale Road National Energy Committee-King of Prussia, Pennsylvania 19406 l Sierra Club.

433-Or1ando Avenue Mr. Roland Fletcher State College, _PA 16803 Department of Environment 201 West Preston Street' Baltimore, Maryland 21201

)

A. F. Kirby, III External Operations - Nuclear Delmarva Power & Light. company P.O. Box 231 Wilmington, DE 19899

.i i

e b

t

m y

e; DISTRIBUTION

'# Docket

PUBLIC

.J. Zimerman PDIa2. Reading G. Hill, IRM (4) l W. Russell /F. Miraglia ACRS'(4)

R.J Zimerman OPA R.,Spessard, D/ DOTS C. Anderson, RGN-I

)

W. Dean, EDO G. Bagchi S.. Varga..

D. Terao c

J,. Zwolinski J. Stolz M. O'Brien 5

.J.

Shea

/

i 3