e p

g John D. O'Toole V,ce Pretroent 88 Consondated Ecson Company of New York. inc 4 If ving Place, New York, NY 10003 Tetepnone (212) 460-253's I

May 11, 1984 Re:

Indian Point Unit No. 2 Docket No. 50-247 Mr. Thomas T. Martin, Director Division of Engineering and Technical Programs U. S. Nuclear Regulatory Commission Reginn I 631 Park Avenue King of Prussia, Pa.

19406 t

Dear Mr. Martin This refers to I.E.

Inspection 50-247/84-04 conducted by Mr.

D.

J.

Collins of your office ftom January 31 through February 3,

1984 of activities authorized by NRC License No. DPR-26 at Indian Point Unit No.

2.

Your April 11, 1984 letter stated that it appeared that one of our activities was not conducted in full compliance with NRC requirements, as set forth in the Notice of violation enclosed therewith as Appendix A.

Our response to the items of non-compliance is presented in Attachment A to this letter.

Should you or your staff have any questions, please contact us.

Very truly yours'/

VW

))

.w cc Mr. Thomas Foley, Senior Resident Inspector U. S. Nuclear Regulatory Commission P. O. Box 38 Buchanan, New York 10511

.e ' '4./. 04 gy.

go t

8 14

,a b

7 e*

~

o s

ATTACHMFNT A Response to Notico of Violation Appendix A VIOLATION 10 CFR 20 203(c)(2)(iii) requires, in part, that (1) positive control be provided when access is required to a high radiation area (more than 100 millirem in one hour could be received by a major portion of the body),

or (2) the area be locked.

Contrary to the above, at about 3:00 PM, on January 31, 1984, an open equipment hatch access to the Unit I vapor container, a high radiation area with up to 2,500 millirem per hour exposure to major portions of the body, was neither under positive control nor locked.

This is a Severity Level IV violation (Supplement IV).

RESPONSE

[

In immediate response,to the above violation, the guard assignad to the post in question was recalled to his post and instructed not to leave unless properly relieved or dismissed by the Radiation Protection Supervisor or Nuclear Plant Operator (NPO).

In a review of the circumstances that led to this event we found that the

  • guard used a phone near the post to contact the Np0 for relief.

TN location of the phone did not allow the guard to maintain positive 4-f control of the equipment hatch in question.

To prevent such an occurrence in the future, post order guidelines have been revised to require that notifications of this nature be made by radio.

In addition, security guards assigned to any high radiation door will receive specific written post instructions from the Radiation Protection Supervisor, approved by the Security Ohift Supervisor.

This 1

will be accomplished by including them in the appropriate security post order book. This will be implemented by May 14, 1904.

I I