Forwards Objectives & Scope of Participation for Quad-Cities Nuclear Power Station Exercise to Be Conducted on 920429
ML20091K944
Person / Time
Site: Quad Cities  
Issue date: 01/13/1992
From: Schuster T
COMMONWEALTH EDISON CO.
To: Davis A
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
References
NUDOCS 9201270166
Download: ML20091K944 (10)


Text

g s

o (y;,4 -

=,.

f X. Commonwealth E" son 3[il,a

)- 1400 Opus Place f

y

.1_

-(

7 = Downers Crna, Illinois 60515

_Pltl?!M IWIIH y,

j --

nnt

- Jgsg N)g- -

~

+,

~

L_

.%y- (

t; January 13, 1992 g(pt i v dTC r

~

~

[y -

j f!Lh pq IMr'. A. Bert' Davis Regional Administrator U.S. Nuclear Regulatory Commission Region III-799 Roosavelt Road Glen Ellyn, IL 60137

~

Subject:

Quad Cities Nuclesr Station Units I and 2

" Transmittal of Objectives and Sr 3e of

. Participation for April 29, 1992 Generating

,+

! Station Emergency Plan (GSEP) Exercise."

NRC Docket Not 50:254 and 50-265 r

Dear Mr. Davis:

..' Enclosed are the Objectives and Scope of Participation for the Quad Citter.Niklear Power Station GSEP Exercise to be conducted April 29. 1992.

These stenario docunents are submitted in accordance with NRC and FEMA requirements.

If you have any questions regarding the Quae Cities Scope of

-Participation or Objectives. please call either Kevin Jackson at (312)294-8517 or Robert Carson at (312) 294-8662.

Respectfully, 8/A k b

W T. K. Sch*Jster Nuclear Licensing Administrator

-Enclosures

/cc:-

T. Polski

.RIII'

.s J

_._l'

~1431i1 43b 4

l

\\

9201270166.920113 i

PDR : ADO A 05000254 MN17ig f

PDR

, QUAQ_ClllES_ NUCLEAR _E0HEfLSIAIION -

192LGSEP_ EXERCISE J.x 6 g4

~

- SCOPLOLP.ARLIC12ALION r

-DAIE:

April 29. 1992-lY.P_E:

Daytime, Partial-10LE111LAGENCLEARI1ClfA110N:-

- NRC (Real titne ' activation from Region III) g State of. Illinois (Partial)

-Whiteside. County 4

-Rockulsland County-State of Iowa:

Scott. County Clinton County

-c

~

EURE0SE:

J

. Test the capability of-the basic elements within the Commonwealth Edison Company GSEP, as.well as their abi_lity to-interface with the NRC and partic!?ating state agencies.

The Exercise will include mobilization of CECO personnel and resources adequate to verify

their capability to respond to a: simulated emergency, CECO-FACILIIIES.ACJJyAIIp:
  • ! Control Room -

E

-* CEOF

~

  • JPIC~

fCICo FACILITIES _NOT ACTIVALED:

4

  • None

-Yhe:" Exercise"3 Nuclear:DutyLPerson.will-be_ notified of simulated events as. appropriate.cn a real-time basis.

The " Exercise" Nuclear Duty: Person-and-the-balance of-the Corporate Emergency Response-L0rganizatio_n will be-prepositioned-closeLto the Morrison EOF to

permit use of personnel from distant locations, i Commonwealth-Edison will demonstrate _ the capability: to make contact J

!withicontractors whose assistance would be required by the-simulated

cident situation,.but.will-not actua11ytincur the expense of sing E

icontractor services lto-simulate emergency response except as w

prearranged specificallyLforithe Exercise; Commonwealth 1 Edison will. arrange:to provide actual transportation-m and. communication support in accordance with existing agreements to thef extent specifically_ prearranged for the Exercise. Commonwealth Edison _will. provide-unforeseen actual assistance only to-the extent that tne resources are available and do not hinder normal operation 4

lof.the-Company.

1432:1

, -. ~ -

., +, _ _ _, -

r QUAD CITIES NUCLENR POWER STATION 1992 GSEP EXERCISE APRIL 29,-1992 OBJECTIVES LIST STANDARD OBJECTIVES FOR ANNUAL-GSEP EXERCISES AND DRILLS 1.

Assessmant and Classification Objectives a.

Demonstrate the ability to assess, within fifteen (15) minutes, conditions which warrant initiating a GSEP classification,. (CR, TSC, E0F, CEOF) b.

Dernonstrate the ability to determine applicable Emergency Action Levels (EALs) within fifteen (15) l minutes of initiating classification.

(CR, TSC, E0F, CEOF) 2.

Notification and Communication Objectives a.

Demonstrate the ability to correctly fill out a NARS form.

(CR, TSC, EOF, CEOF) b.

-Demonstrate the ability to-notify appropriato State and local organizations within fifteen (15) minutes of an Emergency classification or significant change in NARS information.

(CR, TSC, EOF, CEOF) c.

For the_ initial contact via the ENS, demonstrate the ability to correctly fil) out NRC Event Notification Worksheets.

(Also applicable for subsequent calls if a continuous line-is not maintained).

(CR, TSC, EOF, CEOF) d.

Demonstrate the ability to notify the NRC immediately following State notification and within one (1) hour after making an Emergency classification.

(CR, TSC, EOF, CE0F) e.

Demonstrate the ability to provide bourly information-updates to the States and within thirty (30) minutes of changes in latest reported conditions on the State Agency Update Checklist.

(CR, TSC, EOF, CEOF) f.

Demonstrate the ability to contact appropriate support organizations that would be available to assist in an actual emergency within one (1) hour of condition! warranting their assistance.

(e.g.

H+T, Teledyne) -(CR, TSC. LOF. CEOF) g.

Demonstrate the ability to maintain an open-line of communication with the NRC on ENS upon request.

(CR, TSC, EOF, CEOF) h.

Demonstrate the ability to maintain'an open-line of communication with the NRC on HPN upon request.

(TSC, EOF,-CEOF) 1433:1-

U QUAD CITIES NUJLEAR P0HER STATION 1992 G$tP EXERCISE q

APRIL 29, 1992 L

i, Demonstrate _the ability to provide information updates to-the NRC within thirty (30) minutes of significant changes in reportable conditions when an open-line of communication is not maintained.

(ENS and HPN)

(CR, TSC,_ EOF, CEOF)

-j.

Demonstrate the ability to provide adequate informational announcements (e.g.,ssembly j

instructions, changes in plant onditions) cver the l

plant public address system.

(CR)

3. -Radiological Assessment and Protective Actions Objectives 4

a.

Demonstrate the ability to collect and document radiological surveys taken for conditions presented E

in the scenario.

(TSC, OSC, EOF, CEOF) b.

Demonstrate the ability to trend radiological l

information for conditions presented in the scenario.

(TSC, OSC, EOF, CEOF) c.

Demonstrate the ability to take appropriate protective-actions for onsite personnel in accordance with_ Station procedures.

(e.g. respiratory protection, protective clothing, KI)

(OSC, TSC) d.

Demonstrate the ability to adequately prepa e W brief personnel for entry into High Radiath n Areas in accordance with Station procedures and poiicles.

(OSC, TSC) 7 e.

Demonstrate the ability to issue and administratively control dostmetry issued to teams dispatched from the OSC in accordance with-Station procedures.

(OSC) f.

Demonstrate the ability to establish radiological control in accordance with Health Physics procedures.

(TSC,_OSC, EOF, CEOF) l g.

Demonstrate the ability to monitor, track and document radiation exposure for inplant ope "*nns and maintenance teams in accordance with plant pv (TSC, OSC) 4 l

Lj-1433:2 l

l

~

QUAD' CITIES NUCLEAR POWER STATION 1992 GSEP EXERCISL

. APRIL 29, 1992'

-4 h.

Demonstrate the ability to perform decontaminatto, of radioactively contaminated individuals and equipm nt in accordance with Station procedures.

(OSC) 1.

Demonstrate the ability to identify appropriate Protective Action Recommendations (PARS) within fifteen (15) minutes of obtaining an Offsite Dose Projection or using a Protective Action Recommendation flowchart.

(TSC.- EOF, CEOF) j.

Demonstrate the ability to calculate Offsite Dose Projection in accordance with appropriate procedures.

(TSC, E0F, CEOF) k.

Demonstrate the ability to perform contamination control onsite in accordance with plant procedures.

(e.g. area access control, drinking, water, food supplies, return to normai use criteria)

(TSC, OSC) 1.

Demonstrate the ability to collect RCS and Containment Atmosphere samples using Post Accident Sample System (PASS) equipment in accordance with PASS procedures and proper Health Physics controls.

(CR, OSC.t m.

Demonstrate the ability to perform Core Damage

' Assessments in accordance with the EPIPs.

(TSC, EOF, CE0F) i 1433:3 l

l..

~_

)

QUAD CITIES NUCLEAR POWER STATION-

-l 1992 GSEP EXERCISE APRIt. 29, 1992 j

'4,-. Emergency Facilities Objectives a.

Demonstrate the Ob111ty to establish minimum staffing in the TSC and OSC within thirty (30) minutes of an LAlert or higher Classification during a daytime event in accordance with procedures.- (TSC, OSC) b.

Demonstrate the ability to augment the Control Room staff within thirty (30) minutes of an appropriate Emergency Classification in accordance with procedures.

(CR) c.-

Deib',htrate the ability to transfer Command and Control

- authority from the Control Room to the TSC.

(CR, TSC)

L

.d.

Demonstrate the ability to transfer Command and Control authority from the TSC to the E0F/CEOF.

(TSC, E0i, CE0F) e.

Demonstrate the ability to transfer Command and Control authority from the CEOF to the EOF.

(TSC, EOF, CEOF) f.

Demonstrate the ability 'n establish minimum staffing in the Emergency Operations facility and Joint Public Information Center within approximately one (1) hour of the Olte Emergency clavsification in accordance with procedures.

(EOF) g.

Demonstrate the ability to establish minimum staffing

.in-the Corporate Emergency Operations facility and Joint Public-Information Center within approximately one=(1) hour of the Site Emergency classification in accordance with EOF and JPIC procedures.

(CEOF, JrIC) h.

.Using information supplied by the Exercise scenario, demonstrate thel ability to record, track; and update information on the Status Boards at least every thirty

-(30) minutes. -(CR, TSC, OSC, EOF, CEOF)

Demonstrate the. ability to document Operations and

-1.-

Maintenance Team activities in logs and on appropriate-Status Boards.

(OSC) 4 j.

Demonstrate the ability to tract in-plant job status in logs and on appropriate Status Boards

-(CR, TSC, OSC, EOF, CEOF) 1433:4'

QUAD CITIES NUCLEAR POWER STATION 1992 GSEP EXERCfSE APRIL 29, 1992 L

Demonstrate the ability to exchange counterpart activity information between the ERFs at least every sixty (60) minutes.. (CR,_TSC, OSC, EOF, CEOF)

1. -

Demonstrate the ability to update and disseminate information from the Electronic Status Board.

(TSC, EOF) 5.

Emergency Direction and Control Objectives a.-

Demonstrate the

>*lty of the Directors and Managers to exert 3nmand and control in their respective area of responsibility as specified in procedures.

(CR, OSC, TSC, EOF, CEOF)

.b.

Demonstrate the ability to coordinate and expedite Operatict.s and Maintenance activities during abnormal and emergency situations.

(TSC, OSC, E0F, CEOF) c.

Demonstrate the ability to frloritize resources for 0;'erations and Maintenance activities during abn?.rmal-and emergency situation.

(TSC, OSC, EOF, CEOF) d.

Demonstrate the ability to acquire and transport emergency equipment and suppItes necessary to mitigate or control unsafe or abnormal plant conditions.

(TSC, OSC, EOF) e.

Demonstrate the ability of the Shift Engineer, Station Di" -tor, OSC Director tr,d MEO tt provide briefings and update concerning plant status, event classification, and activities in progress at least every sixty (60) minutes.

(CR, TSC, OSC, LOF, CEOF) f.

Demonstrate the ability to provide. access for the NRC Site Team in accordance with Access Control procedures.

(TSC, EOF, CEOF) 9 Demonstrate the ability to interface with the NRC Site Team.

(TSC, E07. CEOF) h.

Demonstrate the ability to identify and designate non-essential personnel within thirty (30) minutes after deciding to evacuate the site.

(TSC, EOF CEOF) 1.

Demonstrate the ability of individuals in the Emergency Response Organization to perform their assigned duties and responsibilities as specified in Generic GSEP.

(CR, TSC, OSC, EOF, CEOF) 1433:S

-QUAD CITIES NUCLEAR POWER STATION

.e

-1992 GSEP EXERCISE-

-APRIL 29, 1992

6. :Public Information' r

Objectives a.-

Demonstrate the ability to respond to Media requests within sixty (60) minutes inaccordance with CECO policies and procedures.

(JPIC) b.

'Demonstrats the ability to prepare accurate Press Releases withing ninety (90) minutes of significant

-event-while in a Site or General Emergency classification.

-(JPIC)

-1 c.

Demonstrate the ability to present Media Briefing within ninety (90) minutes of significant events while in a-Site or General Emergency classfication.

(JPIC) d.-

. Demonstrate the ability to use visual aids to support Media Briefing information In accordance with Ceco policies and procedures.

(JPIC) e.

Demonstrate the ability to maintain of CECO representative in the JPIC at all times.

(JPIC)

'7.-. Recovery Objectives a.

Demonstrate-the ability to determine-long-term recovery staffing requirements.

(TSC, EOF, JPIC) i

'1433:6=

l.

QUAD CITIES NUCLEAR POWER STATION-1992 GSEP EXERCISE

-APRIL 29, 1992 4

'0BJECTIVES TO BE DEMONSTRATED EVERY FIVE YEARS 8.

Miscellaneous Objectives a.

Demonstrate the backup means of communication for

'the NARs network.

(CR, TSC, EOF, CEOF) b.

Demonstrate the ability to determine the magnitude of the source term of a release.

(TbC, EOF, CEOF) c.

Demonstrate the ability to establish the relationship between effluent monitor readings-and onsite and offsite exposures / contamination for various meteorological conditions.

(TSC, EOF, CEOF, Field Teams) d.

Demonstrate the_ ability to determine the magnitude of a release based on plant system parameters and effluent monitors.

(TSC, EOF, CE0F) l e.

Demonstrate the ability to calculate release t

rate / projected doses if the primary instrumentation l

used for assessment is offscale or inopereble.

(TSC,. EOF, CE0F)'

f-Demonstrate the ability to assemble and account for On-site personnel within 30 minutes of a Site Emergency declaration.

(CR, TSC) 9 Demonstrate the ability to expikin the evacuation route, brief personnel and arrange for traffic control within one (1) hour of deciding to evacuate non-essential personnel.

(TSC, EOF, CEOF) h.

Demonstrate the ability to perform dose rate measurements in the environment for conditions

- presentM in the scenario.

(Fleld Teams) 1.

Demonstrate the ability to dispatch the Environs Teams within forty-five (45) minutes of determination of the need_for field samples.

(TSC, OSC) j.

Demonstrate the ability to control / coordinate Environs Teams activities in accordance with Corporate EPIPs. -(TSC, EOF, CEOF, Field: Teams)--

k.

Demonstrate-the abillty to transfer control / coordination of Environs Teams activities from the TSC to the EOF in accordance with Station and EOF procedures.

(TSC, EOF) l'433:7 L

QUAD CITIES NUCLEAR POWER STA110N 1992 GSEP EXERCISE APRIL 29, 1992 1.

Demonstrate the ability of-the Security force to respond to an emergency situation in accordance with procedures.

(Security) m.

Demonstrate the ability of the Security force to coordinate actions and interact with the Emergency Response Organization.

(Security) 9.

Public Information Objectives a.

Demonstrate the ability to exchange event information with Non-CECO JPIC representatives for Media Oriefings in accordance with CECO policies and procedures.

(JPIC) b.

Demonstrate the ability to coordinate information with Non-Ceco JPIC representatives for Media Briefings in accordance with CECO policies and procedures.

(JPIC) c.

Demonstrate the abilty to activate Rumor Control.

(JPIC)

10. Recovery Objectives a.

Demonstrate the ability to identify the criteria to enter a Recovery classification in accordance with procedures.

(TSC, EOF) b.

Demonstrate the ability to generate a Recovery Plan which will return the plant to normal operations in accordance with CECO policies and procedures.

(TSC, EOF) c.

Demonstrate the ability to coordinate recovery actions with the State.

(TSC, EOF) d.

Demonstrate the ability to coordinate recovery actions with the NRC.

(TSC, EOF) 1433:8-