Amend 168 to License NPF-3,revising TS 3/4.6.4.1, Combustible Gas Control Hydrogen Analyzers
ML20091K894
Person / Time
Site: Davis Besse 
Issue date: 01/16/1992
From: Hopkins J
Office of Nuclear Reactor Regulation
To:
Shared Package
ML20091K897 List:
References
NUDOCS 9201270145
Download: ML20091K894 (4)


Text

_ _ _ _ _ _ -___-_ __- ___

/,f **ov,jg e

UNITED STATES NUCLEAR REGULATORY COMMISSION A

n W

I wassiNotow, p. c. rous

%,e....,[

TOLEDO EDISON COMPANY CENTEkl0R SERYlCE COMPANY AND THE CLEVELAND ELECTRIC ILLUMINATING COMPANY DOCKET NO 50-346 DAVIS-BESSE NUCLEAR POWER STATION. UNIT N3.1, AMENDMENT TO FACILITY OPERATING LICENSE Amendment No. 168 License No. NPF-3 1.

The Nuclear Regulatory Commission (the Comission) has found that:

A.

The application for amendment by the Toledo Edison Company, Centerior Service Compan Company (the licensees) y, and the Cleveland Electric illuminating dated May 31, 1990, complies with the standards and requirements of the Atomic Energy Act of 1954, as amended (the Act), and the Commission's rules and regulations set forth in 10 CFR Chapter I; B.

The facility will operate in conformity with the application, the provisions of the Act, and the rules and regulations of the Commission; C.

There is reasonable assurance (1) that the activities authorized by this amendment can be conducted without endangering the health and safety of the public, and (ii) that such activities will be conducted in compliance with the Commission's regulations; D.

The issuance of this amendment will not be inimical to the common-defense and security or to the health and safety of the public; and E.

The issuance of this amendment is in accordance with 10 CFR Part 51 of the Comission's regulations and all applicable requirements have been satisfied.

2.

Accordingly, the license 1, amended by changes to the Technical Specifications as indicated in the attachment to this license amendment, and paragraph 2.C.(2) of facility Operating License No. NPF-3 is hereby l

amended to read as follows:

l 9201270145 920116 l

PDR ADDCX 05000346 P

PDR

2-(a) Lechnical_ Specifications The Technical specifications contained in Appendix A, as revised through Amendment N0. 168, are hereby intorporated in the license.

The Toledo Edison Company shall operate the facility in accordance l

with the Technical Specifications.

3.

This license amendment is effective as of its date of issuance and shall be implemented not later than 45 days af ter issuance.

FOR THE NUCLEAR REGULATORY COMMIS$10N

$7/

Jon B. Hopkins, Sr. Project Manager Project Directorate !!!-3 Division of Reactor Projects 111/IV/V Office of Nuclear Reactor Regulation

Attachment:

Changes to the Technical Specifications Date of issuance: January 16, 1992 s

v-

- - - +

y.,.p.

y

,.m--.p+.-

4m---

m.

e rm_m-Ti%

i

ATTACHMENT TO LICENSE AMENDMENT NO,168 FACILITY OPERATING LICENSE NO. NPT-3 DOCKET NO. 50-346 Replace the following page of the Appendix "A" Technical Specifications with the attached page. The revised page is identified by amendnent nunber and contain vertical lines indicating the area of change. The corresponding overleaf page are also provided to maintain document completeness.

i Remove Intert 3/4 6-23 3/4 6-23 E

4 I

t

,-.,---,w

CONTAINMENT SYSTEMS 3/4.6.4 COMBUSTIBLE GAS CONTROL HYDR 0 GEN ANALYZERS LIMITING CONDITION FOR OPERATION 3.6.4.1 Two independent containment hydrogen analyzers shall be 0PERABLE.

APPLICABILITY:

MODES I and 2.

ACTION:

a.

With one hydrogen analyzer inoperable, restore the inoperable analyzer to l

OPERABLE status within 30 days or be in at least HOT STANDBY within the next 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br />, b.

With both hydrogen analyzers inoperable, restore at least one analyzer to OPERABLE status within 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> or be in at least HOT STANDBY within the next 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br />.

SURVEILLANCE REQUIREMENTS 4.6.4.1 Each hydrogen analyzer shall be demonstrated OPERABLE at least once per 31 days by performance of a CHANNEL CHECK.

4.6.4.2 Each hydrogen analyzer shall be demonstrated OPERABLE at least once per 92 days on a STAGGERED TEST BASIS by performing a CHANNEL CAllBRATION using sample gases containing:

I a.

Zero volume percent hydrogen, balance nitrogen, and L

b.

2.5 + 0.5 volume-percent hydrogen, balance nitrogen.

l i

t I

DAVIS-BESSE, UNIT 1 3/4 6-23 Amendment No. 167, 168

- - -s

h l

i DELETED DAVIS.BESSE. UNIT I 3/4 6-24 Amendment No. 73,66

,