POWER AUTH_0RITY OF THE STATE OF NEW YORK DOCKET NO. 50.13]
JAMES A. FIT 2 PATRICK NUCLEAR POWER PLANT AMENDMENT TO FAClllTY OPERATING ll(1RSI Amendment No.180 License No. DPR-59 1.
The Nuclear Regulatory Commission (the Comission) has found that:
A.
The application for amendment by Power Authority of the State of New York (the licensee) dated November 15, 1991. and supplemented March 11, 1992, complies with the standards and requirements of the Atomic Energy Act of 1954, as amended (the Act) and the Commission's rules and regulations set forth in 10 CFR Chapter I; B.
The facility will operate in conformity with the application, the provisions of the Act, and the rules and regulations of the Comi:,sion; C.
There is reasonable assurance (i) that the activities authorized by this amendment can be conducted without endangering the health and safety of the public, and (ii) that such activities will be conducted in compliance with the Comission's regulations; D.
The issuance of this amendment will not be inimical to the comon defense and security or to the health and safety of the public; and E.
The issuance of this amendment is in accordance with 10 CFR Part 51 of the Comission's regulations and all applicable requirements have been satisfied.
2.
Accordingly, the license is amended by changes to the Technical Specifications as indicated in the attachment to this license amendment, and paragraph 2.C.(2) of Facility Operating License No. DPR-59 is hereby amended to read as follows:
9204210345 920413 PDR ADOCK 05000333 P
PDR l
. April 13, 1992 (2) Technical Specifications The Technical Specifications contained in Appendices A and B, as revised through Amendirent No.180, are hereby incorporated in the license. The licensee shall crerate the facility in accordance with the Technical Specifications.
3.
This license amendment is effective as of the date of its issuance to be implemented within 30 days.
FOR THE NUCLEAR REGULATORY COPFISSION AI0-Robert A. Capra, Director Project Directorate 1-1 Division of Reactor Projorts - I/II Office of Nuclear Peactor Regulation
Attachment:
Changes to the Technical Specifications Date of Issuance: April 13, 19:2
A1TACHMENT TO LICENSE AMENDMENT ll0.180
)
FACit.ITY OPERATING LICEt:SE NO DPR-59 DOCKET 110, 50-333 Revise Appendix A as follows:
Reniove Pages Insert Pages vi vi 145b 145b 145c 145c 145d 145d 145e 145e 156 156 156a 156a 157-162 157-160 161 162
JAFNPP t lST OF TABLES (Cont'd)
Table Title Pg 428 Minimum Test and Calibration Frcauency for Accident Mon;tonng 86a Instrumentation 4.6 1 Snubber Visualinspection Interval 161 l
4.6-2 Minimum Test and Calibration Frequency for Drywell Continuous 162a Atmosphere Radioactivity Monitoring System 4.7 1 Minimum Test and Calibration Frequency for Containment Monitoring 210 5ptems 4.7 2 Exception to Type C Tests 211 3.12 1 Water Spray / Sprinkler Protected Areas 241j 3.12 2 Carbon Dioxide Protected Areas 244k 3.12-3 Manual Fire Hose Stations 2441 4.12 1 Water Spray / Sprinkler System Tests 244q 4.12-2 Carbon Dioxide System Tests 244r 4.12 3 Manual Fire Hose Station Tests 244s 6.2-1 Minimum Shift Manning Requirements 260a 6.10-1 Component Cyclic or hansient Limits 261 Amendment No f,[, f,1[1,1[,1[4,1[,1[3,180 vi
JAFNPP 4.6 (cont'd) 3.6 (cont'd) 3.6.1 Shock Suppressors (Snubbers) 4.6.1 Shock Suppressors (Snubbers)
\\
AppHcability Applicabihty Applies to the operational status of the shock suppressors Apphes to the periodic testing requirement for the shock suppressors (snubbers).
(snubbers).
Objective Objectrve
]
To assure the capability of the snubbers to perferm their l
To assure the capability of the snubbers to:
intended functions.
l Prevent unrestrained pipe motion under dynamic loaos as might occur during an carihquake or severe transient,
\\and Allow normal thermal motion during startup and shutdown.
Specification Specification Each snubber sha!! be demonstrated operabic by periormance of the following augmented inservice inspection program.
1.
All snubbers shall be categorized into two groups: those 1.
During all modes of operation exCEpt Cold Shutdown j
and Refue!!ng, all snubbers which are required to protect accessible and those inaccessible during reactnr the primary coolant system or any other safety related operation. The visual inspection interval for each system or component shall be operable. During Cold category of snubbers shall be determined based upon Shutdown or Refueling mode of operation, only those the c itena provided in Table 4.6-1.
snubbers shail be operable which are on systems that
, are required to be operabte in these modes.
Amendment No If,f,f 180, 145b
JAFf1PP 3.6 (cont'd) 4.G (cont'd) 2.
With one or more snubbers inoperable, within 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> 2.
Visual inspection sha;l verify (1) that thee are no visible during normal operation, or within 7 days during Cold ir:dication., of damage or impaired OPERABILITY, (2)
Shutdown or Refueling mode of operation for systems attachments to the fouadation or supporting structure are which are required to be operab!e in these modes, secure, ar.d (3) in those locations where snubber complete one of the following:
movemerf.s can be manually induced without d.sconnecting the snubber, that the snubber has freedom a.
replace or restore the inoperable snubber (s) to of movement and is not froze up %ubbers which operable status or, appear inoperable as a result of visual inspections r:1ay be determined OPERABLE for the purpose of establishing the b.
declare the supported system inoperabic and fo!!ow om sual inspection interval, providing that (1) the cause the appropriate limiting condition for operation f the rejection is clearly established and remedieo for that statement for that system or' particular snubber and for other snubbers that may be c.
perform an engineering evaluation to show the generically susceptible; and (2) the affected snubber is inoperable snubber is unnecessary to assure functionally tested in the as found condition and operability of the system or to meet the design determ;ned OPERABLE per Spec"ications 4.6.1.7 or 4.6.l.8, criteria of the system, and remove the snubber from as applicable. Hydraulic snubbers which have lost the system.
utficient fluid to potentially cause uncovering of the fluid sservoir-to-snubber valve assembly port or bottoming of
.he fluid reservoir piston with the snubber in tl s fu!!y extended position sha!! be functionally tested to determine operability.
3.
With one or more snubbers found inoperable, within 72 3.
Once each operating cycle,10% of each type of snubbers hours perform a visual inspection of the supported shall be functiona!!y tested for operobility, either in place or component (s) associated with the inoperable snubber (s) in a bench test. For each unit and subsequent unit that and document the results. For all modes of operation does not meet the requiremer;is of 4.6.1.7 or 4.6.l.8, an except Cold Shutdown and Refueling, within 14 days additional 10% of that type of snubber s'ali be functionally complete an engineering evaluation as per Specification tested until no more failures are found, or a!! units have 4.6.l.6 to ensure that the inoperable snubber (s) has not been tested.
adversely affected the supported component (s). For Cold Shutdown or Refueling mode, this evaluation sha!! be completed within 30 days.
,f,f,1[8,180, Amendment ?Jo.
145c s
JAFNPP 3 6 (cont'd) 4.6 (cont'd) 4.
The representative sample selected for functionally testing shall include the various configurations, operating environments and the range of size and capacity of snubbers.
At least 25% of the snubbers in the representative sampic shall include snubbers from the following three categories:
a.
The first snubber away from reactor vessel nozzle.
b.
Snubbers within 5 feet of heavy equipment (valve, pump, turbine, motor, etc.),
i c.
Snuboers w; thin 10 fcct of the discharge from a safety relief valve.
In add: tion to the regular sarnple, snubbers which failed the previous functional test shall be retested during tne i
next test period. If a spare snubber has been installed in place of a fatic-d snubber, then tyth the faiied snubber (if it is repaired and installed in another position) and the spare snubber shal' te retested. Test rewits of inese snubbers t
may not be included for the re-ttmpiing.
Amendment No. gd, f,180, 145d
JAFNPP 3.6 (cont'd) 4.6 (cont'd) 5.
If any snubber selected for functional testing either faits to lockup or fails to move, i.e. is frozen in place, the cause will be evaluated and if due to manufacturer or design deficiency, snubbers of the same design subject to the same defect shall be functional!y. tested. This testing requirement shall be indep6ndent of the requirements stated above for snubbers not meeting the functional test acceptance criteria.
6.
For the snubber (s) found inoperab!c, an engirme-ing evaluation shall be performed on the components which are supported by the snubber (s). The pumose of this engineering evaluation shall be to determine if the components supported by the snubberle.) were adversely affected by the inopercbihty of the snu.ser(s) in order to ensure that the supported components remain capable of meeting the designed service requirements.
i Amendmerit No. Pf,f,180, 145c
JAFNPP 3.6 and 4.6 BASES (cont'd) j d
H^
(DELETFD) snubber (s) and the resuits sha;l be docu. er:ted. For a!I rnodas j
m of coera* ion except Cold Shutdcan and Refueling, within 14 j
1.
Shock Suppressors days an engincenng eva!uation sha:1 be perforrned to ensse tha' the inoperable snubber (s) has not adverse!y affected the Snubbers are designed to prevent unrestrained pipe motion supported canycnnot(s). For Cold Stutdown or rwhng under Cynamic loads as might occur during an earttxtuake or moda, this evaluation shari be compicted mitm 30 days. A severe fransient, whi;c allowing norma! thermal motion dunng period of 7 days has been sciected for repa:r or replacement of startup and shutdown. The consr.quence of an rnoperab!e the inoperable snubber dunrq cold shutdown n refuehng snubber is an increase in the probat4hty of structuras damage mode of operate a becuas? in these modes Sa relatrve to piping as a resu't of a sersmic or ott.cr event in:tiating probabity of structural damag to the pepng systems wotid dynamic loads. ft is the<efore required that all snubbers be lower due to lower values of total stresses or tne prpng required to protect the prrmary coolant system or any other systems. In case a shutdown rs regered, the aitc _ance of 36 safety system or component be operable during reactor hours to reach a cold shutcown corxistro-t wei pe-r~t an oroerly 1
operation. Snubbers excluded f om this irspection program shutdown consrstent with standard operatstg procedures.
are those instatted on non-safety related system and then only if their failure or failure of the system on which they are The visual inspecten f equency is based upon maintarn:rg a installed would have no adverse effect on any safety-related constant level of snutber protecten to systems. hefore. the system. Because the snubber protection is required on!y requred inspection interval vanes inve seiy wth the observed during low probabahty events, a pedod of 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> (for normal snobber failures and is determined by the r. umber of snoperabie operation) or 7 riays (for cold shutdown or reiseling mode of snubbers found dunng an rnspecton. Inspectons performc4 op ration) is allowed for repairs or replacement of the snubber bOfore that intervai has elapsed may be used as a ro pnor to taking any other action. Following the 72 hour8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> (or 7 reference point to determtne the next inspecto:t The I
day) period, 'he supported system must be declared irispectrons are performed for each catem of snubbers. The inoperable and the Limiting Condrtion of Operation s'atement snubbers se categorced by acersstt9tf 0.o.. accesszbie or for the supported system follcud As an altemat:ve to inaccessible Junng reactor operahon). The ret vwal 4
snubber repair or replacement an engineenng evaluation may inspection for each category may be imcc, the same, c=
be performed to snow that the scoperable snubber is reduced by as much as tm>-th:rds of the previous W.on unnecessary to assure operabihty of the sys'vn or to meet the interval. This interva! depends on the re.imber of unaccept$c design critena of the system; and, to remove the snubber from snubbers found in proporton to the tots number of snutbert g
1 the system. With one or more snubbers found inoperable, within 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> a visual inspection shall be oerformed on the
.ffIfd,180, Amendment No.
156
~
JAFrdPP 3 6 and 4.6 BASES (cont'd) in each category from th tvevous inspection. The intcevats order to deterrrare if any safety,efet o.mr ocnt or system may be increased up to 48 ricoths of few unacceptabic snubbers has been adversaly affected by t+ic wu q mil <4 cf itw snttutxt.
are found in the previous inspecton. Ito vrsual inspecton The engrrteenng evaluahon shan iterm.m
.;f >.;tter or tot ttw:
interval wdl not enceed 48 months. However, as for a!1 snobber mode of fadure has wiparted a 9;ruhcarit c!'ect or survedtance activities, unless otherwise noted, affowable degradaten or. the supported conwent or Wem tolerances of 25% are apphcable for stw;bbers. Table 4 6-1 estabitsbes three lirruts for detemvrvng the next visual inspection To provde assurance of snubber functiona: rehabddy. a interval correspondeng to the population of each catego f of representative sample of the estaned snubbers wd3 tn snubbers. For a category that dffers from the representawe functiona!!y tested durmg each operat:rvj cycle Selection of a sizes provided, the values for the next ir'.*pectm interval may be representative sample of 104 af each type of safety related found by interpola* ion from the brrsts provded in Columns A, B, snubbers provides a conf,dence level ethm acceptable krr-ts and C. Whera the hmit for unacceptable snubbers in Colornns A, that these supports wdl be o an operable corwMon Observed i
8 or C is determined by interpolation and includes a fractional failures of these sampte snubbers stuli regere functional teshng value, the kmit may be reduced to the next lower integer. The of addtmalursts.
first inspection interval determined usmg Table 4 6-1 shall be based upon the previous inspection interval as estabiched by Hydraulc snubbers and mecturical snubbers may each be the requirements in effect before amendment (
).
Any treated as a cfferent enhty tar the above survedlance programs inspection whose results require a shorter inspection interval wdi overnde the prevous schedule. When the ci se of the rejecton The scrwce hfe of a snubber es evaluated usavy marv;facturce of a snubber is clearfy estabGstx4 and remoded for that snubber input and informaton and ato through considerabon c4 tre insta taten and ma,ntenance records (new$f erstatied snubber.
r and for any other snubbers that rnay be genencarfy suscept:ble, and venfied by inservice functional testing, that snubber may be seal replaced, spr:ng repraced, m tagh racaten area in twp exempted from beerv; counted as enoperable. Genencacy temperature area, etc._).
The requ rement to morstor the rusceptible snubbers are those which are of a specifc malse or snubber service life is included to ensure that the snubbees model that have the same design features drectly related to perodcalt/ undergo a performance evaluahon in wcw of trew rejection of the srw;bber by vtsual inspecten, and are orTwlarly age and operat..v3 condbons. Thr,e records wd1 pewale
(
located or exposed to the same environmental condtions such stattsteal bases for future cons:dcra'on of staubber service Me f
as temperature, radation, and vibraton. V. hen a snubber is The requirements for the ma:ntenance of records arvj ;h -
found inoperable, an engineenng evaluaton is performed, in snubber scrwce IJo rewew are not ofended to af'ect pte.t addton to the determinaton of the snubber mode of fa:Iure,in operaton.
Arrendment f40.
- c. 180, 15Ga L - - - -- _
9 r
O p.
JAFNPP PAGES 1:.s7 THROUGH AND INCLUDING f 60 HAVE BEEN INTENTICf fALLY LEFT BLANK
--,-, u peo.
,sz.um 1
I l
(
JAFNPP 4
Table 4 61 Snutter Visualinsocct on Interval Number cf Unacceptable Snubbers ire Tin A3 Column B' Column C5 Pcedat en' '
u :Aded Repeat Reduce Cate; cry Interval Interval Interval 1
0 0
1 80 0
0 2
1CC 0
1 4
150 0
3 8
200 2
5 13 300 5
12 25
.............................................-.......................................................~...-.....................
Nctes:
1.
The next visual inspection interval for the population of a snubber category shall be determined based upon the previcus inspection interval and the number of unacceptable snubbers found during that interval. Snubbers may be categorized, based upon their accesLbility during power operation, as accessible or inaccessible. These categories may be examined separately or jointly. This decision shall be made and documented before any inspection and used as the basis upon which to determine the nex1 inspection interval for that category.
2, Interpolation between population or category sizes and the number of unacceptable snubbers is permissible. The next lower integer for the value of the limit for Columns A, B, C shall be used if that integer includes a fractional value of unacceptable snubbers as determined by interpolation.
3.
If the number of unacceptable snubbers is equal to or less than the number in Column A, the next inspection interval may be twics the previous interval but not greater than 48 months.
4.
If the number of ur acceptable snubbers is equal to or less than the number in Column B but greater than the number in Column A. the next inspection intervai shall be the same as the previous interval.
]
Amendment No.
,180, l
161
. _. -. - - -..._~_.._--._.- -.
JAFNPP Tab'e 4 61 (cort 'd)
Srutter visual lnstect'on Interval 5
sf t*e rumber Cf una00eptable Snubbers is equal to or greater than the number 4n C0r.,mq C, the neat insDeClion interval sha:1 be too thirds of the previous interval. HoAever if the number of una:ceptable snubbers is ! css than the number in Column C but greater than the number in Column B, the next interval shal be reduced by a factor that is one third of the ratio of the d;fference between the number of unacceptable snubbers found durir.g the previous interval and the number in Column B to the difference in the numberG in Columns B and C.
Amendment No.
, 180, 162
.,