ML20091D504

From kanterella
Jump to navigation Jump to search
Submits Justification for Individual Sholly Notice Re Tech Spec Changes Concerning Cycle 5 Reload & Analog Transmitter Trip Sys.Sholly Notices Originally Prepared w/840416 Fr Deadline Not Given Final Review & Approval Until 840427
ML20091D504
Person / Time
Site: Hatch 
Issue date: 05/02/1984
From: Lainas G
Office of Nuclear Reactor Regulation
To: Purple R
Office of Nuclear Reactor Regulation
Shared Package
ML20091D507 List:
References
NUDOCS 8405310298
Download: ML20091D504 (2)


Text

c.

i.1AY 2W MEMORANDUM FOR: Robert A. Purple, Deputy Director Division of Licensing FROM:

Gus C. Lainas, Assistant Director for Operating Reactors, DL

SUBJECT:

JUSTIFICATION FOR INDIVIDUAL SH0LLY NOTICE Individual Sholly Notices concerning Technical Specification changes dealing with the Hatch Unit 2 Cycle 5 reload and a new Analog Transmiter Trip System are required in order to issue the amendments that are required for restart of Hatch Unit 2 in the last week of June (Georgia Power Company's licensing representative recently confirmed this as the current schedule).

The Sholly Notices on these subjects were originally prepared as a monthly notice with an April 16, 1984 deadline in order to get into the Federal Register.

They were sent to OELD on April 11, 1984 and April 12, 1984 with requests that they be completed by April 16, 1984 to meet the monthly Sholly deadline.

They were concurred in by 0 ELD case lawyer R. Goddard on April 16, 1984 and April 18, 1984 and forwarded to J. Scinto's office where they were retrieved by the PM on April 18th, without having been signed out by J. Scinto. The individual notices were subsequently resubmitted to Scinto and he reviewed and approved them on April 27, 1984.

8me'p'NB1 S!"N3 BW" Gus C'."Lainas, Assistant Director for Operating Reactors, DL cc:

JStolz GRivenbark

-0

  1. DL ORBf4:DL OR$f3DL A-
DL RIn am' JRivenbark;cf JSttyh inas 4/

13/y/84 f/ /$4

/ff(84 S

\\

\\

\\

-l ON$$6

.-., PDR W

', l.

~

jW'%

UNITED STATES j

[

NUCLEAR REGULATORY COMMISSION lE TQTRllTION-WASHINGTON, D.C. 20665

(

ggg gjj May 10,1984

,0RB#4 Rdg e

k*****,o8 RIngram 1

DOCKET No. 50-366 MEMORANDUM FOR:

Docketing and Service Branch.

Office of the Secretary of the Commission FROM:

Office of Nuclear Reactor Regulation

SUBJECT:

EDWIN I. HATCH NUCLEAR PLANT, UNIT NO. 2 4

One signed original of the Federal Register Notice identified below is enclosed for your transmittal to the Office of the Federal Register for publication. Additional conformed copies ( 6 ) of ttie Notice are enclosed for your use.

Notice of Receipt of Application for Construction Permit (s) and Operating License (s).

Notice of Receipt of Partial Application for Construction Permit (s) and Facility License (s): Time for Submission of Views on Antitrust Matters.

@ Notice of Consideration of issuance of Amendment to Facility Operating License.*

Notice of Receipt of Applicati3n for Facility License (s); Notice of Availability of Applicant's Environmental Report; and Notice of Consideration of Issuance of Facility License (s) and Notice of Opportunity for Hearing.

Notice of Availability of NRC Draft / Final Environmental Statement.

Notice of Limited Work Authorization.

Notice of Availability of Safety Evaluation Report.

Notice of issuance of Construction Permit (s).

U Notice of Issuance of Facility Operating License (s) or Amendment (s).

C Order.

Exemption.

Notice of Granting of Relief.

Other: *Please insert date on the 7th nane 1st namaranh of thh antico fnr a '40 rf av a-intervention period, and call Caryn on extension' 28960 to inform her of the date inserted.

Referenced documents have been provided PDR.

WilF3PRu8farWeMF%at9@!4

Enclosure:

As stated

._ Rin,g,4,;D,.l 0RB#

ram

==

5/[0/84

==

OFFICIAL RECORD COPY

.