Final Significant Const Deficiency Rept 110 Re Gh Bettis Valve Actuator Stroking Times.Initially Reported on 840223. Valve Actuators Will Be Serviced W/New Seals & Lubricant. Also Reported Per Part 21
ML20090M588
Person / Time
Site: Waterford 
Issue date: 05/11/1984
From: Gerrets T
LOUISIANA POWER & LIGHT CO.
To: Jay Collins
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
References
REF-PT21-84 110, W3K84-1141, NUDOCS 8405290084
Download: ML20090M588 (3)


Text

--::

~

LOUISIANA 142 ORARONDE STRE POWER & LIGHT P O BOX 6000

  • NEW ORLEANS. LOUISIANA 70174 * (504) 366 234S g

UTIUTIES SYSTEM W3K84-1141 Q-3-A35.07.110 hb@O Mr. John T. Collins

!', f Regional Administrator, Region IV

\\(M \\ s t 7 'l ) $M U. S. Nuclear Regulatory Commission i

611 Ryan Plaza Drive, Suite 1000 Arlington, Texas 76012

REFERENCE:

Telecon C. N. Hooper (LP&L a ossman (NRC IV) on April 19, 1984

Dear Mr. Collins:

SUBJECT:

Waterford SES Unit No. 3 Docket No. 50-382 Significant Construction Deficiency No. 110 "G.H. Bettis (Part 21) Valve Actuators" Final Report In accordance with the requirements of 10CFR50.55(e), we are hereby providing two copies of the Final Report of Significant Construction Deficiency No. 110, "G.H. Bettis (Part 21) Valve Actuators". This item was previously reported as PRD No. 168.

If you have any questions, please advise.

Very truly yours, Y* Yo >c /e Mg%&

T. F. Cerrets Corporate Quality Assurance Manager TFG:CNH:VBR Attachment ec: Director Office of Inspection & Enforcement U. S. Nuclear Regulatory Commission Washington, D.C.

20555 (15 copies) 8405290004 840511 T_6 -27 g g PDR ADOCK 05000302 6

ppR

,c ;

iMr.. John T. Collins May 11',.1984

~

W3K84-1141 Page 2 cc: Director Office of Management Information and Program Control U. S. Nuclear Regulatory Commission Washington, D.C.

20555 Mr. E. L. Blake Shaw, Pittman, Potts & Trowbridge 1800 M Street, N.W.

Washington, D.C.

20036 Mr. W. M. Stevenson Monroe & Lemann 1424 Whitney Building New Orleans, Louisiana 70130 Records Center Institute of Nuclear Power Operations 1100 Circle 75 Parkway, Suite 1500 Atlanta, Georgia 30339 Mr. W. A. Cross 7910 Woodmont Avenue Suite 1200 Bethesda, Maryland 20814

g a

FINAL REPORT OF SIGNIFICANT CONSTRUCTION DEFICIENCY NO. 110 "G.H. BETTIS (PART 21) VALVE ACTUATORS" INTRODUCTION This report is submitted pursuant to 10CFR50.55(e).

It describes the problem concerning the potential degradation of performance related to actuator stroking times described in G.H. Bettis (Part 21).

This deficiency was notified to USNRC by G.H. Bettis Company in their 10CFR21 Report No. CAR #0023, dated February 13, 1984.

DESCRIPTION OF PROBLEM In their 10CFR21 report, dated February 13, 1984, Bettis identified the series /model numbers of their actuators which have potential of degradation in stroking times due to a particular combination of seal and grease used in the original manufacture.

Our review of series /model numbers of all Bettis manufactured actuators employed at Waterford Unit No. 3 valves and dampers revealed that there are only five (5) valve operators that fall under this classification. These five valve tag number are:

3CC-B187A/B, 3CC-B188A1, 3CC-B189B1, 3CC-B190A2, and 3CC-B191B2.

SAFETY EVALUATION The five valves identified above are located inside containment in lines supplying cooling water to RC pump motors and CEDM cooling coil. These components are not required to operate following a design basis accident and this cooling water is supplied from the nonessential seismically-qualifirsd component cooling water loop, which is isolated from the essential loop on a containment isolation signal. The failure of these valves to operate will not affect the ability of the Component Cooling Water System to perform its intended function following a design basis accident.

Hence, we have concluded that the above problem is not reportable under 10CFR50.55 (c).

CORRECTIVE ACTION The five valve actuators in question will be serviced with new seals and Dow Corning Holykote 44 lubricant in accordance with the recommendations contained in the C.H. Bettis 10CFR21 report.