NOMTHERN STATES POWER COMPANY w eN N E APoble. MIN N E BOTA 95401 May 21, 1976
[
hv v' ' '
s Mr Victor Stello, Director Sg\\h#j $
3 Division of Operating Reactors h,
T, g
U S Nuclear Regulatory Commission 3,
Washington, DC 20555 9
w.
Dear Mr Stello:
/Q
'~'
MONTICELLO NUCLEAR GENERATING PLANT Docket No. 50-263 License No. DPR-22 Compliance with Revised Inservice Inspection Testing Requirements In a letter dated April 28, 1976 from Mr D L Ziemann, Chief,0perating Reactors Branch # 2, USNRC, to Mr L 0 Mayer, NSP, we were asked to supply information re-lated to implementation of recent changes to 10CFR Part 50.55a. The following information is supplied in response to this request:
Beginning of Next 40-Month Inspection Period February 28, 1978 Date Technicel Specification t
Change Request will be submitted August 30, 1977 An initial request for relief from certain portions of ASME Section XI will be I
submitted in accordance with 10CFR Part 50.55a (g) (5) (iii) in conjunction with the Technical Specification Change Request to be submitted by August 30, 1977.
Submission of an In-Service Inspection Evaluation and Development Report is required by Technical Specification 6.7.C.2 following the five-year in-service inspection scheduled for the Autumn, 1977 refueling outage. This report was originally intended to describe the lifetime in-service inspection D
D eq s
TSEE
\\
97 "
Reguld, n"' ~1 File 9 -"*
5Z11 u.s. meu o"
/W
/. '
9102130377 760521
' V, s ' ')
.~g
.h hDR ADOCK 05000263 PDR
f NOR 4ERN OTATED POWER Coi..PANY Mr Victor Stello May 21, 1976 plan developed for the Monticello plant.
We believe that the recent changes to 10CFR Part 50.55a make the submittal of this report unnecessary.
The intent of the reporting requirement will be satisfied by our submittal to be made prior to August 30, 1977.
Yours very truly, Q
h.
W L 0 Mayer, PE Manager, Nuclear Support Services Lal/ RIM / deb cc:
G Charnoff J G Keppler MPCA - ATTN:
J W Fe rman
u s. Nucu An su cvL Aionv
>uMi:mion cxt t Nuuin n
/;iR: unu 10:.
50-263
. e. iu
' NRC DISTnt0UTION i on PART !,0 DO':KET f.1 ATERI AL
[o:
I HUM:
oAtt or uocuur NT NOR1HERN STATES' POWER COMPANY 5/21/76
- 19. VIqTO,R S.TELLO MINNEAPOLIS, MINN.
DATc nicovr o L. O. MAYER 5/24/76 W tron UNOTOngt0 PflOP iNPUTrOnM NUM0tn 06 cOPil5 nLCLiVC D Don gin AL
((UNC L ASGi F I L O NONE SIGNED Xcorv otecnieriON ENcLosunc LTR RE OUR 4/28/76 LTR...................,.
RE COMPLIANCE WITH REVISED INSERVICE. INSPECTION TESTING REQUIREMENTS.
\\
~
~ACKNO" W W DO NOT REMOVE ruart nu:E:
MONTICELLO SAFETY F OR ACTio:ciN F O R.'.! AT ion ENVIno 5/25/76 R.TT.
j ASSIGNED AD :
l-
~~
7 ASSIGNi'D AD.
g IidiCIT~CHIPF :
7.IEMANN (6)
LP2 Cil CilIEF :
PROJECT MA':AG R:
PROJr:CT MANAGER :
K LIC. A$SC:
DIGGS LIC. ASST. :
~
INTERN AL 0151 HIBUTION
(
REG FIT j_g!iT[:M1_P AGTl I__1_Frdri_SysTIt's rNrIPA 'I'EC11_
l RG FDR
[__11 INEna" L L_TnDEsc0 ERusT I
I&E
[A)
JC11R0EDC!L DEUAROYA EALLARD
_ _0 5T,D
..._.L A I t ' A S SPAUGLER COSSICK & STAFF E NC,_J NE r:tI'!G IPPCLITO i
SITP. TECll l
_.MlP.C
__ l'_\\CCARY l
_ CASE KNIGHT OPERATI :G REACTO:',S GA!: MILL l
__11AijAU_KR S Il2.'E I L STELI.0 STEPP ItARLESS PAUI,ICKI HUIEAN l
OPERATING TECH g
PROJECT !!ANAGEME!Tr HEACTOR SAFETY X EISE" HUT SITE AtiALYSIS 110Y D ROSS l
Sl!AO VOLLMER l
P. COLLINS tt0VAK
_pAER_
BUNCll llOlRITO:;
ROSZTOCZY SC!l','!:l;rER g J. COLLIMS PETERS 0:1 CllECK GillnCS KREGER til:llrZ l
ilELTEMES AT & I SITE SAFETY & EtPLIRC SKOV110LT SAI/rZ)1AN AtlALYS T S l'. lit REllo I)CliTO'I & filfl.T r.it I.X l L MfJ Al. UlSIllidullON CONTitOL NUMUL.H
_1.llDI(: MINNEAPOLIS.MN 11ATI, l.An itROOKilAVI:N llAT!, l.Ah T!C llEC. V-IE ULRIRSUl(URML) e
.__nSIc LA rDR SA.//
i COM'iUI.TANTS Y ~ A ST,n w em /g un.."" 1/qF.t:
it 8)d;ef,5l'
.