\\p MONTICELLO NUCLEAR GENERATING PIMf

,/ M Docket No. 50-263 License No. DPR-22 Annual Report of Primary Coolant Lenkage to Drywell This report is submitted in accordance with Section 6.7.C of Appendix A, Technical Specifications, of the Provisional Operating License for the Monticello Nuclear Generating Plant.

It is a sunnary of coolant leakage to the drywell measurements for the period of January 1 through Decenber 31, 1975.

Drywell Icakage is broadly classified as being from identified or unidentified Identified Icakage is piped from the recirculation pump seals, various s ou r c e s.

valve sten leak-offs, the reactor vessel flange leak-off, bulkhead drains, and l

vent cooler drains to the drywell closed radwaste sump. All other leakage is j

collected in the drywell open radwaste sump and classified as unidantified Icakage.

Drywell leakage is calculated daf.ly using flow integrators installed in the pump i

discharge lit.e of each sump. Accuracy of measurement is better than 137..

Drywell leakage is also continuously monitored by detecting changes in open and closed dry-well radwaste sump icyc1 sensed by special icvel transmitters installed for that pu rpose. Sensitivity of this system to coolant Icakage changes is better than 0.4 GPM with a response time of one minute.

Table I is a sunnary of drywell coolant Icakage t.casurements for 1975. As noted in the Table, all leakage remained well below the Technical Specification Limits of 5 GPM for unidentified leakage and 25 GPM for total leakage, l

l Yours very truly, W 8.8v L 0 Mayer, PE Manager of Nuclear Support Services IDM/DMM/ak 9102120530 760114 PDR ADOCK 05000263 cc: J G Keppler R

PDR 8

G Charnoff dM Minnesota Pollution Control Agency Attn: J W retuan Attachment

Table I Summary of Coolant Leaknge to Drywell during Power Operation - 1975 Leakage from Known Sources (GPM)

Leakage from Unknown Sources (GPM)

Total Irakage (GPM)

Month Highest Lewest Avg Highest Iowest Avg Highest Lowest Avg Remarks Jan 1.37 1.16 1.23 0.21 0.0 0.05 1.58 1.16 1.28 Shut down Jan 10 th ough Feb 6 Feb A.70 0.60 1.23 0.23 0.0 0.05 1.70 0.60 1.28 Mar 1.34 1.03 1.24 0.31 0.0 0.07 1.61 1.03 1.31 lApr 1.37 1.19 1.23 0.25 0.0 0.07 1.55 1.19 1.30 May 1.38 1.06 1.22 0.38 0.0 0.20 1.65 1.20 1.42 Shut down May 16-17 iJun 1.38 1.15 1.24 0.27 0.0 0.09 1.55 1.17 1.33 Jul 1.88 1.07 1.26 0.27 0.0 0.07 1.88 1.07 1.33

Aug 1.88 1.04 1.21 0.31 0.0 0.11 1.88 1.04 1.32

'Sep 2.22 1.04 1.25 0.42 0.0 0.24 2.64 1.19 1.49 shut down Sept 12 through Oct Nov 18 Nov 1.49 1.17 1.29 0.12 0.0 0.08 1.60 1.17 1.37 Dec 1.85 1.35 1.64 0.19 0.0 0.09 1.96 1.50 1.73 l

l l

Year 2.22 0.60 1.28 0.42 0.0 0.10 2.64 0.60 1.38 (8.4*)

(2.0*)

(10.6*)

(5.5*)

l l

  • Percentage of Technical Specification Limit I

MmEMM

NRC DISTRIBUTION TOR PART 50 DOCKET MATERI AL

' (TEMPOR ARY F ORM)

CONTROL NO:

4 c2 3 FILE:

i Q4cy. Northern States Pwr Co DATE OF DOC DATE REC'D LTR TWX RPT OTHER Minneapolis, MN tppgg 1 14-76 1-10-7b XXX TO:

ORIG CC OTHER SEN T NRC PDR _.

XX Hr Etello one signed SENT LOCAL PDR

=

CLASS UNCLASS PROPINFO INPUT NO CYS REC'O DOCKET NO:

1 50-263 XXXX DESCRIPTION:

ENCLOSURES:

Ltr trans the foll& wing:

Annual Report of Primary Coolant Leakage to Drywell.....per requirements of Tech Specs

....(40 cy6 enc 1 rec'd)

[

PLANT N AME: Monticello J1 j

~

FOR ACTION /lNFL RMATION 1-lb-70 chi DUTLER (L)

SCHWENCER (L) JIEM ANN (L)

REG AN (E)

REID(L)

W/ Copies W/ Copies

' W/(Copies W/ Copics W/ COPIES CLARK (L)

STOLZ (L)

DICKER (E)

LE AR (L)

W/ Cnpias W/ Copics W/ Copies W/ Copics PARR (L)

VASSALLO (L)

KNIGHTON (E) spits W/ Copies W/ Copics W/ Copics -

W/ Copics KNIEL (L)

PURPLE (L.)

YOUNGBLOOD (E)

LPR W/ Copies W/ Cop;cs W/ Copics W/ copies INTERNAL DISTRIBUTION Lnrn rit r TECH REVIEW DENTON LIC ASST A/T IND.

/NRC PDR SCHROEDER GRIMES

,,Al. DIGGS (L)

B R AIT M AN 70GC. ROOM P 506A MACCARY G AMMIL L H. GE ARIN (L)

SALTZMAN 7 GOSSICK/ST AF F KNIGHT KASTNER E. GOULBOURNE (L)

MELTZ f CASE PAWLICKl BALLARD P. KREUTZER (E)

SHAO SPANGLER J. LEE (L)

PLANS BOYD STELLO M. RUT.IBR00Y(L)

MCDONALD MOORE (L)

HOUSTON ENVIRO S. REED (E)

CHAPMAN DEYOUNG (L)

NOVAK MULLEli M. SERVICE (L)

DUBE (Ltr)

SKOVHOLT (L)

ROSS DICKER S. SHEPPARD (L)

E. COUPE GOLLE R (L) (Ltr)

IPPOLITC KNIGHTON M. SL ATER (E)

PETERSON P. CO L LINS TEDESCO YOUNGBLOOD H, SMITH (L)

HARTFIELD (2)

DENISE J. COLLINS REGAN S. TEETS (L)

KLECKER J1EG OPR L AIN AS PJ10 JECT LDR G. WILLI AMS (E)

EISENHUT

/ FIff6IfEGION (2)

BENAROYA y_H A4_.A_G.

V. WILSON (L)

WIGGINTON D i' d. ESS R. INGR 'M (L)

HIPC VOLLMER H. DUl:CANIg)

K. PARRIS11 (L)

EXTtr<N AL DISTRIBUTION 8

LOCALPDR #' i %' 5 5 N

/

TIC (ABERNATHY) (1)(2)(10) - N ATION AL L ABS 1 - PD R.S AN/L A/NY y1 -

/1 - NSIC (EUCHANAN) 1 - W. PENNINGTON, Rm E.201 GT 1 - BROOKH AVEN NAT LAB 1 - CONSU LT ANTS 1 - G. ULRIKSON ORNL i - ASLR 1 - Newton Andesson NEWM ARK /BLUME/AG B ABI AN

-/6 -gO t A big 5

/2,

RS HOhutMG7SENT

/

i/H'

_ _ _ _ _ _ _ _ _ _ _ _