QEF 550-0 Rev10 ion 13 October 1983

~^

ID/21,2F N P CT EQUIPMENT ARD SUFFIJES v

EE.0. -g Emergency Equipasst and Supplies Rev. 13 10-06-83 First Aid and Decon*=4== tion Facilities Rev. 3 10-06-83 EEE*I.

Inventary of Emergency Equipment Rev. 3 10-06-83 550-T1 l

Environs Sampling Supplies Rev. 6 10-06-83 550-71 Operational Support Center Energency Supplies Cabinet Rev. 5 10-06-83 550-T3 Emergency Situation Film Dosimeters Rev. 3 10-06-43 550-T4 Inorgency Operations Facility Supplies Rev. 4 10-06-83 550-T5 Technical Support Center Supplies Rev. 2 10-06-83 550-76 Boline Public Bospital Radiation Energency Area Supplies and Equipment Rev. 4 10-06-83 l

l APPROVED CCT 0 61983 d

Q.C.O.S.N.

8310270032 831021 (final)

~

PDR ADOCK 05000254 F

PDR

~

QEP 550-1 Revision 3 g

FIRST AID AND September 1983 DECONTAMINATION FACILITIES ID/2E A.

PURPOSE The purpose of this procedure is to describe the first aid and decon-tamination facilities and their locations.

l B.

REFERENCES 1.

None.

C.

PREREQUISITES 1.

None.

D.

PRECAUTIONS 1.

None.

E.

LIMITATIONS AND ACTIONS O

1.

The Shift Engineer who is on duty is responsible for the care of V) injured personnel. His duties include first aid, arranging for medical assistance, and transportation to the hospital as required. First aid practices are those approved by the company.

F.

PROCEDURE 1.

Location of on-Site First Aid Equipment.

a.

Stretchers and Blankets.

Maintenance Shop.

Lift Station - near east door.

l Cribbouse - near south door.

l Off Gas Filter Building.

Reactor Building Ode Elevator.

Reactor Building Two Elevator.

Turbine Building Elevator.

Radweste Control Room.

Turbine Building One Trackway.

Turbine Building Two Trackway.

Shift Engineer's Office.,

O APPROVED d

COT 0 61953 Q.C.O.S.R. -. -

QEP 550-1 Revicica 3 b.

First Aid Eits.

s D

Maintenance Shop - wall.

Storeroce - locker.

Fuelh==diers office - well Rad Protection Foreman's Office - desk.

~

(

Instrument Maintenance Shop - wall.

Shift Engineer's Office - desk.

Reactor Building one Elevator - vall.

Reactor Building Two Elevator - wall.

Training Building - wall.

Main Office.

Personnel Decone==4=mtion area.

Turbine Building Elevator.

c.

Respiratory Equipment.

(1). Unit #1.

South Entrance LP Heaters and Condenser 595'0" Entrance to Turbine Blds by Diesel Generator 595'0" Entrance to Turbine Bids from Control Room 622'4" Entrance to Drywell, Personnel. Access 595'0" Exit free Reactor Blds Access Control Entrance South 595'0" Exit from Reacter Bldg Access Control Entrance East 595'0" Radwasta Control Room (2) Unit #2.

Entrance to Turbine Elds by Diesel Generator 595'0" Entrance to Drywell Personnel Access 595'0" Exit from Reactor Blds Access Control Entrance North 595'0" 2.

Personnel Deconem=4=mtion Area.

& 3 a.

The Personnel Decon*==4== tion Area is located on the ground floor of the Service Building. This area is easily accessible from the west hall leading from Unit I trackway and is adjacent to the employses locker room west entrance and is convenient to this

' location. The area is also convenient to the laboratory counting room and the radiation protection office. All cone==4nated personnel, including injured personnel, are to be decontaminated in this area. The following equipment is presently located in the decontamination facility:

APPROVED OCT 0 61983 q.c.o.s.w.

- 't i

l

l QEP 550-1 Revicica 3 (1) Decone =samtion shower (shower drain discharges to the reten-i tion tank).

(2) Sink and counter (drains to retention tank).

~

(3) Ready. supply of personnel monitoring instruments in Radiation Protection Instrument Storeroom.

(4) Station monitor for decone==4 nation check.

l (5) Washing machine and dryer for low-level personal clothing cone==4=ation in the Laundry Room adjacent to the personnel decone==4== tion room.

(6) Telephone.

(7) Soaps and detergents.

(3) Waste containers for cone==4==ted asterials.

(9) First aid kit.

G.

CHECILISTS 1.

None.

H.

TECHNICAL SPECIFICATION REFERENCES 1.

None.

\\

l l

l A P P RO'/ E C nd CCT 0 61953 o.c.o.s. k

- (final)

[

i

l

.a

-4 QEP 550-2 Revision 3 U

INVENTORY OF EMERGENCY EQUIPMENT September 1983 ID/2Y A.

PURPOSE

~

l The purpose of this procedure is to assure the availability and up-to-data calibration of equipment and supplies dedicated for use during energency situations.

B.

REFERENCES l

1.

QEP 550-T1, Environs Sampling Supplies.

2.

QEP 550-T2, Operational Support Center Emergency Supplies Cabinet.

3.

QEP 550-74, Emergency Operations Facility Supplies.

4.

QEP 550-T5, Technical Support Center Supplies.

'5.

GSEP, Section 8.'6.

l C.

r a SITES j

4p p gg,/E D l

2-OCT 0 31983 D.

PRECAUTIONS O. C. O. S. R 1.

None.

E.

I. IMITATIONS AND ACTIONS 1.

The equipment and supplies listed represent a

4n4==

quantity for

~

effective emergency use. Additional supplies may be present without being included on the inventory lists.

I 2.

The Radiation-Chemistry Foreman shall be responsible for assigning the l

task of inventory to the Radiation-Chemistry Technicians.

1 F.

Pm Inventory of environs sampling supplies:

1.

A quarterly inventory for the items listed in QEP 550-T1 shall be performed by the Radiation-Chemistry Department. Along with the l

inventory of contents, the instruments shall be removed and be recali-brated or replaced with like calibrated equipment. Should any contents be missing a Radiation-Chemistry Foreman or Health Physicist should be notified. Upon completion of the inventory the boxes should be secured to prevent unnoticed depletion of their contents.

1

,---,,,--,,.ne,,

--,n--.m,,--

,w_._-,,nm...,,

, -- ne,ey-,,,.

n-,---,w-.,,-,.,,m,_m.,,,,m.,

,,.----_.,,-r

'~'

QEP 550-2 Revision 3 2.

Inventory of the OSC emergency equipment cabinet:

v A quarterly inventory assuring the presence of all the items listed in QEP 550-T2 shall be performed by the Radiation-Chemistry Department.

Keys for the cabinet are available from all Radiation Protection management and the key cabinet located in the Radiagion-Chemistry j

Technicians' meeting room. Should any contents be missing a Radiation-Chemistry Foreman or Health Ph/sicist should be notified.

1 3.

Inventory of the control room:

A quarterly inventory of the station control room shall be performed by the Radiation-Chemistry Department to assure the presence and calibration of a " Cutie Pie" type dose rate instrument. This instrument

-should be. located within a plastic box on the south wall of the control room. Should this instrument be missing or out of calibration, a Radiation-Chemistry Foreman or Health Physicist should be notified.

4.

Inventory of the EOF emergency supplies:

A quarterly inventory verifying the presence of all itees listed in QEP 550-T4, as being stored in the EOF, shall be performed by the Radiation-Chemistry Department. A key for the EOF may be obtained from the Shift Engineer. If any of the contents are missing, a Radiation-Chemistry Foreman or Health Physicist should be notified.

5.

Inventory of the TSC emergency supplies:

A quarterly inventory verifying the presence of all items listed in QEP 550-T5 shall be performed by the Radiation-Chemistry Department.

A key for the TSC may be obtained from the Shift Engineer. A key to the emergency equipment cabinet is located in the-Rad-Chem Department's key cabinet. If any of the contents are missing, a Radiation-Chemistry Foreman or Health Physicist should be notified.

G.

CIECELISTS 1.

None.

E.

TECINICAL SPECIFICATION REFERENCES 1.

None.

i

.q

i APPROVED i

COT 0 6 E83 Y

o.c.o. s. a

.- (final)

'4 T-


m--

m-

- - + - - - ---wTNey ew-s-e*ee---w----t-f

QEP 550-T1 Q

' Revision 6

w. '

ID/1G ENVIRONS SAMPLING SUPPLIES September 1983 Inventory completed

  • signature /date Reviewed signature /date
  • Circle items missina from inventory DECON DESCRIPTION LOCKER #1 LOCKER #2 LOCIER #3 SURVEY INSTRUMENTATION High range cutie-pie ionization chamber (at least up to 50 R/hr) 1 1

Due Due GN survey meter ($,y) capable of measuring

<.02 mR/hr 1

1 1

Due Due Due Beta-samma probe HP-210 1

1 1

SH-4 sample holder w/H.P. 210 probe 1

1 Spare tube for H.P. 210 probe 2

2 Check sources for cutie pie 1

1 Check sources for GM survey meter 1

1 1

Spare batteries for C.P. instruments 4

4 Date Date Spare "D" cells for GN survey meter 5

5 5

Date Date Date SAMPLE TAKING EQUIPMEY.T Air sampler (operated either with battery or portable generator) 1 1

Due Due Particulate filter paper for air sampler 100 100 P-

)

Silver zeolit.e cartridges 25 25 s

APPRnvrr,

CCT 0 61933

~

-1 o.c. o.s. R.


ve.,

--,,-y

,r_

,-w-%y r-.-,--,y%.

,--..-,..,-.,_---.,,---.-,--,m--,,--2-~,-,y

-,e-,_

-m.-

-+--,w-

QEP 550-T1 Ravisica 6 y

e%

DECON j

DESCRIPTION LOCKER #1 LOCKER #2 LOCKER #3

~s Air sample data tags 50 50

~

Air sample plastic bags,_ approx. 3" x 8" 50 50 50' extension cord 1

1 Battery booster cables 1

1 Tripod fo'r air sampler 1

1 Swipes - bag terri towels 1

1 2

Nu-con type pesars w/ folder 50 50 50 Plastic bottles 10 10 Shovel - folding camp type 1

1 Plastic bags - appox. 12" x 18" 25 25 Plastic Sample Containers - approx. 1 qt.

10 10 PROTECTIVE CLOTHING Masking tape - 2" roll 2

2 2

Box of plastic gloves 1

1 1

Rubbers and shoe covers 3 pair 3 pair Disposable SWP coveralls 3

3 6

Rain gear (plastic disposable suits) 3 3

Head covers (surgeons caps) 3 3

i Full face respirators w/ combination filter / charcoal cartridges 3

3 Non-disposable SWP coveralls 3

3

' SAFETY EQUIPMENT Lantern 1

1 Spare 6 volt batteries for lantern 1

1 Date Date uPP90VED COT 0 61953

~ 0.C. O. S. R.

QEP 550-T1 R.vioics 6 DECON DESCRIPTION LOCKER #1 LOCKER #2 LOCKER #3 v

SAFETY EQUIPMENT (CONTINUED)

Spare bulbs for ianterns.

2 2

Safety flares 2

2 100' radiation rope 1

1 1

81AE HIE RADIATION AREA 4

4 HI E RAD AREA (CONTAMINATED) 4 4

RADIATION AREA 4

4 AIRBORNE RADICACTIVITY AREA 4

4 RADI0 ACTIVE MATRETAT.R AREA 4

4 4

RADIATION AREA (CONTAMINATED) 4 4

4 Radioactive materials stickers 30 30 30 v

First aid kit 1

1 1

DOSIMETRY SUPPLIES Film or TLD badges (for personnel dosimetry and/or area exposure acquisition) 12 12 Date Date 0-200 mR self-reading dosimeters 3

3 l

Color Color l

High range se'1f-reading dosimeters > 50R 3

3 l

Color Color l

l i

Dosimeter charger 1

1 Timekeeping los sheeta 3

3 C

APPROVED j

l OCT 0 61053 O. C. O. S. R. \\

's i

i l

t QEP 550-T1 Revinien 6 DECON DESCRIPTION LOCEER #1 LOCIER 42 LOCKER #3

%/

INFORMATION MATERIALS GSEP Book

~

I 1

1 Environmental Emergencv Procedures 1

1 Manual for GH survey instrument and CP's 1

1 1

Operating instructions for portable generators 1

1 Ares naps 1

1 Site maps 1

1 MISCELLANEOUS SUPPLIES Pockethnife 1

1 Scissors 1

1 Stop watch 1

1 Emergency log book 1

1 1

Clipboards and paper pads 2 em 2 ea 1

Felt tip markers 2

2 2

Pencils 6

6 6

American and Phillips screwdrivers and Allen wrench set 1 em 1 em 1 en Set of keys for environs stations and netro tower 1 en 1 es Plastic garbage bass 4

4 10 Bolt Cutters 1

1 2 Portable Generators (Storage Case)

Ladder (Storage Cage) 2 Walki-Talkies (Located in p

Rad-Chen Office)

Potassium Iodide Tablets 6 btis.

6 btls.

6 btis, I

aP P Roy s0 I

COT 0 6 Wo3 9.c.o.s.8.

~

QEP 550-T1 Revicion 6 DECON DESCRIPTION LOCKER #1 LOCKER #2 LOCKER #3 v'

DECON MATERIALS l

Package paper towels

.1 Scrub brush 2

Styrofoam cups 10 I

Plastic pails 2

Laundry soap 2 boxes 4% potassium permanganata 1

4% sodium bisulfate 1

n, APPROVED d

C^T 0 61053

n. c. o. s. a. (final) e-

QEP 550-T2 Revision 5 OPERATIONAL SUPPORT CENTER September 1983 EMERGENCY SUPPLIES CABINET ID/22 The cabinet labeled " EMERGENCY EQUIPMENT SIORAGE ONLY" located in the Operational Supponct Center (meting room adjacent to TSC) shall be. stocked with the listed protective equipment for usa in the event of an emergency when other such equipment is not available.

Requirements for cabinet:

Inventory completed

  • signature /date Reviewed signature /date
  • Circle items missina DESCRIPTION QUANTITT SWP Coveralls 6 Pair Rubbers 6 Pair-Shoe Covers 6 Pair Gloves 6 Pair Surgeon Caps 6

Hoods 6

Half Masks w/ Canisters 6

i Full Face Masks w/ Canisters 6

Masking Tape 2" 1 Roll Paper Towels 1 Pack l

Flashlights w/ Batteries 6

{

Date Rain Gear 6 Sets Surgeon Gloves 1 Box t

Pencil Dosimeters 500 MR 6

Color Pencil Dosimeters SR 6

Color GM Survey Instrument I

Due 1

s Cutie Pie Survey Instrument 1

Due APPRovEo C;T 0 61953 q.c.o.s. a.

i QEP 550-T2 j

R.viaica 5 i

r%

)

,j DESCRIPTION QUANTITY Potassius Iodide Tablets 48 btis.

GSEP Manual 1

Invironmental Emergency Procedures 1

Illinois Plan for Radiological Accidents 1

Peas 2

/

C.

J

.. P ? ?.C': E a C;T 0 61953 (final)

Q. C. O. S. M.

. - - - ~

(

m QEP 550-T3 Revision 3 v'

EMERGENCY SITUATION September 1983 FII21 DOSIMETERS IP '4R

^

~

I

.rgency film dosiswters 'shall be stored in green holders in the statio'as's r

, ardhouse and the two environs team lockers in the guardhouse. This film will~be distributed to personnel according to recommendations of the Rad-Chem Director.. Film used for environs monitoring will be distributed to locations according to recommendations of the environs director., Quantities of film are as follows:

LOCATION

  1. OF FII21 EUE DATE Guardhouse
  • 70 Environs I,ocker #1 12 Environs Locker #2 12 In case of an evacuation of station personnel, the emergency film will be transferred to the applicable access control point for the station.

D INVENTORY COMPIZIED Signature /Date REVIEnED Signature /Date 4

4 g

c.

o 0 i s-m n.. C. O. S. tt. (final) l I

- _..... - _, _.. _ _, _ _ _,. _.. ~ _...... _ _ _...., _ _ -, _ _ _ _ _. _. - _. _ _ _, _ _ _. _ _ _ _ _ _, _ _... _., _ _. _ _. _ _ _. _, -. _ _ _ _ _ _ _ _

~.

QEP 550-T4 S

1 Revision 4

'v EMERGENCY OPERATIONS September 1983 ID/4U FACILITF SUPPLIES

~

The emergency operations. facility is near Morrison, Illinois. The. inventory of supplies shall be completed quarterly.

Inventory Completed Signature / Data i

l Reviewed l

Signature /Date A - Stored at EOF.

B - Either stored at EOF or supplied to EOF upon activation as necessary.

C - Provided to EOF upon short notice (pre positioned for exercises).

DESCRIPTION QUANTITY CATEGORY SURVEY EQUIPMEFF i

Dose Rate Monitor (such as RM-16) #

Due 1

A Dose Rate Meter (CP) #

Due 1

A Con *==4 nation Survey Meter (GM) #

Due 1

A EP-210 Probe w/ Sample Holder 2

A Spare.3P-210 Probe 1

B Spare Batteries for CP and GM Date 1 set A

l Nu-Con faears 1 box A

Survey Sheets 10

.A SAMPLE TAEING EQUIPMENT Due l

Air Sampler Powered by Electrical Outlet 1

A l

Particulate Filter Paper for Air Sampler 100 A

Silver Zeolite Cartridges 20 B

i m.

A d / 2C'l 3. $

an s an

~

~

c.c.p.s.n.

,1

QEP 550-T4 Revicico 4 O

DESCRIPTION QUANTITY CATEGORY v

PROTECTIVE CLOTHING r

ANTI-C Clothing Sets * (various sizes) 90 B

Surgeons Gloves 1 box A

Cotton Glove Liners-90 pair A

Rain Gear 10 B

Lates Gloves 90 pair A

Masking Tape (2" rolls) 5 A

Full Face Respirator w/ Combination 50 B

Filter / Charcoal Cartridges Half Masks w/ Combination Cartridges 15 B

  • ANTI-C Clothing Set Includes:

1.

Coveralls 2.

Booties 3.

Rubbers 4.

Gloves 5.

Surgeons Cap SAFETY EQUIPMENT p

,(

Flashlights w/ Batteries Date 12 A

First Aid Kits 2

A Spare Bulbs for Flashlights 10 A

l Spare Batteries for Flashlights Date 10 A

l l

Radioactive Materials Stickers 50 A

Potassium Iodide Tablets 6 btis.

A

[

DOSIMETRY SUPPLIES Pencil Dosimeters 0-200 HR Color 50 B

Pencil Dosimeters 0-1 R Color 10 B

l Dosimeter Charger L

1 B

l Spare Batteries for Dosimeter Charger Date 2

A Film Dosimeters in Green Holders Date 50 A

(six month time limit on film) l p._

Timekeeping Los Sheets 50 A

APPFGVED

_ COT 0 61933,

l C. C. O. S. M.

.. _.... _ - _ _., _ _ _ _ _ _. _ _ _ _ _. ~ _.

QEP 550-T4 Revioica 4 3

D

.s DESCRIPTION QUANTITY CATEGORY CLERICAL SUPPLIES Transparent Tape 2 rolls A

Bulletin Board 1

B Bulletin, Board Fina (various colors) 3 boxes A

Easel and Pads (EOF) 3 A

Easel and Pads (Press Roon) 1 A

White Boards 2

A Pads of Paper 20 A

Clip Boards 5

A Three Part Note Paper 100 A

Pens (various colors) 10 boxes A

Pencils 5 boxes A

Pencil Sharpener 1

A White Board Markers (various colors) 10 A

A Paper Clips 2 boxes Staplers 2

A Staples 2 boxes A

Scissors 1 pair A

Window Cleaner I can A

Paper Towels 1 package A

Xerox Machina 1

3 Ierox Paper (reams) 10 B

Telecopier 1

B Telecopy Paper 250 B

Typewriter 1

B Typing Paper (packages) 2 B

Grease Pencils 1 box A

Spare Easel Pads 2

A ej

- APPao'/se CCT 0 61233

' O. C. O. S. k 6

QEP 550-T4 Revisics 4 r

9

/

DESCRIPTION QUANTITY CATEGORY v

INFORMATIONAL MATERIALS Procedure Set 1

A FSAR's 1

B ODCM 1.

A Environmental Emergency Procedures 1

A GSEP Manual 1

A Technical Specifications 1

B C.C.C. EPIP's 1

A Illinois Plan for Radiological Accidents 1

A P & ID's 1

B NARF Forms 50 A

Edison Phone Directory 1

A State Maps 2 sets A

Area May 1

A

~

Overhead Projector (Press Room) 1 A

Area Telephone Directories 2

B GSEP Phone List 4

A Iowa Plan for Radiological Accidents 1

.A COMMUNICATIONS EQUIPMENT NARS Phone (3reen) 1 A

CCC Dedicated Phone (yellow) 1 A

Microwave Radio Base 1

A Outside Line Telephones 8

A

~

Company Internal Network Telephones 5

A APPRO'/ED COT 0 61983

< }. C. O. S 9

QEP 550-T4 Ravinics 4

'v' DESCRIPTION QUANTITY CATEGORT MISCEIIANEOUS SUPPLIES Laundry Bass 4

A Respirator Sanitizer 2 boxes A

Paper Towels 4 packages A

Duct Tape (2" rolls) 2 rolls A

Lead Cave (small) 1 A

Extension Cord 1

B Plastic Bags (assorted sizes) 100 A

1 i'

l O

APPRO'/ED d

COT 0 61933

n. c. o. s. a. (final)

~

~

q QEP 550-T5 Revision 2

's TECHNICAL SUPPORT CENTER SUPPLIES September 1983 ID/4T The Technical Support Center shall be inventoried quarterly.

Inventory completed

'~~

Signature /Date Reviewed Signature /Date CATEGORIES A - Stored at TSC B - Provided to TSC upon short notice DESCRIPTION QUANTITY CATEGORY SURVEY EQUIPMENT 1

Dose Rate Monitor (such as RM-16) #

Due 1

A Dose Rate Meter (CP)

Due 1

A Cone==4n= tion Survey Meter (GM) #

Due 2

A a

HP-210 Probe 2

A Spars'HP-210 Probe 1

A Spare Batteries for CP and GM Date 1 set A

l Nu-Con Smears 1 box A

Survey Sheets 10 A

Ping Air Monitor Due 1

A j

Alpha Probe for GN 2

A PROTECTIVE CLOTHING ANTI-C Clothing Sets * (various sizes) 25 A

Surgeons Gloves 2 boxes A

Rain Gear 10 A

Masking Tape (2" rolls) 5 A

Full Face Respirator w/ Combination 25 A

Filter / Charcoal Cartridges Q

M P P.9 0 i

~ C OT 0 61053 n..C.O.s a.

..-. -..~-m

,_-...,-____,,-,_..,,__.,_,,y.-..

l l

QEP 550-T5 Revizica 2 b

DESCRIPTION QUANTITY CATEGORT SAFETT EQUIPMENT Flashlights w/ Batteries Date 12 A

l Firs't Aid Zit 1

B Spara Bulbs for Flashlights 10~

A Spare Batteries for Flashlights Date 10 A

l Radioactive Materials Stickers 50 A

Potassium Iodide Tablets 200 B

DOSIMETRY SUPPI,IES Dosimeter Charger 1

A Pencil Dosimeters 0-500 MR Color 10 A

Pencil Dosimeters 0-5 R Color 10 A

Spare Batteries for Dosimeter Charger Date 2

A Timekeeping Los Sheets 50 A

MISCEIIANEOUS SUPPLIES Paper Towels 4 packages A

l Duct Tape 2 rolls A

Extension Cord 1

B

  • ANTI-C Clothing Set Includes:

1.

Coveralls 2.

Booties 3.

Rubbers 4.

Gloves 5.

Surgeons Cap

.r ~

AP PRO'IE D V

COT 0 61983 0.c.o.s. 8

- (final)

.3

's I

'A 3

QEP 550-T6 Revisica 4

',,s/

ID/4R MOLINE PUBLIC HOSPITAL September 1983 RADIATICN EMERCENCY AREA SUPPLIES AND EQUIPMENT The following equipment and supplies will be stored at the Moline Public Hospital in the Radiation Emergency Area. This equipment and supplies are to be used in conjunction with the decone==4pation and treatment of radioactively cone==4nated patients at Moline Public Hospital.

If discrepancies are found, a Health Physicist should be notified. A quarterly inventory shall be performed.

An inventory should be performed after each use.

APPRO'/ED Inventory Completed Signature / Data CC7 0 s 1983 o

Reviewed Signature /Date

\\

'). C. O. S. R.

Requirements for Radiation Emerzency Area:

DESCRIPTION QUANTITY

(*,ount Rate Meter (PRM-4A or equivalent) with HP-210 probe.

Due 1

" Cutie Pie" Ion Chamber i

Due 1

i Spare Probe for HP-210 1

3 Self-reading Dosimeters, 0-200 mR Color 10 0-IR Color 4

Film Badges Date 10 Finger Ring Badges Date 6

s Dosimeter Charger 1

Batteries, 9 V Transistor Date 4

1.5 V D-cell, Date 5

15 V Photo / Electronic Date 1

1.5 V "AA" Date 2

12 packages Protective Clothing:

Gowns, disposable Gloves, surgical sterile non-sterile Plastic Aprons Shoe Covers, disposable i

Face Masks s

Head Covers

~

r 3

Sheets, barrier, disposable 1

Basic Pack II

w
  • 1

.~....__..,_.,.-_,.---..::..-....-,--.., -

QEP 550-T6

~

Revision 4

}

7 DESCRIPTION QUANTITY Towels, disposable 2 packages Pre-cut I,abels 50 Shield, mobile, lead glass 1

Deconta=4=mtion kit 1

Sasple Taking Kit 1

Step-Off Pads 2 sets Radioactive Truck Placards 4

Signs:

?

" Caution Radioactive Material" 2

"Righ Radiactivity Area Signs" 2

'"Eigh Ratistion Area" 2

"Radioactiv? Material" 3

1 4

" Airborne Radioactivity Area" 2

't

" Radiation Area - Radioactive Material" 2

~

Decone==4== tion' Table Top 1

Water Receptacle, 30 gallon 1

Iead Container 1

I Trash can (for conta=4=mted articles) 1 Radiation Accident Posters 1

E.

Showerhead and Retractable Hose 1

s.

Kraft Paper or Pyrokare 1 roll Respirator, 1/2 mask 9

Radiation Warning Rope 50 ft.

Herculite, (sized as per REA procedures) or plastic floor covering i each Radiation Tags:

(.

" Caution Radioactive Material" 20 "Unconditiona1 Release" 20

.e

, M F FitO V r 0 CCT 0 61953 2-9.c.o.s. a.

, -. < - ~,. - - -,,,,,,-

,~.,,,,w,.,

,.,,,,,--,-,--,n

~,,.,,,,,. - - -, -... - - -

,,-n...~

n,-,

a.-,m.,e-,,-~,-,.,,.n,-,,e_n-,-,,-wn

QEP 550-T6 Revicion 4 DESCRIPTION QUANTITY w

Radiation Stickers:

" Caution Radioactive Material" 20 g

" Contaminated Clothing" 20 Plastic' Bass:

small 20 nedium 20 large 20 Cotton Balls I box Manual: " Decontamination of an Injured and Cone==4nated Patient" 1

l b

s l

1 O-APPROVED

)

6 CCT 0 61983

. (final)

~

~

i i

, --