ML20090C429

From kanterella
Jump to navigation Jump to search
Forwards Rev 0 to Procedure T-250, Remote Manual Primary Containment Isolations, in Support of Resolution of SER License Condition 5.Listed Containment Isolation Valves Will Receive Diverse,Automatic Isolation Logic by First Outage
ML20090C429
Person / Time
Site: Limerick  
Issue date: 07/10/1984
From: Kemper J
PECO ENERGY CO., (FORMERLY PHILADELPHIA ELECTRIC
To: Schwencer A
Office of Nuclear Reactor Regulation
Shared Package
ML20090C431 List:
References
OL, NUDOCS 8407130296
Download: ML20090C429 (3)


Text

,

i.

PHILADELPHIA ELECTRIC COMPANY 2301 MARKET STREET P.O. BOX 6099 PHILADELPHIA. PA.19101 0W JOHN S. KEMPER VICE# RESIDENT ENG8MEE NING ant 1 NESE ARCH Mr. A. Schwencer, Chief Docket Nos.:

50-352 Licensing Branch No. 2 50-353 Division of Licensing U. S. Nuclear Regulatory Comission Washington, D.C. 20555

Subject:

Limrick Generating Station, Units 1 and 2 Mditional Infonnation for Containment Systems Branch (CSB) Regarding SER License Condition #5: Mdition of Autanatic Isolation Signals to Reactor Enclosure Cooling Water (RECW) and Drywell Chilled Water (DCN)

Isolation Valves

Attachment:

Procedure T-250, Revision 0: Remote Manual Primary Containment Isolations File:

GOV" l-1 (NEC)

Dear Mr. Schwencer:

We are pleased to provide the following infonnation in support of the resolution of SER license condition #5.

Sections 4.1 and 4.9 of the attached procedure provide special operating instructions to encure appropriate closure, following an accident, of the remote manual containnent irolation valves associated with:

(1) PECW supply to the recirculation pmp seal coolers (HV13-106, 108)

(2) PECW return fran the recirculation pump seal coolers (hV13-107, Ill)

(3) DCW supply (HV87-120A, B)

(4) DCW return (hT87-121A, B)

(5) RECW backup supply to drywell coolers (HV87-125 A, B)

(6) RIXM backup return fran drywell coolers (HV87-124A, B) l i

8407130296 840710 l

PDR ADOCK 05000352 E

PDR

e '

As noted in FSAR Table 6.2-17, the above containment isolation valves will receive diverse, autcratic isolation logic by the end of the first refueling cutage.

Should any additional infonration be required, please do not hesitate to contact us.

Sincerely,

{d,. 6' JIIA/gra/06288407 cc: See Attached Service Idst L

f.

cc: Judkje Inwrence Brenner (w/o enclosure)

Judge Pichard F. Cole (w/o enclosure)

Troy B. Conner, Jr., Esq.

(u/o enclosure)

Ann P. Ecdgdon, Esq.

(w/o enclosure)

Mr. Frank R. Rmano (u/o enclosure)

Mr. Robert L. Anthony (w/o enclosure)

Charles W. Elliot, Esq.

(w/o enclosure)

Zori G. Ferkin, Erg.

(u/o enclosure)

Mr. Thamas Gerusky (w/o enclosure)

Director, Penna. Emergency (u/o enclosure)

Managctnent Agency Angus R. Inve, Esq.

(u/o enclosure)

David Wersan, Esq.

(w/o enclosure)

Robert J. Sugarman, Esq.

(u/o enclosure)

Spence K. Perry, Esq.

(u/o enclosure)

Jay M. Gitierren, Esq.

(w/o enclosure)

Atcznic 6fety & Idcensing (w/o enclosure)

Appeal Peard Atcmic Safety & Licensing (w/o enclosure)

Board Panel Docket & Service Section (w/o enclosure)

Martha W. Euch, Esq.

(w/o enclosure)

Mr. James Wiggins (w/o enclosure)

Mr. Tinnthy R. S. Caqiell (w/o enclosure)

Ms. Phyllis Zitzer (w/o enclosure)

Judge Peter A. Morris (w/o enclosure) t k'-