Rev 3 to Procedure 1-PT-46.2A, Condenser Air Ejector Radiation Monitor Alarm Setpoint Calculation
ML20090B574
Person / Time
Site: Ginna 
Issue date: 10/02/1987
From:
VIRGINIA POWER (VIRGINIA ELECTRIC & POWER CO.)
To:
Shared Package
ML20090B375 List:
References
FOIA-91-106 1-PT-46.2A, NUDOCS 9203030467
Download: ML20090B574 (8)


Text

._. _.

RIQUEST TO CHANGE PROCEDURE arm-5.4 NORTH ANNA POVER STATION 71RGINIA P0kTR Page 1 of 1 07-09-87 I. ATPERVISOR RESPONSIBLE NR POLLOVING PROCDURE:

1 O ABNORMAL O CURVE B00E O OPERATING O kTLDING O ADMINISTRATIVE O EMERGENCY

$ PERIODIC TEST O

O ANNUNCIAICR O IN-SERVICE INSPECTION O HEALTE PHYSICS g

O CALIBRATION O MAINTENANCE O SPECIAL TEST O

O CnDfISTRY O NON-DESTRUCTIVE TEST O START-UP TEST O

PROCEDURE NO: / - g,.

2 UNIT No:

3 RTVISION DATE:

ypp pg, T1nEs

[o ),,,,,

j;,

g)*cle r lE $ts4-% Me.,;w Atua c hv k

(. i,.i. f w Q

CHANGES REQUESTG:

(GITI STEP NUMBER, EIACI SUGCESTED WORDING AND LIST RIPERENCES. STAPLE COPY OP PROCIDURE WITH SUGGESTED CHANGES MAREED TO THIS PORM.)

M Fw P 2 cc r o u R tE RETERENCES:

fn!<de $ % i b i 4'. %

W VC.7A, afpro o ri IdN4 )

t~

RAASON POR CHANGES:

7 A

7 GE REQUESTED ST:

8 DATE:

9 ACTION TAKIN:

~

10 XES THIS CHANGE THE OPERATING METHODS AS DESCRIBED IN TEP. UFSARr' C YES 3 NO DOES THIS CHANGE INVOLVE A CHANGE TO THE TECH. SPECS /

O TES 3 NO DOES THIS CHANGE INVOLVE A POSSIBLE UNREVIEVED SATITY QUESTION /-

O TIS 3.NO IP ALL "NO", NO "$ATETT ANALYSIS" IS REQUIRED.

IP ANY "TES", A " SAFETY ANALYSIS" IS REQUIRID.

(10CTR50.59) APPROVED COPY TO BE PROVIDED TO LICENSING COORD. POR INCLUSTON IN ANhTAL REPORT.

RECO. WINDED ACTION:

1!

M PROVED O DISAPPROVED

~

DOES THIS PROCEDURE CREATE A QA DOCUMENT /

TES S NO-C BT (COGNIZANT SUPERVISOB) 12 DATE:

13 REVIEkT.D ST QUALITT ASSURANCE:

CHANGES MADE TES O NO O -

14 BY:

M cehw F*@

15 DATE 10 7g REVIEWED Y TATION NUCLEAR SAitu AND OPERATING COMMITTEE:

17 APPROVED O DISAPPROVED O APPROVED AS MODIPIED BY CC.WITTEE 1 4RMAN SIGNATURE:

18 DATE:

/p 19 NEW PROCEDURE REVISION DATE:

/

ACTION CCKPLETED BY:

21 DATE:

' 22 9203030467 910819

' ~ ~ '

PDR FOIA

m "/ '

o 7

WILLIAM 91-IO6 PDR

'/'Uj v

'i"/

~

. - _ - - - ~. - _.

~.

-. - ~

4 a

PERIODIC TEST CRITIOUE NORTH ANNA POWER STATION VIRGINIA POVDL Periodic Test No 1

Io be Performed By:

2 Unit No J

1-PT-46.2A SRIFT TECHNICAL ADVISOR

_1,,

1 Test Titles 4

CONDENSER AIR EJECTOR RADIATION HONITOR ALARM SETPOINT CALCUIATION 3

i Tei.t frequency:

5

$PECIAL Unit Conditions Requiring Tests 6

MODE 1 s

Test Performed By:

7 Date Started: 8A Data Completed: 88 Test Results (To be completed by performer of test and Cognizant 9

Supervisor (s)):

1.

/ _ / Satisfactory

/

/ Unsatisfactc,7

/

/ Partial Procedure

2. The following problem (s) was encountered (use back of sheet for additional space):
w. -
3. Corrective actii..t taken or initiated:
4. Work Order No.:

Dated:

Porvard to Cognizant Supervisor i

Test Reviewed and Approved By Cognizant Supervisor (s) or Designee:

10 Dates Reactor Engineer Dates Supervisor, Sury. 6 Test Consents:

Forward To Performance Engineer Comment (s) of Performance Engineer:

11 Stamps 12 l

t F

-7...

,o

=.

~

.,~

I 1-PT-46.2A Page 1 of 4 00-00-00 VIRGINIA POWER PERIODICTESTPROCED$.EPORNORTHANNAPOVERSTATIONUNITNO.:

1 TITLE: CONDENSER AIR EJECTOR RADIATION MONITOR ALARM SETPOINT CALCULATION

REFERENCES:

1.

1-PT-46. 2 2.

Calculational Basis for PT-46.2A, approved 10/1/87 (See Rev. 0) 3.

Letter to the NRC, 9/15/87 (serial no. 87-474A)

REVISION RECORD:

APPROVED CRAIRMAN STATION NUCLEAR SAFETY

,RIV.

NO.

PAGZ(S)

DATE AND OPERATING COMMITTEE l

l I

i i

RECOMMENDED APPROVAL:~

l APPROVED BY:

1 CHAIRMAN STATION NUCLEAR SAFETY AND OPERATING COMMITTEI DATE:

SUPERINTENDFNT TECHNICAL SERVICES 1

l l

l

\\

m

.-. =- -.

~ -.. --- -.

-.. _ - -. ~.. _

1-PT-46.2A Page 2 of 4 00-00-00 Initials 1.0 Purpose To determine the Condenser Air Ejector Radiation Monitor (1-RM-SV-121)

"HIGH" alarm setpoint, based on primary-to-secondary leakage, omamme 2.0 Initial conditions NOTE: If this is an initial startup, then previous pts may not be available.

2.1 The trend of the condenser air ejector radiation nordtor count rate from 1-PT-46.2 is available.

NOTE: If this is an initial startup, or a restart following a steam generator tube plugging outage, the initial leak rate is assumed to be 0 spd.

2.2 The S/G 1eak rate data from 1-PT-46.2 is available.

3.0 Precautions and Limitations 3.1 This trocedure must be performed prior.to entering Modo 1.

3.2 For an initial sta'rtup, or a plant startup following a S/G tube plugging outage, the previous S/C leak rate is assumed to be 0 spd.

3.3 For a plant startup, estimate the RCS gas activity, for 30% power, or any power level that the plant is arpect4d to operate at for an extended period, whichever is less.

3.4 To recalculate the air ejector radiation monitor (1-RM-SV-121,)

"HIGH" alarm setpoint, use the most recent measured RCS gas activity isotopics, if possible, or applicable. Otherwise estimate the RCS gas activity isotopics based on previous measured data and power history.

~r w

,y.,

.,.e-

-ww

+*w-=~=-*

i-m

-=-M

'ei w-~

p y

w---ev-'r-er P--

vP

=-t=-w+

'-g t'

~ __ _

1-PT-46.2A Page 3 of 4 00-00-00 3.5 To recalculate the air ejector radiation monitor (1-RM-SV-121)

"HIGH" alarm setpoint, use the most recent leak rate calculations based on 1-RM-SV-121. Several leak rate results may be averaged to better ascertain the primary-to-secondary leak rate.

4.0 Instructions 4.1 Record the most recent psimary-to-secondary leak rate data (based on 1-RM-SV-121) from 1-PT-46.2 on Attachment 6.1.

If this is a startup af ter a S/G tube inapection outage, record 0 spd total leakage on Attachment 6.1.

4.2 Estimate the RCS gas activity based upon previous measured data and the power history. Use 1-PT-46.2 (Atta'chmen't 6.10) for guidance. Record the estimated RCS gas activity on Attachment 6.1.

Recy$

4.3 rd the previous "HIGH" alarm setpoint for 1-RM-SV-121 on y

A;t'achment 6.1.

4.4 Record the current total Condenser Air Ejector Flow Rate on

..1.

4.5 Record the current count rate for 1-RM-SV-121 on Attachment 6.1.

4.6 Calculate the new *HIGH" alarm sstpoint for 1-RM-SV-121 using the equations at the Sottom of Attachment 6.1.

4.7 Immediately notify the Shif t Supervisor of the new alare setpoint.

4.8 Complete Attachment 6.2 and forward a copy to the Health Physics Shitt Supervisor.

l 4.9 Verify that the new setpoint has been implemented.

1 l

6

+$-

se -m-e 7w-1

--my-r-

r-e e

c- -. --

w,-yew

-m-,

2--

,w 4


r

-,r----

-->yw

1-PT-46.2A Page 4 of 4 00-00-00 4.10 Post an Operator Aid (ADM-19.27) next to 1-PJi-SV-121 stating the new setpoint in both cpe and gpd.

$.0 Acceptance Criteria 5.1 The new setpoint has been implemented and an Operator Aid has been posted.

6.0 A*.tachments 6.1 1-RM-SV-121 "HIGH" Alarm Setpoint Calculation 6.2 Memo to change the "High" alarm setpoint for 1-RM-SV-121.

4 4

4 e

e i

l i

I 1-PT-46.2A.1 Page 1 of 1 00-00-00 1-EM-SV-121 *EIGH" Alarm Setpoint Calculation Recent Primary-toSecondary Leak Rate Data Based on 1-RM-SV-121 (from 1-PT-46.2):

Date(s):

Leak Rate (s):

Averages gpd RCS Gas Activity (uci/ gram)

Hessured:

Date:

Times Powers Xe-135:

Kr-87:

Ar-41:

Estimated Fort Date Times Powers Xe-13$:

KR-87:

Ar-41:

Total Condenser Air Ejector Flow Rate SCFH Current Count Rate for 1-RM-SV-121:

cpm Previous "RIGH" Alarm Setpoint s cpa This corresponds tot gpd e

New "HIGH" Alarm Setpoints eps This corresponds tot gpd eIf 1-RM-CV-121 is less than or equal to 80 cpm Setpoint (cpm) = 80 +

(20 rpo) (Ke-135 + Kr-87 + AR-41)

(2.92 x 10~4)(Air Ejector Flow Rate) e If 1-RM-SV-21 is greater than or equal to 80 cpa Setpoint (eps) = 80 + (leak rate + 10 rpd)(Xe-135 + Kr-87 + Ar-41 (2.92 x 10"#)(Air Ejector Flow Rate)

PREPARED BY:

DATE:

.__._______-_-m__m,

- - - - - " ' ' ~ - - - - - " - - - ' - - - - - - - - - - - - - ' - - - - - - - - - - - - - - - - - -

' ~ -

1-PI-46.2A Attachnent 6.2 Page 1 of 1 00-00-00 MDO TO CHANGE THE *HICH" ALLEM SETPOINT TO 1-RM-SV-121 TO: Health Physics Shif t Supervisor North Anna Power Station PROM Shif t Technical Advisor Date Please immediately update the "HIGH" alarm setpoint to the Unit 1 Condenser Air Ejector Radiation Monitor (1-PJi-SV-121) as soon as possible, as follows:

Setpoint =

cpm This corresponds tot gpd 1

Date Shilt Technical Advisor

.-