s e

r e pg DEFENSE NUCLEAR AGENCY

+

ARMED FORCES R ADIOBIOLOGY REsE ARCH INsitTUTE

+

8ETHEsD A, MAPYLAND 20814 k9 00521 MAY 2 i H a RSDS Thomas T. Martin, Director Division of Engineering and Technical Programs U.S. Nuclear Regulatory Commission Region 1 631 Park Avenue King of Prussia, PA 19406

Dear Mr. Martin:

This is in reply to your letter of 17 Apr 1984, subject: Emergency Preparedness Appraisal 50-170/34-01.

We have considered each of the four " improvement areas" identified in your report, Appendix A, " Emergency Preparedness improvement items" and have taken the following actions regarding each item:

1.

Emergency Preparedness Training:

We considered your recommendations of development of a training manual and of lesson plans and have decided to develop separate lesson plans for each group of response personnel. These lesson plans will be kept in a binder which will r,erve as the training manual. As part of the training program, provisions will be made for scheduling of training, attendance records, and lesson objectives. Off-site personnel training will place special emphasis on the biological effects of radiation.

The lesson plans we are developing are to be completed by 1 September 1984.

The training of reactor operators on control room habitability in emergency situations has been completed.

2.

P. ement of Run Cards on Response Fire Engines: Your recomment'ation has been implemented.

3.

Changes to Emergency Plan: Your recommendations were deemed acceptable, and changes have been approved and distributed.

4.

Evacuation Route Diagrams: Your recommendation was approved by the AFRRI Occupational Health and Safety Committee and is being implemented with an estimated completion date of 1 September 1984.

6407110229 840627 gDRADOCK 05000170 PDR

7

.4-

)

i 1-e.

gp~m-RSDS

~ '" '

Thomas T. Martin, Director.

3 j :l ' j

~ j.l g

Should you have any further questions concerning this matter, feel free to call me at (301) 295-1210 or the reactor staf f at (301) 295-1290.

Sincerely,

/

.ADCOCK C onel, MS, USA Director 2

>