Application for Amend to License NPF-7,changing Tech Specs to Delete Surveillance Requirement 4.8.1.1.2.c.6 Re Simulated Loss of Diesel Generator W/Offsite Power Unavailable,Per Generic Ltr 83-30
ML20087F710
Person / Time
Site: North Anna 
Issue date: 03/15/1984
From: Stewart W
VIRGINIA POWER (VIRGINIA ELECTRIC & POWER CO.)
To: Harold Denton, John Miller
Office of Nuclear Reactor Regulation
Shared Package
ML20087F714 List:
References
130, GL-83-30, NUDOCS 8403190201
Download: ML20087F710 (3)


Text

7 c

m VIROINIA ELECTHIC AND Powan COMPANY Ricnwonn,VrmorxrA 20261 W.L. STEWART Vsem Pasesomwr wuct=*. o,.

rion.

March 15, 1984 Mr. Harold R. Denton, Director.

Serial No. 130 Office of Nuclear Reactor Regulation N0/JHL:aca Attn:

Mr. James R. Miller, Chief Docket No. 50-339 Operating Reactors Branch No. 3 License No. NPF-7

Division of Licensing U. S. Nuclear Regulatory Commission Washingtcn, D. C. 20555 Gentlemen:

VIRGINIA ELECTRIC AND POWER COMPANY NORTH ANNA POWER STATION UNIT NO. 2 PROPOSED TECHNICAL SPECIFICATION CHANGE Pursuant to 10 CFR 50.90, the Virginia Electric and Power Company requests an amendment in the form of a change to the Technical Specifications, to Operating License No. NPF-7, for North Anna Power Station Unit No. 2.

The proposed Technical Specification change will delete surveillance requirement 4.8.1.1.2.c.6 which requires verification that on a simulated loss of the' diesel generator (with offsite power not available), the loads are shed from the emergency busses and that subsequent loading of the diesel generator is in accordance with design requirements.

This proposed Technical Specification change is being performed in accordance with NRC Generic Letter No. 83-30, dated July 21, 1983.

In addition, the preceeding surveillance requirements are renumbered appropriately.

The proposed Technical Specification change for North Anna Unit No. 2 is provided in Attachment 1.

A discussion of the proposed Technical Specification change is provided in.

This request has been reviewed and approved by the Station Nuclear Safety and Operating Committee and the' Safety Evaluation and Control Staff.

It has been determined that this request does not involve an unreviewed safety question as defined in 10 CFR 50.59 and does not pose a significant hazards consideration as defined in 10 CFR 50.92.

We. have reviewed this request in accordance with the criteria in 10 CFR 170.22. Since this request involves a safety issue which the Staff should be 8403190201 840315 th PDR ADOCK 05000339

\\

P-PDR

r_1 hih t

VamonwtA En.actanc Awa Pows Courawv to Harold R. Denton i

able to - determine does not. involve a significant ' hazards consideration for

. Unit 2, a Class III license amendment fee is required. A voucher check in the amount of-$4,000 is enclosed in payment of-the required fees.

Very truly yours, FM W. L. Stewart

~

Attachments:

-1.

Proposed Technical Specification Change

'2.

Discussion of Proposed Technical Specification Change L--

3.

Voucher Check for $4,000 cc:

Mr. James P. O'Reilly-Regional Administrator Region -II Mr. M. W. Branch

NRC Resident Inspector

- North Anna-Power Station Mr. Charles Price Department of Health 109 Governor Street

-Richmond, Virginia 23219

( :.

t g

L-L p

1 COMMONWEALTH OF VIRGINIA )

)

CITY OF RICHMOND

)

The foregoing document was acknowledged before me, in and for the City and

' Commonwealth aforesaid, today by W.

L.

Stewart who is Vice President Nuclear Operations, of the Virginia Electric and Power Company.

He is dfly authorized to execute and file the foregoing document in behalf of that Company, and the statements in the document are true ' to the best of his knowledge and belief.

r4 Acknowledged before me this /I day of M -

, 19 Y My Commission expires:

2 J4

, 19 V.

[L d-. - M Sh Notary Public 1

(SEAL)

S/001

,e m