LEGAL CEPARTMENT RELATED C0RnES70NDENCE

'*"a"-

" " ' " ' ~ * ' ' "

  • ~ ~ * * ~ ' ~ ~ ' "

and Gearvel Censued J E i.

Jad' ' *"=a 00CHET_E0 e--

O-g AHen 8 Sees C8eertos O Dewoon Q* g 6b b

O K Peterson

.hseine W Dempeey

(

f WMsvi E Wiener Joam P Dichey W

Masorgird Ausrverys Cannerine M Gleeson u.

y CUIil,Ue'td George F Hall 14 MAR 15 A10:40

y, Howard E Ciert Sween Kat Secondy E Magen Weyvie A Kerktry David A Maheanne Freak R Knos Scouer Anorierry James W Koessier I,F F G ;;
E q T,

Fr.sens A Lomain rv.,-- - - e - -

a*

Cao.g A Marks Generes omces: 212 West Menesen Avenue. Jeckson. M8 49201 o'fM 7)!?BP '0550..

Aie.ri D Mec.n.a

      • 'N**.

poues H une wni.r s Direct Dial Number e (517) 788-1257 R n M ue.e.

v ne.n p r,o.-.n.

Dead R Rood Gregory A Sendo March 12, 1984 17@"

Desmes L V.pleone Theoeore J Vogei M.cne a w n Arrorners Dr. Frederick P. Cowan 6152 N. Verde Trail Apt. B-125 Boca Raton, FL 33433 Mr. Charles Bechhoefer, Esq.

Dr. Jerry Harbeur Atomic Safety & Licensing Atomic Safety & Licensing Board Panel Board Panel U.S. Nuclear Regulatory Commission U.S. Nuclear Regulatory Commission East-West Towers East-West Towets Room E-413 Room E-454 4350 East-West Highway 4350 East-West Highway Bethesda, MD 20014 Bethesda, MD 20014

Dear Board Members:

At Tr. 08861, Mr. Donald Lewis of Bechtel presented testimony concerning a buried, control-room pressurization pipe which was to be evaluated for the possibility of corrosion due to stray welding currents. The attached report of Bechtel contains such an evaluation, and finds that corrosion because of stray welding currents is not of concern with respect to this pipe.

Very truly yours, p

yy

[

mes E. Brunner CC OM/0L Service List Attachment 8403190166 840312 PDR ADOCK 05000329 C

PDR l

Ia Revised 3/12/84 UYYf OM/OL SER4TCE LIST nn R 1 5 g o _.4 9 CFFr :. --

Mr. Frank J. Kelley, Esq.

00Cif Mr,., jteve' Gadler Attorney General of the 212%CCirter Avenue State of Michigan St. Piul, MN 55108 Ms. Carole Steinberg, Esq.

Assistant Attorney General Atomic Safety & Licensing Environmental Protection Div.

Appeal Ecard 720 Law Building U.S. Nuclear Regulatory Commission Lansing. MI 48913 Washington, DC 20555 Mr. Myron M. Cherry, Esq.

Mr. C. R. Stephens, Chief Cherry & Flynn Docketing & Services 3 First National Plaza U.S. Nuclear Regulatory Commission Suite 3700 Office of the Secretary Chicago, IL 60602 Washington, DC 20555 Mr. Wendell H. Marshall Ms. Mary Sinclair 4625 S. Saginaw Road 5711 Summerset Street Midland, MI 48640 Midland, MI 48640 Mr. Charles Bechhoefer, Esq.

Dr. Jerry Harbour Atomic Safety & Licensing Atomic Safety & Licensing Board Panel Board Panel U.S. Nuclear Regulatory Commission U.S. Nuclear Regulatory Commission East-West Towers East-West Towers Loom E-413 Room E-454-4350 East-West Highway 4350 East-West Highway Bethesda, MD 20014 Bethesda, MD 20014 Dr. Frederick P. Cowan Atomic ~ Safety & Licensing Atomic Safety & Licensing Board Panel Board ranel U.S. Nuclear Regulatory Commission 6152 N. Verde Trail Washington, DC 20555 Apt. B-125 Boca Raton, FL 33433 Mr. Michael Miller, Esq.

Mr. William D. Paton, Esq.

Isham, Lincoln & Beale Counsel for the NRC Staff l

3 First National Plaza U.S. Nuclear Regulatory Commission Suite 5200 Washington, DC 20555 Chicago, IL 60602 Mr. D. F. Judd Mr. Frederick C. Williams Senior Project Manager Isham, Lincoln & Beale The Babcock & Wilcox Company 1120 Connecticut Ave., N.W.

P.O. Box 1260 Suite 325 Lynchburg, VA 24505 Washington, DC 20036 i

l 1

3r

i*

OM/OL Sarvice List (Cont'd.)

Page 2 Ms. Barbara Stamiris Ms. Lynne Bernabei 5795 North River Road Government Accountability Route 3 Project of the Institute Freeland, MI 48623 for Policy Studies 1901 Q Street, N.W.

Washington, DC 20009 Mr. John Demeester, Esq.

Mr. James E. Brunner, Esq.

Dow Chemical Building Consumers Power Company Michigan Division 212 West Michigan Avenue Midland, MI 48640 Jackson, MI 49201 Mr. P. Robert Brown, Jr.

Clark, K1cin & Beaumont 1600 First Federal Building 1001 Woodward Avenue Detroit, MI 48226 l

l l

I I

~

APu:chal c. h.,... :.Qdf dWSicgsr TO: C. EAGLE intrich RAWello i40694

,,os,

,,3,,ogg, tEosvis JLWood QUALITY ACTION b

JAHorsch Q0p.f.'j5W REQUEST

,3gg-IMHughes MWKirkland l

slu: OCLE AIf: A8065 Fro m WRBird/GREagle b

To:

@ Control Document ref.:

@ QAR Ideg. No.:

EHHughes

_SCRE 12 M-'2 Bechtel Project Engineering's response to Consumers Power Company Safety Concern and Reportability Evaluation (SCRE) 12 (Com 084409) indicated that all buried, safety-related, stainless steal lines had been identified, inspected, and evaluated for reportability. A subsequent investigation has identified another buried, safety-related, stainless steel line (1"-OCCC-001).

In light of this discovery, you are requested to address the following:

,s

1) Based on the specific location of the line, the type of stainless steel, the potential for an adverse effect of stray velding current corrosion on buried stainless steel lines, and prior evaluation results, determine the need for I

any inspectica and/or evaluation of the identified line.

(See page 2) l Signato e bef U/2 t$if.) @

Date:

@ Reply Recuest by:

11l2Il82

/L//7 l

Reply:

M g

1 Project engineering's revised complete response is attached.

1 m

Senature:

@ Date:

Q Action verif sa:

1 Q Date:

g l

e 6

j QAR M-72 Page 2 094892 140694 Action Requested (con't.)

Schedule and implement the action specified.

i

2) Provide documentation indicating that all buried, safety-related

, stainless steel lines requiring evaluation under SCRE 12 have been identified, evaluated, and dispositioned.

O e

e e

O e

a e

" ' ' ' ^ " '

~---

.,. e e

Revised Response to

?

QAR M-72 AI A-8065 Page 1 of 2 this is project engineering's revised complete response to QAR M-72.

This response supersedes project engineering's complete response dated January 6, 1984.

1.

The actual corrective cetion taken to eliminate stray weldinc current was addressed in a memorandum to all welders, which outlined the requirements for grounding welding machines when welding in the yard. This memorancum was issued at the jobsite on March 31, 1981, and was subsequently added to the General Jhk Guidelines for Welders.

All new welders are required to read the guidelines and sign to acknowledge their understanding of the content.

L 2.

The date of corrective action implementation was March 31, 1981.

3.

Line OCCC-1 was installed January 15, 1981, and pneumatically tested at 2,750 psig or. January 28, 1981. Review of daily field engineer reports for se:1s work at the jobsite indicates that line OCCC-1 wa: not backfilled until after April 2, 1981. This was after the memorandum outlining the requirements for grounding welding machines was is ued, thus reducing the chance of stray welding current corrosien.

Borated water storage tank discharge lines 18"-1HCB-1, 18"-1HCB-2, 18"-2HCB-1, and 18"-2HCh-2 have been excavated and inspected in the area close to the plcnt grounding grid.

The location was chosen as the likeliest to have experienced corrosion.

The inspection disclosed no evidence of corrosion. Thus, it is concluded that the likelihood of corrosion is low for other lines, i

specifically for line OCCC-1.

Line OCCC-1 is the fill line for control room pressurization tanks OVT-28A and OVT-28B. These tanks are equipped with a common pressure indicator, OpI-6581A, and a low-pressure alarm.

OPAL 658.*

If line OCCC-3 is corroded sufficiently to cause j

f ailure.ind leakage at pressure, the pressure indicator and alarn would it ediately indicate to operating or test personnel that action it required.

I Because the likelihood of :orrosion is low and a failure woulc be readily detectable, no further inspection or evaluation of installed line OCCC-1 is necessary.

Re /d E.B. Poser Project Engineering Manager

~

RCH/MRS/Imm(ti) l l

l 0695b

,,v--

_,.---e.

,-,._m...

x,--_

. -. r..

.-_.--...n

. ~. - -.

a s*

Revised Response to QAR M-72 Al A-8065 Page 2 of 2 140694 cc:

W.R. Bird D. Jones T.K. Postlewalt H.W. Slager bec:

.T. Ballweg M. Dietrich T. Foote R.C. Hollar B. Kappel Vrltten Response Requested:

No com Use:

NA l