rr ll 1:
" DukeIbeberCompany T. C Aictitra AkGuire Nudear Generation Department Vicehrsident 12700Hagers TerryRoad(h!GOnP)
(764)8is4800 Huntersuille,NC280iSDS5 (704)8754809 Fax '
DUKEPOWER August.2, 1995
-U..S. Nuclear Regulatory Commission Document Control-Desk Washington, D.C.
20555
Subject:
McGuire Nuclear Station, Docket 50-370 Unit 2 Steam Generators December 1994 EOC-9 Refueling Outage NRC Inspection Report - 12 Month i
Pursuant to Technical Specification 3/t.4.5.5, part.
b,
.the following-information is submitted:
a.
The following quantity of tubes were inspected from either side of the generator:
Tubes Insoected Steaan Generator Full Lenath A
4190 B
4173 C
4238 D
4212 b.
The following information is submitted concerning tube indications of imperfections. (The attached lists-identify the tubes with imperfections, their locations, and their size.)
Steaut Generator
&t. tag)nnent A
1 B
2 C
3 D
4 c.
The following quantities of tubes were removed from service or repaired:
(The tubes are identified on the attached lists.)
- of. Tubes Attachment A
199 5
B 209 6
C-184 7
D 210 8
Questions or problems should be directed to Kay Crane, Regulatory Complianca at.
(704) 875-4306:
Very truly your,
T. C. McHeekin, Vice President
'McGuire Nuclear Station
_g.
ADOCK c5 coo 379
.if)l 78g82so2929soso2 g
PDR I
anw m =>cwmw
.~
BWNT TUBAN II (Version 2.1) 07/13/1995 13:50:45 McGuire Nuclear Station - Unit Two S/G A, 12 / 94 To ^>
Bobbin,C/L Special Interest,H/L Spec. 1 Interest,H/L Tubesheet,U-Bend Page 1 of 12
)
ATTACHMENT #1 - INDICATIONS OF IMPERFECTIONS INDS OF IMPERFECTIONS - SGA TEST TYPE ROW COL IND %TW VOLTS CHN DEG LOCATION EXTENT 1 Bobbin 2
2 IDI 12 8.87 P 1 139 TE-HL
+10.01 9TH TSP Bobbin 2 60 IDI 55 6.97 P 1 17 TE-HL
+11.29 9TH TSP H/L Special I MAI 1.41 1 14 TTS-HL
-9.93 TTS-HL H/L Tubesheet 2 61 SAI 0.31 1 42 TTS-HL
-1.08 TTS-HL Bobbin 2 66 IDI 44 7.25 P 1 98 TE-HL
+4.96 9TH TSP Bobbin 2 74 IDI 45 12.84 P1 14 TE-HL
+10.18 9TH TSP H/L Special I MAI 0.88 1 34 TTS-HL
-11.22 TTS-HL H/L Special I SAI 6.50 1 17 TTS-HL
-16.44 TTS-HL Bobbin 2 78 ADI 2.91 6 89 19TH TSP
+17 95 9TH TSP C/L Special I VOL 0.72 1 101 19TH TSP
+17.65 16TH TSP Bobbin 3 13 IDI 82 9.72 P 1 67 TE-HL
+4.09 9TH TSP Bobbin 3 16 NQI 0.93 3 114 21ST TSP
+12.45 9TH TSP Bobbin IDI 86 22.99 P 1 61 TE-HL
+15.85 STH TSP C/L Special I VOL 0.81 1 102 21ST TSP
+12.85 21ST TSP Bobbin 3 21 IDI 44 16.11 P 1 16 TE-HL
+1.24 9TH TSP Bobbin 3 22 IDI 24 4.54 P 1 132 TE-HL
+16.70 9TH TSP H/L Tubenheet SAI 3.25 1 44 TTS-HL
-4.12 TTS-HL H/L Special I SAI 4.37 1 19 TTS-HL
-3.90 TTS-HL H/L Tubesheet 3 24 SAI 0.37 1 114 TTS-HL
-0.03 TTS-HL H/L Tubesheet 3 64 SAI 0.63 1 11 TTS-HL
+0.00 TTS-HL H/L Tubesheet 3 73 SAI 1.13 1 46 TTS-HL
-0.01 TTS-HL U-Bend 3 75 VOL 0.51 1 40 BTH TSP
+4.47 9TH TSP Bobbin 3 98 ADI 3.19 6 75 16TH TSP
+18.37 9TH TSP C/L Special I VOL 0.15 1 133 16TH TSP
+18.20 14TH TSP Bobbin 4
16 IDI 79 7.29 P 1 71 TE-HL
+17.90 9TH TSP Bobbin IDI 85 11.80 P 1 63 TE-HL
+14.01 9TH TSP H/L Tubesheet MAI 12.60 1 32 TTS-HL
-3.21 TTS-HL Bobbin 4 48 NQI 0.45 P 1 83 3RD TSP
+0.11 9TH TSP Bobbin NQI 0.63 P 1 62 2ND TSP
+0.03 9TH TSP Bobbin 4 51 IDI 22 3.87 P 1 135 TE-HL
+9.47 9TH TSP Bobbin 4
57 NQI 5.00 P 1 22 TE-HL
+13.97 9TH TSP Bobbin IDI 51 5.09 P 1 18 TE-HL
+16.02 9TH TSP H/L Special I MAI 0.66 1 23 TTS-HL
-4.98 TTS-HL H/L Special I MAI 2.95 1 22 TTS-HL
-7.00 TTS-HL Bobbin 4
58 IDI 90 10.45 P 1 27 TE-HL
+6.70 9TH TSP H/L Tubesheet SAI 2.45 1 21 TTS-HL
+0.09 TTS-HL H/L Tubesheet 4 60 MAI 0.83 1 136 TTS-HL
-4.97 TTS-HL Bobbin 4 62 IDI 60 7.34 P 1 18 TE-HL
+16.70 9TH TSP H/L Tubesheet SAI 2.54 1 35 TTS-HL
-3.91 TTS-HL Bobbin 4 83 IDI 97 24.97 P 1 34 TE-HL
+2.86 9TH TSP H/L Special I MAI 9.80 1 31 TE-HL
+1.94 TTS-HL Bobbin 4
96 NOI 1.95 3 143 3RD TSP
+38.41 9TH TSP H/L Special I VOL 1.11 1 122 4TH TSP
-5.47 4TH TSP Bobbin 4 102 ADI 2.90 6 81 11TH TSP
+39.16 9TH TSP C/L Special I VOL 0.22 1 90 10TH TSP
-4.75 10TH TSP Bobbin 4 105 ODI 5
0.69 3 151 STH TSP
+16.18 9TH TSP Bobbin 4 108 ADI 1.73 6 84 4TH TSP
+10.43 9TH TSP Bobbin ODI 11 1.77 4 160 2ND TSP
+13.99 9TH TSP H/L Special I VOL 0.52 1 130 4TH TSP
+9.98 4TH TSP H/L Special I VOL 0.67 1 113 2ND TSP
+13.21 2ND TSP Bobbin 4 110 ADI 1.98 6 87 10TH TSP
+18.66 9TH TSP C/L Special I VOL 1.01 1 123 10TH TSP
+17.11 10TH TSP Bobbin 5 19 IDI 9
5.93 P 1 148 TE-HL
+11.69 9TH TSP Dobbin 5 23 NOI 0.54 3 101 7TH TSP
+28,72 9TH TSP Bobbin NQI 0.77 3 115 10TH TSP
+10'.83 9TH TSP H/1. Special I VOL 0.95 1 126 8TH TSP
-15.76 8TH TSP C/L Special I VOL 1.26 1 127 10TH TSP
+11.31 10TH TSP Bobbin 5 24 NOI 1.09 3 132 12TH TSP
+20.00 9TH TSP C/L Special I VOL 0.40 1 89 12TH TSP
+20.55 12TH TSP Bobbin 5 46 ADI 3.73 6 92 18TH TSP
+12.44 9TH TSP
'C/L Special I VOL 0.49 1 49 17TH TSP
-10.33 17TH TSP Bobbin 5 59 NQI 0.48 3 85 16TH TSP
+6.70 9TH TSP C/L Special I VOL 0.33 1 118 16TH TSP
+6.71 16TH TSP Bobbin 5 60 IDI 43 5.45 P 1 13 TE-HL
+7.06 9TH TSP H/L Special I MAI 4.62 1 19 TTS-HL
-13.69 TTS-HL
BWNT TUBAN II (Version 2.1) 07/13/1995 13:50:45 McGuire Nuclear Station - Unit Two S/G A 12/94 RFO Bobbin,C/L Special Interest,H/L Special Interest,H/L Tubesheet,U-Bend l
Page 2 of 12
-ATTACHMENT #1 - INDICATIONS OF IMPERFECTIONS INDS OF IMPERFECTIONS - SGA TEST TYPE ROW COL IND %TW VOLTS CHN DEG LOCATION EXTENT 1 Bobbin 5 61 IDI 27 6.21 P 1 8 TE-HL
+18.50 9TH TSP H/L Tubesheet MAI 0.18 1 63 TTS-HL
-1.05 TTS-HL H/L.Tubesheet MAI 0.42 1 39 TTS-HL
-2.89 TTS-HL H/L Special I MAI 0.22 1 52 TTS-HL
-1.06 TTS-HL H/L Special I MAI 0.30 1 36 TTS-HL
-2.93 TTS-HL Bobbin 5 83 NQI 0.45 3 81 TTS-CL
+1.45 9TH TSP Bobbin 5 104 ADI 4.64 6 75 10TH TSP
+5.96 9TH TSP Bobbin 5 107 ODI 17 2.71 4 149 4TH TSP
+21.37 9TH TSP Bobbin ODI 6
1.16 3 137 15TH TSP
+0.91 9TH TSP H/L Special I VOL 1.26 1 112 4TH TSP
+20.51 4TH TSP C/L Special I SAI 0.32 1 60 15TH TSP
+0.93 15TH TSP Bobbin 6
4 ODI 16 2.50 4 133 17TH TSP
+7.85 F/L C/L Special I VOL 0.79 1 104 17TH TSP
+7.71 16TH TSP Bobbin 6 10 ADI 4.85 6 93 12TH TSP
+22.25 F/L-C/L Special I VOL 0.85 1 76 12TH TSP
+22.12 12TH TSP Bobbin 6 12 IDI 19 2.18 P 1 127 TE-HL
+16.53 F/L Bobbin 6 18 IDI 79 6.96 P 1 72 TE-HL
+7.44 F/L Bobbin 6 19 NOI 7.00 P 1 1~1 TE-HL
+9.35 F/L Bobbin IDI 50 2.69 P 1 103 TE-HL
+16.19 F/L H/L Special I SAI 2.67 1 41 TTS-HL
-4.59 TTS-HL H/L Special I SAI 3.33 1 27 TIS-HL
-11.24 TTS-HL Bobbin 6 22 ODI 21 1.14 4 139 3RD TSP
+32.69 F/L H/L Special I VOL 0.76 1 120 4TH TSP
-11.27 4TH TSP Bobbin 6 23 ADI 2.27 6 78 16TH TSP
+6.08 F/L C/L Special I VOL 0.58 1 103 16TH TSP
+6.13 16TH TSP l
Bobbin 6 28 IDI 85 15.45 P 1 63 TE-HL
+11.67 F/L H/L Special I SAI 11.07 1 29 TTS-HL
-9.28 TTS-HL Bobbin 6 40 ODI 12 0.40 3 133 3RD TSP
+24.21 F/L H/L Special I VOL 0.90 1 129 3RD TSP
+25.43 3RD TSP i
Bobbin 6 41 ODI 17 1.09 3 129 STH TSP
+39.02 F/L l
H/L Special I VOL 0.87 1 111 6TH TSP
-4.04 6TH TSP Bobbin 6 42 ODI 25 1.32 4 136 16TH TSP
+8.26 F/L C/L Special I VOL 0.54 1 85 16TH TSP
+8.26 16TH TSP Bobbin 6 44 ADI 2.32 6 85 19TH TSP
+4.90 F/L C/L Special I VOL 0.74 1 107 19TH TSP
+4.83 19TH TSP Bobbin 6 47 ADI 2.79 6 74 7TH TSP
+33.74 F/L Bobbin ODI 32 0.75 3 118 7TH TSP
+3.89 F/L H/L Special I VOL 0.42 1 72 7TH TSP
+33.86 7TH TSP H/L Special I VOL 0.93 1 111 7TH TSP
+3.73 7TH TSP i
Bobbin 6 51 ADI 1.91 6 90 3RD TSP
+33.10 F/L Bobbin ADI 2.01 6 66 14TH TSP
+3.94 F/L H/L Special I VOL 0.45 1 90 4TH TSP
-10.92 4TH TSP C/L Special I VOL 0.41 1 69 14TH TSP
+4.24 13TH TSP Bobbin 6 59 ADI 2.98 6 64 11TH TSP
+28.04 F/L C/L Special I VOL 1.20 1 47 11TH TSP
+26.83 11TH TSP H/L Tubesheet 6 62 SAI 0.50 1 16 TTS-HL
-2.51 TTS-HL Bobbin 6 67 NQI 3.99 3 5 8TH TSP
+12.49 F/L
[
Bobbin 6 79 NQI 0.42 P 1 85 2ND TSP
+0.12 F/L Bobbin 6 81 ADI 5.20 6 91 20TH TSP
+5.39 F/L Bobbin ODI 29 1.30 3 120 18TH TSP
+12.16 F/L C/L Special I VOL 1.16 1 110 18TH TSP
+12.70 18TH TSP C/L Special I VOL 1.36 1 125 20TH TSP
+4.89 18TH TSP Bobbin 6 84 NQI 31.58 P 1 167 TE-HL
+13.47 F/L i
H/L Special I MAI 6.90 1 23 TTS-HL
-7.60 TTS-HL Bobbin 6 95 NOI 42.17 P 1 3 TTS-CL
+0.00 F/L Bobbin 7 12 IDI 98 33.87 P 1 38 TE-HL
+3.01 F/L 1
H/L Tubesheet 7 29 SAI 0.38 1 11 TTS-HL
+0.00 TTS-HL i
Bobbin 7 56 NQI O.63 3 92 STH TSP
+15.36 F/L H/L Special I SAI 0.35 1 97 STH TSP
+15.18 STH TSP Bobbin 7 72 ODI 12 0.94 3 136 STH TSP
+38.33 F/L H/L Special I VOL 2.20 1 151 6TH TSP
-5.64 6TH TSP Bobbin 7 99 ODI 2
1.42 4 143 6TH TSP
+27.30 F/L Bobbin ODI 24 0.94 4 126 13TH TSP
+10.54 F/L Bobbin ODI 29 1.40 4 121 11TH TSP
+7.71 F/L H/L Special I VOL 0.87 1 115 7TH TSP
-16.42 7TH TSP
B"NT TUBAN II (Version 2.1) 07/13/1995 13:50:45 McGuire Nuclear Station - Unit Two e*******
S/G A 12/94 RFO Bobbin,C/L Special Int 9 rest,H/L Special Interest,H/L Tubesheet,U-Bend Page 3 of 12 ATTACHMENT #1 - INDICATIONS OF IMPERFECTIONS INDS OF IMPERFECTIONS - SGA TEST TYPE ROW COL IND %TW VOLTS CHN DEG LOCATION EXTENT 1 C/L Special I VOL 0.74 1 107 13TH TSP
+9.55 13TH TSP C/L Special I VOL 0.88 1 104 11TH TSP
+7.02 11TH TSP Bobbin 7 108 ADI 3.86 6 69 10TH TSP
+6.80 F/L C/L Special I VOL 0.98 1 126 10TH TSP
+6.48 10TH TSP H/L Tubesheet 8 16 SAI 1.23 1 22 TTS-HL
+0.03 TTS-HL Bobbin 8 20 NQI 0.60 3 60 18TH TSP
+3.17 F/L C/L Special I VOL 0.60 1 137 18TH TSP
+3.15 18TH TSP Bobbin 8 55 IDI 55 14.20 P 1 17 TE-HL
+11.26 F/L Bobbin 8 59 NQI 0.20 3 90 13TH TSP
+19.79 F/L Bobbin IDI 89 40.39 P 1 52 TE-HL
+5.49 F/L H/L Special I MAI 12.94 1 30 TE-HL
+4.88 TTS-HL Bobbin 8 93 ODI 6
0.52 3 138 10TH TSP
+37.82 F/L C/L Special I VOL 1.10 1 147 9TH TSP
-5.66 9TH TSP Bobbin 9 15 ADI 2.73 6 48 11TH TSP
+5.32 F/L C/L Special I VOL 0.25 1 127 11TH TSP
+5.06 11TH TSP H/L Tubesheet 9 28 SAI 0.34 1 82 TTS-HL 40.10 TTS-HL Bobbin 9 38 ODI 27 0.82 3 123 18TH TSP
+20.35 F/L Bobbin IDI 39 12.43 P 1 12 TE-HL
+13.56 F/L C/L Special I VOL 1.20 1 87 17TH TSP
-1.78 17TH TSP Bobbin 9 43 NOI 1.18 3 136 STH TSP
+5.57 F/L Bobbin ODI 7
0.87 3 137 6TH TSP
+5.50 F/L Bobbin ODI 14 1.32 3 132 6TH TSP
+18.16 F/L Bobbin ODI 21 0.78 3 127 STH TSP
+32.13 F/L Bobbin ODI 19 1.16 3 129 12TH TSP
+2.27 F/L H/L Special I VOL 0.61 1 139 6TH TSP
+5.11 6TH TSP H/L Special I VOL 0.79 1 107 61H TSP
+17.54 6TH TSP
. H/L Special I VOL 1.06 1 116 6TH TSP
-11.68 6TH TSP H/L Special I VOL 1.55 1 142 STH TSP
+5.17 5TH TSP C/L Special I VOL 1.29 1 77 12TH TSP
+2.41 12TH TSP Bobbin 9 69 ADI 5.12 6 72 6TH TSP
+7.64 F/L Bobbin ODI 10 1.21 3 132 STH TSP
+27.32 F/L H/L Special I VOL 0.48 1 127 6TH TSP
-16.67 6TH TSP H/L Special I VOL 0.90 1 70 6TH TSP
+7.33 6TH TSP Bobbin 9 70 NOI 0.50 3 112 7TH TSP
+29.51 F/L H/L Special I VOL 0.54 1 157 7TH TSP
+28.87 7TH TSP Bobbin 9 73 ADI 5.50 6 80 STH TSP
+30.58 F/L Bobbin NQI 1.11 3 116 7TH TSP
+11.94 F/L H/L Special I VOL 2.11 1 86 6TH TSP
-12.77 6TH TSP H/L Special I VOL 2.55 1 122 7TH TSP
+11.65 7TH TSP Bobbin 9 74 ADI 3.33 6 90 10TH TSP
+36.13 F/L Bobbin ADI 7.16 6 87 16TH TSP
+7.11 F/L C/L Special I VOL 0.62 1 90 9TH TSP
-8.07 9TH TSP C/L Special I VOL 0.89 1 95 16TH TSP
+6.32 14TH TSP Bobbin 9 75 ODI 32 1.20 3 116 18TH TSP
+3.85 F/L C/L Special I SAI 1.40 1 12 18TH TSP
+3.63 18TH TSP Bobbin 9 82 NOI 0.78 3 98 7TH TSP
+21.27 F/L H/L Special I VOL 1.94 1 131 7TH TSP
+20.61 7TH TSP Bobbin 9 86 ADI 2.84 6 76 7TH TSP
+19.45 F/L H/L Special I VOL 0.41 1 137 7TH TSP
+19.34 BTH TSP Bobbin 9 95 ADI 3.04 6 80 18TH TSP
+5.92 F/L C/L Special I VOL 0.36 1 106 18TH TSP
+5.26 18TH TSP Bobbin 9 105 IDI 92 13.42 P 1 47 TE-HL
+7.32 F/L Bobbin 10 58 ADI 2.34 6 62 3RD TSP
+13.39 F/L H/L Special I VOL 0.47 1 150 3RD TSP
+13.52 3RD TSP Bobbin 10 59 NQI 0.52 P 1 73 2ND TSP
-0.10 F/L H/L Special I 10 75 VOL 2.08 1 95 STH TSP
-1.92 STH TSP Bobbin 10 95 ODI 16 0.48 3 128 4TH TSP
+26.02 F/L H/L Special I VOL 0.62 1 130 STH TSP
-17.21 STH TSP Bobbin 10 96 ADI 4.23 6 63 6TH TSP
+30.28 F/L H/L Special I VOL 0.43 1 117 7TH TSP
-5.76 7TH TSP Bobbin 10 99 ODI 3
0.31 P 1 135 3RD TSP
+0.12 F/L Bobbin 10 103 NQI 2.09 P 1 149 TE-HL
+10.56 F/L Bobbin 10 104 ODI 14 0.95 3 130 11TH TSP
+7.51 F/L C/L Special I VOL 1.39 1 92 11TH TSP
+6.82 11TH TSP Bobbin 10 112 ODI 10 5.28 4 148 4TH TSP
+7.09 F/L
BWNT TUBAN II (Varsion 2.1) 07/13/1995 13:50:45 e****e**
McGuire Nuclear Station - U it Two n
ee******
S/G A 12/94 RFO Bobbin,C/L Special Interest,H/L Special Interest,H/L Tubesheet,U-Bend Page 4 of 12 ATTACHMENT #1 - INDICATIONS OF IMPERFECTIONS INDS OF IMPERFECTIONS - SGA TEST TYPE ROW COL IND %TW VOLTS CHN DEG LOCATION EXTENT 1 H/L Special I VOL 1.02 1 57 4TH TSP
+7.42 4TH TSP Bobbin 11 4 IDI 58 11.43 P 1 19 TE-HL
+8.60 F/L Bobbin 11 11 NOI 0.32 3 75 2ND TSP
+13.60 F/L Bobbin 11 59 IDI 13 3.46 P 1 129 TE-HL
+17.02 F/L Bobbin 11 65 ODI 20 1.60 4 138 10TH TSP
+41.07 F/L C/L Special I VOL 0.76 1 117 9TH TSP
-3.03 9TH TSP i
Bobbin 11 66 ODI 33 1.05 4 128 10TH TSP
+5.63 F/L Bobbin 11 67 ODI 25 0.55 3 121 17TH TSP
+4.53 F/L H/L Special I VOL 0.75 1 89 BTH TSP
+0.74 8TH TSP C/L Special I VOL 0.89 1 41 17TH TSP
-2.14 17TH TSP Bobbin 11 72 NQI 4.86 P 1 142 TE-HL
+10.39 F/L Bobbin NQI 7.37 P 1 124 TE-HL
+13.24 F/L i
Bobbin 11 84 ADI 3.30 6 55 19TH TSP
-1.23 F/L Bobbin ODI 10 3.18 4 137 10TH TSP
+38.92 F/L C/L Special I VOL 1.42 1 128 9TH TSP
-5.24 9TH TSP C/L Special I VOL 0.76 1 85 19TH TSP
-1.49 19TH TSP Bobbin 11 97 ADI 2.60 6 89 11TH TSP
+27.52 F/L C/L Special I VOL 0.49 1 65 11TH TSP
+27.33 11TH TSP Bobbin 11 99 ODI 18 2.53 4 133 6TH TSP
+17.18 F/L i
H/L Special I VOL 1.43 1 109 6TH TSP
+16.87 6TH TSP
' Bobbin 12 13 IDI 58 12.15 P 1 19 TE-HL
+4.86 F/L
]
Bobbin 12 27 NQ1 0.30 3 108 7TH TSP
+3.32 F/L Bobbin 12 35 IDI 64 28.81 P 1 21 TE-HL
+4.48 F/L Bobbin 12 36 IDI 67 10.76 P 1 22 TE-HL
+13.37 F/L Bobbin 12 62 IDI 86 15.07 P 1 24 TE-HL
+11.44 F/L Bobbin 12 73 NOI 14.58 P 1 29 TE-HL
+12.42 F/L Bobbin 13 13 IDI 91 10.72 P 1 51 TE-HL
+15.00 F/L Bobbin 13 25 IDI 55 9.90 P 1 17 TE-HL
+15.77 F/L Bobbin 13 56 NQI 0.22 P 1 54 STH TSP
-0.02 F/L H/L Special I SAI 0.29 1 138 STH TSP
-0.06 STH TSP H/L Tubesheet 13 110 SAI 0.77 1 111 TTS-HL
-3.47 TTS-HL Bobbin 14 19 IDI 74 5.30 P 1 23 TE-HL
+17.27 F/L H/L Special I MAI 1.00 1 50 TTS-HL
-3.10 TTS-HL Bobbin 14 24 IDI 54 10.90 P 1 19 TE-HL
+3.57 F/L Bobbin 14 59 IDI 48 9.14 P 1 15 TE-HL
+12.26 F/L Bobbin 14 67 ADI 6.78 6 92 13TH TSP
+5.80 F/L C/L Special I VOL 0.69 1 88 13TH TSP
+5.11 13TH TSP Bobbin 14 73 IDI 95 40.38 P 1 40 TE-HL
+17.50 F/L i
H/L Tubesheet MAI 7.30 1 22 TTS-HL
-4.35 TTS-HL H/L Special I MAI 7.42 1 34 TTS-HL
Bobbin 14 87 ADI 2.77 6 84 6TH TSP
+38.92 F/L Bobbin ODI 1
0.75 3 141 6TH TSP
+37.55 F/L Bobbin ODI 2
1.97 3 140 7TH TSP
+14.82 F/L H/L Special I VOL 1.79 1 124 7TH TSP
+14.87 7TH TSP Bobbin 14 88 ADI 2.95 6 76 10TH TSP
+5.91 F/L Bobbin 14 94 ADI 3.19 6 84 13TH TSP
+5.71 F/L Bobbin 14 112 NOI 1.22 3 105 11TH TSP
+13.69 F/L C/L Special I VOL 2.06 1 101 11TH TSP
+13.60 11TH TSP Bobbin 15 27 ODI 29 0.35 3 121 10TH TSP
+10.46 F/L C/L Special I VOL 0.61 1 71 10TH TSP
+10.62 10TH TSP Bobbin 15 40 ODI 17 0.89 4 139 10TH TSP
+19.40 F/L C/L Special I VOL 0.98 1 78 10TH TSP
+19.21 10TH TSP Bobbin 15 45 IDI 83 19.51 P 1 29 TE-HL
+17.18 F/L H/L Tubesheet MAI 6.82 1 38 TTS-HL
-4.64 TTS-HL
' Bobbin 15 50 IDI 66 12.63 P 1 23 TE-HL
+10.61 F/L Bobbin 15 67 IDI 94 35.37 P 1 35 TE-HL
+10.23 F/L H/L Tubesheet 15 71 SAI 0.36 1 38 TTS-HL
-1.43 TTS-HL Bobbin 15 72 ADI 4.22 6 75 11TH TSP
+38.27 F/L Bobbin IDI 61 20.55 P 1 20 TE-HL
+7.90 F/L C/L Special I VOL 0.95 1 99 10TH TSP
-5.96 10TH TSP Bobbin 15 78 ODI 5
0.98 3 137 STH TSP
+32.29 F/L Bobbin 15 91 NQI 0.74 3 84 7TH TSP
+22.19 F/L H/L Special I NQI 0.53 1 13 7TH TSP
+22.46 7TH TSP Bobbin 15 105 IDI 64 11.36 P 1 21 TE-HL
+6.98 F/L H/L Special I MAI 1,59 1 10 TE-HL
+7.05 TE-HL
j BWNT TUBAN II (Version 2.1) 07/13/1995 13:50:45 McGuire Nuclear Station - Unit Two S/G A 12/94 RFO I
Bobbin,C/L Special Interest,H/L Special Interest,H/L Tubesheet,U-Bend ATTACHMENT #1 - INDICATIONS OF IMPERFECTIONS INDS OF IMPERFECTIONS - SGA TEST TYPE ROW COL IND %TW VOLTS CHN DEG LOCATION EXTENT 1 Bobbin 16 9 IDI 54 13.44 P 1 19 TE-HL
+13.42 F/L i
H/L Special I MAI 1.53 1 21 TTS-HL
-6.89 TTS-HL Bobbin 16 11 IDI 40 11.33 P 1 14 TE-HL
+11.47 F/L Bobbin 16 22 NQI 1.10 3 134 2ND TSP
+17.07 F/L H/L Special I VOL 1.26 1 118 3RD TSP
-7.02 3RD TSP Bobbin 16 29 IDI 63 14.48 P 1 22 TE-HL
+13.40 F/L H/L Special I MAI 0.68 1 25 TTS-HL
-7.23 TTS-HL H/L Tubesheet 16 42 MAI 0.97 1 30 TTS-HL
-0.03 TTS-HL Bobbin 16 51 ODI 5
0.43 3 138 6TH TSP
+30.28 F/L H/L Special I VOL 0.31 1 96 7TH TSP
-6.38 7TH TSP H/L Tubesheet 17 14 SAI 1.43 1 24 TTS-HL
+0.18 TTS-HL Bobbin 17 24 IDI 57 22.52 P 1 16 TE-HL
+10.56 F/L Bobbin IDI 96 25.64 P 1 27 TE-HL
+14.38 F/L Bobbin 17 25 IDI 79 19.71 P 1 22 TE-HL
+14.36 F/L Bobbin 17 31 IDI 43 19.70 P 1 12 TE-HL
+9.66 F/L Bobbin IDI 46 14.53 P 1 13 TE-HL
+16.35 F/L Bobbin 17 48 IDI 83 8.65 P 1 62 TE-HL
+16.68 F/L H/L Tubesheet MAI 5.21 1 34 TTS-HL
-4.97 TTS-HL H/L Tubenheet 17 62 SAI 0.40 1 127 TTS-HL
+0.70 TTS-HL Bobbin 17 65 ADI 1.91 6 71 STH TSP
+27.97 F/L H/L Special I VOL 0.87 1 134 6TH TSP
-3.09 6TH TSP H/L Special I VOL 1.30 1 157 6TH TSP
-15.26 6TH TSP Bobbin 17 72 IDI 65 19.70 P 1 20 TE-HL
+9.34 F/L H/L Special I MAI 4.13 1 15 TTS-HL
-11.97 TTS-HL Bobbin 18 5 ADI 4.52 6 73 12TH TSP
+12.63 F/L C/L Special I VOL 0.47 1 98 12TH TSP
+12.86 12TH TSP Bobbin 18 15 IDI 57 15.08 P 1 16 TE-HL
+5.64 F/L H/L Tubesheet 18 25 SAI 0.29 1 104 TTS-HL
+0.08 TTS-HL Bobbin 18 98 ODI 17 0.44 3 129 3RD TSP
+29.19 F/L H/L Special I VOL 0.42 1 111 4TH TSP
-21.56 4TH TSP Bobbin 18 104 NQI 7.34 P 1 138 TE-HL
+13.13 F/L H/L Tubesheet SAI 2.73 1 28 TTS-HL
-3.75 TTS-HL H/L Special I MAI 7.46 1 31 TTS-HL
-7.95 TTS-HL H/L Special T SAI 3.46 1 18 TTS-HL
-3.02 TTS-HL Bobbin 19 21 IDI 53 15.64 P 1 17 TE-HL
+8.38 F/L Bobbin 19 22 IDI 53 14.00 P 1 17 TE-HL
+4.79 F/L H/L Tubesheet 19 28 SAI 2.40 1 19 TTS-HL
+0.15 TTS-HL Bobbin 19 29 IDI 38 13.90 P 1 12 TE-HL
+13.37 F/L Bobbin -
IDI 47 17.77 P 1 15 TE-HL
+14.41 F/L H/L Special I MAI 0.18 1 30 TTS-HL
-6.28 TTS-HL H/L Special I SAI 2.62 1 23 TTS-HL
-7.31 TTS-HL Bobbin 19 34 ADI 3.65 6 50 4TH TSP
+16.24 F/L Bobbin 19 37 ADI 4.99 6 74 20TH TSP
+5.78 F/L C/L Special I VOL 0.73 1 90 19TH TSP
-2.49 19TH TSP Bobbin 19 56 NQI 1.05 3 123 11TH TSP
+17.68 F/L C/L Special I VOL 1.11 1 92 11TH TSP
+17.00 11TH TSP Bobbin 19 59 NQI 6.86 P 1 142 TE-HL
+15.99 F/L H/L Special I SAI 5.56 1 27 TTS-HL
-5.12 TTS-HL Bobbin 19 61 ODI 28 0.51 3 121 4TH TSP
+4.87 F/L H/L Special I VOL 0.96 1 127 4TH TSP
-1.39 4TH TSP H/L Special I VOL 0.97 1 152 4TH TSP
+4.76 4TH TSP H/L Special I VOL 1.19 1 138 4TH TSP
+2.68 4TH TSP H/L Special I VOL 1.27 1 155 4TH TSP
+0.76 4TH TSP Bobbin 19 68 ODI 29 0.32 3 120 6TH TSP
+25.97 F/L H/L Special I VOL 0.38 1 49 7TH TSP
-18.35 7TH TSP Bobbin 19 73 NOI 2.57 P 1 54 TE-HL
+19.79 F/L Bobbin NQI 14.63 P 1 24 TE-HL
+9.86 F/L H/L Tubesheet MAI 1.85 1 33 TTS-HL
-1.51 TTS-HL H/L Special I MAI 1.68 1 37 TTS-HL
-1.25 TTS-HL H/L Special I SAI 1.82 1 39 TTS-HL
-15.91 TTS-HL r
H/L Special I SAI 2.52 1 30 TTS-HL
-12.75 TTS-HL Bobbin 19 96 WAR 13 0.56 P 4 0 1AVB
+0.00 F/L Bobbin 20 16 ADI 2.60 6 67 11TH TSP
+34.30 F/L C/L Special I VrL 0.65 1 72 10TH TSP
+2.65 10TH TSP Bobbin 20 17 iDI e.t8 6 64 11TH TSP
+23.52 F/L
1 BWNT TUBAN II (Version 2.1) 07/13/1995 13:50:45 j
McGuire Nuclear Station - Unit Two eeeee***
s/g A 12/94 RFO Bobbin,C/L Special Interest,H/L Special Interest,H/L Tubesheet,U-Bend Page 6 of 12 ATTACHMENT #1 - INDICATIONS OF IMPERFECTIONS INDS OF IMPERFECTIONS - SGA TEST TYPE ROW COL IND %TW VOLTS CHN DEG LOCATION EXTENT 1 C/L Special I VOL 0.51 1 89 10TH TSP
-21.21 10TH TSP Bobbin 20 20 ADI 3.32 6 75 7TH TSP
+41.73 F/L H/L Special I VOL 0.49 1 118 7TH TSP
+42.18 7TH TSP Bobbin 20 28 IDI 67 8.37 P 1 85 TE-HL
+14.43 F/L H/L Special I MAI 1.95 1 22 TTS-HL
-6.09 TTS-HL Bobbin 20 30 ADI 5.17 6 79 6TH TSP
+12.66 F/L H/L Special I VOL 1.22 1 128 6TH TSP
+12.97 6TH TSP Bobbin 20 36 NQI 0.65 3 64 TTS-CL
+1.11 F/L Bobbin 20 49 ADI 3.63 6 59 11TH TSP
+29.65 F/L Bobbin 20 55 NQI 0.61 3 112 4TH TSP
+33.99 F/L H/L Special I VOL 1.15 1 104 STH TSP
-10.06 STH TSP Bobbin 20 66 ADI 3.75 6 78 12TH TSP
+17.83 F/L C/L Special I VOL 1.51 1 104 12TH TSP
+16.16 12TH TSP Bobbin 20 70 ODI 32 2.04 4 131 3RD TSP
+17.75 F/L H/L Tubesheet VOL 1.76 1 143 TTS-HL
+1.25 TTS-HL H/L Special I VOL 0.84 1 94 3RD TSP
+17.42 3RD TSP Bobbin 20 73 IDI 64 21.88 P 1 21 TE-HL
+10.28 F/L H/L Special I MAI 1.55 1 18 TTS-HL
-12.84 TTS-HL H/L Special I MAI 2.85 1 25 TTS-HL
-10.73 TTS-HL H/L Special I SAI 0.88 1 10 TTS-HL
-14.87 TTS-HL Bobbin 20 87 IDI 94 1.79 P 1 46 TE-HL
+12.83 F/L Bobbin 21 24 ADI 3.40 6 83 STH TSP
+36.01 F/L H/L Special I VOL 0.94 1 109 6TH TSP
-7.47 6TH TSP Bobbin 21 26 ADI 4.20 6 88 10TH TSP
+40.85 F/L Bobbin ODI 16 1.65 4 142 18TH TSP
+10.05 F/L C/L Special I VOL 0.39 1 109 9TH TSP
-3.56 9TH TSP Bobbin 21 34 ADI 2.57 6 87 11TH TSP
+11.75 F/L Bobbin ODI 20 0.87 4 140 11TH TSP
+16.34 F/L C/L Special I VOL 0.57 1 58 11TH TSP
+11.94 11TH TSP C/L Special I VOL 0.58 1 62 11TH TSP
+14.73 11TH TSP Bobbin 21 35 ODI 22 2.23 4 139 12TH TSP
+9.83 F/L C/L Special I VOL 0.90 1 118 12TH TSP
+9.18 12TH TSP H/L Tubesheet 21 49 SCI 0.69 1 14 TTS-HL
+0.00 TTS-HL Bobbin 21 58 IDI 54 9.77 P 1 97 TE-HL
+6.96 F/L Bobbin IDI 94 16.23 P 1 44 TE-HL
+7.61 F/L f
H/L Special I MAI 9.95 1 24 TE-HL
+7.08 TTS-HL H/L Special I SAI 7.70 1 41 TE-HL
+7.39 TTS-HL Bobbin 21 81 NOI 0.60 P 1 114 3RD TSP
+0.04 F/L H/L Tubesheet 21 98 SAI 3.05 1 22 TTS-HL
-2.91 TTS-HL Bobbin 21 100 IDI 30 5.65 P 1 10 TE-HL
+14.13 F/L Bobbin 22 9 ADI 1.86 6 74 IST TSP
+14.53 F/L Bobbin ADI 5.01 6 53 7TH TSP
+18.98 F/L H/L Special I VOL 0.66 1 82 2ND TSP
-5.74 2ND TSP H/L Special I VOL 1.19 1 116 7TH TSP
+10.41 7TH TSP H/L Special I VOL 1.28 1 109 7TH TSP
+18.47 7TH TSP Bobbin 22 23 NOI 6.45 P 1 158 TE-HL
+16.06 F/L Bobbin 22 35 ADI 3.14 6 81 4TH TSP
+37.49 F/L Bobbin 22 44 NQI 0.42 P 1 75 18TH TSP
+0.35 F/L Bobbin WAR 22 1.17 P 4 0 2AVB
+0.00 F/L Bobbin 22 55 IDI 87 21.72 P 1 56 TE-HL
+15.19 F/L Bobbin 22 67 ADI 3.64 6 89 18TH TSP
+5.44 F/L C/L Special I VOL 1.05 1 124 18TH TSP
+5.31 18TH TSP Bobbin 22 85 ADI 1.73 6 43 3AVB
+11.98 F/L Bobbin 22 86 WAR 19 1.01 P 4 0 2AVB
+0.00 F/L Bobbin 22 92 NQI 1.08 3 38 21ST TSP
+3.64 F/L Bobbin 23 7 IDI 15 8.39 P 1 126 TE-HL
+6.21 F/L Bobbin 23 13 WAR 14 0.60 P 4 0 4AVB
+0.00 F/L Bobbin 23 24 IDI 86 22.46 P 1 58 TE-HL
+16.87 F/L H/L Tubesheet MAI 6.11 1 39 TTS-HL
-4.96 TTS-HL Bobbin 23 29 IDI 53 10.94 P1 99 TE-HL
+7.33 F/L H/L Special I MAI 9.86 1 37 TE-HL
+6.88 TTS-HL Bobbin 23 42 ADI 5.66 6 90 4AVB
-14.11 F/L U-Bend VOL 0.92 1 50 4AVB
-14.00 9TH TSP U-Bend VOL 1.06 1 62 9TH TSP
+7.44 9TH TSP H/L Tubesheet 23 69 SCI 1.16 1 36 TTS-HL
-0.05 TTS-HL
BWNT TUBAN II (Version 2.1) 07/13/1995 13:50:45 McGuire Nuclear Station - Unit Two S/G A 12/94 RFO Bobbin,C/L Special Interest,H/L Special Interest,H/L Tubesheet,U-Bend i
Page 7 of 12 ATTACHMENT #1 - INDICATIONS OF IMPERFECTIONS
- INDS OF IMPERFECTIONS - SGA TEST TYPE ROW COL IND %TW VOLTS CHN DEG LOCATION EXTENT 1 Bobbin 23 70 NOI 1.66 3 140 3RD TSP
+4.46 F/L H/L Special I VOL 1.83 1 139 3RD TSP
+4.66 3RD TSP Bobbin 23 83 ADI 5.29 6 89 TTS-HL
+6.03 F/L Bobbin ODI 27 2.14 4 133 STH TSP
+19.34 F/L H/L Special I VOL 1.52 1 162 TTS-HL
+6.00 1ST TSP H/L Special I VOL 0.21 1 77 STH TSP
+5.82 STH TSP i
H/L Special I VOL 1.92 1 146 STH TSP
+19.04 STH TSP Bobbin 24 14 IDI 56 8.73 P 1 97 TE-HL
+13.14 F/L Bobbin 24 22 IDI 56 7.88 P 1 97 TE-HL
+14.97 F/L H/L Special I SAI 9.10 1 20 TTS-HL
-5.88 TTS-HL Bobbin 24 25 IDI 27 10.63 P 1 119 TE-HL
+16.85 F/L H/L Tubesheet SAI 7.96 1 19 TTS-HL
-4.25 TTS-HL Bobbin 24 36 IDI 77 15.80 P 1 73 TE-HL
+15.91 F/L H/L Tubesheet 24 49 SAI 0.79 1 50 TTS-HL
-4.17 TTS-HL Bobbin 24 53 ADI 0.48 6 59 TTS-CL
+1.61 F/L Bobbin 24 73 NQI 0.73 3 142 3RD TSP
+16.94 F/L H/L Special I VOL 0.62 1 129 3RD TSP
+17.54 3RD TSP H/L Special I VOL 1.00 1 172 3RD TSP
+15.95 3RD TSP Bobbin 24 93 WAR 20 1.05 P 4 0 1AVB
+0.00 F/L Bobbin 25 8 NOI 0.43 3 98 7TH TSP
+12.12 F/L H/L Special I VOL 0.35 1 114 7TH TSP
+13.40 7TH TSP Bobbin 25 13 IDI 71 9.74 P1 81 TE-HL
+2.80 F/L Bobbin 25 17 ODI 28 0.99 3 119 STH TSP
+5.15 F/L H/L Special I VOL 0.82 1 113 STH TSP
+5.35 5TH TSP H/L Tubesheet 25 29 SAI 2.48 1 19 TTS-HL
-4.22 TTS-HL O.54 3 109 12TH TSP
+31.20 F/L Bobbin 25 3 0 NO',
+31.20 11TH TSP C/L Special I Bobbin 25 38 OD1 6
2.20 4 144 3RD TSP
+20.09 F/L H/L Special I VOL 0.49 1 118 3RD TSP
+20.53 3RD TSP Bobbin 25 43 NQI 6.57 3 11 15TH TSP
-0.97 F/L Bobbin 25 55 IDI 20 6.27 P 1 123 TE-HL
+9.42 F/L Bobbin 25 63 NOI 6.57 P 1 155 TE-HL
+7.69 F/L H/L Special I SAI 5.30 1 17 TTS-HL
-13.79 TTS-HL Bobbin 25 73 ODI 17 0.37 3 129 3RD TSP
+39.84 F/L H/L Special I VOL 0.84 1 150 4TH TSP
-4.97 4TH TSP H/L Special I VOL 0.88 1 148 4TH TSP
-3.33 4TH TSP Bobbin 25 74 ODI 11 0.83 3 133 22ND TSP
+11.10 F/L C/L Special I VOL 1.08 1 147 22ND TSP
+10.78
-22ND TSP Bobbin 26 12 NOI 7.37 P 1 166 TE-HL
+16.17 F/L 4
H/L Tubesheet SAI 4.95 1 20 TTS-HL
-5.81 TTS-HL Bobbin 26 22 ODI 30 0.69 3 118 11TH TSP
+14.18 F/L C/L Special I VOL 0.20 1 111 11TH TSP
+14.71 11TH TSP H/L Tubesheet 26 33 SCI 1.83 1 15 TTS-HL
-0.06 TTS-HL j
Bobbin 26 45 IDI 32 22.75 P 1 10 TE-HL
+16.30 F/L H/L Tubesheet MAI 2.32 1 23 TTS-HL
-5.20 TTS-HL Bobbin 26 61 ODI 12 0.69 3 132 15TH TSP
+7.46 F/L C/L Special I VOL 0.87 1 136 15TH TSP
+7.04 14TH TSP Bobbin 26 62 ADI 2.28 6 75 10TH TSP
+28,14 F/L Bobbin 26 67 WAR 17 0.78 P 4 0 2AVB
+0.00 F/L i
Bobbin 26 69 ODI 11 1.60 3 133 7TH TSP
+20.32 F/L I
H/L Special I VOL 1.09 1 107 7TH TSP
+20.20 7TH TSP
]
Bobbin 26 74 ADI 4.05 6 81 10TH TSP
+29.04 F/L C/L Special I VOL 0.90 1 31 10TH TSP
+27.63 10TH TSP l
Bobbin 26 83 ADI 4.38 6 81 10TH TSP
+27.53 F/L Bobbin WAR 17 0.79 P 4 0 4AVB
+0.00 F/L i
Bobbin WAR 21 1.04 P 4 0 3AVB
+0.00 F/L Bobbin 26 84 WAR 19 0.89 P 4 0 1AVB
+0.00 F/L Bobbin 26 103 WAR 12 0.55 P 4 0 1AVB
+0.00 F/L Bobbin 26 106 WAR 18 0.84 P 4 0 1AVB
+0.00 F/L H/L Tubesheet 27 18 SAI 0.25 1 54 TTS-HL
+0.00 TTS-HL Bobbin 27 28 IDI 71 4.69 P 1 82 TE-HL
+9.32 F/L H/L Tubesheet 27 37 SAI 1.25 1 23 TTS-HL
+0.00 TTS-HL Bobbin 27 39 IDI 78 23.17 P 1 28 TE-HL
+1.71 F/L Bobbin 27 44 WAR 22 1.13 P 4 0 2AVB
+0.00 F/L Bobbin 27 51 WAR 31 2.05 P 4 0 2AVB
+0.00 F/L i
r l
BWNT TUBAN II (Varsion 2.1) 07/13/1995 13:50:45 McGuira Nuclear Station - Unit Two
- cc*****-
S/G A 12/94 RFO Bobbin,C/L Special Interest,H/L Special Interest,H/L Tubesheet,U-Bend r
Page 8 of 12
. ATTACHMENT #1 - INDICATIONS OF IMPERFECTIONS INDS OF IMPERFECTIONS - SGA TEST TYPE ROW COL IND %TW VOLTS CHN DEG LOCATION EXTENT 1 H/L Tubesheet SCI 0.61 1 138 TTS-HL
-0.04 TTS-HL Bobbin 27 52 IDI 68 10.13 P 1 85 TE-HL
+5.48 F/L H/L Tubesheet 27 57 SAI 1.12 1 30 TTS-HL
+0.03 TTS-HL Bobbin 27 58 IDI 95 30.85 P 1 46 TE-HL
+1.35 F/L H/L Special I MAI 11.00 1 31 TE-HL
+0.65 TTS-HL Bobbin 27 61 IDI 64 6.01 P 1 92 TE-HL
+9.18 F/L Bobbin IDI 67 6.18 P 1 89 TE-HL
+5.33 F/L Bobbin IDI 79 24.67 P 1 74 TE-HL
+8.24 F/L H/L Special I MAI 3.98 1 19 TTS-HL
-12.92 TTS-HL H/L Special I MAI 4.62 1 23 TTS-HL
-13.74 TTS-HL H/L Special I SAI 1.92 1 21 TTS-HL
-12.30 TTS-HL H/L Special I SAI 7.04 1 25 TTS-HL
-16.32 TTS-HL H/L Tubesheet 27 76 VOL 0.49 1 123 TTS-HL
-1.26 TTS-HL Bobbin 27 79 ODI 1
1.72 3 139 STH TSP
+5.54 F/L H/L Special I VOL 1.14 1 91 STH TSP
+5.41 STH TSP Bobbin 27 87 ADI 2.21 6 82 STH TSP
+32.25 F/L H/L Special I VOL 0.51 1 135 6TH TSP
-11.5S 6TH TSP Bobbin 27 99 WAR 24 1.28 P 4 0 1AVB
+0.00 F/L-Bobbin 27 103 WAR 18 0.83 P 4 0 1AVB
+0.00 F/L Bobbin 27 106 WAR 33 2.36 P 4 0 1AVB
+0.00 F/L Bobbin 28 13 IDI 42 9.74 P 1 105 TE-HL
+10.42
.F/L Bobbin 28 31 NQI 7.46 P 1 161 TE-HL
+3.63 F/L Bobbin 28 47 ADI 3.58 6 59 15TH TSP
+7.12 F/L C/L Special I VOL 1.40 1 128 14TH TSP
-4.34 14TH TSP Bobbin 28 48 WAR 16 0.71 P 4 0 1AVB
+0.00 F/L Bobbin 28 56 WAR 18 0.82 P 4 0 1AVB
+0.00 F/L Bobbin 28 82 ODI 28 0.83 3 121 4TH TSP
+11.18 F/L H/L Special I VOL 1.31 1 124 4TH TSP
+10.93 4TH TSP Bobbin 28 101 WAR 16 0.84 P 4 0 1AVB
+0.00 F/L Bobbin 28 103 ODI 2
2.13 4 149 11TH TSP
+14.10 F/L Bobbin WAR 15 0.76 P 4 0 1AVB
+0.00 F/L C/L Special I VOL 0.68 1 119 11TH TSP
+13.87 11TH TSP Bobbin 29 25 IDI 35 14.11 P 1 12 TE-HL
+15.16 F/L H/L Special I MAI 2.84 1 16 TTS-HL
-6.04 TTS-HL Bobbin 29 38 IDI 18 1.75 P 1 124 TE-HL
+12.74 F/L Bobbin 29 51 WAR 23 1.23 P 4 0 1AVB
+0.00 F/L Bobbin 29 53 ADI 3.61 6 87 11TH TSP
+25.65 F/L Bobbin ODI 9
0.70 3 133 11TH TSP
+35.88 F/L C/L Special I VOL 0.22 1 112 10TH TSP
-7.95 10TH TSP C/L Special I VOL 0.64 1 100 10TH TSP
-18.05 10TH TSP Bobbin 29 57 WAR 17 0.78 P 4 0 1AVB
+0.00 F/L Bobbin 29 76 ADI 2.51 6 106 2AVB
+8.90 F/L Bobbin 29 77 ADI 3.00 6 95 STH TSP
+11.88 F/L H/L Special I VOL 0.96 1 103 STH TSP
+12.23 STH TSP Bobbin 29 91 ODI 16 2.05 3 130 6TH TSP
+36.32 F/L H/L Special I VOL 2.04 1 112 7TH TSP
-7.70 7TH TSP Bobbin 29 92 WAR 24 1.21 P 4 0 1AVB
+0.00 F/L Bobbin 29 95 ADI 4.73 6 53 1AVB
+11.07 F/L Bobbin 29 103 WAR 12 0.49 P 4 0 1AVB
+0.00 F/L Bobbin 29 104 WAR 26 1.60 P 4 0 1AVB
+0.00 F/L H/L-Tubesheet 30 23 VOL 0.51 1 41 TTS-HL
-4.71 TTS-HL Bobbin 30 43 ODI 7
0.99 3 135 10TH TSP
+26.56 F/L Bobbin WAR 7
0.44 P4 0 1AVB
+0.00 F/L C/L Special I VOL 0.75 1 90 10TH TSP
+26.79 9TH TSP Bobbin 30 59 ADI 1.56 3 4 2AVB
+0.73 F/L U-Bend VOL 0.71 1 148 2AVB
+0.16 8TH TSP Bobbin 30- 76 WAR 11 0.58 P 4 0 3AVB
+0.00 F/L Bobbin 30 78 WAR 12 0.60 P 4 0 4AVB
+0.00 F/L Bobbin WAR 14 0.69 P 4 0 3AVB
+0.00 F/L Bobbin WAR 14 0.71 P 4 0 2AVB
+0.00 F/L Bobbin 30 83 WAR 14 0.70 P 4 0 1AVB
+0.00 F/L Bobbin 30 95 WAR 21 1.16 P 4 0 2AVB
+0.00 F/L Bobbin 30 99 WAR 22 1.10 P 4 0 1AVB
+0.00 F/L Bobbin 30 102 WAR 14 0.58 P 4 0 1AVB
+0.00 F/L Bobbin 30 103 WAR 23 1.04 P 4 0 1AVB
+0.00 F/L
~_ _
BWNT TUBAN II (Version'2.1) 07/13/1995 13:50:45 McGuire Nuclear Station - Unit Two eeee****
S/G A 12/94 RFO Bobbin,C/L Special Interest,H/L Special Interest,H/L Tubesheet,U-Bend Page 9 of 12 ATTACHMENT #1 - INDICATIONS OF IMPERFECTIONS INDS OF IMPERFECTIONS - SGA TEST TYPE ROW COL IND %TW VOLTS CHN DEG LOCATION EXTENT 1 Bobbin 30 104 WAR 16 0.65 P 4 0 1AVB
+0.00 F/L Bobbin 31 27 ADI 5.15 6 85 19TH TSP
+2.54 F/L Bobbin IDI 64 11.54.P 1 23 TE-HL
+10.41 F/L C/L Special I VOL 0.63 1 91 19TH TSP
+2.19 19TH TSP H/L Tubesheet 31 49 SAI 0.82 1 30 TTS-HL
+0.00 TTS-HL Bobbin 31 67 ODI 5
1.82 3 138 15TH TSP
+6.90 F/L Bobbin ODI 7
0.48 3 137 15TH TSP
+6.58 F/L C/L Special I VOL 0.28 1 145 ISTH TSP
+7.27 15TH TSP C/L Special I VOL 0.49 1 134 15TH TSP
+7.70 15TH TSP Bobbin 31 84 WAR 27 1.44 P 4 0 3AVB
+0.00 F/L Bobbin 31 89 ODI 3
1.11 3 138 4TH TSP
+27.34 F/L H/L Special I VOL 1.09-1 146 STH TSP
-15.68 STH TSP Bobbin 31 94 ADI 5.63 6 90 11TH TSP
+19.55 F/L C/L Special I VOL 0.66 1 62 11TH TSP
+19.53 11TH TSP Bobbin 31 96 ADI 3.66 6 98 4TH TSP
+14.56 F/L H/L Special I VOL 0.26 1 102 4TH TSP
+14.60 4TH TSP H/L Tubesheet 32 15 SAI 0.32 1 44 TTS-HL
+0.03 TTS-HL Bobbin 32 20 NOI 4.95 P 1 145 TE-HL
+16.86 F/L H/L Tubesheet MAI 6.44 1 23 TTS-HL
-4.43 TTS-HL Bobbin 32 21 ODI 4
1.71 3 137 14TH TSP
+9.12
'F/L C/L Special I VOL 1.14 1 103 13TH TSP
-1.96 13TH TSP H/L Tubesheet 32 23 SAI 0.85 1 14 TTS-HL
+0.00 TTS-HL 4
Bobbin 32 28 ADI 2.46 6 86 11TH TSP
+17.02 F/L Dobbin ADI 2.79 6 77 13TH TSP
+14.05 F/L C/L Special I VOL 0.52 1 52 11TH TSP
+12.14 11TH TSP C/L Special I VOL 0.63 1 72 11TH TSP
+16.03 11TH TSP C/L Special I VOL 0.70 1 113 12TH TSP
-7.90 12TH TSP C/L Special I VOL 0.88 1 98 12TH TSP
-3,47 12TH TSP H/L Tubesheet 32 29 MAI 0.63 1 49 TTS-HL
+0.00 TTS-HL Bobbin 32 30 IDI 53 11.41 P 1 19 TE-HL
+14.34 F/L Bobbin 32 35 IDI 86 13.35 P 1 57 TE-HL
+16.87 F/L Bobbin IDI 92 85.14 P 1 46 TE-HL
+14.83 F/L H/L Tubesheet MAI 10.42 1 38 TTS-HL
-4.64 TTS-HL H/L Tubesheet 32 36 SCI 0.51 1 35 TTS-HL
+0.00 TTS-HL Bobbin 32 43 ADI 1.03 6 88 ISTH TSP
-1.33 F/L Bobbin ODI 5
1.29 3 137 15TH TSP
+4.29 F/L Bobbin ODI 11 1.59 3 133 16TH TSP
+2.23 F/L C/L Special I VOL 0.51 1 99 ISTH TSP
+3.88 15TH TSP C/L Special I VOL 0.82 1 75 16TH TSP
+1.90 16TH TSP Bobbin 32 52 NOI 0.60 3 140 22ND TSP
+4.04 F/L C/L Special I VOL 0.20 1 116 22ND TSP
+4.24 22ND TSP Bobbin 32 57 NQI 0.31 P 1 104 7TH TSP
+0.04 F/L Bobbin 32 71 ODI 3
0.62 3 139 12TH TSP
+33.92 F/L C/L Special I VOL 0.75 1 101 11TH TSP
-10.46 11TH TSP Bobbin 32 97 WAR 13 0.64 P4 0 1AVB
+0.00 F/L H/L Tubesheet 33 25 SAI 0.67 1 40 TTS-HL
+0.00 TTS-HL Bobbin 33 27 ODI 3
1.94 3 138 7TH TSP
+23.88 F/L H/L Special I VOL 2.05 1 108 BTH TSP
-19.88 8TH TSP Bobbin 33 68 ODI 21 1.22 P 4 0 3AVB
+0.00 F/L U-Bend VOL 0.32 P 1 86 3AVB
+0.00 3AVB Bobbin 33 69 NOI 0.91 3 88 10TH TSP
+28.91 F/L Bobbin NOI 0.92 3 141 12TH TSP
+25.79 F/L Bobbin NQI 1.28 3 88 10TH TSP
+20.34 F/L C/L Special I VOL 1.05 1 92 9TH TSP
-15.70 9TH TSP C/L Special I VOL 1.08 1 106 9TH TSP
-24.14 9TH TSP C/L Special I VOL 0.34 1 125 11TH TSP
-19.11 11TH TSP Bobbin 33 77 NOI 6.98 P 1 140 TE-HL
+12.12 F/L H/L Special I MAI 4.17 1 18 TTS-HL
-9.06 TTS-HL H/L Tubesheet 33 93 VOL 0.62 1 111 TTS-HL
+0.87 TTS-HL H/L Tubesheet 34 27 SCI 0.52 1 118 TTS-HL
+0.00 TTS-HL Bobbin 34 29 IDI 72 10.19 P 1 23 TE-HL
+5.13 F/L l
Bobbin 34 57 ODI 11 0.64 3 133 10TH TSP
+21.44 F/L C/L Special I SAI 0.14 1 86 9TH TSP
-22.46 9TH TSP Bobbin 34 58 ODI 4
0.90 3 137 22ND TSP
+10.87 F/L Bobbin 34 82 WAR 18 0.96 P4 0 1AVB
+0.00 F/L 1
I
)
C00*****
BWNT TUBAN II (Varsion 2.1) 07/13/1995 13:50:45 000c****
McGuira Nuclear St* tion - Unit Two oce*****
S/G A 12/94 RFO
- ce*co***.
Bobbin,C/L Special Interest,H/L Special Interest,H/L Tubesheet,U-Bend Page 10 of 12 ATTACHMENT #1 - INDICATIONS OF IMPERFECTIONS INDS OF IMPERFECTIONS - SGA TEST TYPE ROW COL IND %TW VOLTS CHN DEG LOCATION EXTENT 1 Bobbin 35 16 ADI 3.16 6 81 GTH TSP
+3.40 F/L H/L Special I VOL 0.60 1 105 6TH TSP
+3.73 6TH TSP Bobbin 35 21 ADI 4.39 6 79 22ND TSP
+8.77 F/L C/L Special I VOL 0.60 1 116 22ND TSP
+8.77 22ND TSP C/L Special I VOL 0.79 1 147 22ND TSP
+12.99 22ND TSP C/L Special I VOL 0.79 1 158 22ND TSP
+5.51 22ND TSP C/L Special I VOL 0.95 1 141 22ND TSP
+6.90 22ND TSP H/L Tubesheet 35 24 SCI 0.22 1 80 TTS-HL
-0.07 TTS-HL Bobbin 35 35 ADI 3.77 6 91 17TH TSP
+7.33 F/L C/L Special I VOL 0.74 1 154 17TH TSP
+7.33 16TH TSP Bobbin 35 49 IDI 44 5.77 P 1 103 TE-HL
+7.22 F/L Bobbin 35 72 IDI 67 11.15 P 1 87 TE-HL
+11.92 F/L H/L Special I MAI 6.63 1 35 TTS-HL
-8.93 TTS-HL Bobbin 35 75 ADI 3.64 6 83 3RD TSP
+21.83 F/L H/L Special I VOL 0.25 1 99 3RD TSP
+21.38 3RD TSP Bobbin 35 79 WAR 21 1.19 P 4 0 2AVB
+0.00 F/L Bobbin 35 83 WAR 22 1.31 P 4 0 1AVB
+0.00 F/L Bobbin 35 84 ADI 2.85 6 76 13TH TSP
+16.12 F/L C/L Special I VOL 0.65 1 142 13TH TSP
+15.56 13TH TSP Bobbin 36 23 ADI 5.66 6 69 12TH TSP
+22.28 F/L Bobbin ADI 7.29 6 79 12TH TSP
+30.43 F/L C/L Special I VOL 0.35 1 104 12TH TSP
+22.28 12TH TSP C/L Special I VOL 1.12 1 119 12TH TSP
+30.43 12TH TSP H/L Tubesheet 36 24 SCI 0.47 1 49 TTS-HL
-0.08 TTS-HL H/L Tubesheet 36 26 SAI 2.38 1 22 TTS-HL
+0.18 TTS-HL Bobbin 36 38 ODI 6
5.13 4 144 11TH TSP
+19.45 F/L C/L Special I VOL 3.42 1 11 11TH TSP
+19.45 11TH TSP Bobbin 36 44 IDI 35 6.68 P 1 39 TE-HL
+17.84 F/L H/L Tubesheet SAI 9.96 1 31 TTS-HL
-3.52 TTS-HL Bobbin 36 49 ADI 2.12 6 59 3RD TSP
+7.80 F/L Bobbin ADI 3.08 6 45 STH TSP
+3.41 F/L H/L Special I VOL 0.50 1 131 STH TSP
+10.23 STH TSP H/L Special I VOL 0.71 1 88 3RD TSP
+7.97 3RD TSP H/L Special I VOL 0.85 1 124 STH TSP
+3.51 STH TSP Bobbin 36 63 IDI 72 12.56 P 1 80 TE-HL
+15.08 F/L H/L Special I MAI 8.63 1 209 TTS-HL
-6.32 TTS-HL Bobbin 36 67 ADI 2.60 6 55 6TH TSP
+30.84 F/L Bobbin WAR 28 2.05 P 4 0 1AVB
+0.00 F/L H/L Special I VOL 0.27 1 32 7TH TSP
-13.09 7TH TSP Bobbin 36 86 ADI 3.59 6 81 6TH TSP
+6.48 F/L H/L Special I VOL 0.88 1 112 6TH TSP
+6.64 6TH TSP Bobbin 36 87 ADI 2.10 6 88 STH TSP
+38.46 F/L H/L Special I VOL 0.72 1 94 6TH TSP
-5.19 6TH TSP Bobbin 36 88 WAR 22 1.29 P 4 0 1AVB
+0.00 F/L Bobbin 37 23 IDI 45 3.61 P 1 102 TE-HL
+2.83 F/L H/L Tubesheet SCI 0.77 1 34 TTS-HL
-0.07 TTS-HL Bobbin 37 45 IDI 59 11.96 P 1 17 TE-HL
+12.36 F/L H/L Special I MAI 4.27 1 17 TTS-HL
-8.54 TTS-HL H/L Tubesheet 37 46 SAI 0.64 1 28 TTS-HL
-2.32 TTS-HL Bobbin 37 62 ADI 7.48 6 109 BTH TSP
+24.90 F/L U-Bend VOL 0.72 P 1 120 STH TSP
+24.23 8TH TSP.
Bobbin 37 88 NQI 0.56 3 73 18TH TSP
+14.55 F/L C/L Special I VOL 1.07 1 104 18TH TSP
+14.92 18TH TSP Bobbin 37 98 NOI 0.61 P 1 101 16TH TSP
-0.32 F/L C/L Special I VOL 0.54 P 1 139 16TH TSP
-0.29 16TH TSP Bobbin 38 19 ADI 7.46 6 86 14TH TSP
+9.54 F/L C/L Special I VOL 1.27 1 95 14TH TSP
+9.30 13TH TSP Bobbin 38 21 ADI 4.19 6 75 10TH TSP
+21.84 F/L C/L Special I VOL 0.57 1 150 10TH TSP
+21.74 10TH TSP Bobbin 38 35 IDI 81 16.38 P 1 68 TE-HL
+11.19 F/L H/L Tubesheet 38 40 NQI 0.98 1 154 TTS-HL
-0.12 TTS-HL Bobbin 38 45 NQI 11.69 P 1 163 TE-HL
+7.29 F/L Bobbin IDI 82 12.33 P 1 28 TE-HL
+10.32 F/L Bobbin IDI 99 22.05 P 1 36 TE-HL
+9.23 F/L H/L Tubesheet 38 46 SAI 0.32 1 37 TTS-HL
-4.71 TTS-HL l
BWNT TUBAN II (Version 2.1) 07/13/1995 13:50:45 McGuire Nuclear Station - Unit Two S/G A 12/94 RFO Bobbin,C/L Special Interest,H/L Special Interest,H/L Tubesheet,U-Bend ATTACHMENT #1 - INDICATIONS OF IMPERFECTIONS INDS OF IMPERFECTIONS - SGA TEST TYPE ROW COL IND %TW VOLTS CHN DEG LOCATION EXTENT 1 Bobbin 38 49 ADI 2.71 6 83 STH TSP
+16.81 F/L Bobbin ADI 5.18 6 92 STH TSP
+20.40 F/L H/L Special I VOL 0.73 1 127 STH TSP
+18.52 STH TSP H/L Special I VOL 0.82 1 114 STH TSP
+16.75 STH TSP H/L Special I VOL 2.09 1 109 STH TSP
+20.12 STH TSP Bobbin 38 50 NOI 0.69 3 111 7TH TSP
+23.42 F/L Bobbin NQI 0.49 3 129 22ND TSP
+16.74 F/L H/L Special I VOL O.71 1 84 7TH TSP
+23.26 7TH TSP Bobbin 38 52 NOI 8.56 P 1 164 TE-HL
+12.83 F/L Bobbin 38 54 ADI 4.76 6 81 STH TSP
+13.27 F/L Bobbin 38 55 WAR 28 2.07 P 4 0 1AVB
+0.00 F/L Bobbin 38 57 IDI 90 16.47 P1 53 TE-HL
+14.11 F/L H/L Special I SAI 11.78 1 25 TTS-HL
-6.78 TTS-HL Bobbin 38 59 WAR 28 2.07 P 4 0 3AVB
+0.00 Fl L Bobbin 38 63 IDI 31 14.75 P 1 13 TE-HL
+8.70 F/L H/L Special I SAI 3.88 1 18 TTS-HL
-13.32 TTS-HL Bobbin 38 76 IDI 29 5.85 P 1 116 TE-HL
+14.69 F/L Bobbin 38 91 IDI 41 9.49 P 1 108 TE-HL
+7.15 F/L Bobbin IDI 55 5.21 P 1 97 TE-HL
+2.45 F/L Bobbin IDI 74 13.46 P 1 77 TE-HL
+11.12 F/L H/L Special I MAI 6.15 1 36 TE-HL
+2.12 TTS-HL H/L Special I MAI 6.80 1 26 TE-HL
+6.48 TTS-HL H/L Special I MAI 10.33 1 33 TE-HL
+10.54 TTS-HL Bobbin 39 18 WAR 17 0.92 P 4 0 3AVB
+0.00 F/L Bobbin 39 19 WAR 23 1.40 P 4 0 2AVB
+0.00 F/L Bobbin 39 32 IDI 91 28.70 P 1 52 TE-HL
+11.37 F/L Bobbin 39 36 NQI 5.71 P 1 25 TE-HL
+5.91 F/L Bobbin IDI 62 7.45 P 1 89 TE-HL
+3.62 F/L t
Bobbin 39 43 WAR 15 0.80 P 4 0 1AVB
+0.00 F/L Bobbin 39 48 ADI 3.16 6 60 10TH TSP
+11.10 F/L C/L Special I VOL 0.39 1 112 10TH TSP
+11.10 10TH TSP Bobbin 39 52 WAR 12 0.58 P 4 0 2AVB
+0.00 F/L Bobbin WAR 15 0.80 P 4 0 1AVB
+0.00 F/L Bobbin 39 57 IDI 75 4.73 P 1 76 TE-HL
+9.42 F/L Bobbin 39 63 ADI 2.26 6 88 12TH TSP
+7.13 F/L Bobbin 39 65 WAR 17 0.75 P 4 0 1AVB
+0.00 F/L Bobbin 39 70 WAR 15 0.62 P 4 0 4AVB
+0.00 F/L I
Bobbin WAR 25 1.35 P 4 0 1AVB
+0.00 F/L i
Bobbin WAR 27 1.50 P 4 0 2AVB
+0.00 F/L Bobbin WAR 31 2.07 P 4 0 3AVB
+0.00 F/L Bobbin 39 71 WAR 37 3.42 P 4 0 2AVB
+0.00 F/L U-Bend VOL 1.90 P 1 7 2AVB
+0.00 8TH TSP Bobbin 40 24 WAR 9
0.47 P 4 0 3AVB
+0.00 F/L Bobbin 40 27 IDI 39 14.30 P 1 12 TE-HL
+16.25 F/L H/L Tubesheet MAI 3.25 1 32 TTS-HL
-6.02 TTS-HL H/L Special I MAI 2.80 1 27 TTS-HL
-4.50 TTS-HL Bobbin 40 29 NOI 3.81 P 1 146 TE-CL
+14.48 F/L 1
Bobbin 40 32 WAR 35 3.32 P 4 0 2AVB
+0.00 F/L Bobbin WAR 36 3.75 P 4 0 3AVB
+0.00 F/L U-Bend VOL 1.03 P 1 97 2AVB
+0.00
'8TH TSP U-Bend VOL 1.06 P 1 98 3AVB
+0.00 8TH TSP Bobbin 40 36 NOI 0.53 3 135 12TH TSP
+1.29 F/L Bobbin WAR 24 1.54 P 4 0 2AVB
+0.00 F/L l
C/L Special I VOL 0.68 1 134 12TH TSP
+1.26 12TH TSP Bobbin 40 42 WAR 18 1.00 P 4 0 1AVB
+0.00 F/L Bobbin 40 48 NOI 0.88 3 108 IST TSP
+13.07 F/L H/L Special I VOL 1.29 1 121 2ND TSP
-8.80 2ND TSP H/L Special I VOL 1,32 1 111 2ND TSP
-7.04 2ND TSP Bobbin 40 63 IDI 76 11.21 P 1 26 TE-HL
+15.33 F/L Bobbin 40 70 WAR 24 1.24 P 4 0 3AVB
+0.00 F/L Bobbin WAR 35 2.79 P 4 0 2AVB
+0.00 F/L U-Bend VOL 0.72 P 1 31 1AVB
+0.00 8TH TSP U-Bend VOL 1.01 P 1 14 3AVB
+0.00 8TH TSP U-Bend VOL 1.60 P 1 4 2AVB
+0.00 8TH TSP Bobbin 41 47 NQI 0.46 3 83 4TH TSP
+10.88 F/L
BWNT TUBAN II (Version 2.1) 07/13/1995 13:50:45 McGuire Nuclear Station - Unit Two S/G A
- e******
12/94 RFO Bobbin,C/L Special Interest,H/L Special Interest,H/L Tubesheet,U-Bend Page 12 of 12 ATTACHMENT #1 - INDICATIONS OF IMPERFECTIONS INDS OF IMPERFECTIONS - SGA TEST TYPE ROW COL IND %TW VOLTS CHN DEG LOCATION EXTENT 1 H/L Special I VOL 0.60 1 97 4TH TSP
+10.58 4TH TSP Bobbin 41 51 WAR 17 0.95 P 4 0 1AVB
+0.00 F/L Bobbin 41 55 WAR 29 2.20 P 4 0 1AVB
+0.00 F/L Bobbin 41 74 WAR 22 1.43 P 4 0 1AVB
+0.00 F/L Bobbin 41 75 ODI 91 9.52 P 1 31 TE-HL
+6.53 F/L Bobbin 41 78 ODI 8
2.50 3 135 4TH TSP
+16.83 F/L Bobbin WAR 19 1.22 P 4 0 1AVB
+0.00 F/L H/L Special I VOL 2.19 1 111 4TH TSP
+17.02 4TH TSP Bobbin 41 88 IDI 79 12.95 P 1 27 TE-HL
+13.23 F/L H/L Special I SAI 4.92 1 24 TTS-HL
-7.64 TTS-HL H/L Tubesheet 42 40 SAI 0.71 1 32 TTS-HL
+0.00 TTS-HL Bobbin 42 62 WAR 25 1.71 P 4 0 1AVB
+0.00 F/L Bobbin 42 76 IDI R6 8.23 P 1 32 TE-HL
+7.85 F/L Bobbin 42 78 WAR 25 1.64 P4 0 1AVB
+0.00 F/L Bobbin 43 46 WAR 19 0.99 P 4 0 1AVB
+0.00 F/L Bobbin 43 51 ADI 1.79 6 77 22ND TSP
+12.17 F/L C/L Special I VOL 0.64 1 28 22ND TSP
+12.17 21ST TSP H/L Tubesheet 43 65 SAI 0.59 1 24 TTS-HL
+0.00 TTS-HL Bobbin 43 68 NQI 16.62 P 1 28 TE-HL
+13.38 F/L Bobbin 44 31 NQI 0.71 3 92 15TH TSP
+8.46 F/L C/L Special I VOL 0.83 1 123 15TH TSP
+8.51 15TH TSP Bobbin 44 56 NOI 0.93 P 1 118 9TH TSP
-0.50 F/L C/L Special I VOL 0.19 P 1 33 9TH TSP
-0.57 9TH TSP Bobbin 44 57 IDI 90 37.15 P 1 50 TE-HL
+14.05 F/L Bobbin 44 61 IDI 70 13.65 P 1 26 TE-HL
+10.21 F/L Bobbin IDI 72 24.38 P 1 81 TE-HL
+8.33 F/L Bobbin 44 63 IDI 73 21.34 P 1 27 TE-HL
+7.59 F/L Bobbin 45 28 ODI 12 4.10 4 140 10TH TSP
+28.85 F/L C/L Special I VOL 0.28 1 70 10TH TSP
+31.83 10TH TSP C/L Special I VOL 1.45 1 118 10TH TSP
+28.31 10TH TSP Bobbin 45 31 IDI 33 10.35 P 1 10 TE-HL
+17.17 F/L H/L Special I SAI 1.13 1 15 TTS-HL
-3.71 TTS-HL Bobbin 45 51 IDI 94 64.19 P 1 42 TE-HL
+14.38 F/L Bobbin 46 47 NOI 0.69 3 111 STH TSP
+29.79 F/L H/L Special I VOL 0.42 1 107 6TH TSP
-14.48 6TH TSP Bobbin 47 57 NQI 11.17 P 1 20 TE-HL
+7.57 F/L Bobbin 47 66 ADI 4.83 6 88 3RD TSP
+17.04 F/L H/L Special I VOL 1.09 1 118 3RD TSP
+17.48 3RD TSP Bobbin 47 87 NOI 0.31 P 1 73 3RD TSP
+0.05 F/L Bobbin 48 53 NOI 0.54 3 113 11TH TSP
+28.28 F/L C/L Special I VOL 0.94 1 112 11TH TSP
+28.36 11TH TSP H/L Tubesheet 49 41 VOL 0.52 1 110 TTS-HL
-0.09 TTS-HL Bobbin 49 64 ODI 8
1.08 3 136 STH TSP
+16.57 F/L H/L Special I VOL 0.94 1 114 STH TSP
+16.48 STH TSP Bobbin 49 65 ADI 4.75 6 87 12TH TSP
+35.52 F/L C/L Special I VOL 0.80 1 107 11TH TSP
-9.64 11TH TSP Bobbin 49 71 IDI 63 16.01 P 1 22 TE-HL
+4.80 F/L Bobbin 49 74 WAR 10 2.53 P 2 0 15TH TSP
+0.00 F/L Total Indications Found = 763 Total Tubes Found = 408
1 BWNT TUBAN II (Varzion 2.1) 07/13/1995 13:43:23 McGuire Nuclcer Station - Unit Two S/G B e
oo*ee***
12/94 RFO Bobbin,C/L_Special Interest,H/L Special Interest,H/L Tubesheet,U-Bend ATTACHMENT #2 -' INDICATIONS OF IMPERFECTIONS INDS OF IMPERFECTIONS - SGB TEST TYPE ROW COL IND %TW VOLTS CHN DEG LOCATION EXTENT 1 Bobbin 2 46 IDI 40 12.05 P 1 24 TE-HL
+12.27 9TH TSP H/L Special I SAI 3.98 1 26 TTS-HL
-8.78
.TTS-HL H/L Tubesheet 2 51 SAI 1.08 1 59 TTS-HL
-0.04 TTS-HL H/L Tubesheet 2 54 SAI 1.25 1 45 TTS-HL
-0.09 TTS-HL H/L Tubesheet 2 106 SAI 1.56 1 28 TTS-HL
+0.01 TTS-HL H/L Tubesheet 2 108 MAI 1.66 1 21 TTS-HL
-0.04 TTS-HL Bobbin 3 13 NQI 0.55 P 1 58 STH TSP
-0.07 9TH TSP H/L Special I SAI 0.75 1 36 STH TSP
-0.01 STH TSP Bobbin 3 16 ODI 14 5.08 3 133 10TH TSP
+1.75 9TH TSP C/L Special I VOL 1.62 1 100 10TH TSP
+2.32 10TH TSP H/L Tubesheet 3 85 SAI 0.92 1 30 TTS-HL
+0.16 TTS-HL Bobbin 3 86 ADI 4.83 6 87 12TH TSP
+5.59 9TH TSP C/L Special I VOL 0.67 1 125 12TH TSP
+14.61 12TH TSP C/L Special I VOL O.97 1 107 12TH TSP
+3.09 12TH TSP C/L Special I VOL 1.02 1 115 12TH TSP
+5.14 12TH TSP Bobbin 3 107 ADI 4.38 6 78 IST TSP
+5.72 9TH TSP Bobbin 4 12 ODI 12 1.94 4 152 13TH TSP
+4.75 9TH TSP I
H/L Tubesheet 4 18 VOL 0.64 1 152 ITS-HL
+0.50 TTS-HL H/L Tubesheet VOL 1.28 1 144 TTS-HL
+2.24 TTS-HL Bobbin 4 20 ADI 7.42 6 51 4TH TSP
+9.55 9TH TSP i
Bobbin ODI 8
2.55 4 133 4TH TSP
+25.51 9TH TSP H/L Special I VOL 0.84 1 131 4TH TSP
+5.35 4TH TSP j
H/L Special I VOL 1.32 1 140 4TH TSP
+9.29 4TH TSP H/L Special I VOL 2.28 1 125 4TH TSP
+25.58 4TH TSP Bobbin 4 23 ODI 4
1.71 3 149 STH TSP
+39.76 9TH TSP Bobbin ADI 6.24 6 78 12TH TSP
+39.33 9TH TSP H/L Special I VOL 1.52 1 158 6TH TSP
-4.53 6TH TSP C/L Special I VOL 0.68 1 43 11TH TSP
-5.21 11TH TSP Bobbin 4 37 IDI 50 15.76 P 1 18 TE-HL
+3.71 9TH TSP H/L Tubesheet 4 51 SAI 1.88 1 16 TTS-HL
-0.17 TTS-HL Bobbin 4 65 NQI 3.09 3 161 4TH TSP
+29.18 9TH TSP Bobbin 4 73 IDI 50 11.87 P 1 15 TE-HL
+15.07 9TH TSP H/L Special I MAI 0.46 1 16 TE-HL
+14.29 TTS-HL Bobbin 4 97 ADI 9.27 6 80 2ND TSP
+22.14 9TH TSP H/L Jpecial I VOL 1.28 1 131 3RD TSP
-2,18 3RD TSP Bobbin 5 42 IDI 33 10.50 P 1 12 TE-HL
+17.53 9TH TSP H/L Tubesheet MAI 0.52 1 24 TTS-HL
-3.09 TTS-HL Bobbin 5 70 IDI 98 27.30 P 1 53 TE-HL
+4.10 9TH TSP H/L Tubesheet SAI 0.26 1 25 TTS-HL
+0.00 TTS-HL Bobbin 5 95 ODI 16 0.70 3 132 6TH TSP
+21.71 9TH TSP H/L Special I VOL 0.27 1 82 6TH TSP
+21.72 6TH TSP C/L Special I 5 98 VOL 0.38 1 93 14TH TSP
+2.03 14TH TSP C/L Special I VOL 0.45 1 115 14TH TSP
+3.51 14TH TSP C/L Special I VOL 0.51 1 59 14TH TSP
+0.51 14TH TSP Bobbin 5 113 IDI 27 8.18 P 1 10 TE-HL
+15.95 9TH TSP Bobbin 6 42 ADI 2.86 6 56 12TH TSP
+22.95 F/L Bobbin ADI 4.22 6 59 12TH TSP
+35.85 F/L Bobbin ODI 15 0.76 3 134 12TH TSP
+19.46 F/L C/L Special I VOL 0.37 1 34 11TH TSP
-14.18 11TH TSP C/L Special I VOL 0.47 1 36 11TH TSP
-9.66 11TH TSP C/L Special I VOL 0.69 1 22 11TH TSP
-17.86 11TH TSP C/L Special I VOL 0.89 1 22 11TH TSP
-24.24 11TH TSP C/L Special I VOL 0.91 1 31 11TH TSP
-22.07 11TH TSP Bobbin 6 45 ADI 2.56 6 68 11TH TSP
+24.23 F/L Bobbin ODI 14 1.87 4 135 10TH TSP
+25.53 F/L Bobbin ODI 15 0.88 3 134 10TH TSP
+5.81 F/L Bobbin ODI 30 0.62 3 119 10TH TS9
+17.74 F/L C/L Special I VOL 0.90 1 136 9TH TEP
-18.58 9TH TSP C/L Special I VOL 1.18 1 143 9TH TSP
-20.64 9TH TSP C/L Special I VOL 0.56 1 132 10T;I TSP
-20.83 10TH TSP C/L Special I VOL 1.01 1 29 10TU TSP
+19.05 10TH TSP Bobbin 6 46 NOI 1.19 3 110 17TH TSP
+5.50 F/L H/L Tubesheet 6 54 MAI 1.24 1 36 TTS-HL
-3.00 TTS-HL H/L Tubesheet SAI 0.63 1 21 TTS-HL
-0.04 TTS-HL Bobbin 6 69 IDI 58 8.86 P 1 19 TE-HL
+8.81 F/L
BWNT TUBAN II (Version 2.1) 07/13/1995 13:43:23 McGuire Nuclear Station - Unit Two S/G B 12/54 RFO Bobbin,C/L Special Interest,H/L Special Interest,H/L Tubesheet,U-Bend Page 2 of 13 ATTACHMENT #2 - INDICATIONS OF IMPERFECTIONS INDS OF IMPERFECTIONS-- SGB TEST TYPE ROW COL IND %TW VOLTS CHN DEG LOCATION EXTENT 1 Bobbin 6 70 IDI 67 13.55 P 1 22 TE-HL
+7.63 F/L H/L Special I MAI 1.46 1 18 TE-HL
+7.08 TTS-HL Bobbin 6 77 IDI 45 10.10 P 1 15 TE-HL
+6.59 F/L Bobbin 6 82 ODI 11 1.37 4 144 12TH TSP
+27.71 F/L C/L Special I VOL 0.64 1 103 11TH TSP
-17.25 11TH TSP Bobbin 6 104 ADI 3.05 6 85 TTS-CL
+4.67 F/L H/L Tubesheet 6 109 VOL 1.14 1 161 TTS-HL
+2.16 TTS-HL Bobbin 7
4 NQI 0.60 P 1 51 5TH TSP
+0.03 F/L H/L Special I SAI 0.47 1 11 STH TSP
-0.10 STH TSP Bobbin 7 12 NQI 7.36 P 1 18 TTS-HL
-1.17 F/L Bobbin 7 52 NOI 0.30 3 124 6TH TSP
+10.76 F/L Bobbin 7 56 NQI 13.62 P 1 168 TE-HL
+12.20 F/L Bobbin 7 67 ODI 10 0.67 3 139 3RD TSP
+30.26 F/L H/L Tubesheet 7 76 VOL 1.54 1 156 TTS-HL
+0.64 TTS-HL Bobbin 7 91 ODI 17 2.92 4 139 STH TSP
+15.23 F/L H/L Special I VOL 1.16 1 115 STH TSP
+14.93 STH TSP Bobbin 7 94 IDI 42 7.27 P 1 106 TE-HL
+11.29 F/L Bobbin IDI 50 7.58 P 1 16 TE-HL
+12.49 F/L H/L Special I MAI 1.49 1 27 TE-HL
+11.93 TTS-HL H/L Special I SAI 5.44 1 48 TE-HL
+10.56 TTS-HL H/L Tubesheet 7 96 SAI 0.80 1 41 TTS-HL
+0.00 TTS-HL Bobbin 7 97 IDI 73 15.59 P 1 24 TE-HL
+3.04 F/L Bobbin 8 56 ODI 4
1.26 3 145 22ND TSP
+13.11 F/L Bobbin ODI 22 1.22 3 127 22ND TSP
+9.20 F/L C/L Special I VOL 2.08 1 132 22ND TSP
+9.54 22ND TSP Bobbin 8 74 ODI 11 1.40 4 140 3RD TSP
+10.34 F/L H/L Special I VOL 0.66 1 54 3RD TSP
+10.42 3RD TSP Bobbin 8 78 ODI 15 1.98 3 134 4TH TSP
+15.56 F/L H/L Special I VOL 2.00 1 118 4TH TSP
+15.59 4TH TSP H/L Tubesheet 8 86 SAI 0.41 1 66 TTS-HL
+0.00 TTS-HL H/L Tubesheet 8 87 SAI 1.25 1 9 TTS-HL
-0.07 TTS-HL Bobbin 8 93 ADI 3.59 6 65 IST TSP
+5.12 F/L H/L Special I VOL 0.30 1 125 IST TSP
+5.37 IST TSP Bobbin 8 104 ADI 4.78 6 48 IST TSP
+7.25 F/L I
Bobbin NQI 10.70 P 1 155 TE-HL
+7.60 F/L Bobbin ODI 12 1.91 4 141 IST TSP
+9.02 F/L H/L Special I MAI 4.95 1 14 TE-HL
+7.21 TTS-HL H/L Special I VOL 0.80 1 129 2ND TSP
-13.27 2ND TSP H/L Special I VOL 1.17 1 149 2ND TSP
-11.71 2ND TSP Bobbin 8 106 ODI 23 0.80 4 130 3RD TSP
+31.67 F/L Bobbin 8 109 ADI 4.72 6 81 4TH TSP
+2.06 F/L H/L Special I VOL 0.89 1 123 4TH TSP
+2.43 4TH TSP Bobbin 9
5 ADI 3.04 6 96 STH TSP
+23.03 F/L Bobbin 9
7 ADI 7.04 6 81 10TH TSP
+10.89 F/L Bobbin OLI 6
1.71 3 140 15TH TSP
+1.52 F/L C/L Special I VOL 0.83 1 123 10TH TSP
+9.56 10TH TSP C/L Special I VOL 1.36 1 111 ISTH TSP
+1.87 15TH TSP Bobbin 9
9 NQI 0.70 3 110 12TH TSP
+40.21 F/L C/L Special I VOL 1.47 1 147 11TH TSP
-3.60 11TH TSP Bobbin 9 34 ODI 14 1.70 3 132 22ND TSP
+3.21 F/L Bobbin 9 56 NQI 0.49 3 117 12TH TSP
+34.29 F/L Bobbin 9 75 ADI 4.26 6 68 3RD TSP
+10.16 F/L Bobbin ADI 2.98 6 61 10TH TSP
+35.89 F/L Bobbin ODI 20 0.58 4 133 10TH TSP
+42.11 F/L H/L Special I VOL 0.90 1 114 3RD TSP
+9.45 3RD TSP C/L Special I VOL 0.10 1 138 10TH TSP
+41.94 10TH TSP C/L Special I VOL 0.72 1 158 10TH TSP
-+35.33 10TH TSP H/L Tubesheet 9 76 SAI 1.15 1 19 TTS-HL
+0.13 TTS-HL H/L Tubesheet 9 84 SAI 0.63 1 32 TTS-HL
+0.00 TTS-HL l
Bobbin 9 91 NOI 0.55 3 129 4TH TSP
+12.86 F/L H/L Tubesheet SAI 0.67 1 35 TTS-HL
+0.06 TTS-HL i
H/L Special I VOL 0.75 1 38 4TH TSP
+12.89 4TH TSP 1
Bobbin 9 92 ODI 13 1.86 4 140 TTS-CL
+4.57 F/L C/L Special I VOL 0.88 1 135 TTS-CL
+3.69 22ND TSP Bobbin 9 98 NQI 0.95 3 113 IST TSP
+7.25 F/L 1
e*******
BWNT TUBAN II (Varsion 2.1) 07/13/1995 13:43:23 McGuire Nuclear Station - Unit Two S/G B 12/94 RFO Bobbin,C/L Special Interest,H/L Special Interest,H/L Tubesheet,U-Bend ATTACHMENT #2 - INDICATIONS OF IMPERFECTIONS INDS OF IMPERFECTIONS - SGB TEST TYPE ROW COL IND %TW VOLTS CHN DEG LOCATION EXTENT 1 H/L Special I VOL 1.49 1 167 IST TSP
+6.97 IST TSP Bobbin 9 104 ADI 3.66 6 50 2ND TSP
+16.69 F/L Bobbin ODI 15 1.66 4 138 3RD TSP
+21.09 F/L Bobbin ODI 19 1,43 4 134 3RD TSP
+30.22 F/L H/L Special I VOL 0.25 1 167 2ND TSP
+16.65 2ND TSP H/L Special I VOL 0.95 1 138 3RD TSP
+20.74 4TH TSP H/L Special I VOL 1.23 1 160 3RD TSP
+29.97 4TH TSP Bobbin 9 108 IDI 57 14.13 P 1 78 TE-HL
+14.92 F/L Bobbin 10 6 ODI 12 0.94 3 137 20TH TSP
+5.22 F/L C/L Special I VOL 0.68 1 105 20TH TSP
+4.86 19TH TSP Bobbin 10 14 NQI 0.45 P 1 93 2ND TSP
+0.11 F/L H/L Special I SAI 0.41 1 32 2ND TSP
+0.06 2ND TSP Bobbin 10 24 ODI 5
1.73 3 144 TTS-CL
+6.78 F/L C/L Special I VOL 0.49 1 142 TTS-CL
+6.57 22ND TSP Bobbin 10 34 ADI 2.59 6 99 STH TSP
+19.66 F/L Bobbin 10 59 NQI 0.58 3 108 2ND TSP
-1.30 F/L Bobbin IDI 94 42.65 P 1 31 TE-HL
+12.34 F/L H/L Tubesheet SAI 1.06 1 15 TTS-HL
+0.00 TTS-HL Bobbin 10 60 ODI 17 0.67 3 132 12TH TSP
+7.96 F/L C/L Special I VOL 0.73 1 124 12TH TSP
+7.81 12TH TSP I
Bobbin 10 64 ODI 4
1.71 3 145 3RD TSP
+10.59 F/L-l H/L Special I VOL 0.59 1 81 3RD TSP
+9.95 3RD TSP
'/
Bobbin 10 67 IDI 99 10.40 P 1 25 TE-HL
+2.81 F/L Bobbin 10 70 ODI 20 1.15 4 133 IST TSP
+4.41 F/L H/L Special I VOL 0.93 1 155 IST TSP
+3.85 IST TSP Bobbin 10 79 ODI 6
1.78 3 143 7TH TSP
+11.07 F/L H/L Special I VOL 0.74 1 125 7TH TSP
+10.96 7TH TSP Bobbin 10 80 ODI 15 0.67 3 134 22ND TSP
+8.90 F/L Bobbin 10 82 NQI 0.56 P 1 58 3RD TSP
+0.08 F/L H/L Special I SAI 0.39 P 1 154 3RD TSP
+0.03 3RD TSP Bobbin 10 96 ADI 4.60 6 52 4TH TSP
+12.59 F/L H/L Special I VOL 1.10 1 91 4TH TSP
+13.08 4TH TSP H/L Special I VOL 1.39 1 127 4TH TSP
+8.88 4TH TSP Bobbin 10 98 ODI 10 2.21 3 139 4TH TSP
+2P.34 F/L H/L Special I VOL 0.85 1 115 STH TSP
-13.64 STH TSP Bobbin 10 113 ADI 2.18 6 33 12TH TSP
+3.77 F/L Bobbin NQI 0.44 3 100 12TH TSP
+7.80 F/L C/L Special I VOL 0.18 1 51 12TH TSP
+8.18 12TH TSP C/L Special I VOL 0.27 1 85 12TH TSP
+3.72 12TH TSP Bobbin 11 4 ADI 2.06 6 81 18TH TSP
+7.19 F/L C/L Special I VOL 0.32 1 128 18TH TSP
+6.81 18TH TSP C/L Special I VOL 0.37 1 128 18TH TSP
+3.43 18TH TSP Bobbin 11 7 NQI 1.77 3 147 18TH TSP
+12.87 F/L C/L Special I VOL 0.81 1 102 1BTH TSP
+12.65 18TH TSP Bobbin 11 19 NQI 0.8e P1 36 2ND TSP
+0.00 F/L H/L Special I SAI 0.57 1 42 2ND TSP
+0.01 2ND TSP Bobbin 11 22 NQI 0.67 3 107 18TH TSP
+3.28 F/L C/L Special I VOL 1.63 1 89 18TH TSP
+3.33 18TH TSP Bobbin 11 25 ODI 11 0.40 3 133 11TH TSP
+24.21 F/L C/L Special I VOL 0.17 1 107 11TH TSP
+23.45 10TH TSP Bobbin 11 29 ODI 4
1.54 3 139 1ST TSP
+3.47 F/L H/L Special I VOL 0.88 1 108 IST TSP
+3.26 IST TSP Bobbin 11 48 IDI 65 13.86 P 1 84 TE-HL
+4.65 F/L Bobbin 11 52 ODI 13 1.49 3 132 11TH TSP
+18.20 F/L C/L Special I VOL 1.52 1 150 11TH TSP
+18.38 10TH TSP Bobbin 11 58 IDI 56 6.75 P 1 18 TE-HL
+16.13 F/L H/L Special I SAI 0.53 1 54 TE-HL
+15.42 TTS-HL Bobbin 11 70 NOI 7.16 P 1 161 TE-HL
+16.84 F/L H/L Tubesheet MAI 3.13 1 21 TTS-HL
-4.39 TTS-HL Bobbin 11 77 IDI 69 14.01 P 1 82 TE-HL
+10.12 F/L H/L Special I MAI 7.76 1 40 TE-HL
+9,83 TTS-HL Bobbin 11 79 ADI 4.43 6 70 10TH TSP
+24.58 F/L C/L Special I VOL 0.92 1 113 9TH TSP
-19.58 9TH TSP Bobbin 11 82 ODI 26 0.83 3 122 6TH TSP
+37.97 F/L H/L Special I VOL 0.56 1 136 7TH TSP
-6.23 7TH TSP
BWNT TUBAN II (Version 2.1) 07/13/1995 13:43:23
~********
McGuire Huclear Station - Unit Two S/G B 12/94 RFO Bobbin,C/L Special Interest,H/L Special Interest,H/L Tubesheet,U-Bend Page 4 of 13 ATTACHMENT #2 - INDICATIONS OF IMPERFECTIONS INDS OF IMPERFECTIONS - SGB TEST TYPE ROW COL IND %TW VOLTS CHN DEG LOCATION EXTENT 1 Bobbin 11 86 NOI 1.52 P 1 37 TE-HL
+4.96 F/L Bobbin 11 87 ADI 2.88 6 83 14TH TSP
+5.69 F/L Bobbin ODI 10 0.54 3 138 4TH TSP
-3.94 F/L Bobbin ODI 32 0.45 3 116 11TH TSP
+14.31 F/L C/L Special I VOL 0.10 1 94 11TH TSP
+15.27 11TH TSP C/L Special I VOL 0.17 1 98 14TH TSP
+5.69 13TH TSP.
Bobbin 11 89 ODI 34 1.59 3 114 11TH TSP
-1.51 F/L C/L Special I VOL 1.36 1 113 11TH TSP
-1.38 11TH TSP Bobbin 11 90 NQI 0.66 3 117 6TH TSP
+38.55 F/L Bobbin ODI 28 0.84 3 120 6TH TSP
+40.22 F/L H/L Special I VOL 0.21 1 78 7TH TSP
-3.64 7TH TSP Bobbin 11 92 NQI 0.86 3 147 6TH TSP
+31.59 F/L Bobbin ODI 4
0.93 3 144 4TH TSP
+20.62 F/L Bobbin 11 99 ADI 3.24 6 50 STH TSP
+32.22 F/L Bobbin ODI 22 0.47 3 126 12TH TSP
+39.16 F/L C/L Special I VOL 0.72 1 107 11TH TSP
-4.87 11TH TSP Bobbin 12 40 NOI 1.29 3 98 11TH TSP
+28.60 F/L C/L Special I VOL 2.35 1 127 10TH TSP
-15.56 10TH TSP Bobbin 12 45 ODI 23 1.18 3 123 7TH TSP
+22.44 F/L H/L Special I VOL 0.46 1 116 BTH TSP
-20.56 8TH TSP H/L Special I VOL 0.48 1 121 BTH TSP
-22.43 8TH TSP Bobbin 12 48 ODI 21 0.85 3 125 4TH TSP
+8.75 F/L H/L Special I VOL 0.66 1 114 4TH TSP
+8.33 4TH TSP Bobbin 12 56 NOI 0.48 3 86 13TH TSP
+18.46 F/L Bobbin 12 58 NQI 0.49 3 117 18TH TSP
+8.05 F/L C/L Special I VOL 0.10 1 101 1BTH TSP
+8.63 18TH TSP Bobbin 12 74 ADI 2.75 6 74 11TH TSP
+31.82 F/L C/L Special I VOL 0.18 1 104 11TH TSP
+30.91 10TH TSP Bobbin 12 75 IDI 64 11.98 P 1 88 TE-HL
+9.26 F/L H/L Special I MAI 6.70 1 26 TE-HL
+ 8. 0 ?.
TTS-HL Bobbin 12 96 ODI 11 0.51 P 1 139 3RD TSP
+0.28 F/L H/L Tubesheet 12 104 MAI 0.31 1 53 TTS-HL
-2.86 TTS-H7.
Bobbin 12 106 NQI 0.43 P 1 97 2ND TSP
-0.15 F/L l
H/L Special I SAI 0.47 P 1 168 2ND TSP
-0.03 2ND TSP 1
Bobbin 12 112 IDI 48 20.54 P 1 106 TE-HL
+15.75 F/L H/L Special I MAI 6.88 1 21 TE-HL
+15.50 TTS-HL Bobbin 13 38 NQI 1.86 P 1 126 TE-HL
+12.19 F/L Bobbin 13 44 NOI 0.50 3 43 4TH TSP
+36.66 F/L Bobbin 13 53 NOI 0.79 3 109 18TH TSP
+0.06 F/L C/L Special I VOL 0.54 1 90 18TH TSP
+8.82 18TH TSP Bobbin 13 62 NOI 0.33 P 1 48 2ND TSP
-0.03 F/L H/L Special I SAI 0.28 1 59 2ND TSP
-0.08 2ND TSP Bobbin 13 67 ADI 6.54 6 70 4TH TSP
+15.49 F/L H/L Special I VOL 1.38 1 122 4TH TSP
+14.28 4TH TSP Bobbin 13 96 IDI 61 10.27 P 1 92 TE-HL
+6.32 F/L Bobbin IDI 71 24.33 P 1 80 TE-HL
+9.04 F/L H/L Tubesheet SAI 0.71 1 37 TTS-HL
+0.00 TTS-HL Bobbin 14 5 ODI 55 0.76 3 96 13TH TSP
+9.72 F/L C/L Special I VOL 0.23 1 111 13TH TSP
+8.88 13TH TSP Bobbin 14 14 ADI 3.96 6 68 12TH TSP
+30.90 F/L Bobbin ADI 4.46 6 68 20TH TSP
+4.36 F/L Bobbin IDI 42 7.16 P 1 18 TE-HL
+18.40 F/L C/L Special I VOL 0.70 1 96 11TH TSP
-13.18 11TH TSP C/L Special I VOL 0.84 1 90 20TH TSP
+3.79 19TH TSP Bobbin 14 20 NOI 0.55 P 1 47 4TH TSP
-0.03 F/L H/L Special I SAI 0.28 1 12 4TH TSP
-0.13 4TH TSP Bobbin 14 34 ADI 7.27 6 84 11TH TSP
+5.95 F/L C/L Special I VOL 0.68 1 62 11TH TSP
+5.43 11TH TSP Bobbin 14 35 NQI 0.50 3 49 16TH TSP
+0.99 F/L Bobbin 14 41 ADI 6.11 6 97 STH TSP
+17.85 F/L H/L Special I VOL 0.79 1 90 6TH TSP
-26.35 6TH TSP Bobbin 14 44 IDI 40 11.25 P 1 165 TE-HL
+16.58 F/L Bobbin 14 46 ADI 5.53 6 79 17TH TSP
+7.08 F/L C/L Special I VOL 0.77 1 118 17TH TSP
+6.49 16TH TSP Bobbin 14 66 NQI 0.56 3 86 17TH TSP
-4.23 F/L
.cocococo BWNT TUBAN II (Varzion 2.1) 07/13/1995 13:43:23 cocooo**
McGuire Nuclotr Station - Unit Two coco ****
S/G B L
ococoe**
12/94 RFO 000*****
Bobbin,C/L Special Interest,H/L Special Interest,H/L Tubesheet,U-Bend Page 5 of 13 ATTACHMENT #2 - INDICATIONS OF IMPERFECTIONS INDS OF IMPERFECTIONS - SGB TEST TYPE ROW COL IND %TW VOLTS CIDI DEG LOCATION EXTENT 1 H/L Tubesheet 14 104 SAI 0.74 1 20 TTS-HL
-1.11 TTS-HL H/L Tubesheet 14 107 SAI 2.18 2 27 TTS-HL
-0.06 TTS-HL.
Bobbin 15 11 NQI 0.81 3 39 TTS-HL
+2.28 F/L Bobbin 15 27 ADI 4.10 6 104 6TH TSP
+9.86 F/L H/L Special I VOL 1.02 1 119 6TH TSP
+10.62 6TH TSP Bobbin 15-39 ADI 2.38 6 101 22ND TSP
+13.73 F/L Bobbin NQI 10.84 P1 23 TE-CL
+8.88 F/L Bobbin 15 44 ADI 2.06 6 143 3RD TSP
+27.88 F/L Bobbin 15 52 ADI 5.36 6 102 11TH TSP
+16.41 F/L C/L Special I VOL 0.78 1 66 11TH TSP
+16.42 11TH TSP Bobbin 15 54 ADI 7.38 6 67 3RD TSP
+8.98 F/L H/L Special I VOL 1.21 1 154 3RD TSP
+9.62 3RD TSP Bobbin 15 64 IDI 84 12.82 P 1 31 TE-HL
+18.26 F/L H/L Tubesheet MAI 2.39 1 33 TTS-HL
-3.48 TTS-HL H/L Special I MAI 2.26 1 30 TTS-HL
-2.23 TTS-HL Bobbin 15 73 ODI 10 0.56 P 1 141 3RD TSP
+0.16 F/L i
H/L Special I SAI 0.20 1 39 3RD TSP
-0.02 3RD TSP Bobbin 15 76 ODI 6
1.81 3 148 6TH TSP
+29.78 F/L H/L Special I VOL 0.65 1 94 7TH TSP
-11.41 7TH TSP H/L Special I VOL 0.74 1 101 7TH TSP
-10.10 7TH TSP H/L Special I VOL 1.29 1 106 7TH TSP
-13.13 7TH TSP Bobbin 15 79 ODI 23 0.41 3 129 STH TSP
+9.90 F/L Bobbin 15 102 NOI 1.03 3 103 15TH TSP
+3.61 F/L C/L Special I VOL 0.82 1 116 15TH TSP
+3.57 14TH TSP Bobbin 15 105 ODI 18 1.65 3 134 4TH TSP
+22.32 F/L H/L Special I VOL 0.60 1 67 4TH TSP
+22.34 4TH TSP Bobbin 15 110 NQI 0.41 P 1 107 3RD TSP
-0.19 F/L Bobbin 16 9 NQI 0.75 3 102 7TH TSP
+6.31 F/L H/L Special I VOL 0.80 1 145 7TH TSP
+6.47 7TH TSP Bobbin 16 12 ADI 2.80 6 51 12TH TSP
+10.06 F/L C/L Special I VOL 0.19 1 81 12TH TSP
+8.97 12TH TSP C/L Special I VOL 0.41 1 76 12TH TSP
+2.97 12TH TSP Bobbin 16 13 ADI 3.24 6 89 15TH TSP
+7.04 F/L Bobbin NQI 0.50 3 61 13TH TSP
+5.61 F/L C/L Special I VOL 0.28 1 99 15TH TSP
+6.36 14TH TSP C/L Special I VOL 0.36 1 46 13TH TSP
+5.42 13TH TSP Bobbin 16 14 NQI 0.81 3 123 13TH TSP
+2.83 F/L Bobbin 16 17 ADI 3.77 6
.74 TTS-CL
+5.09 F/L Bobbin ODI 31 2.52 4 138 22ND TSP
+7.72 F/L Bobbin NQI 6.26 P 1 24 TE-CL
+4.24 F/L Bobbin 16 23 NQI 0.32 3 104 10TH TSP
+34.40 F/L C/L Special I VOL 0.62 1 128 9TH TSP
-9.93 9TH TSP Bobbin 16 38 NOI 1.57 3 97 16TH TSP
+1.50 F/L Bobbin 16 51 NQI 1.33 3 133 12TH TSP
+20.13 F/L Bobbin 16 57 IDI 42 8.82 P 1 14 TE-HL
+4.87 F/L Bobbin 16 59 IDI 68 17.32 P 1 25 TE-HL
+8.94 F/L H/L Special I MAI 1.38 1 19 TTS-HL
-11.57 TTS-HL H/L Special I MAI 6.46 1 26 TTS-HL
-18.34 TTS-HL Bobbin 16 76 IDI 70 11.35 P 1 26 TE-HL
+6.69 F/L 3.77 1 19 TE-HL
+6.03 TTS-HL I
H/L Special I SAI
.67 10.35 P 1 22 TE-HL
+3.01 F/L Bobbin 16 97 IDI H/L Special I MAI 3.08 1 16 TE-HL
+2.56 TTS-HL Bobbin 17 11 ADI 7.83 6 87 STH TSP-
+30.92 F/L i
H/L Special I VOL 1.89 1 104 6TH TSP
-12.95 6TH TSP Bobbin 17 14 NQI 0.50 3 123 12TH TSP
+26.71 F/L C/L Special I SAI 0.11 1 117 12TH TSP
+26.85 12TH TSP Bobbin 17 28 NQI 0.56 3 77 STH TSP
+18,24 F/L H/L Special I NQI 0.40 1 40 5TH TSP
+18.13 STH TSP Bobbin 17 45 NQI 4.31 P 1 23 TE-HL
+7.85 F/L Bobbin 17 50 ODI 26 0.61 3 122 19TH TSP
+3.40 F/L Bobbin IDI 89 2.63 P 1 49 TE-HL
+5.70 F/L C/L Special I SAI 0.18 1 119 19TH TSP
+3.40 18TH TSP C/L Special I VOL 0.15 P 1 28 18TH TSP
+0.04 18TH TSP Bobbin 17 61 IDI 24 16.58 P 1 6 TE-HL
+10.14 F/L H/L Special I MAI 0.34 1 33 TE-HL
+9.97 TTS-HL
BWNT TUBAN II (Version 2.1) 07/13/1995 13:43:23 McGuire Nuclear Station - U it Two n
S/G B 12/94 RFO Bobbin,C/L Special Interest,H/L Special Interest,H/L Tubesheet,U-Bend ATTACHMENT #2 - INDICATIONS OF IMPERFECTIONS INDS OF IMPERFECTIONS - SGB TEST TYPE ROW COL IND %TW VOLTS CHN DEG LOCATION EXTENT 1 H/L Special I MAI 3.74 1 42 TE-HL
+6.39 TTS-HL Bobbin 17 74 IDI 78 6.08 P 1 56 TE-HL
+16.98 F/L H/L Tubesheet 17 79 SCI 0.78 1 20 TTS-HL
-0.28 TTS-HL Bobbin 17 109 IDI 21 6.01 P 1 126 TE-HL
+13.93 F/L H/L Special I SAI 4.27 1 27 TTS-HL
-6.80 TTS-HL Bobbin 18 8 NQI 0.68 3 122 12TH TSP
-1.44 F/L C/L Special I VOL 0.54 1 110 12TH TSP
-1.71 12TH TSP Bobbin 18 13 NOI 0.46 3 52 2ND TSP
+f.24 F/L Bobbin 18 14 NQI 0.52 3 94 18TH TSP
+1.31 F/L C/L Special I VOL 0.49 1 104 18TH TSP
+1.53 18TH TSP C/L Special I VOL 0.15 P 1 113 18TH TSP
+0.13 18TH TSP Bobbin 18 18 NQI 0.34 3 57 11TH TSP
+16.05 F/L C/L Special I VOL 0.62 1 123 11TH TSP
+16.06 11TH TSP 0.38 P 1 66 4TH TSP
+0.03 F/L Bobbin 18 69 NQI H/L Special I SAI 0.60 1 61 4TH TSP
+0.00 4TH TSP Bobbin 18 71 IDI 48 11.74 P1 12 TE-HL
+17.33 F/L H/L Tubesheet MAI 7.66 1 32 TTS-HL
-4.51 TTS-HL Bobbin 18 103 IDI 79 21.66 P 1 55 TE-HL
+18.06 F/L H/L Tubesheet MAI 9.78 1 30 TTS-HL
-3.72 TTS-HL H/L Special I MAI 11.44 1 24 TE-HL
+17.28 TTS-HL Bobbin 19 6 ADI 7.67 6 59 6TH TSP
+38.64 F/L Bobbin ADI 3.03 6 59 13TH TSP
+14.75 F/L Bobbin ADI 4.83 6 65 12TH TSP
+21.06 F/L I
Bobbin ADI 6.09 6 68 12TH TSP
+3.94 F/L Bobbin NOI 0.45 3 35 12TH TSP
+14.41 F/L H/L Special I VOL 1.62 1 123 7TH TSP
-5.79 7TH TSP C/L Special I VOL 0.35 1 106 12TH TSP
-6.18 12TH TSP C/L Special I VOL 0.38 1 121 12TH TSP
+13.05 12TH TSP C/L Special I VOL 0.41 1 107 12TH TSP
+11.34 12TH TSP C/L Special I VOL 0.64 1 112 12TH TSP
+19.83 12TH TSP C/L Special I VOL 0.66 1 113 12TH TSP
+24.18 12TH TSP C/L Special I VOL 0.71 1 113 12TH TSP
+14.23 12TH TSP C/L Special I VOL 0.84 1 93 12TH TSP
+3.41 12TH TSP C/L Special I VOL 0.85 1 103 12TH TSP
+3.85 12TH TSP C/L Special I VOL 0.90 1 113 12TH TSP
+23.12 12TH TSP C/L Special I VOL 1.18 1 101 12TH TSP
+21.51 12TH TSP
]
C/L Special I VOL 1.69 1 95 12TH TSP
+5.98 12TH TSP Bobbin 19 8 ODI 23 0.50 3 126 11TH TSP
+1.57 F/L C/L Special I VOL 0.71 1 148 11TH TSP
+1.57 11TH TSP Bobbin 19 10 ADI 3.74 6 68 4TH TSP
+35.80 F/L H/L Special I VOL 0.64 1 86 STH TSP
-7.97 STH TSP Bobbin 19 12 NOI 2.98 P 1 64 TE-HL
+14.62 F/L Bobbin 19 15 ADI 1.81 6 63 13TH TSP
+15.31 F/L C/L Special I VOL 0.37 1 121 12TH TSP
-7.02 12TH TSP Bobbin 19 23 NOI 2.66 P 1 93 TE-HL
+11.19 F/L Bobbin 19 28 ADI 2.93 6 48 22ND TSP
+5.10 F/L C/L Special I VOL 0.57 1 99 22ND TSP
+4.81 22ND TSP Bobbin 19 33 NQI 7.33 P 1 19 TE-HL
+19.32 F/L Bobbin 19 46 ADI 4.69 6 70 10TH TSP
+17.08 F/L 4
C/L Special I VOL 0.44 1 130 10TH TSP
+16.90 10TH TSP Bobbin 19 50 NQI 0.75 3 141 14TH TSP
+1.88 F/L j
C/L Special I VOL 0.34'1 85 14TH TSP
+1.96 14TH TSP Bobbin 19 70 NOI 0.58 3 151 11TH TSP
+21.69 F/L Bobbin ODI 14 0.28 3 135 11TH TSP
+21.40 F/L H/L Tubesheet 19 74 MAI 0.87 1 42 TTS-HL
-0.02 TTS-HL Bobbin 20 28 ADI 2.64 6 66 11TH TSP
+8.63 F/L C/L Special I VOL 0.65 1 111 11TH TSP
+8.27 11TH TSP Bobbin 20 30 ADI 2.56 6 71 11TH TSP
+39.64 F/L Bobbin ADI 3.71 6 59 11TH TSP
+41.42 F/L j
C/L Special I VOL 0.58 1 151 10TH TSP
-3.06 10Th TSP j
Bobbin 20 48 ADI 2.42 6 71 12TH TSP
+34.74 F/L Bobbin 20 60 ODI 8
4.37 4 145 STH TSP
+17.67 F/L H/L Special I VOL 0.83 1 106 STH TSP
+16.60 STH TSP H/L Tubesheet 20 64 SAI 0.67 1 16 TTS-HL
-0.02 TTS-HL Bobbin 20 75 IDI 96 37.10 P 1 39 TE-HL
+2.23 F/L
i BWNT TUBAN II (Version 2.1) 07/13/1995 13:43:23 l
- ~
McGuire Nuclear Station - Unit Two
{
S/G B
- e*****
12/94 RFO
]
Bobbin,C/L Special Interest,H/L Special Interest,H/L Tubesheet,U-Bend Page 7 of 13 ATTACHMENT #2 - INDICATIONS OF IMPERFECTIONS INDS OF IMPERFECTIONS - SGB TEST TYPE ROW COL IND %TW VOLTS CHN DEG LOCATION EXTENT 1 r
H/L Special I MAI 11.23 1 29 TE-HL
+2.27 TTS-HL Bobbin 20 81 IDI 50 4.29 P 1 97 TE-HL
+13.67 F/L H/L Special I MAI 3 67 1 22 TE-HL
+13.54 TTS-HL Bobbin 20 83 NOI 0.57 P 1 122 STH TSP
-0.35 F/L Bobbin 20 95 IDI 61 27.98 P 1 20 TE-HL
+7.01 F/L
- H/L Special I MAI 6.37 1 28 TE-HL
+7.13 TTS-HL Bobbin 20 97 ODI 21 0.28 P 1 124 3RD TSP
-0.14-F/L Bobbin 21 6 ODI 5
1.11 3 144 19TH TSP
+1.36 F/L C/L Special I VOL 0.20 1 90 19TH TSP
+1.57 19T9 TSP Bobbin 21 7 NOI 0.43 3 100 18TH TSP
+19.13 Fu C/L Special I VOL 0.17 1 100 17TH TSP
-3.24 17TH TSP Bobbin 21 52 IDI 93 21.37 P 1 41 TE-HL
+2.55 F/L Bobbin 21 74 IDI 81 31.58 P 1 30 TE-HL
+16.26 F/L H/L Special I MAI 3.00 1 23 TE-HL
+14.95 TTS-HL Bobbin 22 86 WAR 12 1.06 P 4 0 3AVB
+0.00 F/L H/L Tubesheet 22 87 SAI 1.05 1 18 TTS-HL
-0.03 TTS-HL Bobbin 23 16 ADI 2.81 6 57 11TH TSP
+34.17 F/L C/L Special I VOL 0.48 1 118 10TH TSP
-10.43 10TH TSP Bobbin 23 17 ADI 2.68 6 101 11TH TSP
+18.42 F/L C/L Special I VOL 0.48 1 67 11TH TSP
+17.60 11TH TSP Bobbin 23 38 ADI 2.03 6 SO 17TH T6P
+6.65 F/L C/L Special I VOL 0.99 1 106 17TH TSP
+6.36 17TH TSP Bobbin 23 57 NOI 0.50 3 78 11TH TSP
+35.12 F/L C/L Special I VOL 0.67 1 96 10TH TSP
-8.84 10TH TSP Bobbin 23 58 WAR 8
1.11 P 4 129 3AVB
+0.00 F/L H/L Tubesheet 23 69 SAI 0.41 1 73 TTS-HL
-0.10 TTS-HL H/L Tubesheet SCI 1.14 1 25 TTS-HL
-0.07 TTS-HL Bobbin 23 88 ODI 31 0.67 3 118 3RD TSP
+9.84 F/L H/L Special I VOL 0.40 1 42 3RD TSP
+9.38 3RD TSP Bobbin 23 92 IDI 78 26.10 P 1 29 TE-HL
+12.70 F/L H/L Special I MAI 3.46 1 17 TE-HL
+11.86 TTS-HL Bobbin 24 15 ODI 4
1.14 3 141 11TH TSP
+25.13 F/L C/L Special I VOL 0.42 1 110 10TH TSP
-19.05 10TH TSP Bobbin 24 18 ODI 3
0.68 3 142 10TH TSP
+32.43 F/L C/L Special I VOL 0.18 1 149 9TH TSP
-11.32 9TH TSP Bobbin 24 53 ADI 4.74 6 104 6TH TSP
+11.07 F/L H/L Special I VOL 1.38 1 130 6TH TSP
+11.57 6TH TSP Bobbin 24 81 IDI 72 10.34 P 1 64 TE-HL
+9.57 F/L H/L Special I MAI 5.41 1 42 TE-HL
+8.85 TTS-HL Bobbin 25 10 NOI 0.43 3 109 6TH TSP
+9.09 F/L H/L Special I VOL 0.74 1 163 6TH TSP
+8.92 6TH TSP Bobbin 25 20 NQI 30.18 P 1 2 TTS-HL
+0.08 F/L Bobbin 25 44 ADI 4.52 6 92 11TH TSP
+11.90 F/L C/L Special I VOL 0.98 1 109 11TH TSP
+11.60 11TH TSP Bobbin 25 47 ADI 1.77 6 82 7TH TSP
+34.13 F/L Bobbin ADI 4.51 6 81 7TH TSP
+26.82 F/L H/L Special I VOL 0.23 1 80 8TH TSP
-9.88 8TH TSP H/L Special I VOL 1.07 1 132 8TH TSP
-17.37 8TH TSP Bobbin 25 48 ODI 13 0.50 3 134 TTS-CL
+4.95 F/L Bobbin 25 63 NQI 0.45 3 52 2ND TSP
+10.90 F/L Bobbin ODI 18 1.82 4 133 TTS-HL-
+17.36 F/L Bobbin ODI 4
1.20 3 142 2ND TSP
+3.11 F/L H/L Special I VOL 0.65 1 94 TTS-HL
+16.54 2ND TSP H/L Special I VOL 0.92 1 109 2ND TSP
+2.69 2ND TSP H/L Tubesheet 25 85 SAI 1.27 1 27 TTS-HL
+0.06 TTS-HL Bobbin 25 106 ODI 4
1.22 3 142 7TH TSP
+10.22 F/L i
H/L Special I VOL 0.89 1 91 7TH TSP
+9.80 7TH TSP Bobbin 26 9 ADI 4.87 6 86 6TH TSP
+32.73 F/L H/L Special I VOL 0.38 1 129 7TH TSP
-12.12 7TH TSP Bobbin 26 27 NQI 2.16 P 1 158 TE-HL
+15.39 F/L Bobbin 26 30 NOI 1.90 P 1 29 TTS-HL
-1.16 F/L Bobbin 26 35 NQI 3.19 P 1 18 TE-HL
+10.02 F/L Bobbin 26 55 ODI 10 1.99 4 130 21ST TSP
+3.85 F/L C/L Special I VOL 0.27 1 56 21ST TSP
+3.67 20TH TSP Bobbin 26 65 ODI 7
1.11 3 140 3RD TSP
+15.78 F/L
I BWNT.TUBAN II (Version 2.1) 07/13/1995 13:43:23 McGuire Nuclear Station - Unit Two S/G B 12/94 RFO Bobbin,C/L Special Interest,H/L Special Interest,H/L Tubesheet,U-Bend Page 8 of 13 ATTACHMENT #2 - INDICATIONS OF IMPERFECTIONS INDS OF IMPERFECTIONS - SGB TEST TYPE ROW COL IND %TW VOLTS CHN DEG LOCATION EXTENT 1 H/L Special I VOL 1.38 1 141 3RD TSP
+14.73 3RD TSP H/L Special I VOL 1.43 1 164 3RD TSP
+3.13 3RD TSP Bobbin 26 74 WAR 14 0.97 P 4 0 2AVB
+0.00 F/L Bobbin 26 85 ODI 30 1.43 3 119 7TH TSP
+16.80 F/L H/L Special I VOL 1.67 1 112 7TH TSP
+16.16 7TH TSP Bobbin 26 87 NOI 0.55 3 99 3RD TSP
+14.14 F/L Bobbin 27 30 ODI 9
1.53 3 141 18TH TSP
+18.06 F/L C/L Special I VOL 0.59 1 118 17TH TSP
-4.03 17TH TSP Bobbin 27 60 ODI 16 4.02 6 77 3RD TSP
+15.17 F/L Bobbin 27 69 IDI 89 8.83 P 1 34 TE-HL
+7.75 F/L Bobbin IDI 92 10.70 P 1 35 TE-HL
+8.77 F/L H/L Special I MAI 0.51 1 21 TE-HL
+7.45 TTS-HL H/L Special I MAI 2.90 1 25 TE-HL
+8.34 TTS-HL Bobbin 27 74 NQI 0.62 3 74 19TH TSP
-1.44 F/L C/L Special I VOL 0.68 1 110 19TH TSP
-1.50 19TH TSP Bobbin 27 96 NQI 1.93 P 1 29 TE-HL
+4.88 F/L Bobbin 27 101 IDI 70 12.02 P 1 19 TE-HL
+15.70 F/L H/L Special I MAI 3.40 1 17 TTS-HL
-5.63 TTS-HL Bobbin 28 32 ODI 23 3.40 4 119 22ND TSP
+17.02 F/L C/L Special I VOL 1.05 1 120 21ST TSP
-3.59 21ST TSP Bobbin 28 49 ODI B
1.34 3 142 20TH TSP
+5.86 F/L C/L Special I VOL 0.82 1 114 20TH TSP
+6.63 19TH TSP Bobbin 28 56 ADI 3.47 6 71 2ND TSP
+4.74 F/L H/L Special I VOL 0.88 1 107 2ND TSP
+5.36 2ND TSP H/L Tubesheet 28 59 SAI 1.18 1 36 TTS-HL
-2.98 TTS-HL Bobbin 28 93 IDI 51 11.01 P 1 19 TE-HL
+8.31 F/L H/L Special I SAI 0.71 1 41 TTS-HL
-12.27 TTS-HL Bobbin 28 96 NOI 0.35 P 1 131 3RD TSP
+0.00 F/L Bobbin 28 99 NOI 7.07 P 1 19 TTS-HL
-1.01 F/L Bobbin 28 100 NOI 20.72 P 1 9 TE-HL
+13.68 F/L i
H/L Special I MAI 1.03 1 41 TTS-HL
-7.38 TTS-HL Bobbin 28 104 IDI 32 14.56 P 1 12 TE-HL
+18.07 F/L Bobbin 29 30 ODI 24 1.26 3 126 TTS-CL
+3.33 F/L C/L Special I VOL 1.04 1 106 TTS-CL
+3.36 22ND TSP Bobbin 29 49 NQI 6.16 3 20 9TH TSP
+7.26 F/L U-Bend SAI 6.03 1 6 9TH TSP
+8.44 9TH TSP Bobbin 29 92 IDI 48 21.50 P 1 16 TE-HL
+14.66 F/L i
H/L Special I MAI 2,07 1 195 TTS-HL
-6.46 TTS-HL j
Bobbin 29 96 IDI 43 8.48 P 1 16 TE-HL
+3.01 F/L Bobbin 30 13 WAR 15 0.89 P 4 0 1AVB
+0.00 F/L Bobbin 30 27 ADI 3.62 6 40 10TH TSP
+18.36 F/L C/L Special I VOL 1.12 1 51 10TH TSP
+19.20 10TH TSP Bobbin 30 45 ODI 12 1.96 4 131 ISTH TSP
+5.38 F/L C/L Special I VOL 0.65 1 128 15TH TSP
+5.42 14TH TSP Bobbin 30 54 NOI 0.31 3 121 10TH TSP
+29.45 F/L C/L Special I VOL 0.15 1 159 9TH TSP
-15.19 9TH TSP Bobbin 30 57 ADI 3.11 6 68 7TH TSP
+6.66 F/L Bobbin ADI 3.41 6 66 6TH TSP
+36.18 F/L H/L Special I VOL 1.00 1 107 7TH TSP
-7.40 7TH TSP H/L Special I VOL 1.23 1 116 7TH TSP
+6.77 7TH TSP Bobbin 30 77 IDI 77 14.85 P 1 66 TE-HL
+13.46 F/L H/L Special I MAI 10.41 1 29 TE-HL
+12.73 TTS-HL H/L Special I SAI 4.36 1 32 TE-HL
+10.89 TTS-HL Bobbin 30 78 IDI 88 42.31 P 1 51 TE-HL
+13.22 F/L H/L Special I MAI 9.15 1 26 TE-HL
+12.13 TTS-HL H/L Tubesheet 30 90 VOL 0.53 1 60 TTS-HL
-1.10 TTS-HL Bobbin 31 15 ODI 20 0.62 P 4 90 2AVB
+0.00 F/L U-Bend VOL 0.60 P 1 163 2AVB
+0.00 3AVB Bobbin 31 22 NOI 0.31 3 111 3RD TSP
+12.13 F/L H/L Special I VOL 0.20 1 143 3RD TSP
+11.99 3RD TSP Bobbin 31 37 ADI 8.86 6 68 TTS-HL
+6.30 F/L H/L Special I VOL 1.46 1 127 TTS-HL
+5.64 TTS-HL Bobbin 31 102 NOI 0.78 3 45 19TH TSP
+1.37 F/L C/L Special I VOL 0.29 1 127 19TH TSP
+1.51 18TH TSP Bobbin 32 14 NOI 0.54 3 86 12TH TSP
+36.20 F/L 1
BWNT TUBAN II (Version 2.1) 07/13/1995 13:43:23 McGuire Nuclear Station - Unit Two S/G B 12/94 RFO Bobbin,C/L Special Interest,H/L Special Interest,H/L Tubesheet,U-Bend Page 9 of 13 ATTACHMENT #2 - INDICATIONS OF IMPERFECTIONS INDS OF IMPERFECTIONS - SGB TEST TYPE ROW COL IND %TW VOLTS CHN DEG LOCATION EXTENT 1 C/L Special I VOL 0.70 1 95 11TH TSP
-0.03 11TH TSP Bobbin 32 43 ODI 8
1.99 4 134 3RD TSP
+24.49 F/L H/L Special I VOL 0.63 1 108 3RD TSP
+25.52 3RD TSP Dobbin 32 56 ODI 30 0.83 3 117 IST TSP
+2.67 F/L Bobbin NOI 0.28 P1 58 IST TSP
+0.72 F/L H/L Special I VOL 0.31 1 141 IST TSP
+0.66 IST TSP H/L Special I VOL 0.66 1 129 IST TSP
+2.78 IST TSP H/L Tubesheet 32 58 SAI 2.04 1 25 TTS-HL
-0.06 TTS-HL Bobbin 32 66 ADI 4.34 6 66 6TH TSP
+15.62 F/L Bobbin ADI 16.64 6 67 18TH TSP
+6.37 F/L H/L Special I VOL 0.85 1 128 6TH TSP
+14.90 6TH TSP C/L Special I VOL 1.39 1 97 18TH TSP
+6.24 18TH TSP Bobbin 32 67 NQI 0.77 3 104 6TH TSP
+1.30 F/L H/L Special I VOL 0.84 1 140 6TH TSP
+1.04 6TH TSP Bobbin 32 70 ADI 6.21 6 92 4TH TSP
+5.38 F/L H/L Special I VOL 1.13 1 133 4TH TSP
+5.53 4TH TSP H/L Tubesheet 32 98 SAI 1.22 1 10 TTS-HL
-0.12 TTS-HL Bobbin 33 30 NQI 0.76 3 53 10TH TSP
+36.90 F/L Bobbin 33 40 NQI 6.45 3 18 22ND TSP
+17.30 F/L Bobbin 33 47 NQI 0.24 3 107 6TH TSP
+32.32 F/L Bobbin NQI 0.29 3 118 7TH TSP
+13.57 F/L H/L Special I NOI 0.21 1 45 7TH TSP
+13.72 7TH TSP H/L Special I VOL 0.18 1 63 6TH TSP
+32.67 7TH TSP Bobbin 33 67 ODI 6
0.91 3 140 19TH TSP
-1.40 F/L C/L Special I VOL 0.20 1 125 19TH TSP
-1.30 19TH TSP Bobbin 34 32 ADI 1.99 6 77 TTS-CL
+3.02 F/L Bobbin 34 55 ODI 2
1.80 3 144 16TH TSP
+6.91 F/L C/L Special I VOL 0.70 1 113 15TH TSP
-4.07 ISTH TSP Bobbin 34 68 ODI 13 0.67 3 134 3RD TSP
+28.71 F/L H/L Special I VOL 0.24 1 133 4TH TSP
-14.19 4TH TSP Bobbin 34 72 ADI 4.42 6 119 4AVB
-7.67 F/L U-Bend VOL 2.58 3 116 4AVB
-9.25 4AVB Bobbin 34 76 NOI 0.50 3 111 2ND TSP
+19.94 F/L Bobbin 34 80 IDI 73 10.57 P 1 22 TE-HL
+7.26 F/L Bobbin IDI 94 42.05 P 1 39 TE-HL
+9.04 F/L Bobbin 35 32 NOI 1.03 3 128 4AVB
-17.66 F/L U-Bend VOL 2.51 1 150 4AVB
-17.37 9TH TSP Bobbin 35 38 ODI 12 0.68 3 135 14TH TSP
+2.48 F/L C/L Special I VOL 0.26 1 115 14TH TSP
+2.61 14TH TSP C/L Special I VOL 0,44 1 108 14TH TSP
+4.80 14TH TSP Bobbin 35 39 ODI 9
1.68 3 138 6TH TSP
+36.03 F/L H/L Special I VOL 1.10 1 116 7TH TSP
-8.07 7TH TSP Bobbin 35 44 WAR 10 0.60 P 4 0 1AVB
+0.00 F/L Bobbin 35 60 ODI 9
1.14 4 131 STH TSP
+12.46 F/L H/L Special I VOL 0.77 1 125 STH TSP
+12.12 STH TSP Bobbin 35 85 ODI 18 0.67 3 130 7TH TSP
+8.29 F/L Bobbin ODI 21 1.20 3 127 7TH TSP
+4.17 F/L H/L Special I VOL 1.22 1 78 7TH TSP
+8.21 7TH TSP H/L Special I VOL 1,64 1 106 7TH TSP
+4.06 7TH TSP Bobbin 36 22 ODI 2
1.27 3 144 18TH TSP
+6.03 F/L C/L Special I VOL 0.58 1 92 18TH TSP
+6.58 18TH TSP Bobbin 36 25 NOI 2.73 P 1 59 TE-HL
+17.44 F/L Bobbin 36 59 WAR 20 1.23 P 4 0 2AVB
+0.00 F/L Bobbin WAR 24 1.62 P 4 0 3AVB
+0.00 F/L Bobbin 36 60 WAR 17 1.03 P 4 0 2AVB
+0.00 F/L Bobbin WAR 29 2.17 P 4 0 1AVB
+0.00 F/L Bobbin 36 65 WAR 18 1.09 P 4 0 1AVB
+0.00 F/L H/L Tubesheet 36 75 SAI 0.96 1 21 TTS-HL
+0.00 TTS-HL Bobbin 36 83 ODI 7
1.95 4 140 10TH TSP
+5.60 F/L Bobbin ODI 10 1.02 4 138 10TH TSP
+14.37 F/L Bobbin ODI 19 1.28 3 131 11TH TSP
+16.75 F/L Bobbin ODI 29 1.39 4 122 10TH TSP
+20.00 F/L C/L Special I VOL 0.50 1 113 10TH TSP
+13.92 10TH TSP C/L Special I VOL 0.53 1 90 10TH TSP
+20.19 10TH TSP C/L Special I VOL 0.55 1 92 10TH TSP
+5.22 10TH TSP
BWNT 7UBAN II (Varsion 2.1) 07/13/1995 13:43:23 4*******
McGuire Nuclear Station - Unit Two S/G B 12/94 RFO Bobbin,C/L Special Interest,H/L Special Interest,H/L Tubesheet,U-Bend ATTACHMENT #2 - INDICATIONS OF IMPERFECTIONS INDS OF IMPERFECTIONS - SGB TEST TYPE ROW COL IND %TW VOLTS CHN DEG LOCATION EXTENT 1 I
C/L Special I VOL 0.73 1 91 11TH TSP
+16.73 11TH TSP I
Bobbin 36 85 NOI 0.45 3 102 2ND TSP
+19.05 F/L I
Bobbin 36 92 IDI 68 9.01 P 1 19 TE-HL
+8.92 F/L H/L Special I MAI 3.18 1 27 TE-HL
+9.10 TTS-HL Eobbin 36 94 ODI 16 3.25 4 132 12TH TSP
+27.78 F/L C/L Special I VOL 0.94 1 79 12TH TSP
+26.88 12TH TSP I
Bobbin 37 17 WAR 13 0.86 P 4 0 3AVB
+0.00 F/L Bobbin 37 19 ODI 6
2.25 3 139 12TH TSP
+10.07 F/L l
C/L Special I VOL 1.55 1 114 12TH TSP
+10.23 12TH TSP Bobbin 37 50 NQI 1.15 3 117 2ND TSP
+16.11 F/L i
H/L Special I VOL 0.53 1 116 2ND TSP
+16.54 3RD TSP Bobbin 37 67 ODI 15 1.05 4 134 4TH TSP
+20.74 F/L H/L Special I VOL 0.62 1 145 4TH TSP
+19.82 4TH TSP Bobbin 37 70 ODI 3
0.89 3 147 STH TSP
+6.44 F/L Bobbin ODI 13 0.92 3 137 STH TSP
+7.79 F/L H/L Special I VOL 0.84 1 150 STH TSP
+4.63 STH TSP H/L Special I VOL 0.90 1 137 STH TSP
+7.17 STH TSP H/L Special I VOL 1.00 1 145 STH TSP
+5.95 STH TSP Bobbin 37 80 ODI 17 0.77 3 131 1ST TSP
+5.05 F/L Bobbin 37 81 ODI 21 0.68 3 127 4TH TSP
+19.85 F/L H/L Special I VOL 2.24 1 148 4TH TSP
+1S.53 4TH TSP Bobbin 37 85 ADI 5.52 6 81 STH TSP
+14.76 F/L j
H/L Special I VOL 1.40 1 113 STH TSP
+14.69 STH TSP Bobbin 37 97 NQI 6.48 3 177 8TH TSP
+19.79 F/L U-Bend VOL 0.87 1 134 8TH TSP
+20.03 8TH TSP Bobbin 38 36 WAR 14 0.94 P 4 0 2AVB
+0.00 F/L Bobbin 38 42 NOI 0.43 3 114 TTS-CL
+1.95 F/L Bobbin 38 43 NQI 0.37 3 105 13TH TSP
+1.77 F/L Bobbin ODI 3
0.58 3 141 18TH TSP
+13.24 F/L Bobbin ODI 5
0.48 3 140 13TH TSP
+11.38 F/L Bobbin ODI 5
0.57 3 140 18TH TSP
+13.81 F/L f
C/L Special I VOL 0.25 1 104 18TH TSP
+14.17 18TH TSP C/L Special I VOL 0.45 1 94 13TH TSP
+10.92 13TH TSP C/L Special I VOL 1.00 1 114 13TH TSP
+1.22 13TH TSP t
Bobbin 38 44 ODI 5
1.08 4 130 15TH TSP
+4.92 F/L Bobbin ODI 10 1.75 4 126 10TH TSP
+21.50 F/L C/L Special I VOL 0.22 1 114 15TH TSP
+4.81 15TH TSP C/L Special I VOL 0.44 1 104 10TH TSP
+21.34 10TH TSP Bobbin 38 58 WAR 10 0.70 P 4 0 1AVB
+0.00 F/L Bobbin 38 59 WAR 16 1.04 P 4 0 1AVB
+0.00 F/L Bobbin 38 62 WAR 17 1.13 P 4 0 1AVB
+0.00 F/L Bobbin 38 64 WAR 16 1.05 P 4 0 1AVB
+0.00 F/L Bobbin 38 71 ODI 11 1.45 3 139 11TH TSP
+11.33 F/L C/L Special I VOL 1.46 1 112 11TH TSP
+11.62 11TH TSP H/L Tubesheet 38 77 MAI 0.40 1 20 TTS-HL
-3.21 TTS-HL Bobbin 38 79 ODI 17 0.53 3 133 IST TSP
+2.91 F/L H/L Special I VOL 1.22 1 106 IST TSP
+0.91 IST TSP Bobbin 38 80 ODI 27 1.93 3 123 12TH TSP
+36.46 F/L C/L Special I VOL 1.21 1 100 11TH TSP
-7.53 11TH TSP Bobbin 38 82 ADI 3.58 6 84 STH TSP
+5.33 F/L H/L Special I VOL 1.00 1 112 5TH TSP
+5.91 STH TSP Bobbin 38 87 WAR 22 1.58 P 4 0 3AVB
+0.00 F/L Bobbin 38 91 IDI 1
5.57 P 1 131 TE-HL
+13.30 F/L H/L Special I MAI 4.98 1 19 TTS-HL
-7.63 TTS-HL Bobbin 38 92 ADI 2.78 6 61 IST TSP
+16.73 F/L H/L Special I VOL 0.77 1 129 IST TSP
+17.10 2ND TSP Bobbin 38 94 ODI 11 1.88 4 137 7TH TSP
+31.14 F/L Bobbin ODI 17 1.10 3 133 7TH TSP
-1.13 F/L H/L Special I VOL 0.52 1 88 7TH TSP
+16.76 7TH TSP H/L Special I VOL 0.82 1 58 7TH TSP
-1.25 7TH TSP H/L Special I VOL 1.24 1 107 7TH TSP
+31.39 7TH TSP Bobbin 38 95 IDI 57 21.41 P 1 16 TE-HL
+11.17 F/L H/L Special I MAI 7.49 1 22 TTS-HL
-9.30 TTS-HL H/L Tubesheet 39 66 SAI 0.99 1 25 TTS-HL
-1.08 TTS-HL Bobbin 39 74 ODI 9
0.66 3 139 10.3 TSP
+39.36 F/L
BWNT TUBAN II (Varsion 2.1) 07/13/1995 13:43:23 McGuire Nuclear Station - Unit Two o*******
S/G B 12/94 RFO Bobbin,C/L Special Interest,H/L Special Interest,H/L Tubesheet,U-Bend ATTACHMENT #2 - INDICATIONS OF IMPERFECTIONS INDS OF IMPERFECTIONS - SGB TEST TYPE ROW COL IND %TW VOLTS CHN DEG LOCATION EXTENT 1 C/L Special I VOL 0.19 1 155 9TH TSP
-6.58 9TH TSP C/L Special I VOL 0.23 1 130 9TH TSP
-4.04 9TH TSP C/L Special I VOL 0.39 1 117 9TH TSP
-8.93 9TH TSP Bobbin 39 87 ADI 6.03 6 66 13TH TSP
+6.29 F/L C/L Special I VOL 0.90 1 99 13TH TSP
+5.86 13TH TSP Bobbin 40 21 ODI 2
1.43 3 142 20TH TSP
+1.76 F/L C/L Special I VOL 0.17 1 77 20TH TSP
+1.83 19TH TSP Bobbin 40 24 ODI 16 0.54 3 130 12TH TSP
+40.67 F/L C/L Special I VOL 0.27 1 97 11TH TSP
-3.19 11TH TSP Bobbin 40 33 NOI 0.44 3 130 12TH TSP
+38.63 F/L Bobbin 40 56 ODI 3
1.49 3 144 2ND TSP
+3.26 F/L H/L Special I VOL 1.24 1 20 2ND TSP
+3.30 2ND TSP Bobbin 40 62 WAR 26 2.03 P 4 0 2AVB
+0.00 F/L Bobbin 40 66 WAR 17 1.08 P 4 0 1AVB
+0.00 F/L Bobbin 40 86 ODI 11 2.32 4 137 TTS-HL
+3.51 F/L H/L Special I VOL 0.21 1 67 TTS-HL
+3.75 IST TSP Bobbin 41 22 NOI 1.04 3 101 STH' TSP
+6.60 F/L H/L Special I VOL 0.85 1 77 STH TSP
+6.78 STH TSP Bobbin 41 32 WAR 19 1.14 P4 0 2AVB
+0.00 F/L Bobbin 41 38 NOI 0.40 P 1 92 12TH TSP
+0.28 F/L Bobbin 41 39 ODI 25 0.59 3 121 12TH TSP
+11.29 F/L Bobbin 41 40 WAR 16 0.94 P 4 0 1AVB
+0.00 F/L Bobbin 41 49 WAR 13 0.75 P 4 0 1AVB
+0.00 F/L Bobbin WAR 15 0.87 P 4 0 3AVB
+0.00 F/L Bobbin WAR 26 1.72 P 4 0 2AVB
+0.00 F/L i
Bobbin 41 55 WAR 20 1.18 P 4 0 1AVB
+0.00 F/L Bobbin 41 62 WAR 24 1.19 P 2 0 3AVB
+0.00 F/L Bobbin WAR 25 1.31 P 2 0 1AVB
+0.00 F/L Bobbin WAR 28 1.50 P 2 0 2AVB
+0.00 F/L Bobbin 42 33 ADI 5.39 6 46 15TH TSP
+17.54 F/L C/L Special I VOL 0.82 1 118 15TH TSP
+17.72 15TH TSP Bobbin 42 47 NOI 0.52 3 88 6TH TSP
+19.26 F/L H/L Special I VOL 0.45 1 112 6TH TSP
+19.15 6TH TSP Bobbin 42 53 WAR 12 0.67 P 4 0 1AVB
+0.00 F/L Bobbin 42 55 WAR 26 1.82 P 4 0 1AVB
+0.00 F/L
+
Bobbin 43 34 WAR 20 1.19 P 4 0 2AVB
+0.00 F/L Bobbin 43 38 ODI 28 1.46 4 122 17TH TSP
+2.59 F/L C/L Special I VOL 0.70 1 77 17TH TSP
+2.60 17TH TSP Bobbin 43 41 NOI 3.14 P 1 163 TE-HL
+17.72 F/L Bobbin IDI 70 1.96 P 1 79 TE-HL
+13.12 F/L Bobbin 43 49 ODI 16 1.34 3 130 10TH TSP
+12.58 F/L Bobbin ODI 28 0.49 3 120 10TH TSP
+13.26 F/L C/L Special I VOL 1.01 1 102 10TH TSP
+12.86 10TH TSP Bobbin 43 50 WAR 14 0.78 P 4 0 1AVB
+0.00 F/L Bobbin 43 53 ADI 2.36 6 77 STH TSP
+28.01 F/L H/L Special I VOL 1.04 1 116 STH TSP
+28.54 6TH TSP Bobbin 43 56 WAR 11 0.59 P 4 0 1AVB
+0.00 F/L Bobbin WAR 21 1.25 P 4 0 2AVB
+0.00 F/L Bobbin 43 57 WAR 8
1.61 P 2 0 17TH TSP
+0.00 F/L Bobbin 43 63 NQI 0.62 3 52 17TH TSP
+13.92 F/L C/L Special I VOL 0.29 1 106 17TH TSP
+13.73 15TH TSP Bobbin 43 71 IDI 45 11.38 P 1 19 TE-HL
+9.70 F/L Bobbin 43 85 ADI 6.42 6 78 4TH TSP
+35.29 F/L H/L Special I VOL 1.25 1 49 STH TSP
-7.62 STH TSP Bobbin 43 87 ADI 7.24 6 97 STH TSP
+30.60 F/L H/L Special I VOL 1.39 1 130 6TH TSP
-13.26 6TH TSP Bobbin 44 41 ADI 3.76 6 80 3AVB
-2.99 F/L U-Bend VOL 0.58 1 86 3AVB
~3.86 9TH TSP Bobbin 44 44 ODI 5
1.82 3 139 10TH TSP
+16.21 F/L C/L Special I VOL 0.63 1 116 10TH TSP
+16.86 10TH TSP Bobbin 44 58 NOI 0.45 3 88 20TH TSP
+7.05 F/L Bobbin 44 64 ODI 11 2.04 3 132 STH TSP
+32.14 F/L H/L Special I VOL 0.64 1 109 6TH TSP
-11.64 6TH TSP Bobbin 45 32 NQI 31.71 3 15 TTS-HL
+5.03 F/L H/L Special I NQI 0.96 1 24 TTS-HL
+4.49 TTS-HL l
BWNT TUBAN II (Version 2.1) 07/13/1995 13:43:23 McGuire Nuclear Station - Unit Two eeo*****
S/G B e*******
12/94 RFO Bobbin,C/L Special Interest,H/L Special Interest,H/L Tubesheet,U-Bend Page 12 of 13 ATTACHMENT #2 - INDICATIONS OF IMPERFECTIONS INDS OF IMPERFECTIONS - SGB TEST TYPE ROW COL IND %TW VOLTS CHN DEG LOCATION EXTENT 1 Bobbin 45 55 NOI 0.70 P 1 67 15TH TSP
+0.25 F/L C/L Special I VOL 0.65 P 1 52 ISTH TSP
+0.00 15TH TSP Bobbin 45 66 ODI 12 2.00 4 141 10TH TSP
+40.23 F/L C/L Special I VOL 0.31 1 122 9TH TSP
-5.21 9TH TSP C/L Special I VOL 0.47 1 115 9TH TSP
-3.88 9TH TSP Bobbin 45 71 NQI 2.29 3 149 8TH TSP
+21.32 F/L U-Bend VOL 0.73 1 90 8TH TSP
+21.40 1AVB Bobbin 46 44 NOI 0.65 3 131 3AVB
-20.99 F/L U-Bend VOL 0.58 1 109 3AVB
-21.00 9TH TSP Bobbin 46 50 W7F 12 2.69 P 2 0 17TH TSP
+0.00 F/L Bobbin 46 51 AD1 2.24 6 76 3RD TSP
+19.48 F/L Bobbin ADI 3.27 6 74 3RD TSP
+21.92 F/L Bobbin NQI 0.99 3 103 3RD TSP
+14.32 F/L Bobbin WAR 8
1.78 P 2 0 15TH TSP
+0.00 F/L H/L Special I VOL 0.55 1 131 3RD TSP
+17.51 3RD TSP H/L Special I VOL 0.86 1 126 3RD TSP
+22.14 3RD TSP H/L Special I VOL 1.31 1 124 3RD TSP
+14.35 3RD TSP Bobbin 46 57 WAR 6
1.31 P 2 0 17TH TSP
+0.00 F/L Bobbin 46 59 ODI 19 1.42 3 126 9TH TSP
+0.98 F/L Bobbin WAR 23 6.11 P 2 0 17TH TSP
+0.00 F/L C/L Special I SAI 0.67 1 18 9TH TSP
+1.02 9TH TSP Bobbin 46 65 ADI 4.84 6 59 4TH TSP
+37.89 F/L j
H/L Special I VOL 0.99 1 155 STH TSP
-5.55 STH TSP Bobbin 46 76 NQI 1.69 3 116 7TH TSP
-0.94 F/L H/L Special I VOL 1.87 1 100 7TH TSP
-0.93 7TH TSP H/L Special I VOL 2.18 1 123 7TH TSP
+0.25 7TH TSP Bobbin 46 77 ODI 10 2.75 4 143 4TH TSP
+31.27 F/L Bobbin ODI 20 2.06 3 125 4TH TSP
+26.59 F/L H/L Special I VOL 0.89 1 142 STH TSP
-17.22 STH TSP H/L Special I VOL 1.12 1 150 STH TSP
-12.67 STH TSP Bobbin 46 82 ADI 2.24 6 68 13TH TSP
+12.44 F/L C/L Special I VOL 0.71 1 11 12TH TSP
-10.66 12TH TSP H/L Tubesheet 47 49 SAI 0.98 1 28 TTS-HL
-0.05 TTS-HL Bobbin 47 51 WAR 9
1.95 P 2 0 17TH TSP
+0.00 F/L Bobbin 47 54 WAR 18 4.33 P 2 0 17TH TSP
+0.00 F/L Bobbir 47 61 NOI 4.99 P 1 142 TTS-CL
-1.28 F/L i
Bobbin 47 70 ADI 5.73 6 74 STH TSP
+15.01 F/L
)
H/L Special I VOL 0.56 1 134 STH TSP
+15.14 STH TSP Bobbin 48 53 WAR 17 3.87 P 2 0 17TH TSP
+0.00 F/L Bobbin 48 54 NOI 1.22 3 63 2ND TSP
+17.33 F/L 4
H/L Special I VOL 2.46 1 112 3RD TSP
-6.60 3RD TSP Bobbin 48 56 WAR 11 2.46 P 2 0 17TH TSP
+0.00 F/L C/L Special.I VOL 0.83 P 1 53 17TH TSP
+0.00 17TH TSP Bobbin 48 60 WAR 4
0.77 P 2 0 17TH TSP
+0.00 F/L Bobbin 48 61 WAR 8
1.85 P 2 0 17TH TSP
+0.00 F/L Bobbin WAR 12 2.72 P 2 0 20TH TSP
+0.00 F/L Bobbin 48 64 ADI 5.16 6 70 6TH TSP
+40.60 F/L H/L Special I VOL 0.77 1 149 7TH TSP
-3.83 7TH TSP Bobbin 48 68 NOI 0.45 3 115 7TH TSP
+33.96 F/L H/L Special I VOL 0.71 1 98 BTH TSP
-9.23 BTH TSP Bobbin 48 71 ADI 2.80 6 73 10TH TSP
+22.10 F/L C/L Special I VOL 0.59 1 119 10TH TSP
+21.85 10TH TSP H/L Tubesheet 48 74 SAI 0.48 1 43 TTS-HL
-0.25 TTS-HL Bobbin 48 82 ADI 2.96 6 74 10TH TSP
+8.69 F/L C/L Special I VOL 0.70 1 114 10TH TSP
+8.47 10TH TSP H/L Tubesheet 48 83 SAI 0.33 1 82 TTS-HL
-0.09 TTS-HL H/L Tubesheet 48 86 SAI 1.01 1 51 TTS-HL
-0.91 TTS-HL Bobbin 49 49 WAR 10 2.10 P 2 0 17TH TSP
+0.00 F/L Bobbin 49 51 WAR 15 3.48 P 2 0 17TH TSP
+0.00 F/L Bobbin 49 52 WAR 11 2.34 P2 0 17TH TSP
+0.00 F/L Bobbin 49 55 WAR 12 2.61 P 2 0 17TH TSP
+0.00 F/L Bobbin 49 57 WAR 11 2.46 P 2 0 15TH TSP
+0.00 F/L Bobbin 49 60 WAR 15 4.04 P 2 0 17TH TSP
+0.00 F/L Bobbin 49 70 ODI 27 0.80 P 1 125 6TH TSP
+0.68 F/L Bobbin WAR 9
2.36 P 2 0 18TH TSP
+0.00 F/L
100******'
BWNT TUBAN II (Varcion 2.1) 07/13/1995 13:43:23 McGuiro Nuclcar Station - Unit Two oce*****
S/G B l
co******
12/94 RFO Bobbin,C/L Special Interest,H/L Special Interest,H/L Tubesheet,U-Bend ATTACHMENT #2 - INDICATIONS OF IMPERFECTIONS INDS OF IMPERFECTIONS - SGB TEST TYPE ROW COL IND %TW VOLTS CHN DEG LOCATION EXTENT 1
'H/L Special I ODI 40 0.68 1 77 6TH TSP
+0.51 6TH TSP Bobbin 49 79 ADI 3.90 6 75 11TH TSP
+21.49
.F/L C/L Special I VOL 0.58 1 27 11TH TSP
+21.19 11TH TSP Total Indications Found = 783 Total Tubes Found = 394
BWNT TUBAN II (Version 2.1) 07/13/1995 13:57:02 McGuire Nuclear Station - Unit Two S/G C 12/94 RFO
~********
Bobbin,C/L Special Interest,H/L Special Interest,H/L Tubesheet,U-Bend Page 1 of 11 ATTACHMENT #3 - IFDICt.TIONS OF IMPERFECTIONS INDS OF IMPERFECTIONS - SGC TEST TYPE ROW COL IND %TW VOLTS CHN DEG LOCATION EXTENT 1 Bobbin 2
7 ADI 12.11 6 92 2ND TSP
+2.13 9TH TSP H/L Special I VOL 1.40 1 31 2ND TSP
+1.71 2ND TSP Bobbin 2 19 ADI 5.88 6 28 4TH TSP
+27.10 9TH TSP H/L Special I VOL 0.71 1 143 4TH TSP
+25.10 4TH TSP Bobbin 2 26 NQI 0.59 P 1 132 19TH TSP
+0.69 9TH TSP C/L Special I VOL 0.97 1 118 19TH TSP
+0.80 19TH TSP H/L Tubesheet 2 31 VOL 0.39 1 83 TTS-HL
+1.05 TTS-HL H/L Tubesheet 2 32 SAI 1.59 1 15 TTS-HL
-0.01 TTS-HL Bobbin 2 39 IDI 94 47.17 P 1 57 TE-HL
+3.89 9TH TSP Bobbin 2 51 NQI 13.17 P 1 163 TE-HL
+8.82 9TH TSP Bobbin IDI 87 5.59 P 1 73 TE-HL
+15.37 9TH TSP H/L Special I MAI 6.41 1 33 TE-HL
+8.35 TTS-HL H/L Special I SAI 5.20 1 25 TE-HL
+14.43 TTS-HL Bobbin.
2 53 ODI 22 2.91 4 128 14TH TSP
+2.35 9TH TSP C/L Special I VOL 0.61 1 82 14TH TSP
+2.40 14TH TSP Bobbin 2 56 ADI 2.48 6 54 19TH TSP
+2.51 9TH TSP C/L Special I VOL 0.50 1 119 19TH TSP
+2.26 19TH TSP Bobbin 2 64 ADI 2.06 6 58 11TH TSP'
+27.86 9TH TSP Bobbin ADI 3.70 6 75 12TH TSP
+12.32 9TH TSP i
C/L Special I VOL 0.29 1 140 10TH TSP
-16.14 10TH TSP C/L Special I VOL 0.77 1 41 10TH TSP
-2.03 10TH TSP C/L Special I VOL 0.85 1 132 12TH TSP
+13.34 12TH TSP
)
Bobbin 2 73 ODI 24 0.97 4 126 14TH TSP
+6.13 9TH TSP C/L Special I VOL 0.47 1 131 13TH TSP
-4.96 13TH TSP H/L Tubesheet 2 76 SAI 3.01 1 28 TTS-HL
-4.27 TTS-HL l
Bobbin 2 92 ODI 10 0.56 3 137 17TH TSP
+3.57 9TH TSP C/L Special I VOL 0.92 1 131 17TH TSP
+4.12 17TH TSP Bobbin 2 100 ODI 9
1.33 4 139 22ND TSP
+3.62 9TH TSP
/
C/L Special I VOL 0.53 1 138 22ND TSP
+3.74 22ND TSP Bobbin 2 102 ADI 1.11 6 55 19TH TSP
+10.75 9TH TSP Bobbin 2 105 NQI 1.24 P 1 120 3RD TSP
+0.13 9TH TSP H/L Special I SAI 0.50 1 101 3RD TSP
+0.21 3RD TSP Bobbin 2 113 ODI 3
0.69 3 142 11TH TSP
+21.51 9TH TSP Bobbin 3
9 ADI 3.63 6 75 21ST TSP
+0.86 9TH TSP C/L Special I VOL 0.49 1 75 21ST TSP
+8.53 21ST TSP Bobbin 3 14 IDI 94 6.31 P 1 56 TE-HL
+11.22 9TH TSP Bobbin 3 44 ADI 4.33 6 72 22ND TSP
+11.25 9TH TSP C/L Special I VOL 0.53 1 124 22ND TSP
+11.09 22ND TSP l
Bobbin 3 48 ADI 1,79 6 76 22ND TSP
+9.43 9TH TSP l
Bobbin 3 49 ADI 2.17 6 61 18TH TSP
+9.62 9TH TSP Bobbin ADI 2.57 6 55 12TH TSP
+24.56 9TH TSP Bobbin ADI 3.31 6 48 22ND TSP
+4.56 9TH TSP l
Bobbin ADI 3.55 6 42 18TH TSP
+7.12 9TH TSP Bobbin ADI 3.63 6 65 22ND TSP
+6.26 9TH TSP Bobbin ADI 3.67 6 54 22ND TSP
+10.26 9TH TSP Bobbin ADI 3.97 6 57 22ND TSP
+2.97 9TH TSP Bobbin ADI 4.80 6 61 21ST TSP
-1.38 9TH TSP C/L Special I VOL 0.20 1 38 22ND TSP
+10.09 21ST TSP C/L Special I VOL 0.35 1 76 12TH TSP
+20.08 12TH TSP C/L Special I VOL 0.35 1 123 18TH TSP
+6.78 18TH TSP C/L Special I VOL 0.37 1 131 18TH TSP
+9.50 18T9 TSP C/L Special I VOL 0.41 1 79 12TH TSP
+21.75 12TH TSP C/L Special I VOL 0.42 1 65 12TH TSP
+17.48 12TH TSP C/L Special I VOL 0.42 1 138 18TH TSP
+4.65 18TH TSP C/L Special I VOL 0.44 1 105 12TH TSP
+24.38 12TH TSP C/L Special I VOL 0.48 1 98 12TH TSP
+18.90 12TH TSP C/L Special I VOL 0.62 1 54 22ND TSP
+18.59 21ST TSP C/L Special I VOL 0.73 1 130 22ND TSP
+4.19 21ST TSP C/L Special I VOL 1.04 1 134 22ND TSP
+2.62 21ST TSP C/L Special I VOL 1.40 1 132 22ND TSP
+6.15 21ST TSP C/L Special I VOL 0.33 P 1 131 21ST TSP
-0.07 21ST TSP Bobbin 3 52 ADI 4.57 6 54 16TH TSP
+0.90 to
+6.18 9TH TSP Bobbin 3 55 ADI 1.36 6 69 22ND TSP
+8.47 9TH TSP Bobbin ADI 2.39 6 52 22ND TSP
+4.40 9TH TSP Bobbin ADI 6.11 6 55 22ND TSP
+13.20 9TH TSP
i BWNT TUBAN II (Varsion 2.1) 07/13/1995 13:57:02 i
McGuiro Nuclear Station - Unit Two eo******
S/G C l
12/94 RFO Bobbin,C/L Special Interest,H/L Special Interest,H/L Tubesheet,U-Bend Page 2 of 11 ATTACHMENT #3 - INDICATIONS OF IMPERFECTIONS INDS OF IMPERFECTIONS - SGC TEST TYPE ROW COL IND %TW VOLTS CHN DEG LOCATION EXTENT 1 Bobbin ADI 7.12 6 50 22ND TSP
+15.29 9TH TSP C/L Special I VOL 0.54 1 42 22ND TSP
+13.18 21ST TSP C/L Special I VOL 0.55 1 78 22ND TSP
+17.67 21ST TSP C/L Special I VOL 0.61 1 130 22ND TSP
+7.01 21ST TSP C/L Special I VOL 0.78 1 123 22ND TSP
+8.23 21ST TSP C/L Special I VOL 0.82 1 75 22ND TSP
+15.40 21ST TSP C/L Special I VOL 1.43 1 147 22ND TSP
+4.03 21ST TSP H/L Special I 3 93 SAI 0.23 P 1 30 3RD TSP
+0.09 3RD TSP Bobbin 3 95 IDI 95 16.83 P 1 39 TE-HL
+5.24 9TH TSP Bobbin 3 104 NQI 1.85 P 1 78 3RD TSP
+0.11 9TH TSP H/L Special I MAI 1.33 1 66 3RD TSP
+0.20 3RD TSP Bobbin 3 105 ODI 14 2.12 4 136 19TH TSP
+37.10 9TH TSP C/L Special I VOL 0.67 1 103 16TH TSP
-4.99 16TH TSP Bobbin 4 29 ODI 27 0.55 3 123 22ND TSP
+8.55 9TH TSP C/L Special I NQI 0.53 1 40 22ND TSP
+9.04 22ND TSP Bobbin 4 42 NQI 9.10 P 1 144 TE-HL
+14.90 9TH TSP H/L Special I MAI 2.59 1 27 TE-HL
+13.05 TTS-HL H/L Special I SAI 1.21 1 16 TE-HL
+2.74 TTS-HL Bobbin 4 53 IDI 99 63.05 P 1 37 TE-HL
+5.24 9TH TSP Bobbin 4 87 ODI 26 1.74 3 124 22ND TSP
+15.65 9TH TSP C/L Special I VOL 0.55 1 75 22ND TSP
+16.20 22ND TSP Bobbin 4 88 IDI 63 44.20 P 1 26 TE-HL
+12.05 9TH TSP I
Bobbin 4 101 ODI 10 0.95 3 137 TTS-CL
+6.00 9TH TSP Bobbin 5
6 NOI 12.10 P 1 159 TE-HL
+10.98 97H TSP Bobbin 5
8 ADI 2,76 6 52 19TH TSP
-1,31 9TH TSP C/L Special I VOL 0.68 1 98 19TH TSP
-1.52 19TH TSP Bobbin 5 11 IDI 45 20.18 P 1 18 TE-HL
+11.01 9TH TSP H/L Special I SAI 5.23 1 27 TE-HL A10.51 TTS-HL Bobbin 5 26 IDI 85 15.47 P 1 78 TE-HL
+10.49 9TH TSP Bobbin 5 27 ODI 16 1.16 3 132 22ND TSP
+11.52 9TH TSP C/L Special I VOL 0.80 1 104 22ND TSP
+11.50 22ND TSP Bobbin 5 28 ODI 11 1.29 3 136 11TH TSP
+9.61 9TH TSP C/L Special I VOL 0.69 1 122 11TH TSP
+9.63 11TH TSP Bobbin 5 32 NQI 0.63 3 63 22ND TSP
+3.87 9TH TSP C/L Special I VOL 0.87 1 114 22ND TSP
+5.14 22ND TSP Bobbin 5 36 ODI 17 1.77 3 131 18TH TSP
+17.70 9TH TSP C/L Special I VOL 0.79 1 119 17TH TSP
-4.44 17TH TSP Bobbin 5 40 NOI 17.84 3 32 TE-CL
+17.17 9TH TSP H/L Special I 5 65 VOL 1.86 1 149 IST TSP
+13.77 IST TSP Bobbin 5 73 ADI 3.42 6 31 11TH TSP
+9.06 9TH TSP Bobbin 5 79 ADI 4.75 6 86 IST TSP
+14.22 9TH TSP
.H/L Special I VOL 0.46 1 122 2ND TSP
-6.30 2ND TSP Bobbin 5 109 NQI 1.17 P 1 36 4TH TSP
-0.09 9TH TSP H/L Special I MAI 0.37 1 61 4TH TSP
-0.11 4TH TSP Bobbin 6 17 ODI 38 0.40 P 1 117 6TH TSP
+0.31 F/L H/L Tubesheet 6 24 VOL 1.68 1 160 TTS-HL
-0.11 TTS-HL Bobbin 6 26 NQI 0.88 3 110 21ST TSP
+3.09 F/L C/L Special I VOL 0.27 1 58 21ST TSP
+1.03 21ST TSP C/L Special I VOL 0.64 1 100 21ST TSP
+3.08 21ST TSP Bobbin 6 37 ODI 7
2.53 4 142 11TH TSP
+2.23 F/L C/L Special I VOL 0.61 1 111 11TH TSP
+4.99 10TH TSP C/L Special I VOL 0.77 1 116 11TH TSP
+7.43 10TH TSP C/L Special I VOL 1.30 1 120 11TH TSP
+1.77 10TH TSP H/L Tubesheet 6 40 SAI 0.43 1 61 TTS-HL
+0.00 TTS-HL Bobbin 6 44 NQI 12.31 P 1 16 TE-CL
+18.28 F/L H/L Tubesheet 6 58 SAI 1.26 1 21 TTS-HL
-1.33 TTS-HL Bobbin 6 61 ADI 2.58 6 79 4TH TSP
+12.82 F/L Bobbin ODI 8
1.41 4 136 4TH TSP
+20.04 F/L H/L."pecial I VOL 0.37 1 37 4TH TSP
+12.93 4TH TSP H/L Special I VOL 0.42 1 102 4TH TSP
+20.03 4TH TSP Bobbin 6 66 NQI 0.47 3 104 TTS-HL
+6.62 F/L Bobbin 6 69 NQI 22.47 P 1 166 TE-HL
+6.34 F/L H/L Special I MAI 3.88 1 26 TTS-HL
-14.00 TTS-CL Bobbin 6 71 ADI 3.13 6 77 3RD TSP
+6.32 F/L Bobbin 6 73 ODI 4
0.31 3 140 3RD TSP
+28,85 F/L
3FK? TUBAN II (Version 2.1) 07/13/1995 13:57:02 McGuire Nuclear Station - Unit Two eeo*****
S/G C 12/94 RFO Bobbin,C/L Special-Interest,H/L Special Interest,H/L Tubesheet,U-Bend ATTACHMENT #3 - INDICATIONS OF IMPERFECTIONS INDS OF IMPERFECTIONS - SGC TEST TYPE ROW COL IND %TW VOLTS CHN DEG LOCATION EXTENT 1 H/L Special I VOL 0.45 1 128 4TH TSP
-14.94 4TH TSP Bobbin 6 74 ODI 4
0.65 3 140 2ND TSP
+6.13 F/L Bobbin ODI 15 1.81 4 130 10TH TSP
+37.80 F/L H/L Special I VOL 0.56 1 126 2ND TSP
+6.95 2ND TSP H/L Special I VOL 0.57 1 97 2ND TSP
+3.91 2ND TSP H/L Special I VOL 0.58 1 107 2ND TSP
+6.21 2ND TSP H/L Special I VOL 0.62 1 59 2ND TSP
+7.83 2ND TSP H/L Special I VOL 0.71 1 131 2ND TSP
+9.17 2ND TSP H/L Special I VOL 1.02 1 89 2ND TSP
+2.79 2ND TSP Bobbin 6 79 ODI 12 0.62 3 136 9TH TSP
-1.41 F/L Bobbin 6 81 NOI 0.52 3 50 3RD TSP
+10.83 F/L H/L Special I VOL 0.60 1 118 3RD TSP
+10.82 3RD TSP Bobbin 7
6 ADI 6.19 6 84 10TH TSP
+36.22 F/L C/7. Special I VOL 1.00 1 94 9TH TSP
-0.22 9TH TSP Bobbin 7 38 ODI 12 1.37 3 135 6TH TSP
+5.21 F/L H/L Special I VOL 0.42 1 58 6TH TSP
+5.23 6TH TSP Bobbin 7 53 ODI 32 0.80 P 1 122 3RD TSP
+0.29 F/L Bobbin 7 63 ADI 3.95 6 59 3RD TSP
+14.93 F/L H/L Special I VOL 0.74 1 106 3RD TSP
+15.15 3RD TSP Bobbin 7 67 ODI 13 0.60 3 133 3RD TSP
+14.00 F/L I
H/L Special I NCL 0.85 1 49 3RD TSP
+15.13 3RD TSP H/L Tubesheet 7 80 SAI 0.80 1 44 TTS-HL
+0.00 TTS-HL Bobbin 8 32 IDI 40 9.41 P 1 159 TE-HL
+12.15 F/L H/L Special I SAI 1.99 1 27 TE-HL
+15.83 TTS-HL H/L Specini 1 SAI 3.30 1 28 TE-HL
+11.96 TTS-HL H/L Spen.3al I SAI 4.68 1 16 TE-HL
+8.20 TTS-HL Bobbin 8 38 NOI 1.12 3 122 6TH TSP
+38.55 F/L H/L Spwnn' I VOL 1.37 1 119 7TH TSP
-5.51 7TH TSP l
Bobbin 8 39 NOI 0.39 3 123 6TH TSP
+19.44 F/L H/L Tubesheet B 41 SAI 0.74 1 19 TTS-HL
-2.40 TTS-HL Bobbin 8 63 ODI 26 1.80 4 124 6TH TSP
+22.45 F/L Bobbin 8 64 ADI 5.72 6 68 3RD TSP
+21.08 F/L H/L Special I VOL 1.16 1 110 3RD TSP
+21.09 3RD TSP Bobbin 8 79 ODI 29 0.40 3 120 7TH TSP
+27.66 F/L H/L Special I VOL 0.76 1 38 BTH TSP
-18.59 BTH TSP H/b Special I VOL 0.78 1 7"
8TH TSP
-0.96 8TH TSP H/L Special I VOL 0.92 1 4; BTH TSP
-16.76 8TH TSP H/L Special I VOL 0.96 1 61 8TH TSP
-10.77 BTH TSP H/L Special I VOL 1.28 1 156 BTH TSP
-12.74 BTH TSP Bobbin 8 96 NOI
- 0. 35 P 1 109 4TH TSP
+0.00 F/L H/L Special I SAI C.31 1 80 4TH TSP
+0.04 4TH TSP Bobbin 8 109 NOI 0.46 P 1 41 4TH TSP
+0.08 F/L H/L Special I SAI 0.14 P 1 81 4TH TSP
+0.00 4TH TSP Bobbin 9
8 ODI 7
2.05 3 137 6TH TSP
+16,76 F/L H/L Special I VOL 1.36 1 147 6TH TSP
+16.99 6TH TSP Bobbin 9 12 NOI 0.52 P 1 69 2ND TSP
+0.13 F/L H/L Special I SAI 0.31 P 1 83 2ND TSP
+0.03 2ND TSP Bobbin 9 13 NQI 7.41 P 1 169 TE-HL
+14.42 F/L H/L Special I SAI 3.99 1 16 TE-HL
+14.03 TTS-HL Bobbin 9 46 NOI 0.47 P 1 112 14TH TSP
+0.16 F/L Bobbin 9 62 NOI 0.72 3 106 22ND TSP
+14.08 F/L C/L Special I VOL 0.62 1 135 22ND TSP
+13.30 22ND TSP Bobbin 9 73 ADI 4.62 S 67 2ND TSP
+12.21 F/L H/L Special I VOL 9.'i71 115 2ND TSP
+12.74 2ND TSP Bobbin 9 84 NOI 0.72 3 114 4TH TSP
+2.06 F/L H/L Special I VOL 0.90 1 174 4TH TSP
+1.99 4TH TSP Bobbin 9 88 NOI 0.51 P 1 68 2ND TSP
+0.08 F/L H/L Special I MAI O.14 P 1 56 2ND TSP
+0.00 2ND TSP Bobbin 9 91 ODI 19 1.28 4 130 3RD TSP
+19.65 F/L H/L Special I VOL 0.62 1 116 3RD TSP
+18.59 3RD TSP H/L Special I VOL 1.22 1 127 3RD TSP
+19.97 3RD TSP C/L Special I 10 13 VOL 0.72 1 135 22ND TSP
+11.49 22ND TSP Bobbin 10 20 ADI 6.18 6 69 4TH TSP
+24.01 F/L H/L Special I VOL 1.16 1 102 4TH TSP
+24.24 4TH TSP H/L Tubesheet 10 21 SAI 0.37 1 84 TTS-HL
-0.09 TTS-HL
BWNT TUBAN II (Varsion 2.1) 07/13/1995 13:57:02 McGuire Nuclear Station - Unit Two eeese***.
SIG C 12/94 RPO Bobbin,C/L Special Interest,H/L Special Interest,H/L Tubesheet,U-Bend Page 4 of 11 ATTACHMENT #3 - INDICATIONS OF IMPERFECTIONS INDS OF IMPERFECTIONS - SGC TEST TYPE ROW COL IND %TW VOLTS CHN DEG LOCATION EXTENT 1 Bobbin 10 43 NOI 0.54 P 1 85 14TH TSP
+0.48 F/L Bobbin 10 63 NQI 0.81 3 103 3RD TSP
+6.74 F/L H/L Special I ODI 40 1.17 1 30 3RD TSP
+6.61 3RL TSP Bobbin 10 64 ADI 2.82 6 67 3RD TSP
+17.51 F/L H/L Special I VOL 0.70 1 38 3RD TSP
+17.80 3RD TSP Bobbin 10 100 ADI 3.59 6 70 10TH TSP
+37.34 F/L C/L Special I VOL 0.70 1 85 9TH TSP
-8.09 9TH TSP Bobbin 11 7 ODI 4
0.52 P 1 136 4TH TSP
-0.08 F/L Bobbin 11 22 NQI 0.62 3 124 11TH TSP
+28.57 F/L C/L Special I VOL 0.94 1 113 11TH TSP
+28.87 11TH TSP Bobbin 11 28 ADI 5.52 6 61 20TH TSP
+5.30 F/L C/L Special I VOL 0.86 1 85 20TH TSP
+5.38 20TH TSP Bobbin 11 29 NQI 0.62 3 52 17TH TSP
+5.00 F/L C/L Special I VOL 0.37 1 80 17TH TSP
+5.14 17TH TSP H/L Tubesheet 11 45 SAI 4.50 1 16 TTS-HL
-4.76 TTS-HL Bobbin 11 48 NOI 0.74 3 145 12TH TSP
+37.81 F/L C/L Special I VOL 0.75 1 26 11TH TSP
-6.21 11TH TSP Bobbin 11 67 IDI 41 9.42 P 1 14 TE-HL
+12.52 F/L H/L Tubesheet 11 69 MAI 0.36 1 24 TTS-HL
-1.02 TTS-HL Bobbin 11 72 IDI 49 15.16 P 1 17 TE-HL
+16.39 F/L H/L Tubesheet MAI 1.39 1 19 TTS-HL
-5.01 TTS-HL Bobbin 11 76 ODI 21 1.54 4 125 17TH TSP
+4.19 F/L C/L Special I VOL 0.67 1 268 17TH TSP
+4.58 17TH TSP Bobbin 11 77 ODI 25 0.59 4 122 STH TSP
+11.57 F/L H/L Special I VOL 0.23 1 60 STH TSP
+11.89 STH TSP Bobbin 12 4 ADI 4.98 6 92 22ND TSP
+9.44 F/L C/L Special I VOL 0.88 1 129 22ND TSP
+9.05 22ND TSP Bobbin 12 22 NOI 0.63 3 50 6TH TSP
+11.14 F/L Bobbin ODI 13 0.56 3 133 6TH TSP
+9.59 F/L H/L Special I VOL 0.50 1 141 6TH TSP
+11.47 6TH TSP H/L Special I VOL 0.50 1 154 6TH TSP
+8.15 GTH TSP H/L Special I VOL 0.54 1 159 6TH TSP
+10.04 6TH TSP H/L Special I VOL 0.59 1 138 6TH TSP
+18.63 6TH TSP Bobbin 12 27 IDI 61 8.71 P *i 22 TE-HL
+12.53 F/L H/L Tubesheet 12 30 MAI 1.31 1 37 TTS-HL
-4.69 TTS-HL H/L Tubesheet 12 68 MAI 4.61 1 21 TTS-HL
-3.69 TTS-HL Bobbin 12 75 ADI 1.75 6 81 3RD TSP
+21.80 F/L H/L Special I VOL 0.60 1 124 3RD TSP
+22.04 3RD TSP Bobbin 12 88 ADI 3.80 6 65 6TH TSP
+36.24 F/L H/L Special I VOL 0.77 3 124 7TH TSP
-7.05 7TH TSP Bobbin 12 91 ODI 27 0.94 4 121 2ND TSP
+18.40 F/L H/L Special I VOL 0.96 1 152 3RD TSP
-5.66 3RD TSP Bobbin 13 11 IDI 44 26.06 P 1 16 TE-HL
+15.36 F/L H/L Special I MAI 5.92 1 26 TE-HL
+15.86 TE-HL Bobbin 13 66 IDI 53 13.65 P 1 18 TE-HL
+10.77 F/L Bobbin IDI 59 18.86 P 1 20 TE-HL
+16.52 F/L H/L Special I MAI 0.91 1 23 TE-HL
+7.06 TE-HL H/L Special I MAI 5.29 1 26 TE-HL
+17.79 TE-HL l
H/L Special I SAI 1.43 1 11 TE-HL
+11.04 TE-HL Bobbin 13 76 IDI 50 9.02 P 1 17 TE-HL
+17.30 F/L Bobbin IDI 86 18.43 P 1 30 TE-HL
+14.42 F/L Bobbin 13 77 IDI 94 2.52 P 1 46 TE-HL
+6.36 F/L Bobbin 13 79 ADI 1.84 6 70 STH TSP
+19.19 F/L H/L Special I VOL 0.82 1 133 STH TSP
+21.49 5TH TSP Bobbin 13 88 ODI 5
0.83 3 139 7TH TSP
+4.04 F/L H/L Special I VOL 0.94 1 124 7TH TSP
+4.15 7TH TSP Bobbin 13 97 ODI 23 0.80 3 125 11TH TSP
+34.29 F/L C/L Special I VOL 0.80 1 66 10TH TSP
-10.34 10TH TSP Bobbin 13 111 NOI 6.14 P 1 165 TTS-HL
-0.87 F/L Bobbin 14 23 IDI 50 30.24 P1 18 TE-HL
+13.33 F/L H/L Special I SAI 0.35 1 24 TE-HL
+9.88 TE-HL H/L Special I MAI 3.51 1 16 TE-HL
+13.49 TTS-HL H/L Tubesheet 14 35 SAI 1.13 1 39 TTS-HL
-4.53 TTS-HL Bobbin 14 48 ODI 3
2.52 3 140 20TH TSP
+4.30 F/L C/L Special I SAI 0.84 1 40 20TH TSP
+4.61 20TH TSP
BWNT TUBAN II (Version 2.1) 07/13/1995 13:57:02 McGuire Nuclear Station - Unit Two S/G C 12/94 RFO Bobbin,C/L Special Interest,H/L Special Interest,H/L Tubesheet,U-Bend i
ATTACHMENT #3 - INDICATIONS OF IMPERFECTIONS INDS OF IMPERFECTIONS - SGC TEST TYPE ROW COL IND %TW VOLTS CHN DEG LOCATION EXTENT 1 Bobbin 14 61 ODI 32 2.50 4 124 10TH TSP
+4.42 F/L C/L Special I VOL 1.57 1 139 10TH TSP
+4.78 10TH TSP Bobbin 14 67 IDI 47 8.90 P 1 16 TE-HL
+3.96 F/L Bobbin IDI 65 13.41 P 1 22 TE-HL
+7.85 F/L Bobbin 14 71 IDI 50 9.70 P 1 17 TE-HL
+10.29 F/L Bobbin IDI 56 17.60 P 1 19 TE-HL
+16.17 F/L Bobbin IDI 79 17.50 P 1 27 TE-HL
+15.26 F/L Bobbin 14 72 IDI 53 14.66 P 1 18 TE-HL
+18.37 F/L H/L Tubesheet MAI 2.44 1 18 TTS-HL
-3.05 TTS-HL Bobbin 14 74 ADI 3.96 6 80 1ST TSP
+16.95 F/L H/L Tubesheet MAI 1.21 1 10 TTS-HL
-4.63 TTS-HL H/L Special I VOL 0.90 1 138 2ND TSP
-4.45 2ND TSP H/L Tubesheet 14 78 MAI 3.62 1 27 TTS-HL
-4.16 TTS-HL Bobbin 14 83 ADI 3.84 6 69 3RD TSP
+8.12 F/L H/L Special I VOL 0.56 1 47 3RD TSP
+5.34 2RD TSP c
H/L Special I VOL 0.59 1 132 3RD TSP
+8.92 3RD TSP Bobbin 14 94 ODI 5
0.44 3 139 4TH TSP
+25.38 F/L Bobbin ODI 16 1.49 3 131 4TH TSP
+26.15 F/L Bobbin ODI 18 0.71 3 129 4TH TSP
+26.89 F/L H/L Special I VOL 2.26 1 120 4TH TSP
+26.44 4TH TSP Bobbin 14 101 ADI 2.04 6 66 11TH TSP
+2.51 F/L C/L Special I VOL 2.30 1 135 11TH TSP
+2.58 11TH TSP Bobbin 14 111 NQI 0.38 3 49 13TH TSP
+17.84 F/L I
C/L Special I VOL 0.60 1 99 12TH TSP
-4.60 12TH TSP Bobbin 15 20 NQI 36.97 P 1 7 TE-HL
+5.46 F/L H/L Special 1 MAI 0.77 1 41 TE-HL
+5.22 TE-HL Bobbin 15 30 NQI 5.04 P 1 111 TE-HL
+11.41 F/L Bobbin 15 44 ODI 16 1.25 3 130 21ST TSP
+1.87 F/L C/L Special I VOL 1.05 1 101 21ST TSP
+2.18 21ST TSP Bobbin 15 57 ODI 9
0.83 3 135 5TH TSP
+28.34 F/L H/L Special I VOL 1.18 1 133 6TH TSP
-16.22 6TH TSP Bobbin 15 82 ADI 2.44 6 79 3RD TSP
+24.20 F/L H/L Special I VOL 0.46 1 150 3RD TSP
+27.24 3RD TSP Bobbin 15 83 ODI 14 3.07 4 131 IST TSP
+15.67 F/L H/L Special I VOL 0.66 1 167 2ND TSP
-5.75 2ND TSP Bobbin 15 88 ODI 16 1.34 3 131 1UTH TSP
+32.29 F/L C/L Special I VOL 1.08 1 96 9TH Tsk
-12.38 9'.'H TSP Bobbin 15 95 ADI 4.76 6 87 3RD TSP
+36.75 F/L H/L Special I VOL 1.13 1 138 4TH TSP
-7.26 4TH TSP Bobbin 16 11 ADI 2.92 6 77 IST TSP
+5.40 F/L H/L Special I VOL 1.64 1 129 IST TSP
+5.13 IST TSP Bobbin 16 16 NQI 7.14 P 1 146 TE-HL
+14.27 F/L Bobbin 16 18 NQI 11.25 P 1 159 TE-HL
+11.42 F/L Bobbin 16 52 ODI 23 0.54 3 124 10TH TSP
+26.19 F/L C/L Special I VOL 0.56 1 85 10TH TSP
+26.83 10TH TSP Bobbin 16 66 NQI 3.29 P 1 35 TE-HL
+10.36 F/L r
Bobbin 16 79 ADI 3.97 6 87 5TH TSP
+5.54 F/L H/L Special I VOL 0.57 1 139 STH TSP
+6.39 STH TSP Bobbin 16 100 ODI 28 0.58 3 122 13TH TSP
+2.15 F/L C/L Special I VOL 0.71 1 129 13TH TSP
+2.54 13TH TSP H/L Tubesheet 17 30 SAI 0.06 1 162 TTS-HL
-4.77 TTS-HL H/L Tubesheet 17 60 SAI 0.73 1 19 TTS-HL
-0.93 TTS-HL Bobbin 17 63 ADI 4.10 6 56 4TH TSP
+13.98 F/L Bobbin ADI 4.41 6 69 4TH TSP
+11.46 F/L Bobbin ADI 6.60 6 73 4TH TFP
+19.82 F/L H/L Special I VOL 0.48 1 140 4TH TSP
+12.94 4TH TSP H/L Special I VOL 0.80 1 137 4TH TSP
+18.59 4TH TSP H/L Special I VOL 0.87 1 130 4TH TSP
+16.08 4TH TSP H/L Special I VOL 1.50 1 113 4TH TSP
+22.86 4TH TSP Bobbin 17 70 ADI 3.09 6 71 17TH TSP
+3.93 F/L C/L Special I VOL 0.67 1 95 17TH TSP
+3.98 17TH TSP l
Bobbin 17 71 ADI 2.24 6 77 2ND TSP
+8.07 F/L H/L Special I VOL 0.50 1 101 2ND TSP
+9.36 2ND TSP i
Bobbin 17 72 ADI 1.94 6 52 STH TSP
+18.62 F/L H/L Special I VOL 0.59 1 90 STH TSP
+20.76 STH TSP i
BWN'I TUBAN II (Version 2.1) 07/13/1995 13:57:02 McGuire Nuclear Station - Unit Two
- eeee***
S/G C eeeee***
12/94 RFO Bobbin,C/L Special Interest,H/L Special Interest,H/L Tubesheet,U-Bend Page 6 of 11 ATTACHMENT #3 - INDICATIONS OF IMPERFECTIONS INDS OF IMPERFECTIONS - SGC TEST TYPE ROW COL IND %TW VOLTS CHN DEG LOCATION EXTENT 1 Bobbin 17 98 ADI 2.87 6 77 10TH TSP
+16.25 F/L C/L Special I VOL 0.53 1 114 10TH TSP
+16.54 10TH TSP Bobbin 18 11 NQI 25.21 P 1 12 TE-HL
+7.96 F/L Bobbin 18 19 ADI 0.91 6 64 13TH TSP
+11.69 F/L C/L Special I VOL 0.29 1 119 13TH TSP
+11.23 13TH TSP Bobbin 18 20 ODI 34 1.59 3 115 22ND TSP
+17.90 F/L C/L Special I SAI 0.74 1 37 21ST TSP
-2.10 21ST TSP Bobbin 18 29 NOI 9.16 P 1 150 TE-HL
+13.87 F/L H/L Special I MAI 4.13 1 203 TE-HL
+13.93 TTS-HL Bobbin 18 31 NQI 7.56 P 1 40 TE-HL
+3.44 F/L H/L Tubesheet SAI 2.00 1 14 TTS-HL
-4.60 TTS-HL H/L Special I SAI 1.11 1 20 TE-HL
+16.74 TE-HL H/L Tubesheet 18 60 SAI 2.48 1 16 TTS-HL
-4.95 TTS-HL H/L Tubesheet 18 61 SAI 3.03 1 29 TTS-HL
-4.31 TTS-HL Bobbin 18 62 ADI 2.94 6 45 14TH TSP
+6.88 F/L C/L Special I VOL 0.34 1 141 14TH TSP
+6.68 14TH TSP H/L Tubecheet 18 65 SAI 1.82 1 20 TTS-HL
-4.26 TTS-HL Bobbin 18 90 ADI 3.91 6 73 STH TSP
+37.80 F/L H/L Special I VOL 0.81 1 152 6TH TSP
-7.23 6TH TSP Bobbin 18 111 NOI 0.47 3 84 2ND TSP
+4.55 F/L Bobbin ADI 5.07 6 76 11TH TSP
+17.80 F/L H/L Special I VOL 0.98 1 116 2ND TSP
+4.66 2ND TSP C/L Special I VOL 0.93 1 63 11TH TSP
+18.21 11TH TSP Bobbin 19 48 NOI 0.37 3 110 12TH TSP
+6.84 F/L C/L Special I VOL 0.67 1 97 12TH TSP
+7.27 12TH TSP Bobbin 19 51 ADI 2.96 6 81 6TH TSP
+34.00 F/L Bobbin ADI 3.35 6 77 19TH TSP
+4.13 F/L H/L Special I VOL 1.09 1 124 7TH TSP
-10.77 7TH TSP C/L Special I VOL 0.52 1 89 19TH TSP
+3.65 19TH TSP H/L Tubesheet 19 63 MAI 1.36 1 225 TTS-HL
-4.96 TTS-HL H/L Tubesheet SAI 1,54 1 13 TTS-HL
-2.67 TTS-HL Bobbin 19 66 NQI 1.45 3 29 18TH TSP
+8.51 F/L Bobbin 19 71 ADI 3.19 6 68 IST TSP
+5.36 F/L H/L Special I VOL 0.90 1 11d 1ST TSP
Bobbin 19 80 NOI 0.64 3 62 22ND TSP
+10.76 F/L Bobbin 19 85 ODI 4
0.85 3 141 STH TSP
+28.70 F/L H/L Special I VOL 0.78 1 113 6TH TSP
-16.94 6TH TSP Bobbin 19 86 ADI 5.76 6 33 BTH TSP
+8.71 F/L U-Bend VOL 0.69 1 112 8TH TSP
+8.62 BTH TSP Bobbin 19 95 NOI 0.75 3 110 10TH TSP
+30.22 F/L C/L Special I VOL 1.23 1 114 9TH TSP
-14.16 9TH TSP Bobbin 19 97 ADI 3.77 6 76 4TH TSP
+16.42 F/L H/L Special I VOL 1.53 1 154 4TH TSP
+19.18 4TH TSP Bobbin 19 100 ODI 16 0.38 3 132 4TH TSP
+32.83 F/L H/L Special I VOL 0.76 1 159 STH TSP
-12.88 STH TSP Bobbin 20 20 IDI 76 17.30 P 1 71 TE-HL
+13.52 F/L H/L Tubesheet 20 44 SAI 4.27 1 12 TTS-HL
-3.50 TTS-HL H/L Tubesheet 20 53 SAI 0.20 1 26 TTS-HL
-3.53 TTS-HL Bobbin 20 82 ADI 2.88 6 63 15TH TSP
+3.25 F/L C/L Special I VOL 1.41 1 58 15TH TSP
+3.47 15TH TSP Bobbin 20 87 ADI 4.83 6 69 STH TSP
+26.60 F/L H/L Special I VOL 1.41 1 116 6TH TSP
-20.07 6TH TSP H/L Tubesheet 20 89 VOL 1.04 1 139 TTS-HL
+2.13 TTS-HL Bobbin 20 97 ADI 2.02 6 57 13TH TSP
+12.50 F/L C/L Special I VOL 0.77 1 103 12TH TSP
-11.52 12TH TSP Bobbin 20 98 ODI 25 0.68 3 125 3RD TSP
+3.72 F/L Bobbin ODI 28 0.60 3 122 2ND TSP
+1.19 F/L H/L Special I VOL O.98 1 109 2ND TSP
+1.17 2ND TSP H/L Special I VOL 1.17 1 149 3RD TSP
+4.03 3RD TSP Bobbin 20 99 ODI 18 0.94 3 130 16TH TSP
+2.91 F/L C/L Special I VOL 0.64 1 79 16TH TSP
+3.05 16TH TSP H/L Tubesheet 21 22 NOI 1.04 1 23 TTS-HL
+0.06 TTS-HL Bobbin 21 36 NQI 9.07 P 1 148 TE-HL
+14.94 F/L H/L Tubesheet SAI 1.51 1 24 TTS-HL
-3.62 TTS-HL H/L Special I MAI 0.84 1 31 TTS-HL
-9.19 TTS-HL
B!?NT TUBAN II (Varsion 2.1) 07/13/1995 13:57:02 McGuire Nuclear Station - Unit Two S/G C o*******
12/94 RFO Bobbin,C/L Special Interest,H/L Special Interest,H/L Tubesheet,U-Bend Page 7 of 11 ATTACHMENT #3 - INDICATIONS OF IMPERFECTIONS INDS OF IMPERFECTIONS - SGC TEST TYPE ROW COL IND %TW VOLTS CHN DEG LOCATION EXTENT 1 H/L Special I SAI 1.55 1 18 TTS-HL
-10.21 TTS-HL H/L Special I SAI 2.02 1 24 TTS-HL
-4.32 TTS-HL H/L Special I SAI 2.42 1 4 TTS-HL
-3.22 TTS-HL H/L Special I SAI 2.75 1 11 TTS-HL
-6.25 TTS-HL Bobbin 21 56 NQI 0.88 3 90 11TH TSP
+5.49 F/L C/L Special I VOL 0.98 1 85 11TH TSP
+5.90 11TH TSP Bobbin 21 57 ODI 6
0.49 3 141 STH TSP
+23.76 F/L j
l f
H/L Special I VOL 1.02 1 128 6TH TSP
-20.26 6TH TSP I
H/L Special I VOL 1.11 1 138 6TH TSP
-10.38 6TH TSP Bobbin 21 69 WAR 14 1.22 P 4 0 2AVB
+0.00 F/L i
Bobbin WAR 36 2.45 P 4 0 3AVB
+0.00 F/L U-Bend VOL 0.96 P 1 121 3AVB
+0.00 3AVB Bobbin 21 72 WAR 16 0.69 P 4 0 3AVB
+0.00 F/L H/L Special I 21 86 VOL 0.88 1 40 1ST TSP
-0.57 IST TSP Bobbin 22 59 ADI 2.71 6 75 11TH TSP
+31.85 F/L C/L Special I VOL 0.74 1 309 10TH TSP
-12.05 10TH TSP Bobbin 22 94 ADI 4.22 6 76 STH TSP
+38.29 F/L H/L Special I VOL 0.62 1 57 6TH TSP
-5.99 6TH TSP Bobbin 22 106 NQI 3.70 P 1 26 TE-CL
+19.07 F/L l
Bobbin IDI 13 1.22 P 1 131 TTS-CL
-1.30 F/L Bobbin 22 107 NOI 3.80 P 1 24 TE-CL
+19.00 F/L l
Bobbin NQI 6.14 P 1 21 TE-CL
+15.13 F/L J
Bobbin NQI 6.36 P 1 22 TE-CL
+9.28 F/L Bobbin 23 14 NQI 6.37 P 1 142 TE-HL
+18.01 F/L H/L Tubesheet SAI 5.85 1 23 TTS-HL
-3.19 TTS-HL H/L Special I MAI 4.99 1 33 TTS-HL
-3.05 TTS-HL Bobbin 23 27 NOI 11.54 P 1 14 TE-HL
+12.33 F/L H/L Special I MAI 4.32 1 24 TTS-HL
-9.19 TTS-HL H/L Tubesheet 23 48 SAI 0.75 1 19 TTS-HL
-2.41 TTS-HL H/L Tubesheet 23 64 SAI 0.31 1 40 TTS-HL
+0.00 TTS-HL H/L Tubesheet 23 73 SAI 1.17 1 24 TTS-HL
-0.08 TTS-HL Bobbin 23 102 ADI 7.26 6 77 6TH TSP
+33.18 F/L H/L Special I VOL 2.19 1 110 7TH TSP
-12.00 7TH TSP Bobbin 24 42 ADI 3.71 6 71 18TH TSP
+14.16 F/L C/L Special I VOL 0.64 1 103 17TH TSP
-8.36 17TH TSP Bobbin 24 58 IDI 45 22.76 P 1 14 TE-HL
+11.47 F/L H/L Special I MAI 1.39 1 33 TE-HL
+16.36 TTS-HL H/L Special I MAI 1.75 1 27 TE-HL
+13.09 TTS-HL H/L Special I MAI 3.51 1 18 TE-HL
+14.93 TTS-HL H/L Tubesheet 24 62 SAI 0.58 1 52 TTS-HL
-0.04 TTS-HL Bobbin 24 81 IDI 40 6.26 P 1 160 TE-HL
+3.22 F/L Bobbin 24 86 ODI 14 0.76 3 134 4TH TSP
+38.15 F/L H/L Special I VOL 0.36 1 146 STH TSP
-6.69 STH TSP Bobbin 24 88 ODI 27 0.81 3 123 STH TSP
+15.35 F/L H/L Special I VOL 1.55 1 128 STH TSP
+17.13 STH TSP Bobbin 24 102 NQI 0.48 3 108 STH TSP
+23.50 F/L H/L Special I VOL 0.90 1 161 STH TSP
+26.40 STH TSP Bobbin 24 103 NQI 3.35 P 1 16 TE-HL
+11.48 F/L H/L Tubesheet 25 18 VOL 0.42 1 156 TTS-HL
-0.25 TTS-HL Bobbin 25 22 NQI 14.59 P 1 165 TE-HL
+13.28 F/L H/L Tubesheet 25 24 SAI 1.40 1 20 TTS-HL
-4.21 TTS-HL Bobbin 25 25 ADI 4.17 6 69 STH TSP
+11.40 F/L H/L Special I VOL 5.11 1 23 STH TSP
+11.49 STH TSP Bobbin 25 60 WAR 7
0.34 P4 0 1AVB
+0.00 F/L Bobbin 25 62 ADI 1.99 6 48 6TH TSP
+29.39 F/L Bobbin ADI 2.84 6 75 6TH TSP 433.54 F/L Bobbin 25 67 ADI 3.16 6 30 1AVB
+0.23 F/L Bobbin 25 72 ADI 3.59 6 52 ISTH TSP
+6.31 F/L Bobbin NOI 0.51 3 109 18TH TSP
+18.54 F/L C/L Special I VOL 0.38 1 100 15TH TSP
+9.90 15TH TSP C/L Special I VOL 0.40 1 125 15TH TSP
+0.47 15TH TSP Bobbin 25 74 OD!
5 1.28 3 141 STH TSP
+16.37 F/L H/L Special I VOL 2.19 1 152 STH TSP
+16.63 STH TSP Bobbin 25 89 NQI 0.45 3 105 1BTH TSP
+6.14 F/L Bobbin 25 94 NQI 0.75 3 106 7TH TSP
+20.44 F/L
i BWHT TUBAN II (Varsion 2.1) 07/13/1995 13:57:02 McGuire Nuclear Station - Unit Two ce******
S/G C 12/94 RFO
{
Bobbin,C/L Special Interest,H/L Special Interest,H/L Tubesheet,U-Bend t
i Page 8 of 11 ATTACHMENT #3 - INDICATIONS OF IMPERFECTIONS i
INDS OF IMPERFECTIONS - SGC TEST TYPE ROW COL IND %TW VOLTS CHN DEG LOCATION EXTENT 1 l
Bobbin ODI 4
1.65 3 142 4TH TSP
+37.62 F/L Bobbin ODI 23 1.00 3 126 7TH TSP
+24.99 F/L Bobbin ODI 24 0.86 4 124 6TH TSP
+19.90 F/L Bobbin ODI 27 0.99 3 123 STH TSP
+24.08 F/L H/L Special I VOL 0.60 1 71 6TH TSP
+19.70 6TH TSP H/L Special I VOL 1.06 1 109 STH TSP
-6.71 STH TSP H/L Special I VOL 1.16 1 119 7TH TSP
+24.87 7TH TSP H/L Special I VOL 1.24 1 129 7TH TSP
+20.01 7TH TSP H/L Special I VOL 2.18 1 132 STH TSP
+24.00 STH TSP Bobbin 25 97 NOI 5.52 3 176 8TH TSP
+18.62 F/L U-Bend VOL 2.88 1 160 8TH TSP
+14.53 BTH TSP Bobbin 25 108 NQI 7.10 P 1 142 TTS-HL
-0.81 F/L Bobbin 26 8 NOI 0.46 3 59 16TH TSP
+7.05 F/L C/L Special I VOL 0.51 1 106 16TH TSP
+7.14 15TH TSP Bobbin 26 27 IDI 88 14.06 P 1 48 TE-HL
+15.26 F/L H/L Special I SAI 15.97 1 29 TTS-HL
-6.16 TTS-HL Bobbin 26 41 WAR 11 0.55 P 4 0 2AVB
+0.00 F/L H/L Tubesheet 26 42 SAI 2.63 1 20 TTS-HL
-3.94 TTS-HL Bobbin 26 49 WAR 10 0.50 P 4 0 2AVB
+0.00 F/L Bobbin 26 71 ADI 3.15 6 73 18TH TSP
+10.87 F/L C/L Special I VOL 0.14 1 125 18TH TSP
+10.82 1BTH TSP Bobbin 26 77 ADI 9.42 6 54 1AVB
+6.69 F/L U-Bend VOL 3.06 1 8 1AVB
+5.97 1AVB Bobbin 26 88 NOI 1.39 3 157 IST TSP
+13.73 F/L H/L Special I VOL 0.38 1 39 IST TSP
+14.78 IST TSP Bobbin 26 101 ODI 16 0.81 3 132 STH TSP
+5.69 F/L Bobbin ODI 19 0.61 4 135 STH TSP
+31.54 F/L H/L Special I VOL 0.65 1 44 STH TSP
+31.07 6TH TSP H/L Special I VCL 0.70 1 90 STH TSP
+5.49 6TH TSP Bobbin 27 32 WAR 19 1.10 P 4 0 3AVB
+0.00 F/L Bobbin 27 34 RAR 16 0.86 P 4 0 3AVB
+0.00 F/L H/L Tubesheet 27 38 VOL 0.41 1 155 TTS-HL
-0.48 TTS-HL H/L Tubesheet 27 58 SCI 0.39 3 62 TTS-HL
-0.40 TTS-HL Bobbin 27 94 ADI 5.88 6 47 7TH TSP
+17.09 F/L
(
H/L Special I VOL 0.83 1 136 7TH TSP
+17.34 7TH TSP Bobbin 28 13 IDI 64 7.74 P' 1 85 TE-HL
+15.24 F/L H/L Special I SAI 5.86 1 25 TTS-HL
-6.16 TTS-HL Bobbin 28 41 WAR 16 0.87 P 4 0 3AVB
+0.00 F/L Bobbin 28 56 NOI 1.45 3 145 19TH TSP
+5.05 F/L Bobbin 29 12 WAR 14 0.84 P 4 0 1AVB
+0.00 F/L Bobbin 29 14 NOI 3.17 3 19 13TH TSP
+13.60 F/L Bobbin 29 57 WAR 27 1.77 P 4 167 1AVB
+0.00 F/L Bobbin IDI 92 1.41 P 1 45 TE-HL
+15.34 F/L Bobbin 29 78 NOI 0.43 3 108 12TH TSP
+7.49 F/L Bobbin NOI 0.80 3 86 17TH TSP
+9.27 F/L C/L Special I VOL 0.90 1 121 12TH TSP
+8.39 12TH TSP C/L Special I VOL 0.97 1 109 16TH TSP
-1.05 16TH TSP Bobbin 29 87 WAR 11 0.66 P 4 0 1AVB
+0.00 F/L Bobbin 30 25 NQI 0.32 P 1 96 STH TSP
-0.18 F/L Bobbin 30 103 WAR 10 0.63 P 4 0 2AVB
+0.00 F/L Bobbin WAR 11 0.64 P 4 0 1AVB
+0.00 F/L H/L Tubesheet 31 15 SAI 0.51 1 24 TTS-HL
-1.26 TTS-HL Bobbin 31 65 WAR 18 1.20 P 4 0 1AVB
+0.00 F/L Bobbin 31 93 NOI 0.92 P 1 64 2ND TSP
+0.18 F/L H/L Special I VOL 0.89 1 84 2ND TSP
+0.16 2ND TSP Bobbin 31 98 WAR 14 0.84 P 4 0 2AVB
+0.00 F/L Bobbin 32 53 NOI 3.77 P 1 152 TTS-CL
-1.22 F/L Bobbin 32 63 ADI 4.64 6 64 10TH TSP
+3.32 F/L C/L Special I VOL 0.57 1 73 10TH TSP
+2.72 10TH TSP Bobbin 32 78 IDI 58 1.88 P 1 93 TE-HL
+5.75 F/L Bobbin 32 92 ODI 11 0.62 3 136 18TH TSP
+9.16 F/L l
C/L Special I VOL 0.58 1 114 18TH TSP
+9.18 18TH TSP Bobbin 32 93 NOI 0.50 3 72 2ND TSP
-1.27 F/L Bobbin ODI 14 0.33 3 132 11TH TSP
+36.11 F/L C/L Special I VOL 0.86 1 75 11TH TSP
+35.85 11TH TSP
l BWNT TUBAN II (Varcion 2.1) 07/13/1995 13:57:02 Co******
McGuirc Nuclear Station - Unit Two S/G C t
12/94 RFO Bobbin,C/L Special Interest,H/L Special Interest,H/L Tubesheet,U-Bend Page 9 of 11 ATTACHMENT #3 - INDICATIONS OF IMPERFECTIONS INDS OF IMPERFECTIONS - SGC TEST TYPE ROW COL IND %TW VOLTS CHN DEG LOCATION EXTENT 1 l
Bobbin 32 98 IDI 21 1.61 P 1 123 TE-HL
+10.55 F/L Bobbin
_33 12 WAR 8
0.38 P 4 0 1AVB
+0.00 F/L Bobbin WAR 13 0.62 P 4 0 4AVB
+0.00 F/L Bobbin WAR 19 1.02 P 4 0 2AVB
+0.00 F/L Bobbin WAR 25 1.50 P 4 0 3AV3
+0.00 F/L Bobbin 33 13 WAR 11 0.55 P 4 0 1AVB
+0.00 F/L Bobbin 33 45 NOI 2.22 P 1 46 TE-CL
+16.01 F/L Bobbin 33 48 WAR 10 0.49 P 4 0 1AVB
+0.00 F/L Bobbin 33 51 WAR 17 0.90 P 4 0 1AVB
+0.00 F/L i
Bobbin 33 73 ODI 18 2.87 4 128 6TH TSP
+36.96 F/L H/L Special I VOL 1.46 1 106 7TH TSP
-6.57 7TH TSP Bobbin 34 46 IDI 86 5.74 P1 59 TE-HL
+8.02 F/L Bobbin 34 48 WAR 9
0.45 P 4 0 1AVB
+0.00 F/L Bobbin 34 74 WAR 10 0.47 P 4 0 3AVB
+0.00 F/L Bobbin 34 85 WAR 13 0.66 P 4 0 1AVB
+0.00 F/L Bobbin 34 96 NQI 0.57 3 50 3RD TSP
+24.80 F/L H/L Special I VOL 1.24 1 127 4TH TSP
-19.20 4TH TSP Bobbin 35 33 WAR 18 0.97 P 4 0 3AVB
+0.00 F/L Bobbin 35 45 NOI 0.62 3 92 18TH TSP
+11.51 F/L C/L Special I VOL 0.56 1 93 18TH TSP
+12.04 18TH TSP Bobbin 35 89 NQI 0.32 3 62 3RD TSP
+30.29 F/L H/L S;-
.al I VOL 0.50 1 163 4TH TSP
-13.38 4TH TSP Bobbin 36 35 NOI 0.86 3 153 13TH TSP
+16,64 F/L C/L Special I VOL 0.36 1 44 12TH TSP
-6.24 12TH TSP Bobbin 36 40 NOI 0.31 3 62 16TH TSP
+7.12 F/L Bobbin 36 46 NOI 0.65 3 152 TTS-CL
+5.86 F/L Bobbin NQI 0.46 3 107 18TH TSP
+5.65 F/L C/L Special I VOL 0.98 1 112 TTS-CL
+4.93 22ND TSP C/L Special I VOL 0.64 1 87 18TH TSP
+5.45 18TH TSP Bobbin 36 49 WAR 22 1.51 P 4 0 1AVB
+0.00 F/L Bobbin WAR 25 1.89 P 4 0 2AVB
+0.00 F/L Bobbin 36 54 ODI 8
1.02 3 143 6TH TSP
+4.64 F/L H/L Special I VOL 0.64 1 126 6TH TSP
+4.47 6TH TSP Bobbin 36 67 ODI 90 1.29 P 1 47 3RD TSP
+0.05 F/L H/L Special I MAI 0.62 P 1 31 3RD TSP
-0.08 3RD TSP Bobbin 36 72 NQI 0.89 3 133 4TH TSP
+11.05 F/L Bobbin WAR 21 1.19 P 4 0 1AVB
+0.00 F/L Bobbin WAR 22 1.33 P 4 0 2AVB
+0.00 F/L H/L Special I VOL 1.80 1 139 4TH TSP
+12.01 4TH TSP Bobbin 36 88 WAR 12 0.60 P 4 0 2AVB
+0.00 F/L Bobbin 36 95 NQI 0.15 P 1 110 3RD TSP
-0.05 F/L Bobbin 37 29 ADI 3.27 6 67 7TH TSP
+23.85 F/L Bobbin ODI 14 0.41 3 136 7TH TSP
+35.82 F/L l
H/L Special I VOL 0.29 1 128 BTH TSP
-6.71 BTH TSP H/L Special I VOL 0.36 1 121 BTH TSP
-24.68 8TH TSP H/L Special I VOL 0.44 1 102 BTH TSP
-0.66 BTH TSP H/L Special I
~/OL 0.44 1 110 8TH TSP
-30.19 BTH TSP H/L Special I VOL 0.58 1 118 BTH TSP
-21.02 BTH TSP Bobbin 37 44 IDI 67 14.46 P 1 22'TE-HL
+14.18 F/L l
Bobbin 37 69 NOI 0.42 3 110 IST TSP
+14.99 F/L Bobbin ADI 2.44 6 62 15TH TSP
+2.50 F/L H/L Special I VOL 1.24 1 144 2ND TSP
-4.22 2ND TSP j
C/L Special I VOL 0.36 1 120 15TH TSP
+2.01 15TH TSP i
Bobbin 37 96 NOI 0.43 3 104 22ND TSP
+5.11 F/L Bobbin 37 99 ODI 14 1.92 3 135 10TH TSP
+8.62 F/L i
C/L Special I VOL 1.83 1 116 10TH TSP
+7.86 10TH TSP Bobbin 38 18 WAR 21 1.26 P 4 0 3AVB
+0.00 F/L Bobbin 38 22 WAR 19 1.07 P 4 0 1AVB
+0.00 F/L Bobbin 38 44 ADI 4.71 6 77 3RD TSP
+4.07 F/L Bobbin ADI 3.77 6 79 12TH TSP
+23.98 F/L H/L Special I VOL 1.22 1 137 3RD TSP
+4.21 3RD TSP C/L Special 1 VOL 1.22 1 114 12TH TSP
+23.73 12TH TSP Bobbin 38 46 WAR 13 0.63 P 4 0 1AVB
+0.00 F/L Bobbin 38 47 WAR 15 0.79 P 4 0 2AVB
+0.00 F/L Bobbin WAR 26 1.70 P 4 0 3AVB
+0.00 F/L
]
i 1
1 2;;;;;;:
BWNT TUBAN II (Version 2.1) 07/13/1995 13:57:02 McGuire Nuclesr Station - Unit Two eeee****
S/G C 12/94 RFO Bobbin,C/L Special Interest,H/L Special Interest,H/L Tubesheet,U-Bend 1
ATTACHMENT #3 - INDICATIONS OF IMPERFECTIONS INDS OF IMPERFECTIONS - SGC
-TEST TYPE ROW COL IND %TW VOLTS CHN DEG LOCATION EXTENT 1 Bobbin 38 70 WAR 14 0.77 P 4 0 1AVB
+0.00 F/L Bobbin 38 79 WAR 9
0.49 P 4 0 1AVB
+0.00 F/L Bobbin WAR 19 1.20 P 4 0 2AVB
+0.00 F/L Bobbin WAR 21 1.34 P 4 0 3AVB
+0.00 F/L Bobbin 38 88 ODI 8
0.63 3 140 3RD TSP
+15.80 F/L Bobbin NQI 0.37 P 1 52 2ND TSP 40.10 F/L H/L Special I VOL 0.29 1 104 3RD TSP
+5.30 3RD TSP H/L Special I VOL 0.38 1 106 3RD TSP
+7.60 3RD TSP H/L Special I VOL 0.50 1 99 3RD TSP
+12.66 3RD TSP H/L Special I VOL 0.72 1 121 3RD TSP
+15.91 3RD TSP H/L Special I SAI 0.24 P 1 122 2ND TSP
+0.02 2ND TSP Bobbin 39 27 WAR 15 0.80 P 4 0 1AVB
+0.00 F/L Bobbin 39 29 WAR 17 0.92 P 4 0 4AVB
+0.00 F/L Bobbin WAR 21 1.27 P 4 0 3AVB
+0.00 F/L Bobbin WAR 20 2.03 P 4 0 2AVB
+0.00 F/L Bobbin 39 31 WAR 16 0.86 P 4 0 2AVB
+0.00 F/L e
Bobbin 39 55 ADI 1.28 6 87 18TH TSP
+2.02 F/L Bobbin 39 72 ODI 15 1.63 3 133 TTS-CL
+1.66 F/L Bobbin 39 88 WAR 10 0.52 P 4 0 3AVB
+0.00 F/L Bobbin 40 19 WAR 13 0.68 P 4 0 1AVB
+0.00 F/L Bobbin 40 51 WAR 17 0.90 P 4 0 1AVB
+0.00 F/L Bobbin 40 62 WAR 29 1.70 P-4 0 1AVB
+0.00 F/L Bobbin 40 65 NQI 0.98 3 110 6TH TSP
+31.17 F/L H/L Special I VOL 1.99 1 136 7TH TSP
-13.09 7TH TSP Bobbin 40 96 NQI 0.56 P 1 55 STH TSP
+0.07 F/L Bobbin 41 43 NQI 2.60 P 1 158 TE-HL
+16.65 F/L Bobbin 41 44 ODI 32 1.01 3 118 4TH TSP
+4.10 F/L H/L Special I VOL 1.17 1 112 4TH TSP
+4.01 4TH TSP
'3 Bobbin 41 46 WAR 22 1.29 P 4 0 1AVB
+0.00 F/L Bobbin 41 50 ODI 7
1.47 3 138 13TH TSP
+19.84 F/L C/L Special I VOL 0.92 1 111 12TH TSP
-2.29 12TH TSP Bobbin 41 62 NOI 0.52 P 1 56 18TH TSP
+0.53 F/L Bobbin 41 73 ODI 8
0.82 3 140 19TH TSP
+2.44 F/L C/L Special I VOL 0.53 1 124 19TH TSP
+2.19 19TH TSP Bobbin 42 81 WAR 15 0.86 P 4 0 3AVB
+0.00 F/L Bobbin 42 83 WAR 14 0.76 P 4 0 2AVB
+0.00 F/L Bobbin 42 86 NQI 0.48 3 115 12TH TSP
+19.84 F/L Bobbin ODI 10 1.17 3 139 12TH TSP
+1.58 F/L C/L Special I VOL 0.49 1 Si 12TH TSP
+19.27 12TH TSP C/L Special I VOL 0.50 1 116 12TH TSP
+7.07 12TH TSP C/L Special I VOL 0.69 1 105.12TH TSP
+10.44 12TH TSP C/L Special I VOL 0.73 1 109 11TH TSP
+1.38 12TH TSP Bobbin 42 87 WAR 22 1.43 P 4 0 3hVB
+0.00 F/L Bobbin 42 91 WAR 23 1.46 P 4 0 ZAVB
+0.00 F/L Dobbin 43 35 ODI 12 0.54 3 114 7TH TSP
+2.67 F/L H/L Special I VOL 0.61 1 117 7TH TSP
+2.69 7TH TSP H/L Special I VOL 0.75 1 143 7TH TSP
+4.46 7TH TSP Bobbin 43 62 WAR 16 0.88 P 4 0 1AVB
+0.00 F/L Bobbin 43 64 WAR 30 2.34 P4 0 1AVB
+0.00 F/L Bobbin 43 82 WAR 17 0.96 P 4 0 1AVB
+0.00 F/L Bobbin 43 87 WAR 12 0.81 P 4 0 1AVB
+0.00 F/L Bobbin 43 93 NOI 0.38 3 108 7TH TSP
+9.57 F/L H/L Special I SA1 0.12 1 85 7TH TSP
+9.71 7TH TSP Bobbin 44 30 ODI 11 0.65 3 135 18TH TSP
+4.34 F/L C/L Special I VOL 0.70 1 101 18TH TSP
+1.54 18TH TSP C/L Special I VOL 0.87 1 103 18TH TSP
+4.45 18TH TSP Bobbin 44 38 ODI 9
0.99 3 136 13TH TSP
+5.46 F/L C/L Special I VOL 0.46 1 114 13TH TSP
+5.67 13TH TSP Bobbin 44 46 ADI 2.21 6 73 12TH TSP
+32.94 F/L C/L Special I VOL 0.92 1 114 11TH TSP
-11.37 11TH TSP Bobbin 44 53 ODI 10 1.38 4 138 IST TSP
+8.75 F/L H/L Special I VOL 0.54 1 123 IST TSP
+6.84 IST TSP H/L Special I VOL 0.70 1 118 IST TSP
+8.68 IST TSP Bobbin 44 64 NOI 2.52 3 17 TTS-HL
+2.98 F/L Bobbin 45 47 WAR 18 1.11 P 4 0 1AVB
+0.00 F/L
i i
f BWNT TUBAN II (Version 2.1) 07/13/1995 13:57:02 McGuire Nuclear Station - Unit Two S/G C 12/94 RFO Bobbin,C/L Special Interest,H/L Special Interest,H/L Tubesheet,U-Bend Page 11 of 11 ATTACHMENT #3 - INDICATIONS OF IMPERFECTIONS INDS OF IMPERFECTIONS - SGC TEST TYPE ROW COL IND %TW VOLTS CHN DEG LOCATION EXTENT 1 Bobbin 45 64 IDI 27 4.62 P 1 7 TTS-CL
+0.36 F/L Bobbin 45 87 NQI 0.93 P 1 43 3RD TSP
-0.05 F/L H/L Special I SAI 0.54 1 77 3RD TSP
+0.00 3RD TSP Bobbin 46 34 ADI 5.33 6 80 7TH TSP
+34.66 F/L H/L Special I VOL 0.66 1 133 BTH TSP
-9.25 BTH TSP Bobbin 46 44 ODI 4
1.56 3 140 10TH TSP
+15.00 F/L C/L Special I VOL 1.14 1 94 10TH TSP
+15.23 10TH TSP Bobbin 47 53 ADI 3.43 6 66 ISTH TSP
+6.98 F/L C/L Special I VOL 0.20 1 139 15TH TSP
+6.55 15TH TSP H/L Tubesheet 47 74 VOL 0.36 1 114 TTS-HL
-2.34 TTS-HL Bobbin 47 78 ODI 8
2.08 3 141 3RD TSP
+20.49 F/L H/L Special I VOL 0.68 1 114 3RD TSP
+20.81 3RD TSP Bobbin 48 48 NQI 0.23 P 1 107 6TH TSP
+0.10 F/L Bobbin 48 50 WAR 10 1.80 P 2 0 17TH TSP
+0.00 F/L Bobbin 48 70 WAR 4
0.75 P 2 0 16TH TSP
+0.00 F/L Bobbin 48 71 WAR 6
1.11 P 2 0 16TH TSP
+0.00 F/L Bobbin 49 51 WAR 15 2.77 P 2 0 17TH TSP
+0.00' F/L Bobbin 49 53 WAR 9
1.55 P 2 0 17TH TSP
+0.00 F/L C/L Special I VOL 1.41 P 1 160 17TH TSP
+0.00 17TH TSP Bobbin 49 55 NQI 0.39 P 1 84 STH TSP
-0.03 F/L Bobbin WAR 11 1.95 P 2 0 17TH TSP
+0.00 F/L Bobbin 49 59 ODI 25 0.93 3 126 13TH TSP
+14.45 F/L C/L Specir.1 I VOL 1.27 1 112 13TH TSP
+14.66 13TH TSP H/L Tubesheet 49 79 SAI 1.24 1 55 TTS-HL
+0.00 TTS-HL Total Indications Found = 674 Total Tubes Found = 344 i
}
BWNT TUBAN II (Varsion 2.1) 07/13/1995 14:03:21 McGuire Nuclear Station - Unit Two S/G D 12/94 RFO Bobbin,C/L Special Interest,H/L Special Interest,H/L Tubesheet,U-Bend Page 1 of 14 ATTACHMENT #4 - INDICATIONS OF IMPERFECTIONS INDS OF IMPERFECTIONS - SGD TEST TYPE-ROW COL IND %TW VOLTS CHN DEG LOCATION EXTENT 1 H/L Special I 1 12 VOL 1.24 1 121 STH TSP
-7.19 STH TSP Bobbin 2
6 ODI 14 0.71 4 120 TTS-CL
+3.54 9TH TSP Bobbin ADI 2.66 6 74 12TH TSP
+35.55 9TH TSP C/L Special I VOL 0.40 1 137 TTS-CL
+3.63 22ND TSP C/L Special I VOL 1.05 1 153 11TH TSP
-8.94 11TH TSP Bobbin 2 12 ODI 29 0.90 3 120 BTH TSP
+1.15 9TH TSP Bobbin 2 28 ADI 7.58 6 70 3RD TSP
+11.48 9TH TSP H/L Special I VOL 0.68 1 130 3RD TSP
+12.02 3RD TSP Bobbin 2 61 IDI 27 6.43 P 1 118 TE-HL
+14.58 9TH TSP Bobbin 2 103 NOI 0.42 3 110 19TH TSP
+18.65 9TH TSP C/L Special I VOL 0.69 1 15 19TH TSP
+18.73 14TH TSP Bobbin 3 12 NQI 0.98 3 56 22ND TSP
+1.76 9TH TSP Bobbin ODI 10 1.85 4 131 16TH TSP
+18.24 9TH TSP C/L Special I VOL 0.81 1 138 16TH TSP
+18.02 14TH TSP C/L Special I VOL 1.77 1 133 22ND TSP
+1.66 22ND TSP Bobbin 3 13 ODI 68 0.71 P 1 76 3RD TSP
-0.05 9TH TSP H/L Special I SAI 0.60 1 47 3RD TSP
-0.01 3RD TSP Bobbin 3 22 ODI 12 2.95 4 142 6TH TSP
+10.44 9TH TSP H/L Special I VOL 0.95 1 101 6TH TSP
+9.54 6TH TSP Bobbin 3 62 NQI 1.27 P 1 159 3RD TSP
+0.03 9TH TSP Bobbin 3 64 ODI 9
1.14 3 137 11TH TSP
+4.81 9TH TSP Bobbin ODI 13 0.98 3 133 11TH TSP
+3.39 9TH TSP Bobbin ODI 18 1.17 3 138 IST TSP
+5.34 9TH TSP H/L Special I VOL 1.06 1 133 IST TSP
+5.62 IST TSP C/L Special I VOL 0.50 1 49 11TH TSP
+4.89 11TH TSP C/L Special I VOL 0.80 1 129 11TH TSP
+3.57 11TH TSP Bobbin 3 75 ODI 14 0.89 4 127 19TH TSP
+27.06 9TH TSP C/L Special I VOL 0.43 1 130 19TH TSP
+26.37 14TH TSP Bobbin 3 83 ADI 2.40 6 58 10TH TSP
+10.75 9TH TSP C/L Special I VOL 0.36 1 144 10TH TSP
+10.66 10TH TSP Bobbin 3 87 ADI 3.62 6 62 16TH TSP
+12.08 9TH TSP Bobbin ADI 4.61 6 54 14TH TSP
+4.82 9TH TSP Bobbin ODI 3
1.07 4 139 10TH TSP
+19.09 9TH TSP Bobbin ODI 15 0.71 4 126 19TH TSP
+8.53 9TH TSP Bobbin ODI 25 1.01 4 115 10TH TSP
+4.39 9TH TSP C/L Special I VOL 0.51 1 112 19TH TSP
+8.61 19TH TSP C/L Special I VOL 0.54 1 55 16TH TSP
+12.02 16TH TSP C/L Special I VOL 0.57 1 136 10TH TSP
+19.35 10TH TSP C/L Special I VOL 0.58 1 125 10TH TSP
+4.13 10TH TSP C/L Special I VOL 0.92 1 130 14TH TSP
+4.79 14TH TSP H/L Tubesheet 3 91 SAI 0.79 1 28 TTS-HL
-0.11 TTS-HL H/L Tubesheet 3 103 VOL 0.36 1 129 TTS-HL
-0.51 TTS-HL Bobbin 4
4 ADI 2.16 6 60 10TH TSP
+33.85 9TH TSP C/L Special I VOL 0.73 1 30 9TH TSP
-10.74 9TH TSP Bobbin 4
7 ADI 6.08 6 82 6TH TSP
+24.68 9TH TSP Bobbin NQI 0.73 3 125 12TH TSP
+24.99 9TH TSP C/L Special I VOL 0.79 1 98 12TH TSP
+25.22 12TH TSP Bobbin 4 40 IDI 82 8.76 P 1 28 TE-HL
+1.56 9TH TSP U-Bend 4 46 VOL 1.16 1 108 BTH TSP
+13.69 8TH TSP U-Bend 4 4 8 VOL 1.19 1 23 8TH TSP
+14.60 BTH TSP U-Bend 4 4 9 VOL 1.18 1 62 9TH TSP
+6.26 BTH TSP Bobbin 4 61 NQI 5.78 P 1 157 TE-HL
+14.90 9TH TSP Bobbin 4 84 ODI 87 3.38 P 1 58 3RD TSP
-0.09 9TH TSP H/L Special I SAI 2.42 P 1 25 3RD TSP
-0.08 3RD TSP Bobbin 4 86 ODI 23 0.90 3 123 11TH TSP
+13.09 9TH TSP C/L Special I VOL 0.68 1 95 11TH TSP
+13.17 11TH TSP H/L Tubesheet 4 112 MAI 1.10 1 6 TTS-HL
+0.03 TTS-HL Bobbin 5
1 ODI 26 0.52 3 120 13TH TSP
+9.08 9TH TSP C/L Special I VOL 0.83 1 122 13TH TSP
+9.05 13TH TSP Bobbin 5 11 NQI 0.50 3 110 13TH TSP
+13.22 9TH TSP C/L Special I VOL 0.58 1 111 13TH TSP
+13.21 13TH TSP Bobbin 5 44 ODI 18 0.78 P 1 131 2ND TSP
+0.06 9TH TSP H/L Special I VOL 0.51 1 105 2ND TSP
+1.06 2ND TSP Bobbin 5 45 ADI 2.95 6 70 15TH TSP
+4.79 9TH TSP C/L Special I VOL 0.54 1 68 15TH TSP
+4.52 15TH TSP
BWNT TUBAN II (Version 2.1) 07/13/1995 14:03:21 McGuire Nuclear Station - Unit Two e*******
S/G D 12/94 RFO Bobbin,C/L Special Interest,H/L Special Interest,H/L Tubesheet,U-Bend Page 2 of 14 ATTACHMENT #4 - INDICATIONS OF IMPERFECTIONS INDS OF IMPERFECTIONS - SGD TEST TYPE ROW COL IND %TW VOLTS CHN DEG LOCATION EXTENT 1 Bobbin 5 52 ODI 17 0.42 3 129 18TH TSP
+16.27 9TH TSP C/L Special I VOL 0.43 1 120 17TH TSP
-5.49 17TH TSP Bobbin 5 56 ADI 1.11 6 59 19TH TSP
+2.13 9TH TSP Bobbin 5 62 ODI 15 0.78 3 131 13TH TSP
+16.66 9TH TSP Bcbbin ODI 30 0.80 4 113 18TH TSP
+9.81 9TH TSP C/L Special I VOL 0.54 1 114 1BTH TSP
+9.82 18TH TSP C/L Special I VOL 0.92 1 138 12TH TSP
-5.53 12TH TSP Bobbin 5 75 ODI 6
1.89 3 140 20TH TSP
+5.26 9TH TSP C/L Special I VOL 1.11 1 110 20TH TSP
+5.89 19TH TSP Bobbin 6
3 ADI 5.49 6 70 22ND TSP
+12.36 F/L C/L Special I VOL 0.82 1 98 22ND TSP
+12.08 22ND TSP Bobbin 6 10 NQI 0.52 3 119 18TH TSP
+20.32 F/L Bobbin NOI 0.99 3 142 11TH TSP
+14.59 F/L Bobbin NQI 1.05 3 130 15TH TSP
+7.98 F/L C/L Special I VOL 0.37 1 102 17TH TSP
-1.67 17TH TSP C/L Special I VOL 0.44 1 121 11TH TSP
+14.69 11TH TSP C/L Special I VOL 0.76 1 127 15TH TSP
+7.71 14TH TSP Bobbin 6 18 NQI 0.72 3 84 11TH TSP
+20.40 F/L C/L Special I VOL 1.28 1 124 11TH TSP
+20.30 11TH TSP Bobbin 6 34 ADI 3.05 6 47 17TH TSP
+5.93 F/L C/L Special I VOL 0.43 1 125 17TH TSP
+6.09.
16TH TSP Bobbin 6 44 ODI 11 0.62 3 136 22ND TSP
+5.23 F/L C/L Special I VOL 1.36 1 158 22ND TSP
+5.47 22ND TSP Bobbin 6 50 ADI 2.61 6 56 15TH TSP
+5.90 F/L C/L Special I VOL 1.03 1 166 15TH TSP
+5.61 14TH TSP Bobbin 6 55 NOI 0.38 P 1 58 2ND TSP
+0.12 F/L H/L Special I SAI 0.33 1 76 2ND TSP
-0.02 2ND TSP C/L Special I 6 59 NOI 0.72 1 27 9TH TSP
-2.75 9TH TSP Bobbin 6 64 NQI 6.25 P 1 166 TE-HL
+16.14 F/L H/L Tubesheet SAI 2.71 1 27 TTS-HL
-5.39 TTS-HL Bobbin 6 74 ODI 21 0.35 3 125 12TH TSP
+25.60 F/L I
C/L Special I VOL 0.42 1 95 12TH TSP
+25.47 12TH TSP Bobbin 6 92 NQI 0.73 3 99 6TH TSP
+31.47 F/L H/L Special I VOL 0.71 1 154 7TH TSP
-12.34 7TH TSP Bobbin 6 93 ODI 9
1.46 3 137 2ND TSP
+17.50 F/L H/L Special I VOL 1.04 1 108 3RD TSP
-7.13 3RD TSP Bobbin 6 99 ODI 10 4.40 P 1 130 TE-HL
+16.09 F/L H/L Special I MAI 3.72 P 1 6 TE-HL
+16.16 TTS-HL Bobbin 6 103 ODI 19 0.58 3 127 STH TSP
+6.07 F/L H/L Special I VOL 0.29 1 82 STH TSP
+6.62 STH TSP Bobbin 7 34 ODI 73 1.36 P 1 73 2ND TSP
+0.02 F/L H/L Special I MAI 1.11 1 50 2ND TSP
-0.02 2ND TSP Bobbin 7 72 IDI 91 54.56 P 1 30 TE-HL
+16.88 F/L H/L Tubesheet MAI 14.61 1 33 TTS-HL
-4.53 TTS-HL Bobbin 7 81 IDI 73 38.39 P 1 24 TE-HL
+4.02 F/L Bobbin 7 83 IDI 8
13.10 P 1 129 TE-HL
+5.14 F/L H/L Tubesheet MAI 1.23 1 19 TTS-HL
+0.03 TTS-HL Bobbin 7 91 ADI 6.99 6 63 STH TSP
+8.98 F/L H/L Tubesheet SAI 0.99 1 15 TTS-HL
+0.00 TTS-HL Bobbin 7 94 IDI 75 7.03 P 1 69 TE-HL
+16.10 F/L H/L Tubesheet SAI 6.93 1 32 TTS-HL
-5.44 TTS-HL H/L Tubesheet 7 97 SAI 0.27 1 47 TTS-HL
-3.49 TTS-HL Bobbin 7 107 ADI 4.93 6 68 4TH TSP
+14.25 F/L H/L Special I VOL 1.04 1 96 4TH TSP
+14.13 4TH TSP Bobbin 8
9 ADI 5.44 6 72 12TH TSP
+37.36 F/L C/L Special I VOL 0.99 1 133 11TH TSP
-7.26 11TH TSP Bobbin 8 41 NOI 0.73 P 1 58 3RD TSP
-0.05 F/L H/L Special I SAI 1.00 1 38 3RD TSP
-0.07 3RD TSP H/L Tubesheet 8 48 MAI 0.51 1 26 TTS-HL
-3.99 TTS-HL Bobbin 8 61 NQI 0.47 P 1 149 2ND TSP
-0.07 F/L H/L Special I SAI 0.12 P 1 93 2ND TSP
-0.09 2ND TSP Bobbin 8 66 ODI 75 0.66 P 1 69 2ND TSP
+0.00 F/L H/L Special I SAI 0.34 P1 63 2ND TSP
+0.00 2ND TSP Bobbin 8 81 ODI 3
1.29 3 141 13TH TSP
+7.76 F/L C/L Special I VOL 0.56 1 123 13TH TSP
+7.72 13TH TSP
BWNT TUBAN II (Version 2.1) 07/13/1995 14:03:21 McGuire Nuclear Station - Unit Two S/G D 12/94 RFO Bobbin,C/L Special Interest,H/L Special Interest,H/L Tubesheet,U-Bend Page 3 of 14 ATTACHMENT #4 - INDICATIONS OF IMPERFECTIONS INDS OF IMPERFECTIONS - SGD TEST TYPE ROW COL IND %TW VOLTS CHN DEG LOCATION EXTENT 1 Bobbin 8 84 IDI 82 11.43 P 1 60 TE-HL
+7.19 F/L Bobbin 8 86 NOI 0.47 P 1 67 2ND TSP
+0.05 F/L H/L Special I SAI 0.41 P 1 66 2ND TSP
+0.00 2ND TGP Bobbin 8 93 IDI 46 6.09 P 1 100 TE-HL
+13.53 F/L H/L Special I MAI 1.59 1 23 TTS-HL
-7.74 TTS-HL H/L Tubesheet 8 97 MAI 0.54 1 22 TTS-HL
-0.06 TTS-HL Bobbin 9
6 NQI 0.26 P 1 102 STH TSP
+0.17 F/L Bobbin 9 26 IDI 40 3.93 P 1 146 TE-HL
+5.04 F/L Bobbin 9 47 ODI 7
0.80 3 142 6TH TSP
+24.03 F/L H/L Special I VOL 0.35 1 84 6TH TSP
+23.36 6TH TSP Bobbin 9 51 NOI 3.78 3 10 12TH TSP
+24.27 F/L Bobbin 9 56 ODI 14 0.46 3 134 4TH TSP
+20.83 F/L Bobbin ODI 19 0.64 3 129 12TH TSP
+21.80 F/L H/L Special I VOL 0.35 1 128 4TH TSP
+20.83 4TH TSP C/L Special I VOL 0.64 1 20 12TH TSP
+21.88 12TH TSP Bobbin 9 75 NQI 26.01 P 1 162 TE-HL
+8.93 F/L H/L Special I MAI 3.67 P 1 11 TE-HL
+0.86 TTS-HL Bobbin 9 79 NQI 10.07 P 1 50 TE-HL
+13.90 F/L Bobbin NQI 23.17 P 1 161 TE-HL
+12.58 F/L H/L Tubesheet 9 84 SAI 0.97 1 35 TTS-HL
+0.00 TTS-HL Bobbin 9 85 ODI 80 1.00 P 1 65 2ND TSP
+0.05 F/L Bobbin IDI 92 4.12 P 1 34 TE-HL
+14.13 F/L H/L Special I MAI 0.52 P 1 57 2ND TSP
+0.00 2ND TSP Bobbin 9 86 ADI 2.37 6 46 13TH TSP
+17.14 F/L C/L Special I VOL 0.47 1 154 12TH TSP
-5.06 12TH TSP C/L Special I VOL 0.54 1 119 12TH TSP
-0.62 12TH TSP Bobbin 9 09 ODI 32 1.58 4 111 3RD TSP
+37.14 F/L H/L Special I VOL 0.93 1 115 4TH TSP
-6.80 4TH TSP Bobbin 9 90 NQI 0.88 3 111 8TH TSP
+18.42 F/L U-Bend VOL 0.86 1 152 BTH TSP
+18.31 9TH TSP Bobbin 9 112 ODI 28 1.62 3 117 13TH TSP
+11.32 F/L C/L Special I VOL 1.00 1 125 13TH TSP
+6.73 13TH TSP C/L Special I VOL 1.07 1 125 13TH TSP
+11.41 13TH TSP Bobbin 10 0 ODI 20 1.00 4 126 4TH TSP
+22.03 F/L H/L Special I VOL 0.38 1 141 4TH TSP
+21.41 4TH TSP H/L Special I 10 12 VOL 0.65 1 110 2ND TSP
+19.82 2ND TSP Bobbin 10 13 ODI 4
0.46 3 142 7TH TSP
+20.27 F/L H/L Special I VOL 0.16 1 83 7TH TSP
+19.24 7TH TSP Bobbin 10 33 ADI 5.93 6 69 11TH TSP
+40.66 F/L C/L Special I VOL 1.38 1 128 10TH TSP
-3.70 10TH TSP Bobbin 10 46 ODI 15 0.81 3 132 21ST TSP
+2.42 F/L C/L Special I VOL 0.54 1 45 21ST TSP
+2.59 20TH TSP Bobbin 10 49 ADI 3.71 6 83 21ST TSP
+2.52 F/L H/L Tubesheet 10 62 SAI 1.00 1 13 TTS-HL
+0.00 TTS-HL Bobbin 10 66 ODI 1
1.53 3 150 12TH TSP
+4.42 F/L Bobbin ODI 27 0.47 3 119 13TH TSP
+16.35 F/L C/L Special I VOL 0.41 1 108 12TH TSP
+4.66 12TH TSP C/L Special I VOL 0.62 1 30 12TH TSP
-6.65 12TH TSP Bobbin 10 67 ODI 28 0.75 3 118 3RD TSP
+35.59 F/L H/L Special I VOL 0,77 1 105 4TH TSP
-9.30 4TH TSP Bobbin 10 82 ODI 7
1.10 3 143 3RD TSP
+32.24 F/L Bobbin ODI 9
1.31 4 143 3RD TSP
+33.39 F/L Bobbin IDI 21 20.67 P 1 120 TE-HL
+9.82 F/L Bobbin IDI 68 21.80 P 1 21 TE-HL
+13.19 F/L H/L Special I VOL 0.49 1 63 4TH TSP
-11.76 4TH TSP H/L Special I VOL 0.69 1 38 4TH TSP
-10.24 4TH TSP Bobbin 10 87 IDI 11 5.21 P 1 129 TE-HL
+17.94 F/L J
H/L Tubesheet MAI 3.49 1 19 TTS-HL
-3.38 TTS-HL H/L Special I MAI 3.42 P 1 13 TE-HL 418.08 TTS-HL Bobbin 10 88 NOI 0.33 3 88 11TH TSP
+28.47 F/L C/L Special I VOL 0.99 1 167 11TH TSP
+27.82 11TH TSP i
Bobbin 10 91 NOI 1.01 3 58 10TH TSP
+31.70 F/ L l
C/L Special I VOL 0.99 1 116 9TH TSP
-11.66 9"'H TSP Bobbin 11 25 NOI 0.49 3 99 14TH TSP
+7.86 F 'L C/L Special I VOL 1.32 1 42 14TH TSP
+7.85 13TH TSP
-BWNT TUBAN II (Version 2.1) 07/13/1995 14:03:21 McGuire Nuclear Station - Unit Two S/G D 12/94 RFO Bobbin,C/L Special Interest,H/L Special Interest,H/L Tubesheet,U-Bend ATTACHMENT #4 - INDICATIONS OF IMPERFECTIONS INDS OF IMPERFECTIONS - SGD TEST TYPE ROW COL IND %TW VOLTS CHN DEG LOCATION EXTENT 1 Bobbin 11 34 NOI 0.47 3 80 10TH TSP
+40.67 F/L C/L Special I VOL 0.82 1 37 9TH TSP
-3.34 9TH TSP Bobbin 11 40 NQI 0.84 3 116 STH TSP
+24.29 F/L Bobbin NQI 1.28 3 95 12TH TSP
+14.10 F/L H/L Special I VOL 0.65 1 50 STH TSP
+24.29 STH TSP C/L Special I VOL 1.16 1 78 12TH TSP
+14.18 12TH TSP H/L Tubesheet 11 56 SAI 0.32 1 42 TTS-HL
-0.06 TTS-HL Bobbin 11 59 ODI 13 1.54 3 136 11TH TSP
+25.86 F/L C/L Special I VOL 0.22 1 108 11TH TSP
+27.98 10TH TSP C/L Special I VOL 1.04 1 109 11TH TSP
+25.35 10TH TSP Bobbin Il 94 NOI 1.60 P 1 48 TE-HL
+7.03 F/L Bobbin 11 107 ADI 4.85 6 58 TTS-CL
+1.82 F/L C/L Special I VOL 1.07 1 88 TTS-CL
+1.55 TTS-CL Bobbin 12 14 NOI 0.65 3 105 6TH TSP
+15.00 F/L H/L Special I VOL 0.16 1 70 6TH TSP
+14.62 6TH TSP Bobbin 12 22 NOI 4.27 P 1 22 TE-HL
+17.18 F/L Bobbin 12 53 NQI 0.31 3 113 21ST TSP
+2.29 F/L H/L Tubesheet 12 58 SAI 1.50 1 29 TTS-HL
+0.00 TTS-HL Bobbin 12 61 ODI 3
1,61 3 148 13TH TSP
+3.22 F/L C/L Special I VOL 1.01 1 142 13TH TSP
+3.51 13TH TSP Bobbin 12 68 NOI 0.87 P 1 40 2ND TSP
+0.05 F/L Bobbin 12 88 IDI 70 2.17 P 1 68 TE-HL
+17.08 F/L H/L Tubesheet SAI 3.80 1 28 TTS-HL
-4.90 TTS-HL Bobbin 12 110 ODI 34 0.57 3 111 17TH TSP
+9.46 F/L C/L Special I VOL 0.67 1 115 16TH TSP
-1.51 16TH TSP Bobbin 13 7 ODI 27 0.60 3 120 1BTH TSP
+15.36 F/L Bobbin ODI 28 0.30 3 119 18TH TSP
+13.22 F/L C/L Special I VOL 0.35 1 125 18TH TSP
+15.49 18TH TSP C/L Special I VOL 0.47 1 141 18TH TSP
+13.27 18TH TSP Bobbin 13 10 ODI 35 0.76 3 112 STH TSP
+19.66 F/L H/L Special I VOL 0.34 1 133 STH TSP
+18.71 STH TSP Bobbin 13 14 NQI 2.22 3 160 4AVB
-1.33 F/L Bobbin ADI 3.51 6 53 10TH TSP
+12.56 F/L C/L Special I VOL 0.56 1 119 10TH TSP
+12.58 10TH TSP Bobbin 13 20 NQI 0.40 P 1 82 2ND TSP
+0.00 F/L H/L Special I SAI 1.18 1 136 2ND TSP
-0.09 2ND TSP Bobbin 13 64 IDI 1
10.27 P 1 138 TE-HL
+16.03 F/L Bobbin 13 82 IDI 92 59.13 P 1 41 TE-HL
+5.61 F/L H/L Tubesheet 13 101 SAI 1.46 1 24 TTS-HL
+0.00 TTS-HL Bobbin 13 102 NOI 0.27 P 1 153 18TH TSP
+0.08 F/L Bobbin 14 53 ADI 3.61 6 54 22ND TSP
+10.09 F/L Bobbin 14 75 IDI 95 1.75 P 1 34 TE-HL
+10.54 F/L H/L Tubesheet 14 101 SAI 5.92 1 18 TTS-HL
-3.49 TTS-HL Bobbin 15 12 ODI 21 0.45 3 126 STH TSP
+34.69 F/L H/L Special I VOL 0.12 1 110 6TH TSP
-9.52 6TH TSP Bobbin 15 16 NOI 3.56 P 1 56 TE-CL
+8.04 F/L Bobbin 15 19 ODI 28 0.50 3 119 1BTH TSP
+9.75 F/L i
C/L Special I VOL 0.34 1 134 18TH TSP
+9.86 18TH TSP Bobbin 15 32 IDI 53 4.77 P 1 17 TE-HL
+9.06 F/L Bobbin 15 37 IDI 98 3.67 P 1 37 TE-HL
+15.04 F/L Bobbin 15 49 ODI 9
1.27 3 138 19TH TSP
+1.00 F/L Bobbin 15 55 ADI 7.03 6 71 7TH TSP
+13.91 F/L H/L Special I VOL 2.49 1 310 7TH TSP
+13.67 7TH TSP Bobbin 15 64 ADI 2.71 6 70 10TH TSP
+12.23 F/L Bobbin NOI 0.58 3 103 10TH TSP
+26.70 F/L Bobbin ODI 32 0.41 3 114 10TH TSP
+10.08 F/L C/L Special I VOL 0.52 1 133 10TH TSP
+10.06 10TH TSP C/L Special I VOL 0.68 1 129 10TH TSP
+11.80 10TH TSP C/L Special I VOL 0.69 1 88 10TH TSP
+26.65 10TH TSP Bobbin 15 75 ADI 3.03 6 75 4TH TSP
+33.88 F/L H/L Special I VOL 0.82 1 118 5TH TSP
-10.28 STH TSP Bobbin 15 95 ODI 15 0.70 3 131 18TH TSP
+6.61 F/L C/L Special I VOL 0.37 1 144 18TH TSP
+6.75 18TH TSP H/L Tubesheet 16 48 SAI 0.85 1 22 TTS-HL
-1.87 TTS-HL Bobbin 16 54 ODI 10 3.48 4 137 11TH TSP
+24.22 F/L i
BUNT TUBAN II (Version 2.1) 07/13/1995 14:03:21 McGuira Nuclear Station - Unit Two eeeee***
S/G D l
12/94 RFO Bobbin,C/L Special Interest,H/L Special Interest,H/L Tubesheet,U-Bend Page 5 of 14 ATTACHMENT #4 - INDICATIONS OF IMPERFECTIONS INDS OF IMPERFECTIONS - SGD TEST TYPE ROW COL IND %TW VOLTS CHN DEG LOCATION EXTENT 1 C/L Special I VOL 1.23 1 112 11TH TSP
+24.26 10TH TSP Bobbin 16 62 ODI 9
+5.85 F/L Bobbin ODI 14 1.13 3 132 IST TSP
+7.22 F/L Bobbin ODI 46 0.36 3 100 IST TSP
+9.51 F/L H/L Special I VOL 1.07 1 126 IST TSP
+8.88 IST TSP H/L Special I VOL 1.68 1 114 IST TSP
+5.64 IST TSP H/L Special I VOL 2.06 1 123 IST TSP
+6.74 1ST TSP Bobbin 16 80 NOI 0.33 P 1 53 3RD TSP
+0.09 F/L Bobbin 16 92 IDI 58 7.20 P 1 15 TE-HL
+15.57 F/L Bobbin IDI 81 16.25 P 1 21 TE-HL
+B.01 F/L Bobbin 16 99 NQI 7.35 P 1 163 TE-HL
+15.08 F/L Bobbin 17 5 ODI 9
1.49 3 138 STH TSP
+23.16 F/L Bobbin ODI 14 0.86 3 133 4TH TSP
+6.04 F/L H/L Special I SAI 0.52 1 59 4TH TSP
+5.68 4TH TSP H/L Special I VOL 0.47 1 84 STH TSP
+23.64 STH TSP H/L Special I VOL 0.65 1 130 STH TSP
+4.97 STH TSP Bobbin 17 23 ODI 18 1.14 3 129 10TH TSP
+11.22 F/L C/L Special I VOL 1,47 1 107 10TH TSP
+11.47 10TH TSP Bobbin 17 53 ADI 8.27 6 69 TTS-CL
+2.53 F/L C/L Special I VOL 1.21 1 103 TTS-CL
+2.39 22ND TSP Bobbin 17 89 ODI 13 1.06 3 131 3RD TSP
+21.07 F/L H/L Special I VOL 0.42 1 15 3RD TSP
+21.23 3RD TSP Bobbin 17 100 ADI 5.29 6 64 4TH TSP
+6.87 F/L H/L Special I VOL 0.92 1 71 4TH TSP
+6.82 4TH TSP Bobbin 17 102 ADI 3.72 6 57 18TH TSP
+7.88 F/L Bobbin ODI 7
1.00 3 136 13TH TSP
+18.85 F/L C/L Special I VOL 0.48 1 87 18TH TSP
+7.67 18TH TSP C/L Special I VOL 0.61 1 85 12TH TSP
-3.11 12TH TSP Bobbin 18 13 NOI 0.94 3 37 10TH TSP
+27.39 F/L C/L Special I VOL 0.95 1 120 10TH TSP
+26.81 9TH TSP Bobbin 18 23 NOI 0.53 3 94 20TH TSP
+2.50 F/L C/L Special I VOL 0.63 1 80 20TH TSP
+2.62 20TH TSP Bobbin 18 28 NOI 0.60 3 66 18TH TSP
+6.73 F/L C/L Special I VOL 0.77 1 111 18TH TSP
+6.98 18TH TSP Bobbin 18 36 NOI 0.42 3 73 9TH TSP
+1.75 F/L Bobbin NQI 0.66 3 40 3RD TSP
+36.89 F/L Bobbin NQI 0.59 3 29 10TH TSP
+41.84 F/L U-Bend VOL 0.58 1 81 9TH TSP
+2.47 9TH TSP C/L Special I VOL 1.37 1 156 QTH TSP
-2.38 9TH TSP H/L Special I VOL 1.21 1 157 4TH TSP
-6.48 4TH TSP Bobbin 18 44 NOI 2.27 P 1 48 TE-CL
+7.40 F/L Bobbin 18 55 NQI 0.78 3 66 18TH TSP
+19.11 F/L Bobbin ODI 18 0.59 3 129 7TH TSP
+23.68 F/L H/L Special I VOL 0.68 1 127 7TH TSP
+23.68 7TH TSP C/L Special I VOL 0.66 1 105 18TH TSP
+19.12 17TH TSP C/L Special I 18 63 NOI 1.19 1 25 11TH TSP
+2.20 11TH TSP Bobbin 18 70 NQI 0.34 3 108 2ND TSP
+9.26 F/L Bobbin ODI 17 1.20 3 128 19TH TSP
+1.63 F/L C/L Special I SAI 0.72 1 19 19TH TSP
+1.83 19TH TSP Bobbin 18 75 ODI 22 0.46 3 123 4TH TSP
+6.80 F/L Bobbin IDI 7
5.51 P 1 124 TE-HL
+6.49 F/L Bobbin 18 77 NOI 0.79 3 60 4TH TSP
+29.07 F/L H/L Special I VOL 0.17 1 125 4TH TSP
+29.07 4TH TSP Bobbin 18 104 ODI 25 1.45 3 120 3RD TSP
+16.88 F/L H/L Special I VOL 0.94 1 72 3RD TSP
+16.68 3RD TSP Bobbin 19 12 WAR 13 0.57 P 4 0 1AVB
+0.00 F/L Bobbin 19 20 ODI 10 1.19 3 136 12TH TSP
+25.22 F/L C/L Special I VOL 0.47 1 72 12TH TSP
+25.48 12TH TSP Bobbin 19 31 ADI 4.18 6 67 TTS-CL
+3.84 F/L Bobbin ADI 4.21 6 121 22ND TSP
+1.15 F/L C/L Special I VOL 0.88 1 171 TTS-CL
+3.99 TTS-HL C/L Special I VOL 1.03 1 131 22ND TSP
+1.35 22ND TSP Bobbin 19 41 ODI 34 0.83 3 113 7TH TSP
+21.60 F/L Bobbin 19 4 9 NOI 0.32 3 80 18TH TSP
+8.44 F/L C/L Special I VOL 0.34 1 101 18TH TSP
+8.69 17TH TSP
BWNT TUBAN II (Version 2.1) 07/13/1995 14:03:21 McGuiro Nuclear Station - Unit Two S/G D 12/94 RFO Bobbin,C/L Special Interest,H/L Special Interest,H/L Tubesheet,U-Bend Page 6 of 14 ATTACHMENT #4 - INDICATIONS OF IMPERFECTIONS INDS OF IMPERFECTIONS - SGD TEST TYPE ROW COL IND %TW VOLTS CHN DEG LOCATION EXTENT 1 Bobbin 19 57 NQI 0.66 3 56 10TH TSP
+29.45 F/L H/L Tubesheet 19 65 SAI 0.94 1 29 TTS-HL
+0.25 TTS-HL Bobbin 19 82 IDI 99 15.70 P 1 31 TE-HL
+3.75 F/L Bobbin 19 86 ADI 1.48 6 41 18TH TSP
+4.27 F/L Bobbin ODI 18 0.66 3 127 3RD TSP
+23.20 F/L H/L Special I VOL 0.32 1 53 4TH TSP
-20.66 4TH TSP Bobbin 20 9 NQI 0.79 3 111 13TH TSP
+12.04 F/L C/L Special I VOL 0.75 1 115 13TH TSP
+12.71 13TH TSP Bobbin 20 12 ADI 5.61 6 65 11TH TSP
+17.22 F/L C/L Special I VOL 0.87 1 78 11TH TSP
+17.16 11TH TSP Bobbin 20 58 IDI 52 10.36 P 1 16 TE-HL
+6.86 F/L Bobbin 20 59 NQI 3.48 P 1 42 TE-CL
+1.15 F/L Bobbin 20 60 NQI 0.85 3 79 STH TSP
+31.11 F/L H/L Special I VOL 0.77 1 86 6TH TSP
-13.93 6TH TSP H/L Tubesheet 20 74 SAI 0.75 1 16 TTS-HL
+0.05 TTS-HL Bobbin 20 76 NQI 0.64 3 112 10TH TSP
+9.57 F/L Bobbin NQI 1.11 3 159 12TH TSP
+2.18 F/L C/L Special I VOL 0.44 1 88 10TH TSP
+9.91 10TH TSP C/L Special I VOL 0.77 1 28 12TH TSP
+2.42 12TH TSP Bobbin 20 80 ADI 2.63 6 52 4TH TSP
+28.42 F/L H/L Special I VOL 0.97 1 128 STH TSP
-16.21 STH TSP Bobbin 20 84 ADI 2.60 6 61 2ND TSP
+10.14 F/L
{
H/L Spe91al I VOL 0.56 1 95 2ND TSP
+11.26 2ND TSP Bobbin 20 90 ADI 3.28 6 72 3RD TSP
+35.10 F/L H/L Special I VOL 0.57 1 164 4TH TSP
-8.75 4TH TSP H/L Tubesheet 20 100 SAI 0.10 1 26 TTS-HL
+0.03 TTS-HL Bobbin 20 102 ADI 3.87 6 88 4TH TSP
+35.09 F/L Bobbin 21 9 ODI 15 0.39 3 136 20TH TSP
-1.29 F/L C/L Special I VOL 0.47 1 123 20TH TSP
-1.61 20TH TSP Bobbin 21 22 NOI 0.63 3 75 21ST TSP
+5.30 F/L C/L Special I VOL 0.52 1 98 21ST TSP
+5.44 21ST TSP C/L Special I VOL 0.54 1 123 21ST TSP
+2.84 21ST TSP Bobbin 21 41 WAR 17 0.85 P 4 0 3AVB
+0.00 F/L Bobbin 21 52 ODI 17 0.36 P 1 131 4TH TSP
+0.31 F/L
{
Bobbin 21 56 IDI 96 21.97 P 1 34 TE-HL
+1.52 F/L H/L Tubesheet 21 67 MCI 1.17 1 59 TTS-HL
-0.08 TTS-HL H/L Tubesheet 21 78 SAI 0.72 1 43 TTS-HL
-0.05 TTS-HL Bobbin 21 83 ADI 10.11 6 34 9TH TSP
+9.28 F/L U-Bend VOL 1.73 1 132 9TH TSP
+9.08 9TH TSP Bobbin 21 86 NOI 0.51 3 108 11TH TSP
+17.56 F/L C/L Special I VOL 0.30 1 141 11TH TSP
+18.22 11TH TSP H/L Tubesheet 21 99 SAI 1.34 1 7 TTS-HL
+0.00 TTS-HL Bobbin 21 109 ADI 5.19 6 78 7TH TSP
+26.70 F/L H/L Special I VOL 0.86 1 113 7TH TSP
+26.89 7TH TSP Bobbin 22 56 ADI 2.89 6 56 3RD TSP
+32.21 F/L H/L Special I VOL 0.41 1 94 4TH TSP
-11.23 4TH TSP Bobbin 22 60 ODI 16 2.22 4 121 11TH TSP
+30.30 F/L C/L Special I VOL 0.35 1 69 10TH TSP
-14.71 10TH TSP Bobbin 22 67 NQI 3.62 P 1 144 TE-CL
+11.05 F/L H/L Tubesheet 22 71 SAI 1.01 1 20 TTS-HL
-5.36 TTS-HL Bobbin 22 77 ODI 30 0.46 3 118 13TH TSP
-1.24 F/L Bobbin NOI 27.65 P 1 167 TE-HL
+14.57 F/L H/L Tubesheet MA1 1.18 1 14 TTS-HL
-0.01 TTS-HL C/L Special I VOL 0.57 1 70 13TH TSP
-1.27 13TH TSP Bobbin 22 99 NOI 1.19 3 117 7TH TSP
+36.95 F/L Bobbin ODI 10 3.02 3 139 2ND TSP
+4.52 F/L H/L Special I VOL 0.84 1 112 BTH TSP
-7.01 8TH TSP H/L Special I VOL 1.83 1 130 2ND TSP
+4.72 2ND TSP Bobbin 22 105 ADI 13.82 6 51 8TH TSP
+11.48 F/L 1
U-Bend VOL 2.30 1 134 8TH TSP
+11.82 3AVB H/L Tubesheet 22 106 SAI 0.82 1 25 TTS-HL
-0.03 TTS-HL Bobbin 23 31 NOI 0.87 3 95 22ND TSP
+16.40 F/L i
C/L Special I VOL 0.75 1 70 21ST TSP
-3.99 21ST TSP j
Bobbin 23 36 ODI 5
1.91 4 134 7TH TSP
+41.90 F/L i
H/L Special I VOL 0.35 3 117 BTH TSP
-1.47 8TH TSP 1
l i
cococc**
BWNT TUBAN II (Varmion 2.1) 07/13/1995 14:03:21 l
ocooce*e McGuire Nuclear Station - Unit Two coococe*
S/G D occoce**
12/94 RFO
- o****
Bobbin,C/L Special Interest,H/L Special Interest,H/L Tubesheet,U-Bend j
Page 7 of 14 ATTACHMENT #4 - INDICATIONS OF IMPERFECTIONS INDS OF IMPERFECTIONS - SGD l
TEST TYPE ROW COL IND tTW VOLTS CHN DEG LOCATION EXTENT 1 Bobbin 23 89 ODI 14 0.86 4 123 10TH TSP
+17.26 F/L C/L Special I VOL 0.46 1 123 10TH TSP
+17.67 10TH TSP H/L Tubesheet 23 102 MAI 0.73 1 28 TTS-HL
-0.03 TTS-HL H/L Tubesheet 23 103 MAI 0.54 1 22 TTS-HL
+0.00 TTS-HL
)
Bobbin 23 104 IDI 97 9.36 P 1 30 TE-HL
+1.75 F/L Bobbin 24 20 ODI 13 1.24 4 129 IST TSP
+11.56 F/L l
H/L Special I VOL 0.71 1 276 IST TSP
+11.56 IST TSP H/L Tubesheet 24 57 SAI 0.54 1 33 TTS-HL
+0.00 TTS-HL l
Bobbin 24 72 ADI 4.64 6 95 STH TSP
+3.59 F/L l
H/L Special I VOL 3.72 1 136 STH TSP
+3.79 STH TSP j
Bobbin 25 42 ADI 3.18 6 70 7TH TSP
+3.58 F/L l
H/L Special I VOL 0.74 1 118 7TH TSP
+3.75 7TH TSP H/L Tubesheet 25 55 SAI 0.29 1 32 TTS-HL
+0.25 TTS-HL Bobbin 25 69 ODI 31 1.03 3 120 3RD TSP
+39.07 P/L H/L Special I VOL 1.38 1 136 4TH TSP
-6.14 4'."H TSP H/L Special I VOL 1.56 1 147 4TH TSP
-3.94 4TH TSP Bobbin 25 70 ADI 1.90 6 66 20TH TSP
+3.53 F/L Bobbin ADI 1.94 6 73 20TH TSP
+4.64 F/L C/L Special I VOL 0.37 1 152 20TH TSP
+1.12 20TH TSP l
C/L Special I VOL 0.45 1 132 20TH TSP
+4.68 20TH TSP l
C/L Special I VOL 0.53 1 121 20TH TSP
+3.35 20TH TSP Bobbin 25 78 NQI 0.72 3 95 4TH TSP
+11.30 F/L H/L Special I VOL 0.77 1 141 4TH TSP
+11.58 STH TSP Bobbin 25 94 IDI 42 9.00 P 1 13 TE-HL
+16.50 F/L Bobbin 26 39 IDI 97 37.29 P 1 31 TE-HL
+11.98 F/L H/L Tubecheet 26 57 SAI 1.03 1 30 TTS-HL
-3.07 TTS-HL Bobbin 26 61 IDI 70 8.72 P 1 21 TE-HL
+ 13 '. 5 2 F/L Bobbin 26 66 IDI 95 4.62 P 1 31 TE-HL
+3.71 F/L-Bobbin 26 84 WAR 18 1.02 P 4 0 1AVB
+0.00 F/L Bobbin 26 87 ADI 5.19 6 82 3RD TSP
+19.01 F/L H/L Special I VOL 1.29 1 122 3RD TSP
+19.14 3RD TSP Bobbin 26 94 NOI 2.71 P 1 24 TTS-CL
-1.24 F/L Bobbin 27 22 ODI 13 0.67 3 133 11TH TSP
+2.60 F/L C/L Special I VOL 0.82 1 148 11TH TSP
+2.68 11TH TSP t
Bobbin 27 57 NOI 0.40 P 1 52 4TH TSP
+0.05 F/L Bobbin 27 58 ODI 24 1.44 4 114 7TH TSP
+34.04 F/L H/L Special I VOL 1.15 1 124 BTH TSP
-10.79 8TH TSP Bobbin 27 71 IDI 62 13.49 P 1 18 TE-HL
+18.30
-F/L H/L Tubesheet MAI 4.80 1 16 TTS-HL
-3.25 TTS-HL H/L Special I MAI 5.92 1 17 TTS-HL
-3.22 TTS-HL Bobbin 27 76 ODI 27 0.86 3 120 11TH TSP
+28.29 F/L C/L Special I VOL 0.42 1 131 10TH TSP
-16.00 10TH TSP Bobbin 27 86 ODI 5
1.08 3 142 ISTH TSP
+3.15 F/L C/L Special I VOL 0.36 1 86 15TH TSP
+3.29 15TH TSP Bobbin 28 21 ADI 4.64 6 70 22ND TSP
+12.22 F/L C/L Special I VOL 0.74 1 126 22ND TSP
+12.15 22ND TSP Bobbin 28 70 IDI 48 9.23 P 1 15 TE-HL
+13.37 F/L Bobbin IDI 76 12.09 P 1 22 TE-HL
+17.15 F/L H/L Tubesheet MAI 4.38 1 20 TTS-HL
-4.35 TTS-HL Bobbin 28 75 NQI 0.27 3 81 10TH TSP
+13.46 F/L C/L Special I VOL 0.26 1 106 10TH TSP
+13.51 10TH TSP C/L Special I VOL 0.36 1 139 10TH TSP
+7.41 10TH TSP Bobbin 28 101 ODI 4
1.29 3 143 11TH TSP
+32.50 F/L C/L Special I VOL 0.48 1 95 10TH TSP
-11.85 10TH TSP H/L Tubesheet 28 106 SAI 0.68 1 15 TTS-HL
+0.18 TTS-HL Bobbin 29 39 ODI 19 1.91 4 118 10TH TSP
+22.60 F/L C/L Special I VOL 1.20 1 85 10TH TSP
+22.18 10TH TSP Bobbin 29 59 ADI 5.02 6 55 18TH TSP
+5.47 F/L C/L Special I VOL 1.28 1 123 18TH TSP
+5.39 18TH TSP Bobbin 29 61 IDI 7
8.41 P 1 129 TE-HL
+15.02 F/L Bcbbin 29 62 WAR 22 1.08 P 4 0 1AVB
+0.00 F/L Bobbin 29 67 WAR 17 0.75 P 4 0 1AVB
+0.00 F/L Bobbin 29 69 ADI 2.35 6 66 4TH TSP
+20.42 F/L H/L Special I VOL 0.40 1 118 4TH TSP
+21.61 4TH TSP Bobbin 29 72 ODI 30 0.87 3 117 3RD TSP
+29.75 F/L
BWNT TUBAN II (Version 2.1) 07/13/1995 14:03:21 McGuire Nuclear Station - Unit Two j
S/G D 12/94 RFO Bobbin,C/L Special Interest,H/L Special Interest,H/L Tubesheet,U-Bend l
Page 8 of 14 ATTACHMENT #4 - INDICATIONS OF IMPERFECTIONS INDS OF IMPERFECTIONS - SGD 4
TEST TYPE ROW COL IND %TW VOLTS CHN DEG LOCATION EXTENT 1 H/L Special I VOL 0.19 1 91 3RD TSP
+28.20 3RD TSP H/L Special I VOL 0.54 1 103 3RD TSP
+31.44 3RD TSP Bobbin 29 73 NQI 0.59 3 129 4TH TSP
+10.07 F/L H/L Special I VOL 1.25 1 162 4TH TSP
+10.89 4TH TSP Bobbin 29 -76 IDI 17 6.29 P 1 120 TE-HL
+15.91 F/L Bobbin 29 103 IDI 90 19.42 P 1 26 TE-HL
+18.35 F/L l
H/L Tubesheet MAI 1.42 1 39 TTS-HL
-3.13 TTS-HL H/L Special I MAI 2.70 1 25 TTS-HL
-3.07 TTS-HL Bobbin 30 24 ODI 14 1.81 4 123 17TH TSP
+8.47 F/L C/L Special I VOL 0.65 1 89 16TH TSP
-3.46 16TH TSP Bobbin 30 26 NQI 0.49 P 1 147 3RD TSP
-0.03 F/L Bobbin 30 27 NQI 0.48 P 1 132 3RD TSP
-0.08 F/L Bobbin 30 35 NQI 0.58 3 114 7TH TSP
+12.73 F/L H/L Special I VOL O.48 1 117 7TH TSP
+12.73 7TH TSP Bobbin 30 40 NOI 0.50 P 1 115 7TH TSP
+0.13 F/L Bobbin 30 41 NQI 0.30 P 1 111 STH TSP
+0.21 F/L H/L Tubesheet 30 49 SAI 1.28 1 27 TTS-HL
+0.08 TTS-HL H/L Tubesheet 30 54 SAI 0.67 1 22 TTS-HL
-2.74 TTS-HL Bobbin 30 60 ODI 17 1.20 4 121 3RD TSP
+4.10 F/L H/L Special I VOL 0.18 1 108 3RD TSP
+4.71 3RD TSP Bobbin 30 66 ODI 5
1.05 3 142 7TH TSP
+24.09 F/L H/L Special I VOL 0.21 1 149 7TH TSP
+25.21 7TH TSP Bobbin 30 88 IDI 69 12.79 P 1 20 TE-HL
+18.18 F/L H/L Tubesheet MAI 1.87 1 15 TTS-HL
-3.56 TTS-HL H/L Special I MAI 1.34 1 26 TTS-HL
-3.11 TTS-HL H/L Special I SAI 1.12 1 29 TTS-HL
-11.10 TTS-HL Bobbin 31 16 ODI 13 0.93 3 135 11TH TSP
+41.87 F/L C/L Special I VOL 0.92 1 116 10TH TSP
-2.25 10TH TSP Bobbin 31 38 WAR 24 1.48 P 4 0 3AVB
+0.00 F/L Bobbin 31 40 ODI 8
1.09 3 139 6TH TSP
+29.45 F/L H/L Special I VOL 1.22 1 135 6TH TSP
+28.12 6TH TSP Bobbin 31 42 ODI 2
0.94 3 145 18TH TSP
+5.72 F/L C/L Special I VOL 0.78 1 110 18TH TSP
+5.87 18TH TSP H/L Special I 31 49 VOL 1.70 1 101 GTH TSP
+12.70 6TH TSP Bobbin 31 79 NQI 0.59 3 115 18TH TSP
+3.61 F/L C/L Special I VOL 0.27 1 108 18TH TSP
+3.73 17TH TSP Bobbin 31 91 ODI 18 1.71 3 128 4TH TSP
+16.66 F/L H/L Special I VOL 1.37 1 105 4TH TSP
+17.02 4TH TSP Bobbin 31 104 ADI 1.96 6 67 10TH TSP
+6.87 F/L C/L Special I VOL 0.72 1 147 10TH TSP
+6.74 10TH TSP Bobbin 32 12 ODI 22 0.63 3 126 6TH TSP
+24.93 F/L H/L Special I VOL 0.41 1 101 6TH TSP
+24.93 6TH TSP Bobbin 32 17 ODI 18 0.39 3 128 12TH TSP
+38.28 F/L C/L Special I SAI 0.17 1 33 11TH TSP
-6.47 11TH TSP Bobbin 32 46 NQI 1.68 4 94 10TH TSP
+9.23 F/L Bobbin ODI 20 0.69 3 128 10TH TSP
+4.98 F/L C/L Special I VOL 0.76 1 137 10TH TSP
+5.02 10TH TSP C/L Special I VOL 1.17 1 129 10TH TSP
+8.93 10TH TSP Bobbin 32 59 NQI 11.60 P 1 162 TE-HL
+16.93 F/L H/L Tubesheet SAI-0.39 1 21 TTS-HL
-2.04 TTS-HL Bobbin 32 65 NOI 0.51 3 78 IST TSP
+16.72 F/L Bobbin ADI 2.67 6 71 11TH TSP
+37.03 F/L H/L Special I VOL 1.59 1 153 2ND TSP
-3.46 2ND TSP C/L Special I VOL 0.42 1 128 10TH TSP
-7.90 10TH TSP H/L Tubenheet 32 74 SAI 0.47 1 41 TTS-HL
-3.16 TTS-HL Bobbin 32 77 NQI 22.01 P 1 165 TE-HL
+8.70 F/L H/L Tubesheet SCI 0.21 1 124 TTS-HL
-0.02 TTS-HL Bobbin 32 83 ADI 5.34 6 69 12TH TSP
+20.87 F/L C/L Special I VOL 1.19 1 132 12TH TSP
+21.13 12TH TSP H/L Tubesheet 32 94 MAI 0.88 1 64 TTS-HL
-0.11 TTS-HL Bobbin 32 99 IDI 75 4.03 P 1 66 TE-HL
+11.01 F/L Bobbin 33 31 NQI 3.43 P 1 133 TTS-CL
-0.69 F/L Bobbin 33 59 ODI 7
3.41 4 128 10TH TSP
+20.24 F/L C/L Special I VOL 1.43 1 92 10TH TSP
+20.32 10TH TSP H/L Tubesheet 33 66 SAI O.99 1 18 TTS-HL
-0.03 TTS-HL
~
. ~_ -.+
l BWNT TUBAN II (Version 2.1) 07/13/1995'14:03:21 l
~
(**********
McGuire Nuclear Station - Unit Two 5
S/G D I
12/94 RFO i
Bobbin,C/L Special' Interest,H/L Special Interest,H/L Tubesheet,U-Bend I
t Page 9 of 14
. ATTACHMENT #4 - INDICATIONS OF IMPERFECTIONS
.INDS OF IMPERFECTIONS - SGD l
TEST TYPE ROW COL IND %TW VOLTS CHN DEG LOCATION EXTENT 1
\\
Bobbin R33
-75 WAR.19 0.64 P 4 0 3AVB
+0.00 F/L Bobbin.
33 79 ODI 13 1.49 4 125 7TH TSP
+31.62 F/L H/L'Special I VOL 0.23 1 102 8TH TSP.
-14.03 BTH TSP H/L Special I VOL 0.42 1 128 8TH TSP
-8.65 BTH TSP H/L Special I VOL 0.51 1 101 8TH TSP
-12.14 8TH TSP Bobbin 33 87 ADI 2.06 6 61 13TH TSP
+13.62 F/L
.C/L Special I VOL 0.53 1 119 12TH TSP
-9.68 12TH TSP Bobbin 33 88 ODI 2
+14.20 F/L t
Bobbin WAR 16 0.52 P 4 0 1AVB
+0.00 F/L i
H/L Special I VOL 1.11 1 129 IST TSP
+14.84 IST TSP Bobbin 33 89 NQI 0.37 3 93 12TH TSP
+25.22 F/L Bobbin 33 102 ADI 2.04 6 48 9TH TSP
+6.03 F/L Bobbin 34 27 WAR 27 1.82 P 4 0 3AVB
+0.00 F/L Bobbin 34 33 ODI 5
2.94 3 142 2ND TSP
+14.30 F/L H/L Special I VOL 0.76 1 131 2ND TSP
+14.30 2ND TSP
. Bobbin 34 40 ODI 17 1.53 4 136 13TH TSP
+2.26 F/L i
C/L Special I VOL 0.49 1 108 13TH TSP
+2.15 13TH TSP Bobbin 34 43 NOI 2.51 P 1 110 TTS-CL
-0.72 F/L.
Bobbin 34 44 NQI 0.80 3 114 9TH TSP
+5.10 F/L U-Bend VOL 0.99 1 150 9TH TSP
+6.20 9TH TSP Bobbin 34 46 NQI 1.46 3 42 3AVB
-5.74 F/L U-Bend VOL 1.03 1 163 3AVB
-5.86 9TH TSP C/L Special I 34 61 NQI 0.53 1 33 21ST TSP
+4.67 21ST TSP Bobbin 34 63 ADI 4.30 6 75 11TH TSP
+2.54 F/L Bobbin ADI 4.38 6 78 11TH TSP
+5.56 F/L C/L Special I VOL 0.77 1 90 11TH TSP
+2.26 11TH TSP C/L Special I VOL 1.09 1 116 11TH TSP
+5.66 11TH TSP i
Bobbin 34 70 NOI 8.76 P 1 164 TE-HL-
+13.99 F/L H/L Special I MAI 3.95 1 24 TE-HL
+14.12 TTS-HL Bobbin 34 78 ADI 1.82 6 57 10TH TSP
+16.06 F/L
't C/L Special I VOL 0.63 1 102 10TH TSP
+16.42 10TH TSP Bobbin 34 88 ODI 21 1.08 4 118.3RD TSP
+18.73 F/L
~
Bobbin 34 90 ODI 7
0.80 3 139 STH TSP
+17.70 F/L.
H/L Special I VOL 0.52 1 145 STH TSP
+17.55 6TH TSP' Bobbin 34 94 ODI 5
1.41 4 129 12TH TSP
+39.45 F/L C/L Special I VOL 0.28 1 131 11TH TSP
-4.82 11TH. TSP Bobbin 35 18 WAR 18 0.98 P 4 0 1AVB
+0.00 F/L Bobbin 35 39 WAR 19 1.05 P 4 0 4AVB
+0.00 F/L Bobbin' 35 40 ODI 2
0.52 3 143 3RD TSP
+2.81 F/L Bobbin WAR 26 1.68 P 4 0 2AVB
+0.00 F/L H/L Special I VOL Os72 1 134 3RD TSP
+3.15 3RD TSP i
t Bobbin 35 51 ODI 7
1.26 3 139 8TH TSP
+29.13 F/L Bobbin WAR 15 0.82 P 4 0 1AVB-
+0.00 F/L Bobbin.
35 72 ADI 6.79 6 59 22ND TSP
+10.04 F/L i
C/L Special I VOL 0.60 1 94 22ND TSP
+9.92 22ND TSP t
Bobbin 35 76 ODI 7
0.89 3 137 STH TSP
+31.99 F/L f
H/L Special I VOL 0.56 1 125 6TH TSP
-12.30 6TH TSP Bobbin 35 91 ADI 4.14 6 62 3RD TSP
+33.22 F/L H/L Special I VOL 0.59 1 72 4TH TSP
-10.06 4TH TSP Bobbin.
36 18 WAR 17 0.95 P 4 0 1AVB
+0.00 F/L Bobbin WAR 17 0.95 P 4 0 1AVB
+0.00 F/L Bobbin WAR 17 0.95 P 4 0 1AVB
+0.00 F/L
' Bobbin WAR 17 0.95 P 4 0 1AVB
+0.00 F/L I
Bobbin WAR 17 0.95 P 4 0 1AVB
+0.00 F/L Bobbin WAR 17 0.95 P 4 0 1AVB
+0.00 F/L Bobbin
. 36 21 NOI 0.35 3 88 15TH TSP
+1.43 F/L i
C/L Special I VOL 0.39 1 53 15TH TSP
+1.78 15TH TSP Bobbin 36 26 ODI 6
0.72 3 140 7TH TSP
+18.94 F/L Bobbin ODI 6
0.89 4 138 6TH TSP
+15.74 F/L Bobbin 36 39 ADI 3.85 6 67 12TH TSP
+34.14 F/L Bobbin ODI 11 0.74 3 135 11TH TSP
+5.98 F/L Bobbin NQI 2.80 P 1 19 TE-HL
+17.32 F/L-Bobbin WAR 21 1.18 P 4 0 2AVB
+0.00 F/L C/L Special I VOL 0.72 1 106 11TH TSP
-10.17 11TH TSP l
C/L Special I VOL 0.99 1 105 11TH TSP
+6.58 11TH TSP
00******
BWNT TUBAN II (Varsion 2.1) 07/13/1995 14:03:21 McGuire Nuclear Station - Unit Two S/G D o*******
12/94 RFO Bobbin,C/L Special Interest,H/L Special Interest,H/L Tubesheet,U-Bend ATTACHMENT #4 - INDICATIONS OF IMPERFECTIONS INDS OF IMPERFECTIONS - SGD TEST TYPE ROW COL IND %TW VOLTS CHN DEG LOCATION EXTENT 1 Bobbin 36 49 WAR 9
0.54 P 4 0 2AVB
+0.00 F/L Bobbin WAR 18 1.02 P 4 0 1AVB
+0.00 F/L Bobbin 36 51 ODI 25 1.48 3 121 8TH TSP
+29.33 F/L Bobbin 36 53 ODI 16 0.98 3 130 11TH TSP
+5.17 F/L Bobbin WAR 20 1.13 P 4 0 1AVB
+0.00 F/L C/L Special I VOL 1.30 1 139 11TH TSP
+5.33 11TH TSP C/L Special I 36 67 NOI 1.24 1 20 10TH TSP
+10.99 10TH TSP Bobbin 36 83 NQI 3.36 3 164 4AVB
-1.60 F/L U-Bend VOL 2.52 1 163 4AVB
-1.96 9TH TSP Bobbin 36 100 ADI 3.46 6 57 12TH TSP
+33.20 F/L C/L Special I VOL 0.49 1 108 11TH TSP
-11.17 11TH TSP Bobbin 37 20 WAR 14 0.64 P4 0 2AVB
+0.00 F/L Bobbin 37 23 ODI 6
1.49 4 133 3RD TSP
+16.55 F/L H/L Special I VOL 0.34 1 68 3RD TSP
+12.20 3RD TSP H/L Special I VOL 0.66 1 123 3RD TSP
+13.86 3RD TSP H/L Special I VOL 1.13 1 142 3RD TSP
+16.58 3RD TSP Bobbin 37 29 ADI 5.57 6 66 18TH TSP
+15.13 F/L C/L Special I VOL 1.07 1 106 17TH TSP
-7.45 17TH TSP Bobbin 37 35 WAR 17 0.84 P4 0 3AVB
+0.00 F/L Bobbin 37 37 ODI 2
1.37 4 136 20TH TSP
+3.58 F/L C/L Special I VOL 0.86 1 119 20TH TSP
+3.31 20TH TSP Bobbin 37 40 ODI 26 0.64 3 121 12TH TSP
+20.01 F/L C/L Special I VOL 0.58 1 82 12TH TSP
+19.68 11TH TSP Bobbin 37 42 WAR 17 0.80 P 4 0 2AVB
+0.00 F/L Bobbin 37 46 ADI 2.69 6 60 12TH TSP
+8.21 F/L Bobbin ADI 5.65 6 56 14TH TSP
+4.26 F/L Bobbin ODI 6
3.84 4 133 18TH TSP
+11.53 F/L Bobbin WAR 19 0.97 P 4 0 1AVB
+0.00 F/L C/L Special I VOL 0.50 1 125 12TH TSP
+7.95 12TH TSP C/L Special I VOL 1.29 1 101 18TH TSP
+11.51 18TH TSP C/L Special I VOL 1.29 1 116 14TH TSP
+4.52 14TH TSP Bobbin 37 47 NQI 0.37 3 88 7TH TSP
+38.67 F/L Bobbin ADI 2.52 6 71 13TH TSP
+8.53 F/L Bobbin ODI 10 1.49 4 130 7TH TSP
+35.99 F/L H/L Special I VOL 0.66 1 114 8TH TSP
-8.24 BTH TSP H/L Special I VOL 0.75 1 141 BTH TSP
-5.36 BTH TSP
]
C/L Special I VOL 0.53 1 113 13TH TSP
+8.86 13TH TSP Bobbin 37 48 IDI 18 2.58 P 1 123 TTS-CL
-1.04 F/L Bobbin 37 54 WAR 16 0.84 P 4 0 4AVB
+0.00 F/L Bobbin WAR 19 0.93 P 4 0 3AVB
+0.00 F/L Bobbin WAR 22 1.34 P 4 0 1AVB
+0.00 F/L Bobbin 37 55 NOI 3.55 P 1 30 TE-CL
+15.09 F/L Bobbin 37 68 NOI 0.52 P 1 150 STH TSP
-0.32 F/L Bobbin 37 74 NQI 0.44 3 95 STH TSP
+33.89 F/L H/L Special I VOL 0.29 1 142 6TH TSP
-10.30 6TH TSP Bobbin 37 75 ADI 2.28 6 69 6TH TSP
+10.55 F/L H/L Special 1 VOL 0.01 1 158 6TH TSP
+10.55 6TH TSP Bobbin 37 82 WAR 15 0.59 P 4 0 3AVB
+0.00 F/L Bobbin 37 84 ADI 2.60 6 70 STH TSP
+12.00 F/L H/L Special I VOL 0.72 1 133 STH TSP
+12.43 STH TSP Bobbin 37 89 WAR 27 1.52 P 4 0 2AVB
+0.00 F/L Bobbin 37 94 NQI 2.82 P 1 39 TE-CL
+19.08 F/L Bobbin NQI 2.12 P 1 13b TTS-CL
-0.76 F/L Bobbin 38 35 ODI 1
1.63 3 146 19TH TSP
+4.69 F/L C/L Special I VOL 0.83 1 102 19TH TSP
+5.30 19TH TSP Bobbin 38 38 WAR 22 1.15 P 4 0 3AVB
+0.00 F/L Bobbin 38 40 ODI 10 1.18 3 137 11TH TSP
+37.10 F/L C/L Special I VOL 1.02 1 130 10TH TSP
-7.26 10TH TSP Bobbin 38 43 WAR 17 0.80 P 4 0 1AVB
+0.00 F/L Bobbin 38 46 WAR 16 0.72 P 4 0 1AVB
+0.00 F/L Bobbin 38 49 WAR 16 0.77 P 4 0 1AVB
+0.00 F/L Bobbin WAR 17 0.79 P 4 0 2AVB
+0.00 F/L Dobbin WAR 23 1.30 P 4 0 3AVB
+0.00 F/L i
Bobbin 38 50 WAR 15 0.70 P 4 0 1AVB
+0.00 F/L Bobbin 38 51 WAR 20 1.01 P 4 0 1AVB
+0.00 F/L i
BWNT TUBAN II (Version 2.1) 07/13/1995 14:03:21 McGuire Nuclear Station - Unit Two eoe*****
S/G D 12/94 RFO Bobbin,C/L Special Interest,H/L Special Interest,H/L Tubesheet,U-Bend Page 11 of 14 ATTACHMENT #4 - INDICATIONS OF IMPERFECTIONS
,INDS OF IMPERFECTIONS - SGD TEST TYPE ROW COL IND %TW VOLTS CHN DEG LOCATION EXTENT 1 Bobbin 38 56 IDI 88 14.44 P 1 52 TE-HL
+16.08 F/L H/L Special I MAI 5.18 1 206 TTS-HL
-5.35 TTS-HL Bobbin 38 57 ADI
'5.78 6 66 STH TSP
+8.54 F/L U-Bend VOL 1.07 1 59 8TH TSP
+8.98 8TH TSP Bobbin 38 59 WAR 18 0.76 P 4 0 2AVB
+0.00 F/L Bobbin 38 63 WAR 28 1.81 P 4 0 1AVB
+0.00 F/L Bobbin WAR 28 1.86 P 4 0 2AVB
+0.00 F/L Bobbin 38 68 ODI 14 0.76 3 131 22ND TSP
+2.99 F/L C/L Special I VOL 0.69 1 107 22ND TSP
+2.87 22ND TSP Bobbin 38 70 ODI 16 0.82 3 129 11TH TSP
+32.86 F/L C/L Special I VOL 0.67 1 127 10TH TSP
-11.76 10TH TSP H/L Tubesheet 38 73 SAI 0.77 1 10 TTS-HL
-0.08 TTS-HL Bobbin 38 85 ADI 2.51 6 54 3RD TSP
+10.88 F/L Bobbin ADI 2.88 6 67 3RD TSP
+18.65 F/L Bobbin 38 90 NOI 0.49 3 78 15TH TSP
+3.74 F/L C/L Special I VOL 0.50 1 113 15TH TSP
+3.83 15TH TSP Bobbin 39 20 ADI 3.42 6 70 12TH TSP
+12.55 F/L Bobbin WAR 16 0.72 P 4 0 2AVB
+0.00 F/L C/L Special I VOL 0.64 1 124 12TH TSP
+13.12 12TH TSP Bobbin 39 29 ADI 4.84 6 66 10TH TSP
+8.27 F/L C/L Special I VOL 0.87 1 117 10TH TSP
+8.72 10TH TSP Bobbin 39 33 ADI 5.69 6 60 13TH TSP
+16.93 F/L j
C/L Special I VOL 0.69 1 134 12TH TSP
-6.25 12TH TSP Bobbin 39 36 WAR 11 0.47 P 4 0 3AVB
+0.00 F/L Bobbin 39 42 ODI 6
1.50 4 133 14TH TSP
+4.32 F/L Bobbin ODI 9
1.50 4 131 11TH TSP
+11.03 F/L C/L Special I VOL 0.78 1 47 11TH TSP
+11.95 11TH TSP C/L Special I VOL 1.24 1 139 14TH TSP
+4.69 14TH TSP Bobbin 39 50 ODI 6
1.92 4 136 13TH TSP
+2.40 F/L Bobbin WAR 21 1.09 P 4 0 1AVB
+0.00 F/L C/L Special I VOL 1.23 1 118 13TH TSP
+2.39 13TH TSP Bobbin 39 67 ODI 15 1.01 3 130 6TH TSP
+34.68 F/L H/L Special I VOL 1.09 1 143 7TH TSP
-9.57 7TH TSP Bobbin 39 74 ADI 4.92 6 67 11TH TSP
+26.81 F/L t
C/L Special I VOL 1.07 1 141 11TH TSP
+26.60 11TH TSP H/L Tubesheet 39 84 MAI 0.36 2 14 TTS-HL
-1.06 TTS-HL Bobbin 39 90 NQI 0.44 3 97 STH TSP
+27.87 F/L Bobbin 39 91 NQI 2.55 P 1 150 TE-HL
+15.08 F/L Bobbin 39 96 NQI 1.14 3 104 4TH TSP
+34.80 F/L H/L Special I VOL 1.01 1 107 STH TSP
-9.98 STH TSP Bobbin 40 51 NQI 0.42 3 77 11TH TSP
+24.27 F/L C/L Special I VOL 0.78 1 57 11TH TSP
+24.55 11TH TSP Bobbin 40 74 ADI 3.84 6 63 22ND TSP
+11.11 F/L Bobbin ODI 8
+18.33 F/L H/L Special I VOL 1.35 1 23 2ND TSP
-0.21 2ND TSP H/L Special I VOL 1.42 1 195 2ND TSP
-2.29 2ND TSP C/L Special I VOL 0.99 1 124 22ND TSP
+10.99 22ND TSP Bobbin 40 79 IDI 72 3.09 P 1 26 TE-HL
+13.59 F/L Bobbin IDI 99 12.26 P 1 38 TE-HL
+17.33 F/L H/L Tubesheet 40 84 MAI 0.19 1 15 TTS-HL
-1.20 TTS-HL Bobbin 41 38 WAR 15 0.75 P 4 0 1AVB
+0.00 F/L Bobbin 41 41 NOI 1.82 P 1 36 TE-CL
+12.12 F/L H/L Tubesheet SAI 2.32 1 18 TTS-HL
-1.94 TTS-HL Bobbin 41 83 WAR 19 0.76 P 4 0 1AVB
+0.00 F/L Bobbin 42 23 WAR 20 1.26 P 4 0 3AVB
+0.00 F/L Bobbin 42 30 NOI 1.31 3 48 13TH TSP
+18.63 F/L C/L Special I VOL 1.38 1 111 12TH TSP
-3.92 12TH TSP Bobbin 42 31 ADI 3.20 6 52 12TH TSP
+5.07 F/L C/L Special I VOL 0.64 1 120 12TH TSP
+5.29 12TH TSP Bobbin 42 34 WAR 8
0.47 P 4 0 1AVB
+0.00 F/L Bobbin WAR 10 0.59 P 4 0 2AVB
+0.00 F/L Bobbin WAR 13 0.72 P 4 0 3AVB
+0.00 F/L Bobbin WAR 15 0.87 P 4 0 4AVB
+0.00 F/L Bobbin 42 35 WAR 17 1.03 P 4 0 1AVB
+0.00 F/L Bobbin 42 36 WAR 18 1.06 P 4 0 1AVB
+0.00 F/L
e*******
BWNT 11HUui II (Varaion 2.1) 07/13/1995 14:03:21
- e******
McGuire Nuclear Station - Unit Two S/G D 12/94 RFO Bobbin,C/L Special Interest,H/L Special Interest,H/L Tubesheet,U-Bend Page 12 Of 14 ATTACHMENT #4 - INDICATIONS OF IMPERFECTIONS INDS OF IMPERFECTIONS - SGD TEST TYPE ROW COL IND %TW VOLTS CHN DEG LOCATION EXTENT 1 Bobbin 42 37 WAR 10 0.58 P 4 0 2AVB
+0.00 F/L Bobbin 42 40 WAR 11 0.63 P 4 0 1AVB
+0.00 F/L Bobbin 42 43 NOI 0.81 3 121 13TH TSP
+17.84 F/L Bobbin WAR 24 1.48 P 4 0 1AVB
+0.00 F/L C/L Special I VOL 0.75 1 99 12TH TSP
-4.47 12TH TSP Bobbin 42 45 WAR 19 0.99 P 4 0 1AVB
+0.00 F/L Bobbin 42 49 ODI 4
1,69 3 141 18TH TSP
+5.51 F/L Bobbin IDI 92 1.72 P 1 48 TE-HL
+14.65 F/L C/L Special I VOL 1.37 1 98 18TH TSP
+5.80 18TH TSP Bobbin 42 53 WAR 13 0.76 P 4 0 2AVB
+0.00 F/L Bobbin WAR 23 1.51 P 4 0 1AVB
+0.00 F/L Bobbin 42 61 ODI 17 1.09 3 130 8TH TSP
+19.31 F/L Bobbin NQI 0.24 P 1 105 17TH TSP
-0.35 F/L U-Bend VOL 1.30 1 131 BTH TSP
+20.70 8TH TSP Bobbin 42 71 IDI 91 3.48 P 1 32 TE-HL
+11.60 F/L Bobbin 42 73 IDI 75 14.26 P 1 64 TE-HL
+16.95 F/L H/L Special I MAI 7.40 1 33 TTS-HL 04.57 TTS-HL Bobbin 43 31 WAR 13 0.59 P 4 0 3AVB
+0.00 F/L Bobbin 43 33 NOI 3.84 P 1 20 TE-CL
+19.06 F/L Bobbin 43 37 ODI 6
0.47 3 143 13TH TSP
+1.84 F/L Bobbin ODI 16 0.52 3 132 15TH TSP
+18.36 F/L Bobbin WAR 14 0.62 P 4 0 3AVB
+0.00 F/L Bobbin WAR 7
1.47 P2 0 17TH TSP
+0.00 F/L C/L Special I VOL 0.37 1 140 13TH TSP
+2.10 13TH TSP C/L Special I VOL 0.42 1 122 13TH TSP
-4.14 13TH TSP Bobbin 43 43 WAR 17 0.98 P 4 0 3AVB
+0.00 F/L Bobbin 43 52 WAR 12 0.71 P 4 0 2AVB
+0.00 F/L Bobbin 43 54 WAR 12 0.71 P 4 0 1AVB
+0.00 F/L Bobbin 43 55 WAR 17 1.00 P 4 0 1AVB
+0.00 F/L Bobbin ODI 14 0.51 P 1 118 17TH TSP
-0.28 F/L C/L Special I VOL 0.79 1 133 17TH TSP
-0.27 17TH TSP Bobbin 43 56 ODI 57 0.55 P 1 83 12TH TSP
+0.31 F/L C/L Special I VOL 1.35 1 146 12TH TSP
+0.34 12TH TSP Bobbin 43 62 WAR 25 1.18 P 4 0 1AVB
+0.00 F/L Bobbin 43 65 WAR 23 1.12 P 4 0 1AVB
+0.00 F/L Bobbin 43 71 WAR 27 1.41 P 4 0 1AVB
+0.00 F/L H/L Tubesheet 43 84 MAI 0.30 1 35 TTS-HL
-1.21 TTS-HL Bobbin 43 86 NQI 12.38 P 1 159 TE-HL
+14.46 F/L H/L Special I MAI 2.20 1 15 TTS-HL
-7.30 TTS-HL Bobbin 44 35 ADI 6.52 6 70 18TH TSP
+6.43 F/L C/L Special I VOL 0.46 1 114 18TH TSP
+6.71 18TH TSP Bobbin 44 39 ADI 5.33 6 70 11TH TSP
+40.70 F/L C/L Special I VOL 0.45 1 123 10TH TSP
-3.17 10TH TSP Bobbin 44 41 ODI 6
0.88 3 143 12TH TSP
+42.36 F/L C/L Special I VOL 0.40 1 119 11TH TSP
-1.70 11TH TSP Bobbin 44 46 WAR 32 2.47 P 4 0 1AVB
+0.00 F/L Bobbin 44 51 WAR 23 1.29 P 4 0 1AVB
+0.00 F/L Bobbin WAR 9
1.88 P 2 0 17TH TSP
+0.00 F/L Bobbin 44 52 WAR 17 0.79 P 4 0 1AVB
+0.00 F/L Bobbin 44 54 WAR 23 1.23 P 4 0 1AVB
+0.00 F/L Bobbin 44 56 NOI 1.30 3 147 17TH TSP
+14.21 F/L C/L Special I VOL 1.07 1 106 17TH TSP
+15.71 17TH TSP Bobbin 44 57 WAR 10 2.09 P 2 0 17TH TSP
+0.00 F/L Bobbin 44 63 ADI 2.21 6 65 7TH TSP
+14.87 F/L H/L Special I VOL 0.66 1 87 7TH TSP
+17.80 7TH TSP H/L Special I VOL 0.88 1 99 7TH TSP
+16.17 7TH TSP H/L Specidl I VOL 1.17 1 93 7TH TSP
+6.94 7TH TSP Bobbin 44 72 ADI 2.30 6 59 7TH TSP
+26.08 F/L H/L Special I VOL 0.29 1 93 7TH TSP
+28.68 7TH TSP H/L Special I VOL 0.52 1 141 7TH TSP
+26.27 7TH TSP Bobbin 44 78 ADI 2.36 6 71 6TH TSP
+36.30 F/L H/L Tubesheet SAI 0.54 1 13 TTS-HL
-0.09 TTS-HL H/L Special I VOL 0.55 1 147 7TH TSP
-8.17 7TH TSP Bobbin 44 84 ODI 4
1.00 3 143 TTS-HL
+6.39 F/L Bobbin ODI 4
+6.48 F/L
BWNT TUBAN II (Version 2.1) 07/13/1995 14:03:21 McGuire Nuclear Station - Unit Two S/G D 12/94 RFO Bobbin,C/L Special Interest,H/L Special Interest,H/L Tubesheet,U-Bend ATTACHMENT #4 - INDICATIONS OF IMPERFECTIONS INDS OF IMPERFECTIONS - SGD TEST TYPE ROW COL IND %TW VOLTS CHN DEG LOCATION EXTENT 1 H/L Special I VOL 0.54 1 208 IST TSP
-2.14 IST TSP H/L Special I VOL 0.59 1 165 IST TSP
+7.25 IST TSP Bobbin 45 40 IDI 66 4.09 P 1 19 TE-HL
+6.49-F/L Bobbin 45 47 WAR 19 0.94 P4 0 2AVB
+0.00 F/L Bobbin WAR 21 1.06 P 4 0 1AVB
+0.00 F/L Bobbin 45 54 WAR 15 0.71 P 4 0 2AVB
+0.00 F/L Bobbin WAR 26 1.54 P4 0 1AVB
+0.00 F/L Bobbin 45 60 WAR 7
1.30 P 2 0 16TH TSP
+0.00 F/L Bobbin 45 62 WAR 4
0.71 P 2 0 17TH TSP
+0.00 F/L Bobbin 45 64 WAR 3
0.53 P 2 0 16TH TSP
+0.00 F/L Bobbin WAR 4
0.74 P 2 0 17TH TSP
+0.00 F/L Bobbin 45 68 WAR 11 0.47 P 4 0 3AVB
+0.00 F/L Bobbin 45 75 WAR 13 0.53 P 4 0 1AVB
+0.00 F/L Bobbin 45 86 IDI 48 10.17 P 1 15 TE-HL
+12.70 F/L H/L Special I SAI 2.74 1 21 TTS-HL
-8.72 TTS-HL Bobbin 45 89 ADI 6.32 6 59 13TH TSP
+5.61 F/L C/L Special I VOL 1.23 1 118 13TH TSP
+4.74 to
+6.37 13TH TSP Bobbin 45 90 ADI 2.85 6 71 11TH TSP
+15.38 F/L C/L Special I VOL 0.73 1 123 11TH TSP
+15.16 11TH TSP Bobbin 46 26 ODI 18 1.41 3 130 7TH TSP
+1.59 F/L H/L Special I VOL 0.54 1 25 7TH TSP
+1.65 7TH TSP Bobbin 46 39 ADI 4.96 6 80 22ND TSP
+7.82 F/L H/L Tubesheet SAI 0.29 1 60 TTS-HL
-0.01 TTS-HL C/L Special I VOL 0.69 1 118 22ND TSP
+8.07 22ND TSP Bobbin 46 59 WAR 11 2.08 P 2 0 18TH TSP
+0.00 F/L Bobbin 46 60 WAR 4
0.75 P 2 0 15TH TSP
+0.00 F/L Bobbin 46 62 NQI 0.52 3 86 12TH TSP
+3.93 F/L Bobbin 46 63 WAR 19 0.93 P 4 0 1AVB
+0.00 F/L Bobbin IDI 27 4.30 P 1 120 TE-CL
+5.14 F/L Bobbin 46 72 WAR 22 1.19 P 4 0 1AVB
+0.00 F/L Bobbin 46 74 WAR 16 0.69 P 4 0 1AVB
+0.00 F/L Bobbin 46 76 ODI 12 0.73 3 135 STH TSP
+27.57 F/L H/L Special I VOL 0.77 1 119 STH TSP
+27.84 STH TSP Bobbin 47 39 WAR 13 2.89 P 2 0 18TH TSP
+0.00 F/L t
Bobbin 47 40 WAR 8
1.63 P 2 0 18TH TSP
+0.00 F/L Bobbin 47 50 WAR 14 3.16 P 2 0 17TH TSP
+0.00 F/L Bobbin 47 51 WAR 10 2.03 P 2 0 17TH TSP
+0.00 F/L Bobbin 47 55 WAR 8
1.66 P 2 0 15TH TSP
+0.00 F/L Bobbin 47 61 WAR 5
1.05 P 2 0 17TH TSP
+0.00 F/L Bobbin 47 62 WAR 13 2.76 P 2 0 17TH TSP
+0.00 F/L Bobbin 47 67 ODI 6
3.78 3 141 11TH TSP
+23.58 F/L C/L Special I VOL 1.44 1 120 11TH TSP
+23.87 11TH TSP Bobbin 47 68 NQI 0.45 P 1 75 15TH TSP
+0.27 F/L Bobbin NQI 0.59 P 1 92 16TH TSP
+0.20 F/L C/L Special I VOL 0.50 P 1 116 16TH TSP
+0.00 15TH TSP Bobbin 47 79 IDI 53 16.93 P 1 19 TE-HL
+14.55 F/L H/L Special I MAI 3.22 1 18 TTS-HL
-5.58 TTS-HL Bobbin 48 35 WAR 7
1.48 P 2 0 17TH TSP
+0.00 F/L Bobbin 48 36 WAR 10 1.99 P 2 0 18TH TSP
+0.00 F/L Bobbin 48 38 WAR 8
1.72 P 2 0 20TH TSP
+0.00 F/L Bobbin 48 40 WAR 7
1.45 P 2 0 20TH TSP
+0.00 F/L Bobbin WAR 19 4.49 P 2 0 18TH TSP
+0.00 F/L Bobbin 48 41 WAR 5
0.97 P 2 0 18TH TSP
+0.00 F/L Bobbin 48 46 WAR 10 2.16 P 2 0 20TH TSP
+0.00 F/L Bobbin 48 47 NOI 3.80 P 1 32 TE-HL
+13.43 F/L Bobbin 4B 48 ADI 3.41 6 65 12TH TSP
+9.55 F/L Bobbin WAR 6
1.24 P2 0 20TH TSP
+0.00 F/L Bobbin WAR 13 2.79 P 2 0 IBTH TSP
+0.00 F/L C/L Special I VOL 0.52 1 129 12TH TSP
+9.39 12TH TSP Bobbin 48 50 WAR 6
1.14 P2 0 17TH TSP
+0.00 F/L Bobbin WAR 12 2.66 P 2 0 18TH TSP
+0.00 F/L Bobbin 48 55 ODI 23 0.12 P 1 117 4TH TSP
+0.00 F/L Bobbin 48 56 WAR 12 2.48 P 2 0 17TH TSP
+0.00 F/L Bobbin 48 57 WAR 7
1.39 P 2 0 15TH TSP
+0.00 F/L Bobbin 48 60 NQI 0.68 P 1 107 13TH TSP
+0.32 F/L l
t
BWNT TUBAN II (Version 2.1) 07/13/1995 14:03:21 McGuire Nuclear Station - Unit Two E-S/G D 12/94 RFO Bobbin,C/L'Special Interest,H/L Special Interest,H/L Tubesheet,U-Bend Page 14 of 14
. ATTACHMENT #4 - INDICATIONS OF-IMPERFECTIONS INDS OF IMPERFECTIONS - SGD TEST TYPE ROW COL IND %TW VOLTS CHN DEG LOCATION EXTENT 1 WAR 6
1.15 P 2 0 15TH TSP
+0.00 F/L Bobbin VOL 0.26 P 1 60 13TH TSP
+0.00 13TH TSP C/L Special I Bobbin 48 62 WAR 31 2.21 P 4 0 1AVB
+0.00 F/L Bobbin.
WAR 20 4.58 P 2 0 17TH TSP
+0.00 F/L Bobbin 48 64 WAR 8
1.61-P 2 0 18TH TSP
+0.00 F/L Bobbin WAR 17 3.85 P 2 0 17TH TSP
+0.00
-F/L'
[
Bobbin 48 65 WAR 4
0.68 P 2 0 15TH TSP
+0.00 F/L Bobbin 48 71 WAR 9-1.89 P 2 0 16TH TSP
+0.00 F/L Bobbin 48 72 WAR 6
1.07 P 2 0 17TH TSP
+0.00 F/L Eobbin 49 54 ADI 5.14 6 74 11TH TSP
+36.86 F/L Bobbin NQI 0.24 P 1 144 3RD TSP
-0.10 F/L Bobbin NQI 0.52 P 1' 94 6TH TSP
+0.22-F/L C/L Special I VOL 1.20 1 142 10TH TSP
-7.85 10TH TSP Bobbin -
49 55 NQI 0.55 P 1 101 17TH TSP
-0.38 F/L C/L Special I VOL 0.57 P 1 147 17TH TSP
+0.00 17TH TSP
' Bobbin 49 56 WAR 7
1.47 P 2 0 17TH TSP'
+0.00 F/L Bobbin WAR 8
1.55.P 2 0 15TH TSP
+0.00 F/L Bobbin 49 57 WAR 12 2.49 P 2 0 ISTH TSP
+0.00 F/L Bobbin 49 58 WAR 17' 3.62 P.2 0 18TH TSP
+0.00 F/L i
Bobbin 49 60 WAR 7
1.27 P 2 0 17TH TSP
+0.00 F/L Bobbin WAR 7
1.37 P 2 0 15TH TSP
+0.00
..F/L Bobbin 49 61 WAR 7
1,39 P 2 0 15TH TSP
+0.00 F/L Bobbin 49 62 NOI 1.19 3 90 1AVB
+15,83 F/L i
U-Bend VOL 0.99 1 156 1AVB
+16.32 1AVB l
Bobbin WAR 5
0.91 P 2 0 15TH TSP
+0.00 F/L Bobbin 49 63 WAR 13 2.83 P 2 0 17TH TSP
+0.00
-F/L Bobbin 49 68 WAR 9
1.80 P 2 0 17TH TSP-
+0.00 F/L Total Indications Found = 872 Total Tubes Found = 456 l
4 l
__a
t-0000000 BWNT TUBAN II (Version 2.1) 07/18/1995 16:18:03 00060**
McGuire Nuclear Station - Unit Two cocoo**
S/G A r
coco ***
12/94 RFO
$000***
Page 1 ATTACHMENT #5 - TUBES PLUGGFD 12/94 RFO COUNT ROW COL COUNT ROW COL 1.
2 61 47.
8 48 2.
3 22 48.
8 53 3.
3 24 49.
8 62 4.
3 28 50.
9 5
5.
3 61 51.
9 20 6.
3 62 52.
9 28 7.
3 64 53.
9 30 8.
3 73 54.
9 31 9.
3 74 55.
9 35 10.
3 83 56.
9 38 11.
4 16 57.
9 75 12.
4 22 58.
10 4
13.
4 34 59.
10 15 14.
4 57 60.
10 19 15.
4 58 61.
10 20 4
16, 4
72 62.
10 40 17.
4 85 63.
10 42 18.
5 56 64.
10 54 19.
5 61 65.
10 60 20.
5 71 66.
11 3
21.
5 107 67.
11 15 22.
6 3
68.
11 53 23.
6 15 69.
12 22 j
24, 6
16 70.
13 56 25.
6 29 71.
13 62 26.
6 59 72.
13 75 27.
6 74 73, 13 88 28.
6 82 74.
13 107 29.
6 109 75.
14 9
30.
6 110 76.
14 73 31.
7 10 77.
15 17 32.
7 20 78.
15 19 33.
7 23 79.
15 36 34.
7 29 80.
15 39 35.
7 36 81.
15 57 36.
7 53 s2.
15 59 37.
7 56 83.
15 71 38.
7 57 84.
15 91 39.
8 3
85.
16 14 40.
8 4
86.
16 19 41.
8 6
87.
16 27 42.
8 14 88.
16 42 l
43.
8 16 89.
17 14 44.
8 27 90.
17 43 45.
8 41 91.
17 62 46.
8 47 92.
17 72 1
L
-Co*****
BWNT TUBAN II (Version 2.1) 07/18/1995 16:18:03 McGuire Nuclear Station - Unit Two oceoo**
S/G A oce****
12/94 RFO Page 2 ATTACHMENT #5 - TUBES PLUGGED 12/94 RFO COUNT ROW COL COUNT ROW COL 93.
17 73 139.
28 19 94.
18 25 140.
28 85 95.
18 37 141.
29 66 f
96.
18 69 142.
29 85 97.
18 104 143.
30 48 98.
19 28 144.
31 15 99.
19 61 145.
31 31 100.
19 63 146.
31 47 101.
19 73 147.
31 49 102.
19 93 148.
32 15 103.
20 50 149.
32 23 104.
20 70 150.
32 29 105.
20 73 151.
32 36 106.
21 31 152.
32 41 107.
21 46 153.
33 16 108.
21 49 154.
33 20 109.
21 50 155.
33 25 110.
22 36 156.
33 57 111.
22 70 157.
33 93 112.
22 88 158.
34 27 113.
23 69 159.
34 46 114.
23 89 160.
34 49 115.
24 52 161.
34 57 116.
24 56 162.
35 24
- 117, 25 15 163.
35 42 118.
25 33 164.
35 54 119.
25 53 165.
35 71 120.
26 33 166.
36 24
- 121, 26 41 167.
36 26 122.
26 45 168.
36 57 123.
26 49 169.
36 65 124.
26 51 170.
36 82 125.
26 56 171.
37 23 126.
26 59 172.
37 46 127.
27 18 173.
37 48 128.
27 19 174.
37 50 129.
27 27 175.
37 51 130.
27 37 176.
38 31 131.
27 49 177.
38 36 132.
27 51 178.
38 40 133.
27 57 179.
39 26
)
134.
27 76 180.
39 31 135.
27 90 181.
39 38
- 136, 27 91 182.
39 41
- 137, 27 93 183.
39 72 i
138.
28 14 184.
40 27 i
000000*
BWNT TUBAN II (Version 2.1) 07/18/1995 16:18:03 000d***
McGuire Nuclear Station - Unit Two coco ***
S/G A occo***
12/94 RFO Page 3 ATTACHMENT #5 - TUBES PLUGGED 12/94 RFO COUNT ROW COL COUNT ROW COL 185.
40 50 186.
40 80 187.
41 36 188.
41 70 189.
42 40 190.
43 65 191.
44 62 192.
44 67 193.
45 63 194.
45 71 195.
45 75 196.
46 82 197.
47 70 198.
47 71 199.
49 41 Total Data Items Found = 199 Total Tubes Found = 199 f
l 1
BWNT TUBAN II (Version 2.1) 07/18/1995 16:19:14 00*****
McGuire Nuclear Station - Unit Two oco****
S/G B
- soo***
12/94 RFO Page 1 ATTACHMENT #6 - TUBES PLUGGED 12/94 RFO COUNT ROW COL COUNT ROW COL 1.
2 51 47.
8 58 2.
2 54 48.
8 60 3.
2 72 49.
8 86 4.
2 77 50.
8 87 5.
2 78 51.
8 88 6.
2 89 52.
8 92 7.
2 91 53.
9 38 8.
2 100 54.
9 53 9.
2 103 55.
9 76 10.
2 104 56.
9 84 11.
2 106 57.
9 90 12.
2 108 58.
9 91 13.
3 13 59.
10 14 14.
3 50 60.
10 59 15.
3 52 61.
10 64 16, 3
62 62.
10 75 17.
3 78 63.
10 77 18.
3 85 64.
10 81 19.
3 93 65.
10 82 20.
4 18 66.
10 101 21.
4 50 67.
10 104 22.
4 51 68.
10 107 23.
4 52 69.
11 19 24.
4 68 70.
11 66 25.
4 69 71.
11 76 26.
4 70 72.
11 81 27.
4 110 73.
11 91 28.
5 61 74.
11 97 29.
5 62 75.
11 98 30.
5 63 76.
11 106 31.
5 65 77.
12 54 32.
5 70 78.
12 59 33.
5 89 79.
12 76 34.
5 103 80.
12 77 35.
6 50 81.
12 81 36.
6 54 82.
12 93 37.
6 89 83.
12 104 38.
6 93 84.
12 106 39, 6 101 85.
13 34 40.
6 106 86.
13 50 41.
6 109 87.
13 62 42.
7 4
88.
13 65 43.
7 76 89.
13 74 44.
7 81 90.
13 76 45.
7 96 91.
13 77 j
46.
8 49 92.
13 96
00C00**
BWNT TUBAN II (Version 2.1) 07/18/1995 16:19:14 0000c**
McG'iire Nuclear Station - Unit Two coooc**
S/G B ococo**
12/94 RFO c******
Page 2 ATTACHMENT #6 - TUBES PLUGGED 12/94 RFO COUNT ROW COL COUNT ROW COL 93.
14 5
139.
23 73 94.
14 20 140.
23 79 95.
14 57 141.
24 7
96.
14 72 142.
24 9
97.
14 104
- 143, 24 35 98.
14 107 144.
24 58 99.
15 73 145.
24 70 100.
16 52 146.
24 76 12..
17 14 147.
24 81 102.
17 28 148.
24 95 103.
17 46 149.
25 7
104.
17 50
- 150, 25 8
105.
17 70 151.
25 34 106.
17 79 152.
25 43 107.
17 84 153.
25 48 108.
17 92 154.
25 58 109.
17 93 155.
25 62 110.
17 99 156.
25 74 111.
18 38 157.
25 79 112.
18 45 158.
25 85 113.
18 62 159.
26 36
- 114, 18 69 160.
26 60 115.
18 96 161.
26 75 116.
19 74 162.
26 82 117.
20 34 163.
26 88 118.
20 52 164.
27 30 119.
20 64 165.
27 57 120.
20 69 166.
27 61 121.
20 72 167.
27 93 122.
20 94 168.
28 59 123.
21 46 169.
28 97 124.
21 53 170.
29 45 125.
21 58 171.
29 48 126.
21 68 172.
29 49 127.
21 69 173.
29 92 128.
22 65 174 30 52
- 129, 22 66 175.
30 90 130.
22 69 176.
31 61 131.
22 79 177.
31 64 132.
22 82 178.
31 84 133.
22 83 179.
32 58 134.
22 87 180.
32 95 135.
23 45 181.
32 98 136.
23 56 182.
33 47 137.
23 69 183.
33 80 138.
23 70 184.
33 85
0000***
BWNT TUBAN II (Version 2.1) 07/18/1995 16:19:14 00000**
McGuire Nuclear Station - Unit Two ocooc**
S/G B ococo**
12/94 RFO l
000c***
1 Page 3 ATTACHMENT #6 - TUBES PLUGGED 12/94 RFO COUNT ROW COL COUNT ROW COL 185.
35 32 186.
36 75 187.
38 77 188.
39 66 189.
39 94 190.
41 50 191.
41 78 l
192.
41 83 193.
43 34 194.
43 41 195.
44 77 196.
44 86 197.
45 32 198.
45 64 199.
45 71 200.
46 44 201.
46 59 202.
47 49 203.
47 69 1
204.
47 74 205.
48 74 206.
48 80 207.
48 83 208.
48 86 209.
49 70 l
Total Data Items Found = 209 Total Tubes Found = 209
)
i l
i
r 1
000****
BWNT TUBAN II (Version 2.1) 07/18/1995 16:20:44 j
ococc**
McGuire Nuclear Station - Unit Two f
oooo***
S/G C ococo**
12/94 RFO I *******
I Page 1 ATTACHMENT #7 - TUBES PLUGGED 12/94 RFO COUNT ROW COL COUNT ROW COL t
1.
2 31 47.
7 83 2.
2 32 48.
8 6
3.
2 50 49.
8 32 4.
2 54 50.
8 41 5.
2 64 51.
8 43 6.
2 70 52.
8 55 7.
2 105 53.
8 56 8.
3 26 54.
8 79 9.
3 65 55.
8 96 10.
3 67 56.
8 109 11.
3 93 57.
9 12 12.
3 104 58.
9 42 13.
4 15 59.
9 47 14.
4 29 60.
9 50 15.
4 52 61.
9 58 16.
4 57 62.
9 69 17.
4 58 63.
9 88 18.
4 74 64.
10 21 19.
4 86 65.
10 39 20, 5
11 66.
10 45 21.
5 41 67.
10 58 22.
5 44 68.
10 60 23.
5 46 69.
10 63 24.
5 55 70.
10 65 25.
5 60 71.
10 93 26.
5 62 72.
11 17 27.
5 72 73.
11 47 28.
5 109 74.
11 51 29.
6 24 75.
11 52 30.
6 40 76.
11 69 31.
6 42 77.
12 15 32.
6 58 78.
12 36 33.
6 64 79.
12 40 34.
6 74 80.
13 11 35, 6
76 81.
13 54 36.
6 80 82.
13 89 37.
6 83 83.
14 17 38 6
97 84.
14 23 I
39.
7 17 85.
14 37 40.
7 20 86.
14 48
]
41.
7 23 87.
14 56 i
42.
7 39 88.
14 58
)
43.
7 40 89.
14 63 44.
7 73 90.
14 65
)
45.
7 74 91.
14 74 46.
7 80 92.
14 76 1
BWNT TUBAN II (Version 2.1) 07/18/1995 16:20:44 McGuire Nuclear Station - Unit Two ocoo***
S/G C j
co*****
12/94 RFO Page 2 ATTACHMENT #7 - TUBES PLUGGED 12/94 RFO COUNT ROW COL COUNT ROW COL 93.
14 77 139.
21 39 94.
15 20 140.
21 47 95.
15 29 141.
21 48 96.
15 33 142.
21 52 97.
15 69 143.
22 37 98.
16 29 144.
23 14 99.
17 11 145.
23 17 100.
17 31 146.
23 26 101.
17 34 147.
23 27 102.
17 42 148.
23 29 103.
17 53 149.
23 35 104.
17 54 150.
23 48 105.
17 60 151.
23 49 106.
17 83 152.
23 58 107.
18 15 153.
23 64 108.
18 20 154.
23 73 109.
18 31
- 155, 24 22 110.
18 33 156.
24 53 111.
18 36 157.
24 62 112.
18 46 158.
24 65 113.
18 51 159.
25 18 114.
18 52 160.
25 24 115.
18 56 161.
25 27 116.
18 58 162.
25 72 117.
18 64 163.
27 31 118.
18 71 164.
27 38 119.
19 14 165.
27 52 120.
19 24 166.
27 58 121.
19 49 167.
28 13 122.
19 51 168.
28 23 123.
19 55 169.
28 57 124.
19 58 170.
29 96 125.
19 62 171.
31 15
- 126, 19 63 172.
31 93 127.
19 73 173.
33 72 128.
20 14 174.
35 43 129.
20 32 175.
35 45 130.
20 52 176.
35 70 131.
20 53 177.
36 67 132.
20 66 178.
38 88 133.
20 89 179.
39 22 134.
20 98 180.
42 93 135.
21 14 181.
43 93 136.
21 22 182.
45 87
- 137, 21 31 183.
47 74 138.
21 36 184.
49 79
000000*
BWNT TUDAN II (Version 2.1) 07/18/1995 16:20:44 00000**'
McGuire Nuclear Station - Unit Two ocoo***
S/G C oooo***
12/94 RFO occoo**
Page 3 ATTA.CHMENT #7
. TUBES PLUGGED 12/94 RFO COUNT ROW COL COUNT ROW COL Total Data Items Found = 184 Total Tubes Found = 184 I
I l
e-000000*
BWNT TUBAN II (Version 2.1) 07/18/1995 16:22:03 00000**
McGuire Nuclear Station - Unit Two cocee**
S/G D ooce***
12/94 RFO ce*****
Page 1 ATTACHMENT #8 - TUBES PLUGGED 12/94 RFO COUNT ROW COL COUNT ROW COL 1.
1 23 47.
8 75 2.
3 13 48.
8 86 3.
3 28 49.
8 93 4.
3 80 50, 8
97 5.
3 91 51.
8 99 6.
3 99 52.
8 107 7.
3 101 53.
8 108 8.
3 103 54.
8 111 9.
3 111 55.
9 62 10.
4 38 56.
9 84 11.
4 39 57.
9 85 12.
4 48 58.
9 96 13.
4 64 59.
9 104 14.
4 81 60.
10 12 15.
4 84 61.
10 46 16.
4 112 62.
10 61 l
17, 4 113 63.
10 62 18.
5 37 64.
10 72 19.
5 39 65.
10 74 20.
5 43 66.
10 81 21.
5 83 67.
11 56 22.
5 99 68.
11 95 23.
6 27 69.
11 101 24.
6 31 70.
12 14 25.
6 36 71.
12 58 26.
6 38 72.
12 60 27.
6 49 73.
12 62 28.
f, 55 74.
12 74 29.
- i 59 75.
12 82 30.
6 69 76.
12 83 31.
6 72 77.
12 94 32.
7 34 78.
13 20 33.
7 56 79.
13 75 34.
7 58 80.
13 89 35.
7 62 81.
13 91 36.
7 64 82.
13 101 37.
7 71 83.
13 110 38.
7 83 84.
13 111 39.
7 87 85.
14 30 40.
7 91 86.
14 49 41.
7 93 87.
14 55 42.
8 41 88.
14 79 43.
8 48 89.
14 83 44, 8
61 90.
14 85 45.
8 63 91.
14 89 46.
8 66 92.
14 100
y~
- e*
BWNT TUBAN II (Version 2.1) 07/18/1995 16:22:03 E
McGuire Nuclear Station - Unit Two cocee**
s/G p ococo**
12/94 RFO Page 2 ATTACHMENT #8 - TUBES PLUGGED 12/94 RFO COUNT ROW COL COUNT ROW COL 93.
14 101 139.
22 97 94.
15 4
140.
22 106 95.
15 5
141.
22 107 96.
15 6
142.
23 82 97.
15 48 143.
23 100 98.
15 58 144.
23 102 99.
15 92 145.
23 103 100.
16 5
146.
24 57 101.
16 6
147.
24 59 102.
16 33 148.
24 69 103.
16 48 149.
24 70 104.
16 62
- 150, 24 103 105.
16 63 151.
25 55 106.
16 71 152.
25 87 107.
16 82
- 153, 25 90 108.
16 100 154.
25 93 109.
17 5
155.
26 57 110.
17 54 156.
26 63 111.
17 56 157.
26 99 112.
17 61 158.
26 102 113.
17 99 159.
27 38 114.
18 59 160.
27 90 115.
18 63 161.
27 93 116.
18 70 162.
27 97 117.
19 44 163.
28 86 118.
19 65 164.
28 99 119.
19 106 165.
28 103 120.
20 57 166.
28 106 121.
20 74 167.
29 91 122.
20 100 168.
29 93 123.
20 101 169.
29 94 124.
20 105 170.
29 97 125.
20 109 171.
30 49 126.
21 6
172.
30 54 127.
21 59 173.
30 88 128.
21 60 174.
30 94 129.
21 61 175.
30 96 130.
21 67 176.
30 97 131.
21 78 177.
30 102 132.
21 99 178.
31 42 133.
21 102 179.
32 17 134.
21 107 180.
32 59
- 135, 22 52 181.
32 76 136.
22 66 182.
32 77 137.
22 77 183.
32 94 138.
22 78 184.
33 66
p.-
0000000 BWNT TUBAN II (Version 2.1) 07/18/1995 16:22:03
'00000**
McGuire Nuclear Station - Unit Two cooco**
S/G D cocco**
12/94 RFO 000****
l Page 3
' ATTACHMENT #8 - TUBES PLUGGED 12/94 RFO COUNT ROW COL COUNT ROW COL-185.
33 85 186.
33 101 187.
34 61 188.
35 95 189.
36 57 190.
36 67 191.
36 88 192.
37 52 193.
37 93 194.
38 73 195.
39 84 196.
39 88 197.
40 74 198.
40 84 199.
41 41 200.
41 70 201.
42 66 202.
43 47 203.
43 56 204.
43 84 205.
44 78 206.
44 83 207.
44 85 208.
46 39 209.
47 56 210.
47 70 Total Data Items Found = 210 Total Tubes Found = 210