ML20087E350
| ML20087E350 | |
| Person / Time | |
|---|---|
| Site: | Surry, North Anna, 05000000 |
| Issue date: | 03/02/1984 |
| From: | Stewart W VIRGINIA POWER (VIRGINIA ELECTRIC & POWER CO.) |
| To: | James O'Reilly NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II) |
| References | |
| 770, IEB-83-08, IEB-83-8, NUDOCS 8403160154 | |
| Download: ML20087E350 (2) | |
Text
,_
.?
Attachment f'
/
/
March 2, 1984 Serial No. 770 Mr. James P. O'Reilly N0/JDH:acm Regional Administrator Docket Nos. 50-280 U. S. Nuclear Regulatory Commission 50-281 Region II 50-338 Suite 2900 50-339 101 Marietta St., N. W.
License Nos. DPR-32 Atlanta, Georgia 30303 DPR-37 NPF-4 NPF-7
Dear Mr. O'Reilly:
VIRGINIA ELECTRIC AND POWER COMPANY NORTH ANNA POWER STATION, UNITS 1 AND 2 SURRY POWER STATION, UNITS 1 AND 2 RESPONSE TO 1.E. BULLETIN No. 83-08 I.E. Bulletin No. 83--08, " Electrical Circuit Breakers with an Undervoltage Trip Feature in Use in Safety-Related Applications Other than the Reactor Trip System," dated December 28, 1983, requested licensees to identify applications of W type DS, W type DS, or GE type AK-2 circuit breakers with the undervoltage trip feature in safety related applications, other than as reactor trip breakers.
The bulletin also requested licensees to identify similar applicaticas of other types of breakers by other manufacturers that use an undervoltage trip feature.
If any breakers described above were identified by the licensee, certain additional actions were required.
We have reviewed the use of all breakers in safety-related applications at both North Anna and Surry and have determined that there are no breakers with undervoltage trip attachments of the type described in the bulletin in any safety-related systems at either station, except for the reactor trip breakers.
Therefore, no additional acticns in response to the bulletin are required.
The bulletin also requested the following information to help NRC evaluate the cost of the bulletin; staff time to perform requested review: 40 staff hours; staff time to prepare requested docunentation: 4 staff hours.
Very truly your l
M.gL. Stewart Y
A 'P l
7405&owy
\\
James P. O'Reilly i
e ec:
U. S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, D. C. 20555 Mr. D. J. Burke NRC Resident Inspector Surry Power Station Mr. M. W. Branch NRC Resident Inspector North Anna Power Station Mr. James R. Miller, Chief Operating Reactors Branch No. 3 Division of-Licensing, NRR U. S. Nuclear Regulatory Commission Washington, D. C. 20555 Mr. Steven A. Varga Chief Operating Reactors Branch No. 1 Division of Licensing, NRR U. S. Nuclear Regulatory Commission Washington, D. C. 20555 i
f e
46 l
l 8
i
\\
COMMONWEALTH OF VIRGINIA )
)
CITY OF RICHMOND
)
The foregoing document was acknowledged before me, in and for the City and Conunonwealth aforesaid, today by W.
L.
Stewart who is Vice ' President. -
Nuclear Operations, of the Virginia Electric and Power Company.
He is duly authorized to execute and file the foregoing document in behalf of that Company, and the statements in the document are true to the best of his knowledge and belief.
Acknowledged before me this 2-day of M M, 19 FY My Commission expires:
4 d 19 S' i b.
"A
. Notary Public 9
J (SEAL) j s/ col I
.