Text
%
~
STONE AND WEBSTER MICHIGAN,INC.
j.
P.O. BOX 1963, MlOLAND, MICHIGAN 48040 3 -s-v/
oar =
.'3 -((,
7 m PAL STAFF
- * "
- 14509 1
y " M,, b
,ty g-2-
a ~o. N/A i
)
3 yi~7 tC SWM-o W
'm "o-77
[~
wA l "'"-
N/A
][M-4)
DEAR SIRS:
O s= r := a ar tv, h>_
- - -h rM.
oLLo-ING aTT CM o:
To DISTRIBUTION h'
- Q~ Q
,,c,,,,,,,
_ co i s _
=~rs _== ooucietes
=wrv== ca o.
=AC-o-O o a- ~as O s ec >cario~s O oocu==~rs O ~ ores o co
===~ce STATUS l
PLEASE NOTE I
SENT !cOR YOUR O.. 6 0
ov==
0==visio~s O
o-...o~.
O a ovac 0 co--=~r l'*"'*
O aooirio~.
O co =crio~s O v==
0 o-ario.
" O 4 o+== 4. =vis= = I ',,,,,,,_
O et ~aar O
-o
=~r O u aee rason O co--=~r.
O
- 2. c==
0 co cu
=~ce i
O sv
=,no~s as ~eno rm CLOSED n
I' YOUR ATTENTION 15 DIRECTED TO THE FOLLOWING:
nsLsA3E0 pon: 0 *.= car.o O u c-ass o ~ c==saa, -ar==ats i
O osass==v s
- ~o su=='t
.~rs
== oouci
's.
-c o><-
= ru =ca os.
O 6==== su.-<r D oocu-=~rs O o a- ~as O n-o
==vaa. e
.~rs oouc'=<==
c o i'- = ru = ca=== on O tsas
==vu ~ o== co, =>c-o== =ar==4'== ~ vou
-ova 6 o cow.ier 2.
l 0 t=4== *:. m-u===
==c=> r o va..
ar==4' er siaa.~a
~o==vu -~a v = =~ctos== co v o r >> o ~.
I O -= v ust 1 ar ra==
~ ovis a acco===~ce - ra vou > u~o==sva~a.
aov.
6=* = aov== us iM PO RTANT ""$N["[,[E.u[.aI.Yaio== v.==visio~s.7.a=o~s wrr a"vNvYa' r[o*u" ens =7."~$'s^rEr'= 'ca~".'.o'"s=Yv="~"'aNE. "i-"" "r co. E E="EvYa "^~'"ES i
au cnas -
our cost.
The following Closed CIO Item / Hold Point Notification (s) is (are) attached for your action /infomation:
% 048 DISTRIBUTION:
J. E. Karr CIO Site File (original + 1)
CIO Program flanager DLQuamme, CPCo NIReichel, CPCo RAWells, CPCo
[JGKeppler..NRC JJHarrison, NRC 8403130479 840305 RJCook, NRC (site)
PDR ADOCK 05000329 44g S
PDR 9g APAmoruso (2)
Initiator
__rzo,,,[l tar.:
i 4
/
Sheet 1 of 1 lH LD POINT NUMBER
'T E" N STONE & WEBSTEN 048 CONSTRUCTION IMPLEMENTATION U '"^ ** ^ """
OVERVIEW O TRACKED INFORMATION ITEM N/Bl4NB NFCIE4N Fl4NT./.0. NO. M509 O TRACKED RECOMMENDATION ITEM REFERENCE (S)
O UNTRACKEDITEM f
O HOLD POINT NOTIFICATION CONDITION DETAILS An inconsistency exists between specification requirements on the spacing between anchor bolts of different diameters.
The specifications in question are:
C-305 - Design, Furnish, Install & Test Expansion Type Anchor Bolts C-306 - Design, Furnishing and Installation of Grouted Anchor Bolts The inconsistency resulted from the issuance of SCN 13007 against Specification C-305.
' Please advise CIO of completion of corrective action in order that the item can be tracked and closed if the corrective action is satisfactory.
YES [o".s >
NO ATTACHMENTS D ATE RESPONSE REQ'D.
INITI [OR/DATE INITIATION APPROVED /DATE January 23, 1984 h, y
///////
,fk/hw H f-gy'
RESPONSE
The attached response, Bechtel Letter BCCC-8987 dated February 6, 1984 has been evaluated by CPCo SMO and is considered an appropriate course of action to resolve this issue. A copy of SCN No 14001 to Spec 7220-C-30G will be provided to you upon issuance.
(PAGE [
\\
YES No.'st I NO
\\
ATTACHMENTS F EST. CORRECTIVE ACTION RESPO DENT TITLE DATE a-4/
- $/ i ]g Gun Cyr COM?LETION DATE
- 21 RESPO DATE RESPONSE VERIFIED / CLOSED DATE
/LibSE. ACCEPTQD 31xhv n^z %
M-8f
%m
/
CIO Item 048 k
I ')
-(s Bechtel Power Corporation P;st Office Box 2167 Midland. Michigan 48840 February 6, 1984 Consumers Power Cmpany P.O. Box 1963 Midland, Michigan 48640 Attention:
D. L. Quamme Site Manager Midland Plant Units 1 & 2 Bechtel Job 7220 REVIEW 0F STONE & WEBSTER'S CCP OVERVIEW REPORT N0. 48 BCCC-8987
Dear Mr. Quamme:
Detailed below is our complete response to Stone & Webster's concern with an inconsistency, which currently exists between Spec. 7220-C-30$ and Spec. 7220-C-306.
To alleviate the present inconsistency caused by SCN C-305-130,07 between Spec. 7220-C-305 and~ Spec. 7220-C-306; relative to anchor bolt spacing.
Bechtel Project Engineering is preparing an "SCN (Specification Change Notice) No. 14001 for Spec. 7220-C-306.
The forecast date, for issuance and attachment to Spec. 7220-C-306 is February 14, 1984.
The forecast date, for incorporation into the text of Spec, 7220-C-306 is March 30, 1984.
If you have any questions concerning the above, please contact J. E. Russell at extension 7240.
Very truly yours,
&AbGM G. A. Hierzer Site Manager GAH/JTM/ t WH/ajd cc:
N. Reichel Written Response Requested: No
_