Text
~
.N Beaver Va ley Power Station Shippmgport, PA 15077 6 je (412) 393-5206 (412) 643-8069 FAX GEORGES THOMAS Divmon Vice President Nucker Gervices Nuclear Power Division August 1, 1995 U.
S. Nuclear Regulatory Commission Attention:
Document Control Desk Washington, DC 20555-0001
Subject:
Beaver Valley Power Station, Unit No. 1 Docket No. 50-334, License No. DPR-66 Recirculation Spray Heat Exchanger Radiation Monitor Sample Lines
Reference:
NRC Letter to Duquesne Light Company dated June 26, 1991; TAC 75772 The referenced letter granted an exemption from the requirements of General Design Criterion 57 that allows the use of the existing recirculation spray heat exchanger radiation monitor sample line downstream
- valves, as an alternative to the original sample line isolation
- valves, for containment isolation.
This letter provides information regarding. the quality requirements for installation and maintenance of the radiation monitor sample piping between the recirculation spray heat exchanger river water piping and the I
isolation valves.
{
The sample lines were purchased and installed to QA Category I and Pipe Class Q3 requirements at the time of installation.
It is our intent to maintain the sample lines as Pipe Class Q2.
If you have any questions about this matter, please contact Nelson R. Tonet, Manager, Nuclear Safety, at (412) 393-5210.
{
l Sincerely, i
/ n.3 C
eo S. Thomas c:
Mr. L. W. Rossbach, Sr. Resident Inspector Mr. T. T. Martin, NRC Region I Administrator Mr.
D.
S. Brinkman, Sr. Project Manager s
$0 non 1-95080B0246 950801 i
PDR ADOCK 05000334 I
p PDR 1