ML20087B257

From kanterella
Jump to navigation Jump to search
Corrected Page 3/4 1-19 to Amend 102 for License NPF-38
ML20087B257
Person / Time
Site: Waterford 
Issue date: 07/31/1995
From:
NRC (Affiliation Not Assigned)
To:
Shared Package
ML20087B259 List:
References
NUDOCS 9508070368
Download: ML20087B257 (1)


Text

r 1

a REACTIVITY CONTROL SYSTEMS LIMITING CONDITION FOR OPERATION (Continued)

ACTION:

(Continued) d.

With one or more full-length or part-length CEAs trippable but misaligned from any other CEAs in its group by more than 7 inches but less than or equal to 19 inches, operation in MODES 1 and 2 may continue, provided that core power is reduced in accordance with the limits specified in the COLR and within I hour the misaligned CEA(s) is either:

1.

Restored to OPERABLE status within its above specified alignment ~

requirements, or 2.

Declared inoperable and the SHUTDOWN MARGIN requirement of Specification 3.1.1.1 is satisfied. After declaring the CEA inoperable, operation in MODES I and 2 may continue pursuant to the requirements of Specificatiotr 3.1.3.6 provided:

a)

Within I hour the remainder of the CEAs in the group with the inoperable CEA shall be aligned to within 7 inches of the inoperable CEA while maintaining the allowable CEA sequence and insertion limits specified in the COLR; the l

THERMAL POWER level shall be restricted pursuant to Specification 3.1.3.6 during subsequent operation.

b)

The SHUTDOWN MARGIN requirement of Specification 3.1.1.1 is determined at least once per.12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />.

Otherwise, be in at least H0T STANDBY within the next 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br />.

e.

With one full-length CEA trippable but inoperable due to causes other than addressed by ACTION a., above, and inserted beyond the Long Term Steady State Insertion Limits but within its above specified alignment requirements, operation in MODES 1 and 2 may continue pursuant to the requirements of Specification 3.1.3.6.

f.

With one full-length CEA trippable but inoperable due to causes other than addressed by ACTION a., above, but within its above specified alignment requirements and either greater than or equal to 145 inches withdrawn or within the Long Term Steady State Insertion Limits if in Nil-length CEA group 6, operation in MODES I and 2 may continue.

g.

With one part-length CEA inoperable and inserted in the core, operation may continue provided the alignment of the inoperable part-length CEA is maintained within 7 inches (indicated position) of all other part-length CEAs in its group and the CEA is maintained pursuant to the requirements of Specification 3.1.3.7.

h.

With more than one full-length or part-length CEA trippable but inoperable due to causes other than addressed by ACTION a., above, restore the inoperable CEAs to OPERABLE status within 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> or be in at least HOT STANDBY within the next 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br />.

WATERFORD - UNIT 3 3/4 1-19 AMENDMENT NO. 11,01,102 9500070368 950731 PDR ADOCK 05000382 P

PDR

,