FLORIDA POWER & LIGHT COMPANY DOCKET N0. 50-335 ST. LUCIE PLANT UNIT N0. 1 AMENDMENT TO FACILITY OPERATING LICENSE Amendment No. 62 License No. DPR-67 1.

The Nuclear Regulatory Comission (the Comissior.) has found that:

A.

The application for amendment by Florida Power & Light Company, (the licensee) dated October 12, 1983 ccmplies with the standards and requirements of the Atomic Energy Act of 1954, as amended (the

/ct) and the Commission's rules and regulations set forth in 10 CFR Chapter I; B.

The facility will operate in conformity with the application, the provisions of the Act, and the rules and regulations of the Comission; C.

There is reasonable assurance (1) that the activities authorized by this amendment can be cor. ducted without endangering the health and safety of the public, and (ii) that such activities will be conducted in compliance with the Comission's regulations; f,'.

The issuance of this amendment will not be inimical to the common defense and security or to the health and safety of the public; and l

E.

The issuance of this amendment is in accordance with 10 CFR Part l

51 of the Comission's regulations and all applicable requirements l

have been satisfied.

t 8403060080 840224 DR ADOCK 05000335 PDR t

2.

Accordingly, Facility Operating License No. DPR-67 is amended by changes to the Technical Specifications as indicated in the attach-ment to this license amendment, and by amending paragraph 2.C.(2) to read as follows:

(2) Technical Specifications The Technical Specifications contained in Appendices A and B, as revised through Amendment No. 62, are hereby incorporated in the license. The licensee shall operate the facility in accordance with the Technical Specifica-tions.

3.

This license amendment is effective as of the date of its issuance.

FOR THE NUCLEAR. REGULATORY COMMISSION jT

. //d, 9 h v.

James R. Miller, Chief Operating Reactors Branch #3 Division of Licensing

Attachment:

Changes to the Technical Specifications Date of Issuance:

February 24, 1984 l

.A_TTACHMENT TO LICENSE AMENDMENT N0. 62 TO FACILITY OPERATING LICENSE NO. DPR-67 DOCKET N0. 50-335 Replace the following pages of the Appendix "A" Technical Specifications with the enclosed pages.

The revised pages are identified by amendment number and contain vertical lines indicating the area of change. The corresponding overleaf pages are also provided to maintain document com-pleteness.

Pages 6-3 6-4 l

i l

i

ini

=-

Pu.T MmCER _________3__

g gu,;,g. g g,

1 r-C I

I o

,~,,

I

__ I I

I I

g 8

MAa4TE4ARCE if CualCAL ADMINISTR ATIVE QUALITY C04'ROL OPtflAft0ms

$UPE Rl41 E h0E NT

TApp Asss31A47 STAFF l

SUPER 14Tih0ENT c

2 I

H I

I I

I I

e I I

I I

-a tr.$TRUME NT ASSISTANT AS$l$1 ANT AND

$UPERimitNDENT

$UPE R14T140f.41 SE CURITY CutMt3TRy NEAlin

$A9 TR W hG RE ACTOR CONTROL ELECTRICAL MECn41 CAL SUPERvlSOR suttavis0R PnYsiCS OPE RATt3h5 SUPE RVISO R

$UrtRvts0R

$dPERY133R SUPERvfSOR

$UPE RVIS0g MAINTENANCE MAlWT!4ANCg l

I I

I I

i i

i ENGINEERS E4GlHER$

ENGlWEEll$

ENGimEER5 ENGibtERS E4Gl4EER$

CUARDS CL E RK1 AhD AND AND TituniciAms TEcumiCiA4s TituniciAns ygCyniCAns TECusiciAns PUWT TECunetiAss SUPENISOR o,

I w

l e

usa 0 CulJ5 MAimTENANCE As$!$w

" rum" E L E CT RICiAN FOREMAN I

$UPERVE50R I

R0 letTRUMENT A40 ELECTRICIAN $

MACul4IST CONTROL CENTER f

CONTROL APPRENTICES MECnAhlC5 OPERATOR n..iAtists utLPER$

AP'RENTICES 3

APPRENTICES nL& PE R g

CLa m,

rt U4LICthsto OPERATOR $

O m

u, Figure 6.2-2 Unit Organization - St. Lucie Plant, Unit 1 u,

Table 6.2-1 MINIMUM SHIFT CREW COMPOSITIONE i

l WITH THE OTHER UNIT IN MODES 5 OR 6 OR DE-FUELED POSITION NUMBER OF INDIVIDUALS REQUIRED TO FILL POSITION MOCES 1, 2, 3, & 4 MODES 5 & 6 SS (SRO) la la SR0 1

None

1 D

A0 2

2 STA 1

None WITH THE OTHER UNIT IN MODES 1, 2, 3, OR 4 POSITION NUMBER OF INDIVIDUALS REQUIRED TO FILL POSITION MODES 1, 2, 3, a 4 MODES 5 & 6 SS(SRO) la ga SR0 1

None R0 2

1 A0 2

1 STA la None SS - Shift Supervisor R0 - Licensed Reactor Operator SR0 - Licensed Senior Reactor Operator A0 - Auxiliary Operator STA

Shift crew composition may be less than the minimum requirements for a period of time not to exceed 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> in order to accommodate unexpected absence of on duty snift crew members provided immediate action is ta':en to restore the shift crew composition to within the minimum requirements of Table 6.2-1.

g Individual may fill the same position on the other unit.

_bf One of the two required individuals may fill the same position on tne other unit.

ST. LUCIE - UNIT I 6-4 Amendment No. 37, M, 62

f.RE:

/

UNITED STATES 8

3 NUCLEAR REGULATORY COMMISSION O

j WASHINGTON, D. C. 20555

%,,.....f FLORIDA POWER & LIGHT COMPANY ORLANDO UTILITIES COMMISSION OF THE CITY OF ORLANDO, FLORIDA AND FLORIDA MUNICIPAL POWER AGENCY DOCKET NO. 50-389 ST. LUCIE PLANT UNIT N0. 2 AMENDMENT TO FACILITY OPERATING LICENSE Amendment No. 5 License No. NPF-16 1.

The Nuclear Regulatory Commission (the Commission) has found that:

A.

The application for amendment by Florida Power & Light Company et al.,

(the licensee) dated October 12, 1983 complies with the standards and requirements of the Atomic Energy Act of 1954, as amended (the Act) and the Commission's rules and regulations set forth in 10 CFR Chapter I; B.

The facility will operate in conformity with the application,

, the provisions of the Act, and the rules and regulations of the Commission; C.

There is reasonable assurance (1) that the activities authorized by this amendment can be conducted without endangering the health and safety of the public, and (ii) that such activities will be conducted in compliance with the Commission's regulations; D.

The issuance of this amendment will not be inimical to the common defense and security or to the health and safety of the public; and E.

The issuance of this amendment is in accordance with 10 CFR Part 51 of the Commission's regulations and all applicable requirements have been satisfied.

e

2.

Accordingly, Facility Operating License No. NPF-16 is amended by change:: to the Technical Specifications as indicated in the attach-ment to this license amendment, and by amending paragraph 2.C.2 to read as follows:

2.

Technical Speciffcations The Technical Specifications contained in Appendices A and B, as revised through Amendment No.

5, are hereby incorporated in the license. The licensee shall operate the facility in accordance with the Technical Specifica-tions.

3.

This license amendment ir effective as of the date of its issuance.

FOR THE NUCLEAR REGULATORY COPHISSION

,7:$

/

I

/ ames R. Miller, Chief J

Operating Reactors Branch #3 Division of Licensing

Attachment:

Changes to the Technical Specifications Date of Issuance:

February 24, 1984

=.. _ _ _.

ATTACHMENT TO LICENSE AMENDMENT NO. 5 TO FACILITY OPERATING LICENSE NO. NPF-16 DOCKET NO. 50-389 Replace the following pages of the Appendix "A" Technical Specifications with the enclosed pages. The revised pages are identified by amendment

. number and contain vertical lines indicating the area of change. The corresponding overleaf pages are also provided to maintain document com-pleteness.

E Pages 6-4 6-6 9

0 i ~

, a M

t i _

v, V

%j

..,s

,_L.. _ r,,. _,,, - _ _

~

~

7

~

&N T

O NGTI ENGT DRMC U

SETR l

E ECT R GmSN S

P ENoO CERC I

P V

R R

A O r

t S

Y A

E R o

T R

E L A p

N S Y I

TE L G C

G A

LC C

I EDSD R F AN UN U O p

E F

I B

u SCML O A t

A NS N

s J

ENE N CR U

RN Y W l

O T

OR E

a RAT R

EE N I ic l

PVS H EA S

GC

%V E S DY C RE I L G A AU iE n

EAS E D C A

N MR h

C T

U N

A O

c I

V N

A M

C e

t M

dna tn T

e N

m E

E D

1 e V

I

2. g T

S a

E 6n f

U R a

C P

e m E

R r

X E EP u

E I

GT gy C

it AP Fil V

N-AR ic MA a

f E

T L r

NC o

R AU R

f LN E

G P

G P n

E A T o

N P it ANP A

a MP M L iz AT S

n TS a

E NO g

I AF T

r S

L o

P Y

e Y

GF Y

Y G

RF its T G G

R EA f

N R R

RE S NT f

0E RE EN E ES O

E 4 P E

GE C

SE G E A

RS AR N RI AE I

V ER N A A EA R E C P A A

ML E LA EL M E.

S CR E

C 2

U UE CC J

X R

N NS Y

IVM M

EGG AR R

NE E

AN GA ME N

R AL TA MS

' NE P

A L T

TC N

SJ A

I4 S9 L

S P

A U. rC m ' E Z g pw

~+

h nuCL,gstate steettts '

taa E.,;u;y

,t a.,.a. 01.- -________y__

gy,4g.,gg, j

1 i

r-I C

I n

I I

I I

I rn I

I 0 taan0*s sues'niete=Otar

==it manCs stCnn Cat a0mmistaanvt ovautv C0=in0t su*t amit =Oi =1 stars assistant stase g

c Z

I l

l N

I I

I t 1 I

I l

19sTptutti ass 8sf a4T assasfa4F a40 suPlai41t 40t 47 suPlainf tmotet st Cuail' CMa uesT R, niattu see T 8a848%G miaC10A su't # wis0R suFt RytsO n PWTssCs OPf RaTI0ms suet avison supt aves 08 C047m0L E Litf RiCat Ut CutisCat suet avsson supt evis0 A 1

suetavisOn Maiet t manCE maintimatCE 1

1 I

"Yg'o"*

""'j*n'g" NUCLEAR "Yn'O t a r. int r as t =cin a t as t =c.n,e t as cuanos

,,,,g tt C==itia=s ricumiCiaws itCwsiCians itCnisiCans rtCumiCians PLANT ggC,e,Ctaas SUPERVISOR cn a

b Sa0 assgstaat Cait s waista magCt uuCCtaa tt t Ct aitian scatwa%

  1. LANI suPttflsos no issf euwl 4!

amL tit C!aitians vat.. gist C0h1AOLCthtta y

Cott#0L AP*at tfiCis vtCaatics k

V at t Pt as seeal%fiCis se,i cialists at4TeCis

=t t et e 3b

=>

(3 3

r*

uttsCanst o 2

OPinaTORs C) u, Figure 6.2-2 Unit Organization - St. Lucie Plant, Unit 2

Table 6.2-1 MINIMUM SHIFT CREW COMPOSITION TWO UNITS WITH TWO SEPARATE CONTROL ROOMS WITH UNIT 1 IN MODE 5 OR 6 OR DEFUELED POSITION NUMBER OF INDIVIDUALS REQUIRED TO FILL POSITION MODE 1, 2, 3, or 4 MODE 5 or 6 8

a SS (SRO) 1 l

SRO 1

None R0 2

1b A0 2

2 STA 1

None WITH UNIT 1 IN MODE 1, ?, 3 OR 4 POSITION NUMBER OF INDIVIDUALS REQUIRED TO FILL POSITION MODE 1, 2, 3, or 4 MODE 5 or 6 8

a SS (SRO) 1 l

SRO 1

None RO 2

1 A0 2

1 a

STA l

None SS *-

Shift Supervisor with a Senior Reactor Operator's License on Unit 2 SR0 Individual with a Senior Reactor Operator's License on Unit 2 l

RO Individual with a Reactor Operator's License on Unit 2 l

AO Auxiliary Operator l

STA Shift Technical Advisor Except for the Shift Supervisor, the Shift Crew Composition may be one less than the minimum requirements of Table 6.2-1 for a period of time not to exceed 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> in order to accommodate unexpected absence of on-duty shift crew members provided immediate action is taken to restore the Shift Crew Composition to within the minimum requirements of Tab'le 6.2-1.

This provision I

does not permit any shift crew position to be unmanned upon shift change due to an oncoming shift crewman being late or absent.

During any absence of the Shift Supervisor from the Control Room while the

(

unit is in MODE 1, 2, 3 or 4, an individual (other than the Shift Technical Advisor) with a valid SRO license shall be designated to assume the Control l

Room command function. During any absenc* e of the Shift Supervisor frai the i

Control Room while the unit is in MODE 5 or 6, an-individual with a valid SRO or R0 license shall be designated to assume the Control Room command function.

a/ Individual may fill the same position on Unit 1 b/ One of the two required individuals may fill the same position on Unit 1.

ST. LUCIE - UNIT 2 6-5 1

ADMINISTRATIVE CONTROLS 6.2.3 INDEPENDENT SAFETY ENGINEERING GROUP (ISEG)

FUNCTION 6.2.3.1 The ISEG shall function to examine plant operating characteristics, NRC issuances, industry advisories, Licensee Event Reports and other sources of plant design and operating experience information, including plants of similar design, which may indicate areas for improving plant safety.

COMPOSITION 6.2.3.2 The ISEG shall be composed of five dedicated, full-time members with varied backgrounds and disciplines related to nuclear power plants. No more than two members shall ne assigned from any one department. Three or more of the members shall be engineers with a bachelor degree in engi6eer16g or a related science, with at least 2 years of professional level experience in the nuclear field. Any nondegreed ISEG members will either be licensed as a Reactor Operator or Senior Reactor Operator, or will have been previously licensed as a Reactor Operator or Senior Reactor Operator within the last year at the St. Lucie Plant site; or they will meet the qualifications of a department head as specified in Specification 6.3.1 of the St. Lucie Unit 2 Technical Specifications.

The qualifications of each nondegreed candidate for the ISEG shall be approved by the Assistant Chief Engineer - Power Plant Engineering, prior to joining the group.

RESPONSIBILITIES 6.2.3.3 The ISEG shall be responsible for maintaining surveillance of selected plant activities to provide independent verification

  • that these activities are performed correctly and that human errors are reduced as much as practical. The ISEG shall make detailed recommendations for revised procedures, equipment modi-fications, maintenance activities, operations activities, or other means of improving plant safety to the Assistant Chief Engineer-Power Plant Engineering.

AUTHORITY 6.2.3.4 The ISEG is an onsite independent technical review group that reports offsite to the Assistant Chief Engineer-Power Plant Engineering. The ISEG shall have the authority necessary to perform the functions and responsibilities as delineated above.

RECORDS 6.2.3.5 Records of activities performed by the ISEG shall be prepared, main-tained and a report of the activities forwarded each calendar month to the Assistant Chief Engineer-Power Plant Engineering.

6.2.4 SHIFT TECHNICAL ADVISOR The Shift Technical Advisor function is to provide on shift advisory technical support in the areas of thermal hydraulics, reactor engineering, and plant analysis with regard to the safe operation of the unit.

6.3.

UNIT STAFF QUALIFICATIONS 6.3.1 Each member of the unit staff shall meet or exceed the minimum qualifica-tions of ANSI /ANS-3.1-1978 as endorsed by Regulatory Guide 1.8, September 1975 (reissued May 1977), except for the (1) Health Physics Supervisor who shall meet

  • Not responsible for sign-off function.

ST. LUCIE - UNIT 2 6-6 Amendment No. 5

-