ML20086Q116

From kanterella
Jump to navigation Jump to search
Forwards Audit Rept A-V-89-02. QA Audit Rept,Teledyne Isotopes Midwest Lab,Northbrook,Il 890208-09, as Part of NRC Insp of Chemistry & Radiological Environ Monitoring Programs Conducted During Wk of 911118
ML20086Q116
Person / Time
Site: Point Beach  
Issue date: 12/16/1991
From: Zach J
WISCONSIN ELECTRIC POWER CO.
To: House J
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
Shared Package
ML20086Q120 List:
References
VPNPD-91-446, NUDOCS 9112300005
Download: ML20086Q116 (2)


Text

_ _.. _ _ _ _ _ _ _.. _ _ _ _ _. _. _ _. - _ _ _ _ _ _. _. - _.. _ _

l W!sconsin

~

i Electnc POMR COWAM nt w Mewn to 8:n Lu wea*e # !mi (MO #1 M I

VPHPI, 4 4 6 HRC 150 December 16, 1991 d

Mr. John House, Region III U.S. NUC?' REGULATORY COMMISSION 799 Roos.

. Road Glen Ell'n., Illinois 60137 Dear Mr. House A%O DOCKETS _50'226 AND 50-301 f

PROGRAM AND VENDOR _AUDITE

]MDlQLOGICAL ENVIRONMENTAL MONITORING PROGRAM POINT BEAQ.B NUCLEAR PLAl{1 As part of the NRC inspection of the Chemistry and Radiological Environmental-Monitoring Program activities at PBNP during the week of November 18, 1991, copies of audits conducted by Wisconsin Electric's Quality Assurance Section of PBNP's Radiological Environmental Monitoring Program and of Teledyne Isotopes Midwest Laboratory, the vendor performing the radionnalyses of the REMP samples, were requested.

Pursuant to your request, copies of these documents are enclosed.

Should you require additional information, please contact Dr. Kjell Johansen of our staff at (414)221-3966.

Very truly yours,

{

/

6

<%c

{

Ja' s J. Zach Vice President Nuclear Power Copies to:

NRC Document Control Desk 3l\\

NRC Resident Inspector N

N'\\

/1

/h, N

g(j n13 n00003 911216 japg ADOCK 05000 @h

_jg_

g_,

FD e

j

'g

.4 subsMan dHluvashi/W Ge;wathn -

. ~. _, _

4.

"bt '[\\ c f

h s

I t

March 9, 1989 QAL-89-034 i

Mr. L. G. Huebner General Manager Teledyne Isotopes Midwest Laboratory 700 Landwehr Road Northbrook, Illinois 60062 4517 f

Dear Mr. Huebner:

SUBJECT:

WISCONSIP ELECTRIC QA AUDIT AUDIT NO. A-V-89-02 1

Attached is the audit report of the Teledyne Isotopes Midwest Laboratory, (TIML) which was conducted at your new location in Northbrook Illinois on-February 8-9 1989 Asaresultof-theaudit,three(3)findIngsandsix (6)observatlonswe.re issued.. A written response to all items is required by April 10, 1989.

Please provide your responses by completing the

" Corrective Action" sections of the attached Audit Finding Reports (AFRs),

and return the originals to me by the due date. Also, include in your response the scheduled date(s) for completion of corrective action (s), as-applicable.

Please note that corrective action for AFR #A-V-89-02-015 will be required by both TIML and Pe%t Beach Nuclear Plant.

Thank you for your excellent cooperation and gracious hospitality extended I

to the audit team during the audit ~.

If you have any questions, please call'me at 414/221-2804.

l Very truly yours, I

A 0.g.rq, A. 2. Pusztai ProjectSpecialist

-Quality Assurance mef Attachments-bec:

W. W. Doolittle, K. A. Johansen, D.' F.' Johnson, E.-J. Lipke, J..E. Peters, J. J. Zach, C. W-Fay /J. B. Gill, File Q1.3.1 wwipV FI_E COPY