Requests Inclusion of Encl Listed Technical Corrections Into Subsequent Revs to SE Re Core Shroud Repair
ML20086G601
Person / Time
Site: Quad Cities  Constellation icon.png
Issue date: 07/10/1995
From: Schrage J
COMMONWEALTH EDISON CO.
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
NUDOCS 9507170007
Download: ML20086G601 (2)


Text

,. - -

y o>mmonscahh latiwn company I

I 400 opm Pl.nc g

Ih,w nerk Grm t; !!. 60515 july 10,1995 l

U.S. Nuclear Regulatory Commission Washington, D.C. 20555 Atta: Document Control Desk

Subject:

Quad Cities Station Units 1 and 2 Technical Review of USNRC Safety Evaluation for Quad Cities Station Core Shroud Repair NRC Docket Nos. 50-254 and 50-265

Reference:

R.M. Pulsifer to D.L. Farrar letter dated June 8,1995 In the Referenced letter, the NRC Staff transmitted a Safety Evaluation for the proposed repair of the Quad Cities Station Core Shroud. Commonwealth Edison (Comed) has completed a technical review of the NRC Staff Safety Evaluation, and has identified three technical corrections. These are described in the attachment to this letter. Comed requests inclusion of these technical corrections into subsequent revisions to the Safety Evaluation.

To the best of my knowledge and belief, the analyses and evaluations contained in these documents are true and correct. In some respects these documents are not based on my personal knowledge, but on information furnished by other Commonwealth Edison employees, contractor employees, and/or consultants. Such information has been reviewed in accordance with company practice, and I believe it to be reliable.

If there are any questions, please contact John L. Schrage at 708-663-7283.

v a m,w.:::-----------

Sincerely, OFFICIAL SEAL J ACQUELINE T EVANS

/

Noi AMY PUUUc. ST ATE oF ILLINOIS

[

P4Y COMWf&of1 EXPmES:12/15/97

.- v m

..w

,wc::::::::-

y g3 uclear Lic nsing Administrator 2M4e

>- / bMa Ykof91"

/

8 Attachment H.J. Miller, Regional Administrator - Region III cc:

R.M. Pulsifer, Project Manger - NRR C. Miller, Senior Resident Inspector - Quad Cities Office of Nuclear Facility Safety -IDNS 9507170007 950710 0k PDR ADOCK 05000254

,lg p

PDR u mo m o,inpanv

e n.

ATTACHMENT Technical Corrections to USNRC Staff Safety Evaluation, d%ed June 8,1995 Quad Cities Station Units 1 and 2 Core Shroud Repair Comed has identified three technical corrections to the NRC Staff Safety Evaluation for the Quad Cities Station Unit 1 and Unit 2 Core Shroud repair. These are described below. The suggested correction is underlined and highlighted by bold type.

1.

Page 3, Section 2.1, first paragraph, third sentence, Change the last statement to read as follows:

"As stated in Section 2.3.2, Comed also inspected the vertical welds and determined that un cracking in these welds he been found."

2.

Page 4, Section 2.2, third paragraph, fourth sentence, in order to make this section consistent with section 2.4.6 on page 14, change the sentence to read as follows:

" Vertical separation for any and all welds is precluded exceptfor the postulated design events addressed in section 2.4.6 of this SE

  • 3.

Page 18, section 2.5.2, Change the first paragraph, first sentence, after item "6" to read as follows:

".... which connects the steam dam to theflange and, (b) six (6) circumferential..... ). "