ML20086E195

From kanterella
Jump to navigation Jump to search
Ro:On 740114,during Insp of Metal Clad Keyed Top Reflector Elements,Burrs Found on Drilled Holes in Bottom of Distribution Plate.Seven Elements Installed Will Be Removed. Procedure from Ga Co Awaited
ML20086E195
Person / Time
Site: Fort Saint Vrain 
Issue date: 01/14/1974
From: Swart F
PUBLIC SERVICE CO. OF COLORADO
To: Howard E
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
Shared Package
ML20086E200 List:
References
NUDOCS 8312060255
Download: ML20086E195 (1)


Text

,,_.

r O

O V7 public service company e cenetrade a

i; P. O. Box 361, Platteville, Co173ragio 80651 c

1 9

y C

. _.t,u h

w January 14, 1974 r

Mr. E. Morris Howard f

Director, Directorate f

Regulatory Operations, Region IV h

USAEC 10395 West Colfax h

Denver, Colorado 80215 L

Dear Mr. Howard:

I i

About 4:00 AM, Monday, January 14, 1974, during inspection of the metal clad keyed top reflector elements, we found that there were burrs on some of the drilled holes in the bottom distribution plate and machining chips in the plenum area between the graphite box portion and the lower distri-i

[

bution plate of some of these elements in the warehouse.

One of the chips y

found was about 1" in diameter, large enough to plug a coolant passage.

-..3 F

[? <

Up to this time, 28 elements had been inspected, seven of which had been

%%g" L

installed in the reactor.

'I. 2.

E

a.. ; ' l Our plans are to remov the seven elements f rom the reactor and re-inspect

^ $ ' y the 28 elements previously inspeceed.

',<] $ >

w g

We are presently awaiting a procedure from General Atomic to proceed with

,,. a-

[

the inspection and clean-up of these reflectors.

E

_[

Very truly yours4

/

f 8

[

a

' d_[Q.

Frederic E. Swart k

Superintendent E

Fort St. Vrain Nuclear y

Generating Station FES:ll

[

E E

F

,',rl F

8312060255 740114 E

PDR ADOCK 05000267 r

S PDR r

~-

=