ML20086D656

From kanterella
Jump to navigation Jump to search
Updated AO 73-17:on 730614,drywell Purge & Vent Exhaust Valve V-16-19-7A Failed to Shut.Valves V-16-19-4 & V-16-19-16 Closed,Insuring Containment Integrity.Valve Will Remain Shut Until Primary Integrity Not Required
ML20086D656
Person / Time
Site: Vermont Yankee Entergy icon.png
Issue date: 06/21/1973
From: George Thomas
VERMONT YANKEE NUCLEAR POWER CORP.
To:
US ATOMIC ENERGY COMMISSION (AEC)
Shared Package
ML20086D660 List:
References
AO-73-17, VYV-2741, NUDOCS 8312020434
Download: ML20086D656 (1)


Text

_-

e O O

, YERMONT YANKEE NUCLEAR POWER CORPORATION SCVENTY SEVEN OMOVC STRCCT ,

RUTLAND. Viuntour osvoi VYV-2741 P.O. BOX 157 VERNON, VERMONT 05354 V

June 21, 1973

& ll A

Director $\

Directorate of Licensing U.S. Atomic Energy Commission [ k[;h\iD519~l3' L 'i 2

JM

~

Washington, D.C. 20545 1,g 7 u.V A ~j,

REFERENCE:

Operating License DPR-28  % .. _ . 4 Docket No. 50-271 h ui W" Abnormal Occurrence No. A0-73-17 h,h

Dear Sir:

As defined by Technical Specifications for the Vermont Yankee Nuc1 car Power Station, Section 6.7.B.d, we are reporting the following Abnormal occurrence as A0-73-17.

At 0015 on June 14, 1973, during preparation for a reactor startup, Drywell Purge and Vent Exhaust valvo V-16-19-7A f ailed to shut. The inoperability of valve V-16-19-7A exceeds the Limiting Conditions for Operation as defined by Section 3.7. A.2 of Tech. Specs. The subject section states that primary containment integrity shall be maintained at all times when the reactor is critical or when the reactor water temperature is above 212*F and fuel is in the reactor vessel. The reactor was shutdown and reactor water temperature was 480*F at the time of the incident.

Valves V-16-19-4 and V-16-19-16 were closed iramediately insuring containment integrity. V-16-19-7A was subsequently shut and its air operator was secured.

./ The Plant Operations Review Committee reviewed the incident and

/f, concluded that the valve will remain shut and its air operator secured

',"' until such time that primary containment integrity is not required. At

[,p that time, the valve will be disassembled and repaired.

.gj u

^ "l I Very truly yours,

' j # b. 8312020434 730621 s DR ADOCK 05000271 VERMONT YANKEE NUCLEAR POWER CORPORATION PDR ks $hm George Thomas Assistant Plant Superintendent t

FJB/kbd 4071 COPY SENT REGION

['

_.