[d
{
BROOKHAVEN NATIONAL LABORATORY.
ASSOCIATED UNIVERSITIES, INC.
Structural Analysis Division Upton. Long Island. New York 11973 Department of Nuclear Energy Bu t I di ng 129 (516) 282x 2447 FTS 666' September 28' 1983 Mr. Bernard Turovlin Rom No. P-302 Phillips Bldg.
US Nuclear Regulatory Cmmission
~ ' -
7920 Norfolk Avenue Bethesda, MD 20814
Dear Mr. Turovlin:
Enclosed is the Technical Evaluation Report entitled "Three Mile Island Unit 1 Steam panerator LEFM and Load Characterization".
It was prepared following BNL's review of various GPUNC documents.
Yours tr.aly, f)
~
a Paul Bezler, ' Group Leader Dynamic Response Evaluation Group jm Encl.
pc:
V. Benaroyo B. Grenier W.'Kato C. McCraken /
C. Poslusny J. Rajan P. Wu l
8311140080 831103 I
~