ML20085M554

From kanterella
Jump to navigation Jump to search
Forwards Second Interim Rept of Vibrations Detected in Torus & torus-ring Header on 731128.Rept Describes Plans for Relief Valve Tailpipe Mod,Interim Inservice Insp & Planned Confirmatory Testing.W/O Encl
ML20085M554
Person / Time
Site: Browns Ferry 
Issue date: 05/07/1974
From: Eric Thomas
TENNESSEE VALLEY AUTHORITY
To: Oleary J
US ATOMIC ENERGY COMMISSION (AEC)
Shared Package
ML20085M537 List:
References
NUDOCS 8311080629
Download: ML20085M554 (1)


Text

(

L.2 O

n J

V TENNESSEE" VALLEY AUTHOAITY 03 CHATTANOOGA, TENNESSEE i o.s f

3740'l L

~

JT NI C]

~

ANN"iDCCt5ih AY May 7, 1974 pgafpHI h'

?-

Th

"[

wp %;f v Q

x. RF ;

Mr. John F. O' Leary, Director

/7]/ ii j_

UrQ[C-r 3

I Directorate of Licensing N

g Office of Regulation

-11 1'

U.S. Atomic Energy Commission Li N UW Washington, DC 20545 6

U.I.N' E

uassnua

Dear Mr. O' Leary:

b f

TENNESSEE VALLEY AUTHORITY - BROWNS FERRY NUCLEAR PLANT UNIT 1 -

DOCKET NO. 50-259 - FACILITY OPERATING LICENSE DPR SECOND INTERIM REPORT ON VIBRATIONS IN TORUS AND TORUS-RING HEADER Please refer to my letters dated November 28, 1973, enclosing abnormal occurrence report BFAO-7343W, and December 17, 1973, enclosing an interim report on the vibrations in the torus and torus-ring header.

Enclosed is a second interim report which documents the chronology of the problem; summarizes the. testing and test results to date; and describes our plans for relief valve tailpipe modification, interim inservice inspection, and planned contirmatory testing. A final report will be submitted upon completion of the unit i relief valve tailpipe modifications and subsequent confirmatory testing.

Very truly yours, TENNESSEE VALLEY AUTHORITY E. F. Thomas

. Director of Power Production k

Enclosure -

t CC (Enclosure):

Mr. Norman C. Moseley, Director Region II Regulatory Operations Office, USAEC 230 Peachtree Street, NW.

Atlanta, Georgia 30303 1

\\

(

V b

v~ 4 8311080629 731130 PDR ADOCK 05000259 S_

PDR

s

~._

COPY SENT RMION '

_.. w s

m

<