Responds to NRC Re Violations Noted in IE Insp Rept 50-358/82-10.Corrective Actions:Personnel Changes Made & Procedures Revised for Update of Welder Qualification Cards.Programs for Welder Qualification Will Be Audited
ML20085K718
Person / Time
Site: Zimmer
Issue date: 09/23/1983
From: Williams J
CINCINNATI GAS & ELECTRIC CO.
To: James Keppler
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
Shared Package
ML20085K716 List:
References
LOZ-83-0146, LOZ-83-146, NUDOCS 8310210110
Download: ML20085K718 (14)


Text

r-Li n

Y h

THE CINCINNATI GAS & ELECTRIC COMPANY

,Q CINCINNATI, OHIO 45201 September 23, 1983 LOZ-83-0146 J. WILLIAMS, JR SENIOR VtCE PRESIDENT NUCLEAR OPERAff0NS Docket No. 50-358 U.S. Nuclear Regulatory Commission Region III 799 Roosevelt Road Glen Ellyn, Illinois 60127 Attention:

Mr. J.G. Keppler Regional Administrator Gentlemen:

RE:

WM. H. ZIMMER NUCLEAR POWER STATION - UNIT 1 I.E.

INSPECTION REPORT 82-10 W.O.'57300, JOB E-5590,' FILE NO. 956C,'IR-82-10 This letter supercedes our previous response to the subject Inspection Report.

The information contained herein provides additional details regarding implementation activities associated with the corrective actions proposed.

It is our opinion that nothing in this report is of a proprietary nature.

(

NRC ITEM'OF NONCOMPLIANCE ~358/82-10-01(A)

The following documents provide guidance concerning the maintenance of welder qualification:

l

  • Wm. H. Zimmer Quality Assurance Manual, Paragraph 9.3
  • ASME Code, Sect: ion III, Paragraph NA-4220
  • AWS Code Dl.1-1972, Section 5.30 i

j Contrary to these requirements, the method employed by the H.J. Kaiser Project Weld Engineer for verifying that a welder used a specific process to maintain current qualification status was not_comensurate-with the applicable code requirements.

The KE Weld-2 form by itself'did not provide objective evidence that the welder had actually used the specific process.

A.

Corrective Action Taken And Results Achieved The method used for verifying that a welder had used a specific process was described in WCP-2, Rev. O, TCN #2-3 h

C310210110 831017 gjf g,6 PDR ADOCK 05000358 g

PDR

.~

~. -.

r Mr. J.G. Keppler Regional Administrator September 23, 1983 LOZ-83-0146 Page 2 (dated 6-7-82), and subsequently WCP-2, Rev. 1, Section 4.1.27, which states in part:

"For previously qualified welders holding valid

' Welder Qualification Cards', a new card will be prepared (in ink) which will show (on backside) all procedures to which the welder is certified as qualified.

The card, when completed, will be dated and laminated.

The ' Welder Qualification Card' will automatically void at 90 days after issue.

By review of the rod withdrawal log before the card is reissued to the welder, the welders recent (within the 90-day period) welding activities will be critiqued for preformance of welds to the indicated procedures / processes.

If an indicated process has not been used during the allotted (90 day) time period, it will be deleted from the welders t

qualification listing and a requalification will be l

mandatory."

The example cited of this noncompliance describes the l

issuance of a welders qualification card which was not in compliance with the established welder's qualification l

maintenance system delineated in WCP-2.

Personnel changes have been made and procedures revised for the update of welder qualification cards.

The Qualification Card for Welder MGG was recalled by Welding Engineering and returned on July 20, 1982.

Subsequently, a new (updated) card was issued to. Welder MGG in accordance with the process for Welder Qualification Maintenance.

1 L

The above described incident cannot be determined to be an isolated incident.

The Computerized Welding Information System (CWIS) program has been established for welder qualification maintenance prior to November 12, 1982.

This program will identify welder qualification maintenance by quality documentation or by supporting documentation in those cases where qualification maintenance cannot be established by a quality document. If Welder Qualification Maintenance cannot be established for a particular welder and had the j

welder welded during the time when he was not qualified, a i

1

~.

..,w--,.

d i

Mr. J.G. Keppler Regional Administrator September 23, 1983 LOZ-83-0146 Page 3 deficiency document shall be generated and appropriately dispositioned.

HJK is revising procedures used to maintain welder qualifications to require objective evidence that a welder had actually used a specific process.

The procedures will be available for NRC review by November 30, 1983.

B.

Corrective Action To Avoid'Further Noncomp'.iance

~

CG&E will assure that programs for welder qualification will be audited semi-annually to verify compliance with revised procedures.

C.

Date Full Compliance Will Be Achieved Full compliance will be achieved upon issue of the revised procedures.

NRC ITEM OF' NONCOMPLIANCE'358/82-10-01(B)

The following documents provide guidance concerning the maintenance of welder qualification:

4

  • Wm. H. Zimmer Quality Assurance Manual, Paragraph 9.3
  • AWS Code Dl.1 - 1972, Section 5.30 More specifically, the HJKaiser Quality Assurance Procedure, QAP-10, and Weld Construction Procedure, WCP-2, identified the requirement.tx) establish and accurately maintain a computerized welder qualification listing.

Contrary to these requirements, the computerized printout of qualified welders was not being maintained, and the HJ Kaiser list of Active Welders, dated July 9, 1982, did not accurately reflect the qualifications of welder, (e.g. symbol LMF) as indicated on the welder's qualification card.

Mr. J.G. Keppler Regional Administrator September 23, 1983

-LOZ-83-0146 Page 4 A.

Corrective Action Taken And Results Achieved Since the time of the inspection, the need for welder listings and subsequent use of the listings has been investigated and clarified.

The " Welder Qualification Listing" referenced in OAP-10, Paragraph 3.2.3.7, is a separate " welder listing" and has a different function than the " Active Welders List" reflected in WCP-2, Paragraph 3.2.1 (now' referred to as the " Current Welders List", per WCP-2, Rev. 2, Paragraph 3.3.3.).

The " Welder Qualification Listing" per QAP-lO is intended to 1xa a listing of all welders who have qualified at the Wm. H.

Zimmer Nuclear Power Station-Unit 1, for the Henry J. Kaiser Company during the entire duration of the construction work.

The purpose of the " Current Welders List" reflected in WCP-2 is to provide construction supervision (i.e.,

Superintendents, General Foreman, Foreman) and Engineers a

" tool" for purposes of planning by which welders can be matched with known or upcoming construction activities / applications, thus promoting the most efficient utilization of the welding force.

This list is also used to determine upcoming expiration dates in association with qualification maintenance.

This list is not used as a basis for determining the qualification status of a welder or for issuance of weld rod.

The welder's card has been and currently is the controlling factor in determination of a l1 welder's current qualifications.

The information entered on the Welder Qualification Card has been and currently is compiled from welder qualification documentation and logs i

utilized for qualification maintenance.

~

Commencing in August, 1982, a joint effort between HJK Quality Records Management (ORM), Weld Engineering and CGEE to produce an accurate computerized listing of Active Welders began, with the first " list" subsequently issued October 18, 1982.

Although discrepancies were identified, an effort by HJK Weld Engineering and CG&E is underway to correct and modify the Active Welders List to accurately reflect the welders qualifications in accordance with quality documentation and the Welder Qualification Cards.

~

Mr. J.G. Keppler Regional Administrator September 23, 1983 LOZ-83-0146 Page 5 B.

Corrective Action Taken To Avoid Further Noncompliance QAP-10 does state in part that "The Welding Engineering Manager shall be responsible for the accuracy and continual and timely updating of the Welder Qualification Listing".

This responsibility can only be performed by the organization which controls and stores the original " Welder Qualification Test' Records" which is the Quality Records Management (ORM) organization of the HJK Quality Assurance Department.

Therefore, QAP-10 will be revised to reflect the responsibility for producing the " Welder Qualification Listing" including the accuracy, continual and timely updating of the same be assigned to the QRM organization of the Quality Assurance Department.

An ongoing effort by the QRM organization to compile the

" Welder Qualification Listing", per QAP-10, has been in progress since August, 1983.

C.

Date Full ~ Compliance Will Be Achieved Full compliance in regard to the " Current Welders List",

referenced in wCP-2, paragraph 3.3.3, has been achieved.

Revision to QAP-lO is scheduled to be completed by December 31, 1983.

Production of the Welder Qualification List is contingent upon completion of the welder qualification reviews currently being conducted by HJK QRM and CG&E QCP Task II.

These review programs are scheduled to be completed l

by December 31, 1983.

t

.-.--__.m.,

- -... _,. - - - -,,,, ~ _

c Mr. J.G. Keppler Regional Administrator September 23, 1983 LOZ-83-0146 Page 6 NRC ITEM OF NONCOMPLIANCE 358/82-lO-02(A)

The following documents provide guidance concerning the documentation of evaluation for reportability under 10CFR21 and 10CFR50.55(e).

  • Wm. H. Zimmer Quality Assurance Manual Paragraph 5.1

Contrary to the above requirements, the licensee failed to impose the reporting requirements of 10CFR21 and 10CFR50.55(e) on contractors in that the H.J. Kaiser Company had neither procedural controls in place to require the evaluation and documentation of reportable or potentially reportable deficiencies, nor procedures in place to require informing the licensee of reportable or potentially reportable deficiencies.

A.

Corrective Action Taken And Results Achieved CG&E has performed a review of 10CFR21, NUREG-0302, Rev. 1 and 10CFR50.55(e) in preparing the response to this item.

i.

HJK was notified per letter KEQ-184 on January 4, 1978, of the then recently published 10CFR21 requirements.

NUREG-0302, Rev. 1, Section 21.31, question 6 states "The licensee's responsibility for insuring compliance with the provisions of Part 21 by its contractors, suppliers and consultants is limited to the requirement that each procurement document for a facility or basic component specifies that the provisions of 10CFR21 apply, when 7

applicable."

CG&E=has reviewed procurement procedures OPP 4.1, 4.2 and 4.3 and finds that they impose this requirement.

A review is underway to ensure applicable CG&E procurement documents issued after January 6, 1978, made appropriate references to l

.the applicability of 10CFR21.

Mr. J.G. Keppler Regional Administrator September 23, 1983 LOZ-83-0146 Page 7

' Corrective' Action Request (CAR) #82-36 was issued April 26, 1982, requiring the principal constructor to establish a documented program to control reviews of potentially reportable deficiencies.

In response to the CAR, HJK developed an implementing procedure GQP-21, " Reporting of 10CFR21 or 10CFR50.55(e) conditions".

This procedure requires HJK to review potentially reportable conditions and submit the documented results of these reviews to CG&E.

CORRECTIVE ACTION TAKEN TO' AVOID FURTHER NONCOMPLIANCE B.

CG&E has conlucted an extensive training program for personnel assigned the responsibility for the review of Corrective Action Nonconformance Reports, Audit Reports, Requests, Condition Evaluation Requests, and Engineering Change Requests.

This training indoctrinated personnel in both the identification of potentially reportable conditions, and the method (OPP 7.1) for alerting appropriate management of such conditions.

The CGEE Quality Assurance Department (QAD) audits contractor compliance with OPP 7.1 requirements.

This is evidenced by Corrective Action Requests which identify the lack of contractor identification of potentially reportable conditions.

C.

'Date Corrective Action Will Be Achieved Corrective Action will be achieved upon completion of the above mentioned purchase document review, scheduled to be completed by November 30, 1983.

NRC ITEM OF NONCOMPLIANCE 358/82-10-02(B)

The following documents provide guidance concerning the activities affecting quality and their associated procedural provisions.

  • Wm. H. Zimmer Quality Assurance Manual, Paragraph 5.1
  • H.J. Kaiser Procedure, GOP-9, Rev. O,

_m.-

P-Mr. J.G. Keppler Regional Administrator September 23, 1983 LOZ-C3-0146 Page 8 paragraph 4.1.3 Contrary to the above, H.J. Kaiser Procedure GOP-9 for control of requests for information/ evaluation (RFI/E) was not followed by the Welding Task Force (WTF) Chairman in that he failed to log reports forwarded by site personnel to the Welding Task Force for response as required.

A.

Corrective Action Taken And Results Achieved GQP-9 was revised to expand and clarify RFI/E logging and review requirements.

A memo was sent to all inspection supervisors informing them of the requirement.

Also, a memo was transmitted to all managers requesting return of all RFI/E's to the Lead Reports Coordinator so that they could be assigned a Log number for response.

B.

Corrective Action Taken to Avoid Further~ Noncompliance The WT2 Chairman has been made aware by memo from his supervisor, dated 4/7/83, that procedures must be strictly adhered to, and has received additional training in GOP-9, Rev. 2.

C.

Date'When Full Compliance Will Be' Achieved Full compliance has been achieved.

NRC ITEM OF NONCOMPLIANCE 358/82-10-02(C)

The following documents provide guidance concerning the activities affecting quality and their associated procedural provisions.

  • Wm. H. Zimmer Quality Assurance Manual, Paragraph 5.1
  • Weld Construction Procedure, WCP-2, Rev.0 paragraph 4.1 Contrary to the above, the review of activities in the weld test shop indicated that the HJK Kaiser Co. Procedure, WCP-3 for

F N

Mr. J.G. Keppler Regional Administrator September 23, 1983 LOZ-83-0146 Page 9 control of weld filler metal was not being fully implemented in the test shop in that the weld rod was issued by weight and returned by weight rather than by actual count of rods issued and stubs returned.

Corrective Action Taken and Results Achieved A.

In July, 1982, the issuance of weld filler material by count versus weight was implemented in the Weld Test Facility to meet the existing requirements contained within Welding (WCP) 3 " Filler Material Control".

Construction Procedures The applicability of WCP-3's requirements for filler material to the Weld Test Shop were not explicit.

WCP-3 control addressed. control of filler material for the fabrication and installation process but requirements for control of filler material in the Weld Test Facility were not explicitly clear.

Subsequently, in August 1982, WCP-2 titled " Welder Performance Qualification" was revised to encompass the filler material. control. requirements in the Weld Test Facility.

Corrective Action Taken to Avoid Further Noncompliance

_B. -

Based on the above corrective action, we feel that no additional corrective action is required.

C.

Date when Full Compliance will be Achieved Full compliance has been achieved.

NRC ITEM OF NONCOMPLIANCE 358/82-10-03 i

The following documents provide guidance concerning welder l

qualification documentation requirements.

  • Wm. H. Zimmer Quality Assurance Manual, paragraph 16.1 Contrary to above requirements, The Cincinnati Gas & Electric Company OA Division and the H.J. Kaiser Company OA Organization i

l

4 Mr. J.G. Keppler Regional Administrator September 23, 1983 LOZ-83-0146

+

Page 10 failed to take corrective action regarding the lack of evidence of radiographic acceptability for welder qualifications The identified on H.J. Kaiser Corrective Action Report No. 84.

corrective action statement proposed by H.J. Kaiser weld engineering and subscribed to by H.J. Kaiser and CG&E Quality Assurance was inadequate to assure that all welders onsite currently performing quality-affecting activities were properly qualified in accordance with the applicable codes and standards.

Corrective Action Taken and^Results' Achieved A.

The requirements for the retention of radiographic reader sheets for welder qualification sere not clearly stated in the ASME Sections III and IX, 1971 editions through the Winter 1973 addendum.

The H.J. Kaiser QA Program did not for welder require radiographic reader sheet retention Recent code interpretations, qualification records.

editions, and addenda have provided additional clarification as to the intent of the code with regard to the retention of These radiographic reader sheets for welder qualifications.

ASME III clarifications were not available until March 1980.

t and IX are clear on the requirement for certificate holders to maintain a record signed by an authorized individual.

Conformance with this requirement has been through the use of the Ol-G Form recommended by ASME Section IX.

The response by H.J. Kaiser to CG&E Field Audit Report 126 1977 committed H.J. Kaiser to retain dated August 2, This radiographic reader sheets for welder qualification.

commitment was restated by H.J. Kaiser in response to CG&E's i

establishment of a site requirement for the retention of radiographic reader sheets related to welder qualification.

This

'(See CG&E letter to HJK KEO-loll dated 5/11/82).

. commitment was reiterated in HJK's response to CG&E CAR 82-51.

therefore, CG&E's position that prior to August 2, I

It is, the lack of radiographic reader sheets supporting

1977, otherwise acceptable welder qualification records is not a basis for the rejection of the welder's qualification.

For j

welder qualifications certified by radiography dated after

,-g

~+,ra~

~

v vs vx,w,e,,,,,,,m

-,-,s,,,w,,,m,,

e n m,-,

a-- -

--r---

-,,,v-w,-----,-,--,w-v

+--~,m,,---.-e--n-,

-,v-n-r,---,,

-,u:

Mr. J.G. Keppler Regional Administrator l

September 23, 1983 LOZ-83-0146 t

Page 11 1977 and prior to May 11, 1982, either an August 2, acceptable radiographic reader sheet or an RT level II's acceptance signature for the radiographic examination documented on the Ql-G form in the space provided for the recording of the radiographic test results, or the stamp of form in the space the RT Level II on the applicable KE-1 shall provided for acceptance of the radiographic results, the results of the' radiographic i

acceptably document examination.

Welder qualification records certified by radiography dated after May 11, 1982 must be accompanied by Deviations from an acceptable radiographic reader sheet.

these requirements will be documented on deficiency documents l

and appropriately dispositioned.

Corrective Action to Prevent Further Noncompliance

.B.

further noncompliance is precluded in that CG&E At this time, requires H.J. Kaiser to maintain in the welder qualification This file the appropriate radiographic reader sheet.

practice has been in effect since May 1982.

Date When Full Compliance Will Be Achieved l

C.

all HJK welder To ensure compliance with this position, qualification records are being evaluated by QCP Task II and appropriate deficiency documents are being initiated whenIt is

(

i required.

by December 31, 1983.

NRC ITEM OF NONCOMPLIANCE 358/82-10-05(A)

The following documents provide guidance concerning welder qualification records.

  • 10 CPR 50, Appendix D, Criterion XVII f

l Contrary to the above, changes were made to welder qualification records without adequate procedures or controls.

_,... _ - ~

r Mr. J.G. Keppler Regional Administrator September 23, 1983 LOZ-83-0146 Page 12 Corrective Action Taken and Results Achieved A.

The alteration or supplementation to quality documentation in welder qualification packages has been addressed in the As Welder Qualification Review Program developed by HJK QA.

review of welder qualification a part of this program, packages provides for the documentation of deviations with regard to alterations to the quality documents as outlined below.

Where Welder qualification documentation alterations or supplementation which cannot be substantiated per QRM-1,

" Review and Control of Quality Assurance Documentation",

A special Material deficiency documents have been generated.

Review Board has been established to document the acceptance and/or method to be used to establish the acceptability of installed hardware by those welders.

Corrective Action Taken to Avoid Further Noncompliance B.

1983, to emphasize Site Communique #28 was issued January 24, the requirements of ANSI N45.2.9 concerning theTo augment this supplementation of quality documentation. site wide training was con i

action, This training now constitutes significance of ANSI N45.2.9.

ORM-1 a portion of the overall site indoctrination program.is utilized to QA documentation is' clearly identified and justified prior to turnover as QA records.

Date Full Complaince Will Be' Achieved C.

Full compliance will be achieved at such time as all deficiency documents generated have been appropriately dispositioned.

l NRC ITEM OF NONCOMPLIANCE 358/82-10-05(B)

The following documents provide guidance concerning welder qualification records.

m Mr. J.G. Keppler Regional Administrator September 23, 1983 LOZ-83-0146 Page 13

  • ANSI N45.2.9-1974, paragraph 3.2.6 Contrary to the above, qualification records for The KE Q-lG forms approximately 32 welders had been rewritten.for two weld These records had been completely rewritten.

(The changes made by the record originator or equivalent.

included clarification-type data changes such as coupon thickness, bend test, travel speed, etc.)

There were no procedural controls which allowed such changes and there were no annotations on the rewritten records indicating The the changes made or providing justification for the changes.

original records were retained in the H.J. Kaiser Weld Engineering files and were not transmitted to the site QA Records Only the rewritten records were transmitted Management system.

to the site QA Records Management system.

' Corrective Action Taken to Avoid Further Noncompliance

~

A.

All available welder qualification related documentation has been retrieved from H.J. Kaiser Co. Welding Engineering by These means of the Site Document Retrieval program.

documents were subsequently transmitted to Quality Records Quality Records Management is Management for review.

reviewing all welder qualification related documents This review will be transmitted to their organization.

and conducted in accordance with CG&E procedure QCPP-9.21, all deficiencies will be documented.

Corrective Action Taken to Avoid Further Noncompliance B.

1983, to emphasize Site Communique #28 was issued January 24, the requirements of ANSI N45.2.9 concerning theTo augment this supplementation of quality Socumentation. site wide training was c

action, This training now constitutes significance of ANSI N45.2.9.

ORM-1 a portion of the overall site indoctrination program." Review is utilized to verify that supplementation of HJK generated QA documentation is clearly identified and justified prior to turnover as OA records.

Mr. J.G. Keppler Regional Administrator September 23, 1983 LOZ-83-0146 Page 14 C.

Date Full' Compliance Will Be Achieved Full compliance will be achieved at such time as all deficiency documents have been appropriately dispositioned.

We trust this supplement provides clarification as to the CG&E efforts which have been implemented to address the items of noncompliance identified in Inspection Report 82-10.

Very truly yours, THE CINCINNATI GAS & ELECTRIC COMPANY By ;

gw

. WILLIAMS, JR[

SENIOR VTCE PRE DENT GAB /sfr cc:

NRC Office of Inspection & Enforcement Washington, D.C.

20555 NRC Senior Resident Inspector ATTN:

T.P. Gwynn NRC Zimmer Project Inspector, Region III ATTN:

E. R. Schweibinz