4
}
LEE LE *
- Tele ram
- Western Union w
VEC246(l746) C1-033804C017)P3 0I/gg$1(T4fli 5: 03
^
ICS IPMVEIC MVN n
~
03195 TSVE MORRIS IL 102 01-17 315P CST
- 3 US ATOMIC ENERGY COMMISSION WUX 799 ROOSEVELT ROAS GLEN ELLYN IL 60137 SUBJECT DPR-25 BRESSEN NUCLEAR POWER STATION UNIT #3.
38 THIS WILL CONFIRM A CONVERSATION WITH MR F. MAURA 0F YOUR OFFICE AT 1415 HOURS THIS DATE CONCERNING A FAILukE 6
0F THE SEAM A5 MISSION VALVES ON HIGH PRESSURE C00 LENT So INJECTION TURBINE TO OPEN THEREBY RENBERING THE HPCI SYSTEMS INOPERABLE. THE FAILURE WAS BETECTER ON JAN 17e 1974 AT 330 HOURS WHILE CONSUCTING THE REQUIRES HPCI SURVEILLANCE BUE To THE PREVIOUS FAILURE OF 3A ELECTR0MATIC RELEASE VALVE.
i
.s, 1
EEE E E '
- Tele ram' Western union l
03V139
.., 1, wi AN ORDERLEY SHUT 30WN IN ACCOR9ANCE WITH ECTION '315.pcj es mi C.3 0F THE TECHNICAL SPECIFICATIONS WAS IMIEDIATELY INITIATES.
W P WORDEN Nb SUPT DRESSEN NUCLEAR POWER STATION COMMONWEALTH E31 SON COMPANY ROUTE I MORRIS IL TELEGRAMS (OTHER THAN MONEY ORDERS )
NNNN IEPHYSICAL DELIVERY requested?,_(YES-AGENT, NO-ADDRESSEE)
ADDREAEE 5 " TION (($E b b
-}o r N-.
Q AGENT SECTION Nbr.A Name.
.) Time did /XS VATyD1V Byf Y a
Date did /- / J l
3 To be mailed or filed _ L/// W/N'
{
Attecpts to. deliver (Indicate DA or BY) j JAN. 21 2074 -
h
~
i esimuaai
- enti e, g
f*
't UNITED STATES r.i
' '.1 ATOMIC ENERGY COMMISSION
%,, W j$
OlVISION OF COMPLIANCE REGION lli tragg e 799 ROOSEVELT ROAD 7gggpgogg GLEN ELLYN, ILLINOIS 60137 (31z) ass-zeso A.
RO Inspection Report No.
Transmittal Date Distribution:
Distribution:
R0 Chief, FS&EB RO Chie f, FS&EB R0:HQ (5)
RO:HQ (4)
DR Central Files L:D/D for Fuel & Materials Regulatory Standards (3)
DR Central Files Licensing (13)
RO Files
~
RO Files B.
RO Inquiry Report No.
Transmittal Date Distribution:
Distribution:
RO Chief, FS&EB R0 Chief, FS&EB RO:HQ (5)
RO:HQ DR Central Files DR Central Files Regulatory Standards (3)
RO Files Licensing (13)
RO Files C.
Incident Notification From: Commonwealth Edison Co. Docket No. 50-249 (Licensee & Docket No. (or License No.)
- January 21, 1974 Transmittal Date Distribution:
Distribution:
RO Chief, FS&EB RO chief, FS&EB RO.HQ (4)
RO:HQ (4)
Licensing (4)
L:D/D for Fuel & Materials DR Central Files DR Central Files RO Files RO Files
-[s t'
Y V
n
"