05000(56Ofof
^.
aa idZ6 THE Nuclear Reactor Laboratory 1298 Kinnear Road W
Columbus, OH 43212-1154 Phone 614-292-6755 FAX 614-292-2209 5o-/60 J
UNIVE" 19 May 1995 Ms. Gloria Bennington U.S. Nuclear Regulatory Commission Storage and Transport Systems Branch Mail Stop : TWFN 8 F-5 Washington,DC 20555 Subject : Advanced Notification for Category II Material from the Ohio State University
Dear Ms. Bennington :
j l
The purpose of this letter is to serve as advanced notification of a shipment of Category II I
material from the Ohio State University to Westinghouse Savannah River Co. This letter is intended to meet the requirements of :
- 49 CFR 173.22 (C),
- 10 CFR 73.67 (E)(1)(i), and
- 10 CFR 73.72 (A)(3).
49 CFR 173.22 (C) requires that the consignee be given the following notice :
- The estimated date of shipment : 1 June 1995
- The estimated date of amval : 2 June 1995 10 CFR 73.67 (E)(1)(i) requires that we provide the following information to the receiver :
I
- The mode of transportation : Motor vehicle carriage by public highway
- The estimated time of arrival : 0800 2 June 1995
- The location of transfer points : No in-transit transfer points - exclusive use 1
l shipment
- Name of carrier : Tri-State Motor Transit Co.
- Transport identification : Savannah River authorization number NPM 34492 10 CFR 73.72 (A)(3) requires that the advanced notification to the NRC include the following information :
- The name, address, and telephone number of the shipper :
The Ohio State University Nuclear Reactor Laboratory 1298 Kinnear Rd.
Columbus, Ohio 43212 (614) 292-6755 Attn : Jeff Davis 9506220036 950519 PDR ADOCK 05000150 P
PDR 21O O.3 N
, gh College of Engineering
- The name, address, and telephone number of the receiver :
Westinghouse Savannah River Co.
Savannah River Site Building 244-11 Aiken, South Carolina 29808 (803) S57-8773 Attn : Matt Beckum
- The name, address, and telephone number of the carrier :
Tri-State Motor Transit Co.
PO Box 4888 Pocatello, Idaho 83205 (208) 232-3445 l
Attn : Jesse Bunch
- The physical description of the shipment :
- The physical form : Solid metal - UAix
- The quantity : 24 HEU fuel assemblies loaded with 3180g U235 and i
containing 2.2 Ci mixed fission products
- The type of reactor : Light water moderated pool type reactor
- Original enrichment : 93.2 %
- Additional information :
- Mode of shipment : Motor vehicle carriage by public highway
- Transfer points : No in-transit transfer points - exclusive use shipment
- Route : Kinnear Rd., Kenny Rd., Lane Ave., OH State - 315, OH I - 71, OH Bypass - 275, KY I - 71, KY I - 75, TN I - 75, TN I - 40, TN I - 640, TN I - 40, NC I - 40, NC 1 - 26, SC I - 26, SC I - 20, SC State - 19
- Estimated time that the shipment will commence : 1200
- Estimated date that the shipment will conunence : 1 June 1995
- Estimated time of arrival of the shipment : 0800
- Estimated date of arrival of the shipment : 2 June 1995 Please look this over to make sure that you have all of the information that you need. If there are any questions, please feel free to call me.
Sincerely,
$&Ao Daw Michael J. Davis
-