ML20085G977

From kanterella
Jump to navigation Jump to search
Interim Deficiency Rept Re Rust Discovered on Inside Surface of Reactor Pressure Vessel.Initially Reported on 740926.Util & Westinghouse Studying Methods for Correcting Deficiency
ML20085G977
Person / Time
Site: Browns Ferry  
Issue date: 10/25/1974
From: Gilleland J
TENNESSEE VALLEY AUTHORITY
To: Knuth D
US ATOMIC ENERGY COMMISSION (AEC)
References
10CFR-050.55E, 10CFR-50.55E, NUDOCS 8308300017
Download: ML20085G977 (1)


Text

r-

~]

O r~')

W4.

~

TENNESSEE VALLEY AUT),CRITY CH ATTANOOGA, TENNESSEE 374o1 i

October 25, 1974 Mr. Donald F. Knuth, Director Directorate of Regulatory Operations U.S. Atomic Energy Commission Washington, DC 20545

Dear Mr. Knuth:

SEQUOYAH NUCLEAR PLANT UNITS 1 AND 2 - DEFICIENCY INVOLVING RUST ON INSIDE SURFACE OF REACTOR PRESSURE VESSEL Initial report of the subject deficiency was made verbally to W. B. Swan, AEC-DRO Region II Inspector, on September 26, 1974.

In compliance with paragraph 50.55(e) of 10 CFR Part 50, this is submitted as an interim report. TVA and Westinghouse are studying methods for correcting the subject deficiency. A report will be submitted upon completion of the studies.

Very truly yours,

/

& /}k-

,/)

/m n w J. E. Gilleland Assistant to the Manager of Power

.CC:

Mr. Norman C. Moseley, Director Directorate of Regulatory Operations U.S. Atomic Energy Commission Region II - Suite 818 230 Peachtree Street, NW.

Atlanta, Georgia 30303 I

8308300017 741025 PDR ADOCK 05000259 S

PDR

[0*&

j o

. An Equal Opportunity Employer gg.

i

.g

.... ~. - - - -.

l{p ~o l' i

L

_j