j )$4y h y { (( G September 5, 1991 NGIVPN:
6798 Mr. Lee 11. Be t tsnhausen, Chief Operation Branch Division of Reactat Safety U. S. Nuclear Regu.'atory Commission Region 1 475 Allendale Road King of Prussia, PA 19406
Reference:
lieaver Valley Power Station, Unit 1 Docket No. 50-334 License DPR-66 Licensed Operator Requalification Examination Report
Dear Mr. Bettenhaus'en:
The purpose of this letter is to provide the results of Duquense Light Company's evaluation of the Licensed Operator Requaliffr.ation Examination conducted at Unit I the weeks of August 12 and August 19, 1991. A summmary of the examination results is provided along with individual results for each operator examined. These examination res"'t: !..&c.
a that the Beaver Valley Licensed Operator Requalification Program is satisf actory overall and that some oper* tor retraining is needed in defined areas.
We have taken necessary corrective actions based on the examination results. The individual who failed the plant walk through portion and the crew that failed to meet our expected performance level vill be upgraded and re-evaluated.
In addition a list of ars is needing general training emphasis is attached, and is being used to enhance the operator retraining program.
In ow view the current examination process continues to work well.
The NRC Examination Team interacted effectively with t$eaver Valley personnel to adminster the examination.
If there are any questions regarding our evaluation of the examination or our corrective act. ions please contact Mr. T. W.
Burns, Director Operations Training at (412) 393-5751.
Very truly yours,
's D.![leber o
9110210049 91100s Vice President (DR ADOCK 05000334 Nuclear Group PDR
3 l'a ge 2 NC I VI'N :
6748 Septeniber 5, 1941 TWB/JDS/ Lip Enclasure cc:
Mr. T. T Martin, NRC Regional 1 Administration Mr.
A.
W.
DeAgazio, Project Manger Mr. J.
Bcall, Sr. Pesident inspector Mr. P.
Bissett, Chief Examiner r-
-J
~
BEAVER VALLEY UNIT 1 REQUAllFICATION EXAH AUGUST 12-22. 1991 Exami_ nation Summary Besults D_cility Evaluators Simulatcr:
8-15 91 1 crew passed f.D. Schuster, Unit 2 1 crew failed Operations Manager 8 individuals passed 8-21-91 2 crews passed L.G. Schad, Simulator 8 individuals passed Training Supervisor Elant Walk-Thrnush 8-13/8-14-91 7 individuals passed R.J. Brooks, Senior 1 individual failed Nuclear Operations Instructor 8 18/8-19-91 8 individuals passed A.W. Beckert, Senior Nuclear Operations Instructor T.W. Bean, Simulator Instructor Written 8-16-91 8 individuals passed T. Gaydosik, Senior Nuclear Operations Instructor 8-22-91 8 individuals passed A.W. Beckert, Senior Nuclear 0porations Instructor J.P. Shipe, Nuclear Shift Operating Supervisor T.k.'. Bean, Simulator Instructor R.J. Brooks, Senior Nuclear Operations Instructor Overall:
15 individuals passed 1 individual failed 3 crews passed I crew failed
/
e*, S -
BEAVER VALLEY UNIT 1 REQUALIFICATION EXAM AUGUST 12-22, 1991 The following areas, although not necessarily generic weaknesses, were identified as needing additional training emphases in the !icensed Operator Retraining Program.
Written Exam Section A Effects of a closed MSIV on the setpoint calculations for OPDT and 0 TDT trips.
Use of steam tables to detern.ine the state of a fluid following an isenthalpic throttling piocess at low temperatures and pressure.
S_ectica B Applying surveillance requirements to determine battery operability.
Determining Tech. Spt:. actions for failure of a hydrogen recombiner and a 480V emergency bus.
Plant Walk-Throuah Exam None (with exception of one unsatisfactory individual).
Simulator Exa.
None (with exception of one unsatisfactory crew).