_, _,,,,,,,,,

I

<s F.ntergy Operations. inc.

===~ ENTERGY R. F, Durski W31/1 016 G A-1. 05 QA October 14, 1991 U.S. Nuclear llegulatory Conunission ATTN: Doctunent Control Desk Washington, D.C. 20555 Su bject :

Waterford 3 SES Dochet No. f J-382 License No. N1'F-38 Monthly Operating lleport Gentleinen:

Attached is the subject inonthly report whleh covers the operating statistics for the nionth of Septeinber,1991. This report is submitted per Section G.9.1.G of the Waterford 3 Technical Specifications for Facility Operating License No. N1'F-38.

Very truly yours, J(

u. /.

Ill'B /TJG /ssf Attuelunent ee:

It.D. Martin, NitC llegion IV D.I,. Wiggluton, NitC-Nltit 11.11. McGehee N.S. Iteynohls J.T. Wheelock (lNI'O llecords Center)

NitC Ilesident Inspectors Office i

g{U)'

9110160063 910930 I

p eon no,xu Os000m R

PDR u

.. _ ~,.. - ~.. -.

~

7

.?.::i:..

e I

-NRC HONT11LY' OPERATING REPORT SUr&lARY OF OPERATIONS WATERFORD 3.

SEPTEMBER 1991 1

The-' unit operated at an average reactor power of 99.8% and experienced no shutdowns or significant power rcductions during the period.

P L

E t

3

(

r L

W310204H

PRESSURIZER SM'ETY VAINE FA11.URES AN1) CllA1.i1NGES VATERI ORI) 3 I)uririg the month of September 1991, there +:ere no pressurizer safetsj valve failures or challenges.

W310204Ii

.. ~....

.. _. _. y.

..... _ - _. _ ~ _..... -.. _

OPERATINGDATAhEPORT'

[

e..

UNIT NAME: WATERFORD 3 CITY /STATIO KILLONy LA _,

DATEt-OCTOBElk:1991 t

OPERATING STATUS 1

~~ ~ ~~

1.- Docket: 50-382' Hot e'i i

2.-Reporting Periodi SEPTEMBER 1991

13. Utility

Contact:

= PATRICK CENT 0LANZI

+

Phone Number: ]504).739-6683 l

4. Licensed' Thermal Power-(MWt): 3390
5. Nameplate Rating (Gross"Mwe): 1200 J6. Design Electrical Rating (Net MWe): 1104 17.' Maximum. Dependable-Capacityi(Gross MWe):-1120-h
8. Maximum Dependable Capacity (Net MWe): 1075
9. If Changas Occur in' Capaci+" Ratings (Items Number 4 Through 8) Since Last. Report, Give Reasons:

10.

Power Leve1L To Which Restricted,- i f Any (Net 'MWe):

NONE

ll.

Reasons - For Restrictions, I f. Any: N/A This Month Y r. - to-Da te Cumulative L12. -Hours In Reporting Period 720-6,551 52,752

-13. -. Number Of Ilours Reactor Was Critical 720 4,810d 42,902.8 14.

Reactor' Reserve Shutdown Hours -15' Hours Generator On-Line 720 4,698.2 42,206.1 16.

Unit Reserve Shut.down Hours '

W310204B

=..

?

at i

Gi'ERATING DATA REPORT (Continued) v This Month Yr.-to-Date Cumulative.

'17.

Cross;. Thermal Energy 2.435.284 15,641,289 138,270,082 Generated (EH)=

e-I 18._ Cross-Electrical-Energy 814,530 5,180,160 46.424.830 Cenerated (ET);-

19. Net Electrical Energy 778.309

_ 4,930,030 44.204,547

Generated L 06H) -

~20.

Unit Service Factor-100.0 71.7-80.0 21.

Unit Availability Factor-100.0 71.7 80.0

-22.

Unit Capacity Factor 100.6 70.0 78.0 (Using MDC Net) 23.

Unit Capacity Factor 97.9 68.2

-75.9

~(Using. DER Net)-

24.

Unit. Forced Outage Rate 1.9 4.4

+

i 25._ ' Unit Forced Outage Hours 91.0 1.950.5

-l

'26.

Shutdowns-Scheduled Over Next 6 Months (Type, Date, and Duration of Each):

27. "If Shut Down At End of Report Period,-Estimated-Date Of'Startup:

28..-Units In Test Status (Prior to Commercial Operation):

Forecast

. Achieved INITIAL CRITICALITY 3/4/85 INITIAL ELECTHICITY 3/18/85 CO!ERCIAL OPERATTON 9/24/85 i . W3102d4B-- a -. <,n.

. -. ~.. -. - - - -. ~ -....._.. ~ --~

.i ;;.<

'i AVERAGE DAILY UNIT POWER LEVEL l DOCKET NO. 50-382 UNIT WATERFORD 3 DATE. OCTOBER 1991 COMPLETED BY PATRICK CENTOLAN7,1 TELEP110NE 504-739-6683 NONTH SEPTEMPER 1991- .I DAY ~ AVERAGE DAILY' POWER LEVEL DAY AVERAGE DAILY POWER LEVEL (MWe-Net) (MWe-Net.) 1 1082 17 1077 2 1081' 18'- 1078 3-1081 19 1079 4 1085 20~ 1079 5 1084 21 1082 6 1084 22 1081 7

1084 23 1082
8

-1082-24 1082-9 1083 25 1084 10 1082-26 1086 11 1080 -27 1088' 12-1081 28 1055 13 1076 29 1088 .14 -1080 30 1089 15 - 1076' 31 N/A-16 l'077 INSTRUCTIONS-On this format, list the average daily unit power level in MWe-Net I,c cach day in the reporting month. Compute to the nearest whole megawatt. i W310204B f

t _L UNITT SHUTDOWNS AND POWER REDUCTIONS l 0 REPORT FOR SEPTEMBER 1991 DOCKET N0'. 50-382 UNIT NAME WATERFORD 3 DATE: OCTOBER 1991 COMPLETED BY-. PATRICK CENT 0LANZI' ~ r TELEPHONE 504-739-6683- ' Method of-Licensee Cause &' Corrective. Duration Shutting-Event System

Component Action'to.

No. Da_te Type (IlOURS) REASON 2 Down Reactor 3' 4 ' Code 5' ' Prevent Recurrence 3 Report # Code NONE 1 2 3 F: Forced Reason: Method S: Scheduled A-Equipment Failure (Ext ain) 1-Manual-B-Maintenance or Test 2-Manual Scram. C-Refueling: 3-Automatic Scram. D-Regulatory Restriction-4-Continuation 4 E-Operator" Training:&- -S-Load Reduction IEEE Std. 805-1984 License Examination 9-Other 5 F-Administrative' -IEEE Std; 803A-1983 G-Operational Error.(Explain) H-Other (Explain)' W310204B h- ..1_.}}