Forwards Comments on Code Interpretation of Steam Flow Restrictor Nozzles
ML20084V272
Person / Time
Site: Dresden 
Issue date: 09/17/1969
From: Campbell L
PARAMETER, INC.
To: Engelken R, Kornblith, Pomeroy D
US ATOMIC ENERGY COMMISSION (AEC)
Shared Package
ML19289B413 List:
References
96009, NUDOCS 8306291011
Download: ML20084V272 (1)


Text

I O

O P. s-i., L.

Design - Analysis Development Consulting Engineers 13545 WATERTOWN PLANK ROAD, ELM GROVE, Wi$ CON $lN 53122 786-7580 September 17, 1969 United States Atomic Energy Commission Division of Compliance Washington, D. C.

20545 Distribution:

Copies:

Mr. L. Kornblith, Assistant Director (2) for Technical Programs Mr.

D. L. Pomeroy, Technical Programs Mr. R. H. Engelken, Assistant Director (1) for Inspection and Enforcement

Reference:

Contract AT(11-1)-1658, Task A Consulting Services Gentlemen:

Transmitted herewith for distribution as indicated above are copies of the following:

Letter to H. D.

Thornburg i

Comments on Code Interpretation of Steam Flow Restrictor Nozzles for Dresden, Unit 2 - Report No. DC-49a September 17, 1969 by R.

A. Lofy.

%'f%gr a

2N8$s.lc very truly yours, J/g PARAMETER, Inc.

$8 M

c>c 9$

L. C. Campbell-L

$e 3

l 38 1cc 1

ca#

cc:

68-69A file 3 C003 DC-49a file a.a.

o

~

..