Comrh?!!h Edison (7

f'C Y Ourd 'MsGer.erating Station Lj

~

Post office Box 216 NW~7 coreova. iii nois 6i242 Telephone 309/654-2241

,?,.s' N

l% y NJ K-75-222

/

April 25, 1975 d'

N.

s Mr. J. F. O' Leary, Director Tl.~', ' '

~

Directorate of Licensing U. S. Nuclear Regulatory Commission Washington, D. C.

20545

Subject:

Inspection of shock suppressors at Quad-Cities Nuclear Power Station's Unit Two, AEC DKT 50-265, DPR-30.

Dear Mr. O' Leary:

The purpose of this letter is to report the results of a hydraulic shock sup-pressor inspection which was completed on April 24, 1975 Four Parker-Hannafin, thirty-three Bergen-Patterson and sixteen Grinnell Shock Suppressors were in-spected. All shock suppressors were found to be in good condition and with satisfactory reservoir oil levels.

During the Unit Two refueling outage, four additional Bergen-Patterson shock suppressors were installed. These shock suppressors give structual support ta

  • 6 n ~1y taet=11ed Terget D.eek " !n Ste - ?:fety D.e!!c# Ced!n:tien / !fe 2-203-3A.

Furthermore, all of the installed Bergen-Patterson shock suppressors were rebuilt using ethylene propylene seal gaskets for more reliable service.

Very truly yours,

~

COMMONWEALTH EDISON COMPANY QUAD-CITIES NdCLEAR FC./ER STATION

/

7 fa Y

N.J. Kalivianakis Station Superintendent NJ K/PC/vmm cc:

J.S. Abel 8306290715 750505 DR ADOCK 05000254 PDR N5SN

' COPY SENT REGION m