,_

~ s.a.s ma iele ' ram ~ ~

b mestern union w

e l

\\

f^ D G F:1 4 gg 352P EST MAY 8 72 DEB 623

<-icy SSE249 DE CCC094 (CH 129CC601094)PD UU JOL 0126P EDTOS/08/y v v) 2 2C2C 1 NL PD MORRIS ILL t1AY 4 415P CDT

) k MR BOUCE GRIER, DIRECTOR REGION 3 COMPLIANCE h

q US ATOMIC ENERGY COMM 799 ROOSEVELT RD GLEN ELLYN ILL 60137 uf 9

BT boM N

O Nci G Q

(

m D P R 25 DRESDEN NUCLEAR POUER STATION UNIT 3:

gz g

THIS WILL CONFIRM C0tNERS ATION AT 15:00 IIRS THIS DATE WITH H DANCE W '~ U I

b TOOPENbf;$h REGARDING F AILURE OF Tile ISOL ATION CONDENSOR V ALVE 3-1301-3

[k ELECTRICALLY FOLLOUING A REACTOR SCRAM. IMMEDIATELY FOLLOWING l

THE' SCRAM WHICH OCCURRED AT 0901 HRS A GROUP 1 ISOL ATION OCCURED 33[r BEC AUSE OF A IIIGH W ATER LEVEL CONDITION.

dd$ k AN AT'IEMPT WAS t1ADE TO PL ACE D{E ISOL ATION CONDENSOR IN SERVICE u -

BUT V ALVE 3-1301-3 WOULD NOT OPEN. AN OPERATOR HAD' TO GO TO DIE V ALVE g

i SF-1201 (R5-69)

/

B306270072 720603 PDR ADOCK 05000249 i

P pgg AND M ANUALLY CRAKE THE V ALVE OFF ITS SEAT. ONCE DIE V ALVE WAS OPEt:ED ITS BREAKER RE-SET AND IT FUNCTIONED PROPERLY.

WHILE THE OPERATOR WAS WORKING ON PL ACING THE ISTL ATION CONDENSOR IN SERVICE REACTOR PRESSURE INCREASED TO APPROXIMATELY 1100 PSIG AT THIS PRESSURE 3 A ELECTROMATIC V ALVE OPENS AUTOM ATIC ALLY.

WHEN TIIE ELECTROMATIC VALVE OPENED THE DRYWELL PRESSURE IMMEDI ATELY I NCRE ASED TO 2. 5 PSIG. AFTER PEAKING AT 2 5 PSIG ' DIE DRYWELL PRESSURE RETURNED TO NORMAL.

A COMPLETE DRYWELL INSPECTION WILL BE MADE WHEN ENTRY IS POSSIBLE

\\

TO DETERMINE TIIE C AUSE OF THE PRESSURIZ ATION AND TO DETERMINE IF ANY EQUIPMENT HAS BEEN DAMAGED AS A RESULT OF THIS PRESSURIZ ATION i

IN ADDITION A COMPLETE CHECK-0UT WILL BE MADE ON VALVE 3-1301-3

{

C 85 20Fa51HE ISOL ATION CONDENSOR TO DETERMINE WHY IT F AILED TO O b