p g s,.,

Philadelphia Electric Company Limerick Generating Station Meteorological Tower 1 Data NRC Tape Format (SER NO. 56619)

Collection Period 10/15/83-4/15/84 Dats Description Format Coldmns ID Number (000021)

I6 6 Year 12 7-8 Julian Day 13 9-11 Hour I4 12-15 Upper Wind Height (m x 10) (823) 15 16-20 270-Ft. Wind Direction ('Az x 10) 15 21-25 270-Ft. Wind Speed (m/sec x 10) 15 26-30 Turbulence Class

  • 15 31-35 15X 36-50 Spaces (533) 15 51-55 Intermediate Wind Height (m x 10) 175-Ft. Wind Direction ('Az x 10)

I5 56-60 175-Ft. Wind Speed (m/sec x 10) 15 61-65 175-Ft. ' Sigma Theta (degrees x 10) 15 66-70 Spaces 15X 71-85 Lower Wind Height (m x 10) (91)

IS 86-90 30-Ft. Wind Direction ('Az x 10) 15 91-95 30-Ft. Wind Speed (m/see x 10)

I5 96-100 30-Ft.. Sigma Theta (degrees x 10) 15 101-105 26-Ft. Ambient Temperature ('C x 10) 15 106-110 Dew Point Temperature ('C x 10) 15 111-115 Spaces 5X 116-120 266-26 Ft. Delta Temperatue ('C/100 m x 10)

I5 121-125 5X 126-130 Spaces

_ Delta Temperature ('C/100 m x 10) 15 131-135 171-26 Ft.

Precipitation (mm x 10)

IS 136-140 Satellite Wind Height (m x 10) (98) 15 141-145 Satellite Wind Direction ('Az x 10) 15 146-150 Satellite Wind Speed (m/see x 10) 15 151-155 Satellite Sigma Theta (degrees x 10) 15 156-160 Turbulence Classification System (Gustiness) 1=

Very Unstable 2=

Slightly Unstable 3=

Moderately Unstable 4-Neutral 5=

Stable JRE/dg/D/3 8405180127 040515 PDR ADOCK 05000352 R

pg

r-y,'$

d-c cc: Judge Lawrence Brenner (w/o enclosure)

Judge Richard F. Cole (w/o enclosure)

Troy B. Conner, Jr., Esq.

(w/o enclosure) g Ann P. Hodgdon, Esq.

(w/o enclosure)

Mr. Frank R. Rmano (w/o enclosure)

Mr. Robert L. Anthony (w/o enclosure)

Charles W. Elliot, Esq.

(w/o enclosure)

Zori G. Ferkin, Esq.

(w/o enclosure)

Mr. Thamas Gerusky (w/o enclosure)

Director', Penna. Emergency (w/o enclosure)

Management Agency Angus R. Inve,. Esq.

(w/o enclosure)

David Wersan, Esq.

(w/o enclosure)

Robert J. Sugarman, Esq.

(w/o enclosure)

Spence W. Perry, Esq.

(w/o enclosure)

Jay M. Gutierrez, Esq.

(w/o enclosure)

Atcmic Safety & Licensing (w/o enclosure)

. Appeal Board Atomic Safety & Licensing (w/o enclosure)

Board Panel Docket & Service Section (w/o enclosure)

Martha W. Bush, Esq.

(w/o enclosure)

Mr. James Wiggins (w/o enclosure)

Mr. Timothy R. S. Canpbell (w/o enclosure)

Ms. Phyllis Zitzer (w/o enclosure)

Judge Peter A. Morris (w/o enclosure)