ML20084L765

From kanterella
Jump to navigation Jump to search
Ro:On 740722,during Testing,Lpci Pump Suction Valve MO-3-1501-5A Failed to Close.Caused by Disc That Over Traveled in Open Direction & Became Cocked in Valve Guides. Valve Disc & Operator Realigned in Valve Guides
ML20084L765
Person / Time
Site: Dresden Constellation icon.png
Issue date: 07/29/1974
From: Stephenson B
COMMONWEALTH EDISON CO.
To: Oleary J
US ATOMIC ENERGY COMMISSION (AEC)
References
544-74, NUDOCS 8305230702
Download: ML20084L765 (2)


Text

h One rest %bew P>nt)calth Edison -

O Comm; 7;

CNcago.1:: nr>is

,. m:

.A

/,7, Address Rcp;y to: Post Off.cc Box 767

/M~

Chicago, Illinois 6Ws0-T,-

n..% - j ',_!p BBS Ltr.0544-74 1/ /Qf7 ,'[ # !]).

A Dresden Nuclear Power Station b

g",

tijg o R. R. #1 Tg

'/

p7 - f, ' Morris, Illinois 7

60450

',e July 29, 1974 y

(>4 0

h,y.y,

%:.-J. j.. ;,3. \\ -

Mr. J. F. O' Leary, Director

- Directorato of Licensing U. S. Atomic Energy Ccenission Washington, D. C.

20545

SUBJECT:

MPORT OF UNUSUAL EVENT PER SECTION 6.6.B.2 0F THE TECHNICAL SPECIFICATTONS.

l,0W PPESSUP2 COO!.A!(f INJECTION PUMP SUCTION VALVE 3-1501-5A PAIIED TO CLOSE.

References:

' 1) Regulatory Guide 1.16 Rsv.1 Appendix A

2) Drawin'g P&ID M-360 Report Date: July 29, 1974 Cecurrence Date: July 22,1974 racility: Drcsden 14ucicar rower station, riorris,1111nois TDENTIJICATION OF OCCURRENC_E During testing, LPCI pump suction valve MO-3-1501-5A failed to close.

10NDITIONS PRIOR TO OCCURPENCE Prior to thin ti::c, the reactor was at power and producing 680 1510. Testing of LPCI valves was in progress to fulfill a requirement for an upcoming diccel generator outage.

DESCRIPTION OF_OCCURRENQ

'On July 22,.1974 a close cignal van supplied to_ valve 3-1501-5A.

It came off its open seat then bound up and stopped.. The valve was then opened fully and a work request was submitted to inspect and repair it.

l

..\\

4

\\

!, 'll

. C. S '

t I b"*'(I <

e30523o7o2 740729 t

.[DRADDCK 05000237-

(( o%

PDR

. COPY SENT REGION w

..~

O au1x29.1m Mr. J. F. 'O'L2 cry DESTCNATIO!! 0F APPAREITT CAUSE OF OCCURRENCE Upon inspection of valve 3-1501-5A it was fcund that the disc had overtraveled in the open direction and became cocked in the valve guides.-

ANALYSIS OF_ OCCURRENCE Since the valve is required to be in the open position for LPCI operability, 'at no time was the plant or public ' health and safety compromised in any way.

CORRECTIVE ACTIO3 1

The valve disc and operator were realigned in the valve guides and the valve checked for free operation. To prevent a repetition of this s

occurrence, the valve stroke was adjusted per vendor manual and overtravel is no longer possible.

FAILURE DATA System Number 3-1501-5A lisnufaeturer Crane Company Medal W ab -

4 ?t.sf P.

Type

.Gato Sizo 14" operator li. 0.

Research has turned up no previo'un failure'of this type in this system.-

Sincerely, if wt II

- D. B. Stephenson i

Superintendent BBS:GIZ:do

[

I k.

_. _ _