f ConsumerJ Power James W Cook Vice President - Projects, Engineering and Construction General offices: 1945 West Parnell Road, Jackson, MI 49201 e (517) 788 0453 April 30, 1984 84-05 #1 Mr J G Keppler, Regional Administrator US Nuclear Regulatory Commission Region III 799 Roosevelt Road Glen Ellyn, IL 60137 MIDLAND ENERGY CENTER PROJECT DOCKET NOS 50-329 AND 50-330 TRANSAMERICA-DELAVAL DIESEL GENERATORS FILE:
0.4.9.92 SERIAL: 30261 On March 29, 1984, Consumers Power Company notified your staff of two potential 10CFR50.55(e) conditions involving Transamerica Delaval diesel generators:
Piston Skirt Casting Defects and ASME Section III related audit findings.
An additional concern, involving lubrication of the turbocharger thrust bearing, also was discussed. This letter is an interim 10CFR50.55(e) report.
Because of the relatively high number of 10CFR21 reports filed by Transmerica Delaval and the significance of problems uncovered at other jobsites, Consumers Power Company instituted a Midland Project Diesel Generator Task Force in October 1983.
In January,1984 Consumers Power Company joined an Owners Group of utilities that had purchased Transamerica Delaval diesel generators. Both these efforts have been directed toward recommending solutions to known diesel generator problems and anticipating problems which may not have emerged.
For Consumers Power Company, the Diesel Generator Task Force serves as the focus for evaluating recommended solutions from all sources and for incorporating them within approved project design and quality systems.
Because of the potential 10CFR50.55(e) conditions, known 10CFR21 reports and problems from other utilities will be reevaluated within the context of the 1
Diesel Generator Task Force. A reevaluation status of these problems will be provided in the next report.
In addition, the next report will provide the outline of a systematic review of the design and manufacturing adeq 6cy of important diesel generator components. This systematic review is aimed at identifying design or manufacturing problems that have not been discovered.
8405140372 840430 PDR ADOCK 05000329
/>'b S
PDR g
g 1984 OC0484-0033A-MP01
y 84-05 #1 Serial 30261 Another repore, either interim or final, will be sent on or before July 27, 1984.
L JKC/AHB/cd CC: RJCook, NRC Resident Inspector Midland Nuclear Plant Document Control Desk, USNRC Washington, DC DSHood, Office of NRR USNRC, Washington, DC INPO Records Center t
OC0484-0033A-FJ01
OM/0L SERVICE LIST Mr Frank J Kelley.
Atomic Safety & Licensing Attorney General of the Appeal Board State of Michigan U S Nuclear. Regulatory Commission Ms Carole Steinberg Washington, DC 20555 Assistant Attorney General Environmental Protection Division Mr C R Stephens (3) 1720 Law Building Chief. Docketing & Services Lansing, MI 48913 U S Nuclear Regulatory Commission Office of the Secretary Washington, DC 20555 Mr Myron M Cherry, Esq Suite 3700 Ms Mary Sinclair Three First National Plaza 5711 Summerset Street Chicago,11L 60602 Midland, MI 48640 Mr Wendell H Marshall Mr William D Paton, dsq RFD 10 Counsel for the NRC Staff
' Midland, MI 48640 U S Nuclear Regulatory Commission Washington, DC 20555.
Mr Charles Bechhoefer, Esq Atomic Safety =& Licensing Atomic Safety & Licensing Board Panel Board Panel U S Nuclear Regulatory Commission U S Nuclear Regulatory Commission East-West Towers, Room E-413 Washington, DC 20555 Bethesda, MD 20014 Ms Barbara Stamaris Dr Frederick P Cowan 5795 North River Road 6152 N Verde Trail Rt 3 Apt B-125-Freeland, MI 48623 Boca Raton, FL 33433 Dr Jerry Harbour Mr Fred C Williams Atomic Safety & Licensing Isham, Lincoln & Beale
. Board Panel 1120 Connecticut Ave, NW, Suite 840 U S Nuclear Regulatory Commission Washington, DC 20036 East-West Towers, Room E-454 Bethesda, MD 20014 Mr James E Brunner, Esq Consumers Power Company Mr M I Miller, Esq 212 West Michigan Avenue Isham, Lincoln & Beale Jackson, MI 49201 Three First National Plaza 52nd Floor Chicago, IL 60602 OC0484-0033A-MP01
^
_'s a
84-05 #1 Serial 30261 m,
Mr D F Judd Babcock & Wilcox' PO Box 1260 Mr John Demeester, Esq Lynchburg, VA 24505 Dow Chemical Building Michigan Division Mr Steve Gadler, Esq
. Midland MI 48640 2120 Carter Avenue St Paul, MN 55108 Ms-Lynne Bernabei Government Accountability Project Mr P Robert Brown 1901 Q Street, NW Clark, Klein & Beaumont Washington, DC 20009 1600 First' Federal Bldg Woodward Ave Detroit, MI 48226 3/14/84 e
OC0484-0033A-MP01