f?eh' of Ould4 Comir v Elth Edizn
,,' {( ' ;"- !
. Gcncratng Station Po;,t Of:.ce Box 216 x
., M 07 Cordova,lilir.ois 61242 Telephone 303/654-2241
~
'N
- 0. ',,,.,
Q lj fW&lGA$0 &
NJI-7h-333
,i I,
b//
l_ g;
-(
(',
Q i' 9 hs/
October 18, 1974
.R
,//
3;,
- [ e Mr. J. F. O' Leary, Director f
Directorate of Licensing v' mf U. S. Atomic Enerry Commission Washington, D.C.
20545 n
SUBJECT:
Inspection of Shock Suppressors at Quad-Citics Nuclear Power Station, Unit 1, AEC Docket 50-254, DHt-29
Dear Mr. O' Leary:
The purpose of this letter is to report the results of a Hydraulic Shock Suppressor inspection which was conducted on October 4,1974 on quad-Cities Unit 1.
Four (4) Parker-Hannafin, 33 Bergen-Patterson, and 14 Grinnell Shock Suppressors were inspected.
All Grinnell and Parker-Hannafin Suppressors contained sufficient fluid and appeared to be in acceptable condition. Ho fluid leakage was present with renpect to any of these suppressors.
Pergen-Patterson Shock Suppressors Sarial Numbered F-61284-1 (Tag 1 -21 ),
402594 (Tac 1-Ph), and 68290 (Tar; 1-13), uere found to contain insufficient quantities of hydraulic oil in their respective reservoirs. All other suppressors were observed to be satisfactory.
The three ch'ective Percen-Patterson Shock Suppressors were removed and disansembled.
Inspection revealed the cause of the leakage in one suppressor to be a small chip out of the rod packing. This chip, about one-sixteenth of nn inch, was believed to be caused in the installation of the packing, j
The cause of the necond suppressor fluid loss was determined to be a nut on an accumulator tie rod that was not torqued down properly. No apparent cause could be found for the third suppressor's lors of fluid.
Very truly yours, A
./ /. /
/
k ;'" 0.'4.hsin ';Q:'([
~~~
'N. J. Kalivianakis Station Superintendent NJK/ LPG /rhb 5b '[e/'
p V.
{}
8305190123 741018
{DRADOCK 05000254 PDR COPY SENT REGION m
>