From:

Holonich, Joseph To:

"McGruder, Wynter" Cc:

Morey, Dennis; Gonzalez, Hipo; Dijamco, David; Rudland, David; Fields, Leslie

Subject:

Transmittal of BWRVIP-329 Requests for Additional Information Date:

Monday, May 11, 2020 3:01:36 PM

Wynter,

I have placed an electronic version of the Requests for Additional Information (RAI) questions for BWRVIP-329, "Updated Probabilistic Fracture Mechanics Analyses for BWR [Boiling Water Reactor]

RPV [Reactor Pressure Vessel] Welds to Address Extended Operations," in the box.com folder and have given you access to it. This email serves as the formal transmittal of those RAI questions.

The staff has not redacted any proprietary information from the RAI questions so the file in the Agencywide Documents Access and Management System (ADAMS) and box.com are marked as proprietary. The RAI questions have also been placed in ADAMS as nonpublic so they can be declared an Official Agency Record. When responding to the RAI questions, please provide a proprietary and nonproprietary version of both the RAI questions and the responses. Your formal response, provided via letter under authorized signature, will generate the public version of the RAI questions as well as the responses.

In order to support the staffs review schedule, please provide your responses no later than November 30, 2020. This date was provided by you based on the need to obtain ISP capsule testing before the RAI questions can be answered. However, as we discussed, once the BWRVIP has time to review the RAIs in detail, you may ask for additional time to respond.

If you have any questions or would like to discuss the RAI questions with staff to ensure you understand them, please let me know. If the interaction is limited to clarification and administration, we do not need to notice it. If the BWRVIP would like to discuss the RAIs in detail, we would need to notice the interaction although we could close it if proprietary information was discussed.

This email will also go in ADAMS and will be declared public.

Joe Holonich, Senior Project Manager Office of Nuclear Reactor Regulation U.S. Nuclear Regulatory Commission 301-415-7297 jjh1@nrc.gov