ML20084F691
| ML20084F691 | |
| Person / Time | |
|---|---|
| Site: | Quad Cities |
| Issue date: | 04/23/1984 |
| From: | Kalivianakis N COMMONWEALTH EDISON CO. |
| To: | Harold Denton Office of Nuclear Reactor Regulation |
| Shared Package | |
| ML20084F695 | List: |
| References | |
| NJK-84-143, NUDOCS 8405040283 | |
| Download: ML20084F691 (1) | |
Text
=.
Commonwealth Edison C
Outd Citiss Nucl2tr Powsr Station Q-22710 206 Avenue North Corcova, Illinois 61242 Telephone 309/654-2241 NJK-84-143 April 23, 1984 Mr. Harold Denton Director Nuclear Reactor Regulation U. S. Nuclear Regulatory Commission Washington, D.C.
20555
SUBJECT:
Reactor Containment Building Integrated Leak Rate Test Quad-Cities Nuclear Power Station Docket No. 50-265, DPR-30, Unit Two Enclosed please find the report " Reactor Containment Building Integrated Leak Rate Test, Quad-Cities Nuclear Power Station, Unit Two, February 9-10, 1984" and the related appendices describing the Type A test. The performance of this test was witnessed and inspected by the Quad-Cities resident inspector as a representative of the NRC Region III Office.
This report is submitted to you in accordance with the requirements of 10 CFR 50, Appendix J, Section V.B.1.
The information contained in Appendix A of this report is intended to comply with requirements of 10 CFR 50, Appendix J, Section V.B.3.
According to 10 CFR 50, Appendix'J,Section III.A.6, the test' schedule for the next Type A test is to be reviewed and approved by the Commission. The next Type A test for Quad-Cities Unit Two is scheduled for the fall of 1986; the Commission's review and approval of this schedule is hereby requested.
Very truly yours, COMMONWEALTH EDISON COMPANY Quad-Cities Nuclear Power Station
/
/
['
// '
N. J. Kalivianakis Station Superintendent NJK/EEM/aaa 8405040283 840423 h
Attachment.
fDRADOCK 05000265 R
~
-