_ _ _ _ _ - _ _ _

q, A

5

^

r Ofl uitL-ili 0i :11:!tilo w

(,

1216P EST MAR 6 70 PBill SYF121 O

SY RHC05s CS PDF s' EXTRA ROCHESTER NY 61132A EST R V KIRKMAN, DIRECTOR REGION NBR I DIV 0F COMPLIANCE USAEC 90 DROAD ST NEUARK NJER THIS IS TO CONFIRM MY COINERSATION OF 1000 THIS DATE HUNNICUTT IN RECARDS TO AN ABNORMAL OCCURENCE THA O

THIS MORNING UHEN UE DID OUR SURVEILLENCE TEST OF l

THE EQUIPMENT HATCH. AT 0600 THIS MORNING THE TE C

AIRLOCK IN INDICATED EXCESSIVE AIR LEAKAGE ALONG THE SHAFT T TO THE OUTSIDE AND INSIDE HAND CONTROL UHEELS. REPAIRS

'O STARTED IMMEDIATELY AND UILL CONTINUE AROUND THE C TO DISCUSS C

COMPLETED. PORC COMMITTEE WILL MEET THIS AFTERNOON

' THE PROBLEM CHARLES E PLATT SUPERINTENDENT CINNA STATION ROCHESTER O

AND ELECTRIC CORP d,

/

.M sstattasam k/w M t

1 b

j 1000 0800 PORC C

O

< 3 a t),

C jO

\\

/

o
O 50 8304150353 700313 i b-PDR ADOCK 05000244 i

S PDR O sFtat(ms44 e.

+ owe =

,**wem

  • -e-es m!

l 4

9' l

MEMO ROUTE SLIP d

S** me aw th'*-

    • c=arr F= =ct'a-Form AEC-95 (Rev. May 14,1947) AECM 0240 Note and return.

For signature.

For information.

i TO (Name and unit)

HETIALS REMARKS h

'J.

P. O'Reilly, Chief ROCHESTER GAS AND ELECTRIC COMPANY Reactor Inspection anc Enforcement Branch, cATE The attached telegraphic report from RG&E is for-CO:HQ warded in accordance with PI 1000/3. The incident was also discussed in Inauiry Memorandum 244/70-C.

TO (Narne and unit) af4TIALS REMARKS DATE TO (Name and unit)

UGDALS REMARKS t

i cATE

'i 2Ns'[lh,$$.Y

~"

Reactor Inspector, C0:I i.,T e

/

n /

?

~ D942 "2/6/70 ['

U5E;"~ ' NDE FOR ADDIT *J' Z "* MARKS I

I l