Commonw;sith Edison

) One First Nabonal Plaza. Chicago. Ilknois o

C ] Address Reply to: Post Office Box 767 g

Chicago. Illinois 60690 April 19, 1984 Mr. James G. Keppler Regional Administrator U.S.

Nuclear Regulatory Commission Region III 799 Roosevelt Road Glen Ellyn, IL 60137

Subject:

Quad Cities Station Units 1 and 2 Supplemental Response to IE Bulletin 83-07 "Apparently Fraudulent Products Sold By Ray Miller, Inc."

NRC Docket Nos. 50-254/265, References (a):

IE Bulletin No. 83 R. C. DeYoung letter to All OLs and cps dated July 22, 1983 (NL-83-0035)

(b):

IE Bulletin No. 83-07 Supplement 1 - R. C.

DeYoung letter to All OLs and cps dated October 26, 1983 (NL-83-0462)

(c):

IE Bulletin No. 83-07 Supplement 2 - R.

C.

DeYoung letter to All OLs and cps dated December 9, 1983 (NL-83-0695)

(d):

P. L.

Barnes letter to J. G. Keppler dated March 20, 1984 (NL-84-0318)

Dear Mr. Keppler:

Reference (a) requested that the Commonwealth Edison Company provide a written report regarding our review of records for receipt of apparently fraudulent materials sold by Ray Miller, Inc.

Reference (d) provided that report.

Based upon further review we find it necessary to amend the

-Quad Cities response included in Reference (d).

Four 10-inch, 900 lb., schedule 80 flanges were purchased from Midland Pipe & Supply Company _in 1978.

It.has been determined that these flanges were procured by Midland from Ladish. Company.

This msterial,.therefore, has-no connection with Ray Miller, Inc.

.)

G ~

d

2
se n

l To the best of my knowledge and belief the statements contained in the Attachment are true and correct.

In some respects these statements are not based on my personal knowledge but upon information furnished by other Commonwealth Edison employees, consultants, and contractors.

Such information has been reviewed in accordance with Company practice and I believe it to be reliable.

Please address any questions that you or your staff may have concerning our response to IE Bulletin No. 83-07 to this office.

One (1) signed original with Attachment is being sent directly to the USNRC Document Control Desk in Washington, DC for reproduction and distribution as requested in the Bulletin.

Respectfully, k$.

P. L. Barnes Nuclear Licensing Administrator Attachments cc:

U.S. NRC, Document Control Desk Washington, DC 20555 RIII. Inspectors - QC 3

SUBSCRIBED and SWORN to before me this

/ 9-rlJay I

of G ZAll,

1984 Ot%hlOZ?&ida **

. Notary Public 8288N

- -