ML20083Q092

From kanterella
Jump to navigation Jump to search
Forwards Books 1 & 2 of LGS Unit 2 Summary Rept for 930317- 950219 Periodic ISI - Rept 3
ML20083Q092
Person / Time
Site: Limerick 
Issue date: 05/19/1995
From: Walter MacFarland
PECO ENERGY CO., (FORMERLY PHILADELPHIA ELECTRIC
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
Shared Package
ML20083Q095 List:
References
NUDOCS 9505250102
Download: ML20083Q092 (1)


Text

-y s

J, Weiter c. MaiFtrland. IV, P.E.

D W:e Prrsident Umerick G:nerating Station PECO ENERGY.

g g g omae"v e

Sanatoga, PA 194644)920 610 718 3000 Fax 610 718 3008 Pager 1800 352 4732 #8320 T.S. 4.0.5 10 CFR 50.55a (g)

May 19,1995 Docket No. 50-353 Ucense No. NPF-85 i

U.S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, DC 20555

SUBJECT:

Umerick Generating Station, Unit 2 Summary Reports for Inservice Inspections and ASME Section XI Repairs and Replacements Enclosed are the reports:

1)

Umerick Generating Station, Unit 2 Summary report for the March 17,1993 to February 19,1995 Period inservice inspection - Report No. 3.

2)

Umerick Generating Station, Unit 2 Summary of ASME Section XI Repairs and Replacements completed from March 17,1993 to February 19,1995 - Report No.3 These reports are being submitted pursuant to Technical Specification Surveillance Requirements 4.0.5 and 10CFR50.55a(g).

If your have any questions, or require additional information, please do not hesitate to contact us.

Very truly yours, 6.

k, W

Enclosures 9505250102 950519 PDR ADOCK 0500o353 Q

PDR cc:

T. T. Martin, Administrator, Region I, USNRC N. S. Perry, USNRC Senior Resident inspector, LGS 8I

' l{t

-