ML20083M665

From kanterella
Jump to navigation Jump to search
First Interim Deficiency Rept Re Residual Stress on Diesel Generator Engine Piston Skirt Castings.Initially Reported on 821215.Removal of Piston Skirt for Insp Deferred Until Restart of Design & Const.Also Reportable Per Part 21
ML20083M665
Person / Time
Site: Hartsville  
Issue date: 01/24/1983
From: Mills L
TENNESSEE VALLEY AUTHORITY
To: James O'Reilly
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
REF-PT21-83 10CFR-050.55E, 10CFR-50.55E, NUDOCS 8302010417
Download: ML20083M665 (2)


Text

.

44

TENNESSEE VALLEY AUTHORITY rHATTANOOGA. TENNESSEE 374o1 400 Chestnut Street Tower II January 24, 1983 HTRD-50-518/83-02, -520/83-02

_U U.S. Nuclear Regulatory Commission e_

Region II E

,q ATTN: James P. O'Reilly, Regional Administrator Z

3

~

101 Marietta Street - Suite 3100 y

q Atlanta, Georgia 30303 E5

Dear Mr. O'Reilly:

~

HARTSVILLE NUCLEAR PLANT A - REPORTABLE DEFICIENCY - DIESEL GENEISTOR ENGINE PISTON SKIRT CASTINGS - HTRD-50-518/83-02, -520/83-02 The subject deficiency were initially reported to NRC-0IE, Region II, Inspector Ross Butcher on December 15, 1982, as NCR HTA MEB 8205. In compliance with paragraph 50.55(e) of 10 CFR Part 50, enclosed is our first interim report on the subject deficiency. We consider 10 CFR Part 21 applicable to this deficiency.

TVA has elected to defer construction activities for this praject.

Deferral does not mean that the project will be cancelled but that TVA is minimizing its expenditures and construction efforts until such time that TVA has sufficient information to indicate whether the project should be completed or cancelled. Therefore, we will not be submitting a final report for this nonconformar.ce until a final decision is made, regarding this project.

A 10-day extension on the submittal of this report was discussed with and granted by Ross Butcher on January 17, 1983 If you have any questions, please call Jim Domer at FTS 858-2725.

Very truly yours, TENNESSEE VALLEY AUTHORITY D5 M l.m.L. M. Mills, Manager Nuclear Licensing Enclosure cc:

Mr. R. C. DeYoung, Director (Enclosure)

Office of Inspection and Enforcement U.S. Nuclear Regulatory Commission Washington, D.C. 20555

'"oFFICI AL COPY 8302010417 830124 PDR ADOCK 05000510

. -; -gg S

PDR An Equal Opportunity Employer

, e.

ENCLOSURE HARTSVILLE NUCLEAR PLANT A DIESEL GENERATOR ENGINE PISTON SKIRT CASTINGS 10CFR50.55(e) FIRST REPORT (INTERIM)

NCR HTAMEB8205 HTRD-50-518/83-02, -520/83-02 Description of "eficiency There exists a potential problem with the piston skirt' castings in the standby diesel generator engines supplied to TVA by Transamerica Delaval, Inc. (TDI), of Oakland, California. The potential problem concerns the possibility of residual stress caused by the method of heat treating of the pisten. TDI has informed the NRC of this potential problem under 10CFR21 by letter dated November 28, 1982, from R. E.

Boyer, Manager, Quality Assurance to the Director, Office of Inspection and Enforcement.

Interim Progress TDI has recommended the removal of these piston skirts and their return for inspection. Defective items will be replaced by TDI.

This action, however, will be deferred until restart of design and construction.

v

'4

!f 6