Monthly Operating Rept for Apr 1995 for Wolf Creek Generating
ML20083M647
Person / Time
Site: Wolf Creek Wolf Creek Nuclear Operating Corporation icon.png
Issue date: 04/30/1995
From: Maynord O
WOLF CREEK NUCLEAR OPERATING CORP.
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
WO-95-0084, WO-95-84, NUDOCS 9505190386
Download: ML20083M647 (7)


Text

y-q

'~

'?'

1 A

W4tLF CREEK

~

NUCLEAR OPERATING CORPORATION Otto L Maynard Wce Premden: Plant Operations May 15, 1995 WO 95-0084 U.

S. Nuclear Regulatory Commission ATTN: Document Control Desk ~

Mail Station P1-137 Washington, D.

C.

20555

Subject:

Docket No. 50-482: April, 1995, Monthly Operating Report r

Gentlemen:

Attached is the April, 1995, Monthly Operating Report for Wolf Creek Generating Station.

This submittal is being made in accordance with the requirements of Technical Specification 6.9.1.8.

t Very truly yours, Otto L. Maynard OLM/jad Attachment cc:

L. J. Callan (NRC), w/a D.

F. Kirsch (NRC), w/a J. F. Ringwald (NRC), w/a J.

C. Stone (NRC), w/a

,oa +-

- L t f.: e l3

. am m / Burongt n, s e mom mem8831 l ]

9505190386 pj yjs2 PDR ADOCK PDR An Equal Opportunity Employer M/F/HCNET R

J),

Attachment to WO 95-0084 k

WOLF CREEK NUCLEAR OPERATING CORPORATION WOLF CREEK GENERATING STATION MONTHLY OPERATING REPORT MONTH:

April.

YEAR:

1995 Docket No.:

50-402 Facility Operating License No.:

NPF-42 Report No.

122 1

'Attcchment'to WO 95-0084

SUMMARY

Tha following report highlights the operating experience of Wolf Creek Generating Station for. the month of April, 1995.

This report is being provided pursuant to Technical Sp2cification 6.9.1.8.

I.

SUMMARY

OF OPERATING EXPERIENCE The unit operated at or near 100% power in Mode 1 for the month of April, 1995.

'II.

MAJOR SAFETY RELATED MAINTENANCE ACTIVITIES NONE Wolf Creek Generating Station Monthly Operating Report April, 1995 Page 1 of 5

~

Attachment to WO 95-0084 OPERATING DATA REPORT DOCKET NO. 50-482 WOLF CREEK GENERATING STAT 13N WOLF CREEK NUCLEAR OPERATING CORPORATION DATE 5-10-95 TELEPHONE 316-364-8831 OPERATING STATUS 1.

Reporting Period:

April, 1995 Gross Hours in Reporting Period:

719 2.

Currently Authorized Power Level (MWt) :

3565 Max. Depend. Capacity (MWe-Net) : 1160 Design Electrical Rating (MWe-Net) :

1170 3.

Power Level to Which Restricted (If Any) (MWe-Net) :

N/A l

4.

Reasons for Restriction (If Any) : N/A This Month Yr. to Date Cumulative 5.

Number of Hours Reactor was Critical 719 2767.7 68,735.8 6.

Reactor Reserve Shutdown Hours 0.0 0.0 339.8 7.

Hours Generator on Line 719 2,744.1 67,898.7 8.

Unit Reserve Shutdown Hours 0.0 0.0 0.0 l

9.

Gross Thermal Energy Generated (MWh) 2,543,603 9,588,002 224,620,320 l

l l

10.

Gross Electrical Energy Generated (MWh) 885,431 3,328,573 78,092,788 11.

Net Electrical Energy Generated (MWh) 849,034 3,190,443 74,565,117 12.

Reactor Service Factor 100.0%

96.1%

81.2%

13.

Peactor Availability Factor 100.0%

96.1%

81.6%

14.

Unit Service Factor 100.0%

95.3%

80.2%

15.

Unit Availability Factor 100.0%

95.3%

80.2%

16.

Unit Capacity Factor (Using MDC) 101.8%

95.5%

77.7%

17.

Unit Capacity Factor (Using Design MWe) 100.2%

94.7%

75.3%

18.

Unit Forced Outage Rate 0.0%

4.7%

5.1%

19.

Shutdowns Scheduled Over Next 6 Months (Type, Date, and Duration of each) :

No outages are scheduled at this time, l

20.

If Shut Down at End of Report Period, Estimate Date of Startup:

N/A l

Wolf Creek Generating Station Monthly Operating Report April, 1995 Page 2 of 5

s AttCchment*to WO 95-0084 AVERAGE DAILY UNIT POWER LEVEL DOCKET NO. 50-482 WOLF CREEK GENERATING STATION WOLF CREEK NUCLEAR OPERATING CORPORATION DATE 5-10-95 TELEPHONE 316-364-8831 MONTH April, 1995 DAY AVERAGE DAILY POWER LEVEL DAY AVERAGE DAILY POWER LEVEL (MWe-Net)

(MWe-Net) 1 1182 17 1182 2

1182 18 1181 3

1182 19 1182 4

1182 20 1174 5

1182 21 1101 6

1173 22 1183 7

1182 23 1184 8

1182 24 1184 9

1181 25 1183 10 1182 26 1182 11 1182 27 1176 12 1182 28 1179 13 1169 29 1183 14 1180 30 1183 15 1182 31 NA 16 1182 1

l I

Wolf Creek Generating Station Monthly Operating Report April, 1995 Page 3 of 5 i

. to WO 95-0084 UNIT SHUTDOWN AND POWER REDUCTIONS DOCKET NO. 50-482-WOLF CREEK GENERATING STATION WOLF CREEK NUCLEAR OPERATING CORPORATIOS DATE 5-10-95 TELEPHONE 316-364-8831 Type METHOD OF ShVITING F: FORCED DURATION REASON DOWN THE REACTOR CORRECTIVE ACTIONS / COMMENTS Mo Date S: SCHEDULED (Hours)

(1)

OR REDUCING POWER (2)

NA NA NA NA NA NA NA

SUMMARY

The unit operated at or near 100% in Mode 1 for the month of April, 1335.

1)

REASON: A: EQUIPMENT FAILURE (EXPLAIN)

E: OPERATOR TRAINING AND LICENSE EXAMINATION (2) METHOD:

1.

MANUAL B: MAINTENANCE OR TEST F: ADMINISTRATIVE

2. MANUAL SCRAM C: REFUELING G: OPERATIONAL ERROR (EXPLAIN)
3. AUTOMATIC SCRAM D: REGULATORY RESTRICTION H: OTHER (EXPLAIN) 4.

COITIINUED 5.

REDUCED LOAD

9. OTHER Wolf Creek Generating Station Monthly Operating Report April, 1995 Page 4 of 5 w

,a*.,

'Attcchment*1 to WO 95-0084 WOLF CREEK NUCLEAR OPERATING CORPORATION WOLF CREEK GENERATING STATION UNIT NO. 1 MONTH April, 1995

SUMMARY

OF OPERATING EXPERIENCE Listed below in chronological sequence is a summary of operating experiences for this month which required load reduction or resulted in significant non-load related incidents.

DATE' TIME EVENT NA NA NA Wolf Creek Generating Station Monthly Operating Report April, 1995 Page 5 of 5