NPDES Discharge Monitoring Rept for Apr 1995
ML20083L612
Person / Time
Site: Perry 
Issue date: 04/30/1995
From: Shelton D
CENTERIOR ENERGY
To:
OHIO, STATE OF
References
PY-CEI-OEPA-022, PY-CEI-OEPA-22, NUDOCS 9505180520
Download: ML20083L612 (5)


Text

{{#Wiki_filter:,.... 1 f %.E ENERGY 6200 Oak Tree Boulevord Moil Address: Donald C. Shelton independence OH PO Box 94661 Senior Vice President 216-447 3153 Cleveland. OH 44101-4661 Nuclear Fox 216 447-3123 May 12, 1995 PY-CEI/OEPA-0222L Ohio Environmental Protection Agency P.O. 13ox 163669 Columbus, Ohio 43216-3669 Gentlemen: Enclosed are the NPDES monthly report forms for the month of April, 1995. If you have questions or require additional information, please contact Donna Ti A ino at (216) 280-5514. Very truly yours, / VWw n Donald C. Shelton DGT:sc Enclosure cc NRC Project Manager NRC Resident Inspector Office NRC Document Control Desk (Docket No. 50-440) NRC Region III 9505180520 950430 PDR ADOCK 05000440 <fJ 3 \\ \\ Opefoting Componics: s k Clevesond tiectnc utuminctirsg Toledo Ed: son

1, 4 = 4500 J }, l} CLEVELAND, ELECTRIC ILLUM CO 3IB00016001 APR 1995 11 OHIO NUCLEAR GROUP 63461 C/O PERRY NUCLEAR POWER PLANT 10 CENTER ROAD ROOM E210 001 DISCHARGE FROM REGENERATE NORTH PERRY '44081 LAKE NElJrRALIZATION PITS FonM CEI PERRY J.J. GRIMM 1 1 1 2 3 999 999 999 96 1 CONDUI PH PH RESIDUE O&G FLOW (MAX) (MIN) T NFLT TOTAL MGD S.U. S.U. MG/L MG/L 50050 00401 00402 00_530_ 00550_ 01 AH AH All 02 AH AH AH 03 AH AH All 04 AH AH AH os All AH AH 06 All AH AH 07 0.0184 7.8 7.8 56 AA os All AH AH 09 All AH AH 10 0.0180 8.0 8.0 25 AA 11 t 0.0155 8.9 8.9 _l i 12 All AH AH 13 AH AH AH 14 AH AH AH 15 0.0157 7.4 7.3 to All AH AH 17 All AH AH 18 All AH AH 19 AH AH AH m 0.0166 7.7 7.6 39 AA 21 AH AH AH 1 ..22 AH All AH 23 All AH AH 24 0.0170 8.5 8.4 26 AA 25 AH All AH 26 AH AH AH 27 All AH AH 28 AH All AH 29 All AH All 30 AH AH AH " 31 0.1012 48.3 48.0 146 AA 0.0169 8.1 0.0 37 AA 0.0104 8.9 6.9 56 AA 0.0155 7.4 7.3 25 AA AA - BELOW DETECTABLE LIMIT (5 mg/l for O&G and 2.5 mg/l for RESIDUE) ) Ali - SAMPLE NOT TAKEN. NO DISCHARGE PERFORMED THIS DATE 1 3IB00016001 ~~"" ws ame llll1lll11lll:

m.,... '4500 f }'j -4, ; y!} m Vnsponyponu CLEVELAND ELECTRIC ILLUM CO 3IB00016800 APR 1995 11 OHIO- ~ ' NUCLEAR GROUP 63461 C/O PERRY NUCLEAR POWER PLANT 10 CENTER ROAD ROOM E210 800 INTAKE WATER AT INLET TO PLANT NORTH PERRY 44081 LAKE FROM LAKE ERIE Fonu i CEI, PERRY J.J. GRIMM 1 999 WATER TEMP F. 00011 ~ _.. _.. _., _.. _ _. 02 40 03 40 04 40 05-39 os 39 07 39 os 39 09 40 10 39 11 38 4 +- 12 37 13 40 14 41 15 42 16 42 17 43 18 43 19 43 20 44 21 44 22 45 23 45 24 45 25 45 26 45 27 46 28 47 29 48 30 47 31 1264 42 48 37 NONE 3IB00016800 Ama

  1. 111lllllllll J

P 7(

a...

4500 amn.fmirent ronu CLEVELAND ELECTRIC ILLUM CO 3IB00016004 APR 1995 11 OHIO NUCLEAR GROUP 63461 C/O PERRY NUCLEAR POWER PLANT 10 CENTER ROAD. ROOM E210 004 POINT REP OF DISCHARGE PRIOR TO NORTH PERRY 44081 LAKE ENTRY TO TUNNEL pagy CEI, PERRY J.J. GRIMM i 1 3 3 999 999 1 1 WATER CONDUI CHLOR PH TEMP FLOW FREE A F. MGD MG/L S.U. 00011 50050 50064 00400 01 46 70.0 0.00 02 44 72.4 0.00 03 50 67.5 0.00 04 48 74.9 0.00 8.3 05 45 73.7 0.00 06 45 60.9 0.00 07 48 72.1 0.00 8.3 08 48 72.7 0.00 m 48 71.6 0.00 to 45 66.9 0.00 11 47 62.7 0.00 8.2 12 51 67.7 0.00 13 54 68.8 0.00 14 52 70.2 0.00 8.3 15 52 70.2 0.00 to 53 74.9 0.00 17 50 72.4 0.00 is 50 94.4 0.00 8.2 19 50 84.4 0.00 20 47 80.8 0.00 21 49 76.9 0.00 8.2 22 53 74.8 0.00 23 49 72.5 0.00 24 47 62.3 0.00 25 47 49.7 0.00 8.1 26 47 80.0 0.00 27 40 85.5 0.00 2a 51 95.4 0.00 8.2 a 53 85.9 0.00 30 53 80.2 0.00 31 1470 2221.2 0.00 65.8 49 74.0 0.00 8.2 54 95.4 0.00 8.3 44 49.7 0.00 8.1 NORMAL DISCHARGE FLOW REDUCED BECAUSE OF ONGOING SERVICE WATER SYSTEM OUTAGE AND PIPING INSPECTION. 3 EE0'00iS 60'4~~ ~ "N*Ma es-Aam llHillHillli

1 r ,. ',.,0. 4500 anaf neront ronu 4 CLEVELAND ELECTRIC ILLUM CO. 3IB00016002 APR 1995 11 OHIO NUCLEAR GROUP 63461 C/O PERRY NUCLEAR POWER PLANT. 10 CENTER ROAD ROOM E210 002 DISCHARGE FROM CHEMICAL CLEANING i NORTH PERRY. 44081 LAKE LAGOON E PLANT pony 1 CEI, PERRY J.J. GRIMM 1 1 2 3 2 .2 2 999 999 96 1 96 96 96 CONDUI PH RESIDUE O&G ' PHOS-T COPPER IRON FLOW T NFLT TOTAL 'P-WET CU. TOT :FE. TOT MGD S.U. MG/L MG/L MG/L MG/L MG/L .... 50050 100400 00530 00550 _ 10066.5_._.01.042 _ '01045_._...., 01 02 03 04 05 03 07 08 09 10 11 .t.. l., __[ l I i 12 13 14 15 16 17 4 18 19 20 21 ...--{_-__._._;___ _i 22 . v 23 24 25 26 27 28 29 30 31 NO DISCHARGE OCCURRED DURING THE MONTH 3IB000165U'2 ~ ~~ rhAasA llllll11ll1lll ..}}