Department cf Nucl:Cr Engineering f,oont.g.s tng> nee,no
,m f:uam t ow'wmo bd W InD"004"9 Texas AW U'wersty conen s:a:,c.n. n m43 aiaa
ne *
- hvne 4D9:V45 4161 e f an 4331145 (443
$w
//
f 4NIh I'h L'C 5 f
r 29 Aug1991 U.S. Nuclear Regulatory Commission Document Control Desk Washington, D. C. 20555
REFERENCE:
License R-23, Docket #50 59
Dear Sir:
Please find enclosed one copy of the most recently completed annual operating report dated 1 June 1990 to 31 May 1991 for the AGN 201M reactor, Docket #50-59. If you have any questions concerning this report please contact me at (409) 845-4988.
Sincerely, g
Robert O. Berry Reactor Supervisor AGN 201M r
['
9109110270 910531 j
DR ADDCK 05o00o59 l
ANNUAL OPERATING REPORT of the TEXAS A&M UNIVERSITY AGN 201M TRAINING REACTOR NRC LICENSE R 23 JUNE 1,1990 MAY 31,1991 DEPARTMENT OF NUCLEAR ENGINEERING TEXAS A&M UNIVERSITY College Station,' Texas 77743 3133
4 ANNUAL OPERATING REPORT of the TEXAS A&M UNIVERSITY AGN 201M TRAINING REACTOR NRC LICENSE R 23 JUNE 1,1990 MAY 31,1991 Y
- h. &
Reviewed by ReactoQdpervisor b(J n
)
/
1..
l#dM ~
vibwec/by Department Head f
DEPARTMENT OF NUCLEAR ENGINEERING TEXAS A&M UNIVERSITY l
College Station, Texas 77743-3133 l
l ANNUAL OPERATING REPORT f
of the TEXAS A&M UNIVERSITY AGN 201M TRAINING REACTOR NRC LICENSE R 23 e
i JUNE 1,1990 MAY 31,1991 i
r k
i DEPARTMENT OF NUCLEAR ENGINEERING TEXAS A&M UNIVERSITY College Station, Texas 77743 3133 n
- 1. SUMM ARY This report details the portinent activities related to the Texas A&M University AGN 201M training facility operated by the Department of Nuclear Engineering during the period of 1 June 1990 until 31 May 1991. The contents of this report are intended to comply with requirements of 10CFR50 section 50.59(b), and Appendix A of the Technical t
Specifications for thls facility under license R 23.
The main function of this facility is to provide an operating nuclear system to be used as a research tool, to support the requirements of Nuclear Engineering courses and for operator training. The following Nuclear Engineering courses were supported during this reporting period:
NUEN 402: Nuclear Detection and Isotope Technology Laboratory NUEN 405: Nuclear Engineering Experiments NUEN 679: Practical Applications of Radiological Safety 1 All of the components that were replaced as part of preventive and corrective maintenance during this reporting period are detailed in Section 4 of this report, All of the components that have been replaced during this reporting period do not involve any unreviewed safety questions and are not expected to adversely affect the safe operation of th!s facility. The latest results of all major parameter surveillance tests performed during this reporting period are shown in Table 1.
I i
{
TABLE 1: REACTOR PARAMETERS SURVElLLANCE MEASUREinLWTS I
i i
i l
t DATE HQQ RE A C T I V I T Y W O R T H i
9 April 91 SAFETY ROD #1 1.100% Ak/k 9 April 91 SAFETY ROD #2 1.125% Ak/k i
t 9 April 91
- COARSE CONTROL ROD 1.177% Ak/k 9 April 91 FINE CONTROL ROD 0.381% Ak/k t
DATE HQQ ROD DROP TIMES i
12 Mar 91 SAFETY ROD #1 92 msec 12 Mar 91 SAFETY ROD #2 134 msec 12 Mar 91 COARSE CONTROL ROD 112 msec DATE BQQ REACTIVITY INSERTION RATES t
9 April 91 SAFETY ROD #1 0.0442% Ak/k/sec l
9 Apnl 91 SAFETY ROD #2 0.0497% Ak/k/sec
- 9. April 91 COARSE CONTROL ROD 0.0413% Ak/k/sec 9 - April 91 FINE CONTROL ROD 0.0132% Ak/k/sec l
TOTAL EXCESS REACTIVITY t
- 9 April 91 TOTAL EXCESS REACTIVITY
- 0.1885% Ak/k
- corrected to 20*C
- j i
L k
~,
- -. ~ - -
9
- 2. OPERATIONAL
SUMMARY
i LITill2ATION BY CATEGORY HOLIRS (a) Support of Nuclear Engineering Coursos 12.04 (b) Operator Training /Requalification 7.99 t
(c) Preventive / Corrective Maintenance 4.65 Total Ooerating Hours:
29.33 i
Total Hours Criticah 16.42 Total Watt Hours of Ooeration:
14.93 Average Power Level of Ooeration (Watts):
00.82 Number of Reactor Startuos 29
- 3. UNSCHEDULED SHUTDOWNS DATE TYPE CAUSE fiORRECTIVE ACTION 2/14/91 Channel #3 Spike on meter when Operator counseled High Level switching scales Channel #3 switch rotated to clean contacts 4
- 4. MAJOR SAFETY RELATED CORRECTIVE MAINTENANCE (a) 3/11/91 Replacea the following tubes in Channel #2 with identical replacements: V-6, V-11.
(b) 3/12/91 Replaced rod up interlock switch on Safety Rod #1 and K 10 relay with identical replacement components.
i 5.
(a) FACILITY CHANGES A new door has been added in the facility in the room 135 area. This rioor has been added in order to enhance security in this area, with the conversion of a counting laboratory to an undergraduate computer laboratory this new door was required.
(b) CHANGES TO PLANS AND PROCEDURES The facility diagrams contained in both the security and the emergency plan have been updated to include the addition of the new door in the room 13S area.
(c) NEW EXPERIMENTS OR TESTS No new experiments or tests were performed during this reporting period.
6.
SUMMARY
OF SAFETY EVALUATIONS No changes, tests or experiments were performed during this reporting period which meet the criteria of 10CFR50 paragraph 50.59 requiring a safety evaluation.
7.
SUMMARY
OF RADIOACTIVE EFFLUENTS RELEASED No liquid or solid radioactive waste was released during this reporting period.
8.
ENVIRONMENTAL RADIOLOGICAL SURVEYS No environmental radiological surveys were performed outside this facility during this reporting period.
9.
R ADIATION EXPOSURE l
During calender year 1990 two people's exposure were reported between 0.100 - 0.250 Rem. All of the other exposures were reported to be less than 0.100 Rem.
I 10.
MISCELLANEOUS
{
The following personnel participated satisfactorily in the AGN 201M t
requalification program.
{
l Robert O. Berry SOP 43374 Gerald Schlapper SOP 4210 t
i I
i i
l l-l l
i
. - +
--w w.r e w y-w si-m-rr-+r--ww
- -*r-^w----*Mm*T-n-+TT-
==e--YW*+nW
""'d-T-=5 Pr$
ar -