Responds to IE Bulletin 83-06 Re Nonconforming Matls Supplied by Tube-Line Corp.Acceptability of Matls/ Subassemblies Supplied by Dravo Corp Currently Being Evaluated.Supplemental Response Will Be Submitted by 831230
ML20082L763
Person / Time
Site: Seabrook  NextEra Energy icon.png
Issue date: 11/21/1983
From: Devincentis J
PUBLIC SERVICE CO. OF NEW HAMPSHIRE, YANKEE ATOMIC ELECTRIC CO.
To: Murley T
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
References
REF-SSINS-6820 IEB-83-06, SBN-581, NUDOCS 8312050574
Download: ML20082L763 (4)


Text

'; v *-

0 0

suom sum IPUBLIC SERVICE rasia ins om.

Companyof New HampeNr-a 1671 Worcester Road Framir cham, Mossachusetts 01701 (617). 872 8100 November 21, 1983 SBN-581 T.F.

B4.2.5 United States Nuclear Regulatory Commission Region I 631 Park Avenue King of Prussia, PA 19406 Attention:

Mr. Thomas C. Murley, Regional Administrator References :

(a) Construction Permits CPPR-135 and CPPR-136, Docket Nos. 50-443 and 50-444 (b) USNRC Letter, dated July 22, 1983, "IE Bulletin No. 83-06:

Nonconforming Materials Supplied by Tube-Line Corporation Facilitiea at Long Island City, New York; Houston, Texas; and Carol Stream, Illinois", R. C. DeYoung to CP and OL Holders (c) PSNH Letter, dated October 28, 1983, " Interim 10CFR50.55(e)

Report; Tube-Line Corporation Piping Elbows",

J. DeVincentis to R. W. Starostecki

Subject:

Response to IE Bulletin 83-06; Nonconforming Materials Supplied by Tube-Line Corporation

Dear Sir:

In response to the subject IE Bulletin and an active 10CFR50.55(e) item

[ Reference (c)], a survey of all potential vendors of materials supplied by Tube-Line Corporation was undertaken.

In summary, our review has identified only the shop fabricated piping Purchase order (9763.006-248-1) with Dravo Corporation, where Tube-Line material was used in an ASME III application.

The materials and subassemblies involved have been identified and placed on hold.

The acceptability of these materials / subassemblies is currently being evaluated.

Listed below are companies which are identified on Attachments 2 and 3 of IE Bulletin No. 83-06 as either purchasing or receiving companies and who have also provided safety related material / services on the Seabrook Project:

o Dravo Corporation (P.O. 248-1) - Tube-Line materials were supplied on this Purchase Order.

These materials have been identified and their acceptability is currently being evaluated.

b lb 1

8312050574 831121

/

PDR ADOCK 05000443

/. 0 i

l G

PDR I

- _ = - _ -. _.

o 9

United Sectco Nucicar Regulatory Cemaiocion Novecher 21, 1983 Attention:

Mr. Thomas C. Murley Page 2 i

The material supplied to Dravo was carbon steel SA-234 Grade WPB, j

seamless 900 elbows which are included in ASME III, Class 2 i

spools, intended for use in the Component Cooling Water System.

i Also, reducers, tees, and elbows (both 450 and 90 ) are included 0

in ASME III, class 3 spools intended for Component Cooling Water and Diesel Generator Systems. A total of twenty-eight spools are on hold at job-site. Additional material and subassemblies are on hold at Dravo's shop.

Dravo QA personnel have visited Tube-Line's Long Island City, New York facility and have verified that the material provided to Dravo for use at Seabrook was in compliance with the requirements of ASME III NCA-3800 No supplemental nondestructive examination was required by ASME III NC-2000 or ND-2000 for the material involved, i.e., seamless SA-234 Grade WPB fittings; however, arrangements have been made to have one fitting f rom each heat supplied by Tube-Line tested to verify that the properties are comparable to the results recorded on the Certified Material Test Reports.

This effort was initiated in response to the subject IE Bulletin which indicated that, in some i

instances, independent testing of the fitting material revealed lower mechanical properties than those indicated on the Material Test Reports. The initial testing has begun, but the results are not yet available.

It is anticipated that the testing will be completed by November 30, 1983.

o Metal Bellows Co. (P.O. 248-75) - Response from Metal Bellows indicates that Tube-Line materials were not used in this Purchase Order.

Pullman Power Products (P.O. 248-51) - Pullman only provides o

installation services, all materials are provided by others.

Koch Process Systems (P.O. 275-2) - Response from Koch Process o

indicates that Tube-Line materials were not used on this Purchase i

O rde r.

o Grinnell Fire Protection System Co. (P. O. 70-1) - Tube-Line i

materials were supplied on this Purchase Order.

However, these materials were used in an ANSI B31.1 application, not for ASME III work.

Therefore, the concerns cited in IE Bulletin No. 83-06 are not considered applicable to this work.

Guyon Alloys (P.O. 248-54) - Response from Guyon Alloys indicates o

that Tube-Line materials were not used in this Purchase Order.

Pittsburgh-Des Moines (including W. J. Woolley) (P.O. 15-1) -

o Response from PDM indicates that Tube-Line materials were not used in this Purchase Order.

i-3, ymvr--.-,p.,,-.---.%..-w---.--,----.mwm4

.,.,,w--,_

y

-- -. -,, - -w e-

-,w---w.

,,w,.,-

O O

~

Unitcd Statoc Nuclear Regulatory C;mmiccica N:vsrber 21, 1983 Attention:

Mr. Thomas C. Murley Page 3 In addition to the vendors listed above, vendors for sixty-one other Purchase Orders, where Tube-Line materials could possibly have been used, were contacted and they responded by indicating that Tube-Line materials were not provided.

Six of the sixty-eight total vendors contacted indicated that Tube-Line materials had been supplied, however, it has been determined that these materials are intended for use in non-ASNE III applications.

As indicated above, only the Dravo Corporation Purchase Order supplied materials are intended for use in ASME III applications.

A supplemental response to IE Bulletin No. 83-06 will be submitted to your office by December 30, 1983, subsequent to the completion of the additiooal testing that is currently in process.

Very truly yours.

YANKEE A'IDMIC ELECTRIC COMPANY hh John DeVincentis Project Manager ALL/bal cc: Atomic Safety and Licensing Board Service List United States Nuclear Regulatory Commission Document Control Desk Washington, DC 20555

o 6

~.

William S. Jordan, III, Esquire Brentwood Board of Selectmen Harmon & Weiss RLD Dalton Road 1725 I Street, N.W. Suite 506 Brentwood, New Hampshire 03833 Washington, DC 20006 Roy P. Lessy, Jr., Esquire Office of the Executive Legal Director Edward F. Meany U.S. Nuclear Regulatory Commission Designated Representative of Washington, DC 20555 the Town of Rye 155 Washington Road Robert A. Backus, Esquire Rye, NH 03870 116 Lowell Street P.O. Box 516 Calvin A. Canney Mancehster, NH 03105 City Manager City Hall Philip Ahrens, Esquire 126 Daniel Street Assistant Attorney General Portsmouth, NH 03801 Department of the Attorney General Augusta, ME 04333 Dana Bisbee, Esquire Assistant Attorney General Mr. John B. Tanzer Office of the Attorney General Designated Representative of 208 State House Annex the Town of Hampton Concord, NH 03842 5 Morningside Drive Hampton, NH 03842 Anne Verge, Chairperson Board of Selectmen Roberta C. Pevear Town Hall Designated Representative of South Hampton, NH 03S42 the Town of Hampton Falls Drinkwater Road Patrick J. McKeon Hampton Falls, NH 03844 Selectmen's Office 10 Central Road Mrs. Sandra Cavutis Rye, NH 03870 Designated Representative of the Town of Kensington Carole F. Kagan, Esq.

RFD 1 Atomic Safety and Licensing Board Panel East Kingston, NH 03827 U.S. Nuclear Regulatory Commission Jo Ann Shotwell, Esquire Assistant Attorney General Mr. Angie Machiros Environmental Protection Bureau Chairman of the Board of Selectmen Department of the Attorney General Town of Newbury One Ashburton Place,-19th Floor Newbury, MA 01950 Boston, MA 02108 Town Manager's Office Senator Gordon J. Humphrey Town Hall - Friend Street U.S. Senate Amesbury, Ma.

01913 Washington, DC 20510 (Attn: Tom Burack)

Senator Gordon J. Humphrey 1 Pillsbury Street Diana P. Randall Concord, NH 03301.

70 Collins Street (Attn: Herb Boynton)

SEabrook, NH 03874 Richard E. Sullivan, Mayor Donald E. Chick City Hall Town Manager Newburyport, MA 01950 Town of Exeter.

10 Front Street Exeter, NH 03833